18_E1024BT RFExp

FCC ID: 2AF8ZE1024BT

RF Exposure Info

Download: PDF
FCCID_3956950

                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                  1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                  Shenzhen, China
                 ‘all
                                  Telephone:     +86—755—26648640

   1E E)6 :0                      Fax:
                                  Website:
                                                 +86—755—26648637
                                                 www.cga—cert.com
                                                                                   Report Template Version: VO3
                                                                                   Report Template Revision Date: Mar.1st, 2017



                 RF Exposure Evaluation Report

Report No. :                    CQASZ20180500101E—03

Applicant:                      1MORE INC.

Address of Applicant:           Tianliao Building F14 East Block (New Materials Industrial Park), Xueyuan Road,
                                Nanshan District, Shenzhen, China
Manufacturer:                   1MORE Shen Zhen Acoustic Technology Co., Ltd.

Address of                      Tianliao Building 1403—1411, Zone A Tianliao Industrial Park, Tacyuan Street,
Manufacturer:                   Nanshan District, Shenzhen, P.R. China

Equipment Under Test (EUT):
Product:                 1MORE Stylish Dual—dynamic Driver BT In—Ear Headphones
Model No.:               E1024BT
Brand Name:              1MORE
FCC ID:                         2AF8ZE1024BT
Standards:                      47 CFR Part 1.1307
                                47 CFR Part 2.1093
                                KDB447498D01 General RF Exposure Guidance v06

Date of Test:                   2018—05—25 to 2018—07—04
Date of Issue:                  2018—07—04
 Test Result :                  PASS*®


Tested By:
                                         Joxt00 @   aron Ma)


Reviewed By:
                                               C ( Jack Ai)


Approved By:
                                                 ( Jack Ai)




* In the contfiguration tested, the EUT complied with the standards specified above.

The test reportis effective only with both signature and specialized stamp, The result(s) shown in this report refer only to

the sample(s) tested. Without written approval of CQA, this report can‘t be reproduced except in full.


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQASZ20180500101E-03


2   Version
                            Revision History Of Report

          Report No.          Version         Description           Issue Date
     CQASZ20180500101E-03     Rev.01         Initial report        2018-07-04




                              Page:2 of 6


                                                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                    Report No.: CQASZ20180500101E-03



3         Contents
                                                                                                                                                                         Page
1       COVER PAGE .............................................................................................................................................................1

2       VERSION .....................................................................................................................................................................2

3       CONTENTS .................................................................................................................................................................3

4       GENERAL INFORMATION .......................................................................................................................................4
    4.1     CLIENT INFORMATION................................................................................................................................................4
    4.2     GENERAL DESCRIPTION OF EUT ................................................................................................................................4
5       SAR EVALUATION ....................................................................................................................................................5
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................5
       5.1.1 Standard Requirement .................................................................................................................................5
       5.1.2 Limits ..............................................................................................................................................................5
       5.1.3 EUT RF Exposure .........................................................................................................................................5




                                                                     Page:3 of 6


                                              Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20180500101E-03



4    General Information
4.1 Client Information
     Applicant:                 1MORE INC.
     Address of Applicant:      Tianliao Building F14 East Block (New Materials Industrial Park), Xueyuan
                                Road, Nanshan District, Shenzhen, China
     Manufacturer:              1MORE Shen Zhen Acoustic Technology Co., Ltd.
     Address of Manufacturer:   Tianliao Building 1403-1411, Zone A Tianliao Industrial Park, Taoyuan
                                Street, Nanshan District, Shenzhen, P.R. China

4.2 General Description of EUT
    Product Name:               1MORE Stylish Dual-dynamic Driver BT In-Ear Headphones
    Model No.:                  E1024BT
    Trade Mark:                 1MORE
    Hardware Version:           FW_E1024_BM20L_V0.7
    Software Version:           PCB-EM022-V0.3(2018-05-10)
    Operation Frequency:        2402MHz~2480MHz
    Bluetooth Version:          V4.1
    Modulation Technique:       Frequency Hopping Spread Spectrum(FHSS)
    Modulation Type:            BT classic: GFSK, π/4DQPSK, 8DPSK
                                BLE: GFSK
    Number of Channel:          BT classic:79
                                BLE:40
    Hopping Channel Type:       Adaptive Frequency Hopping systems
    Sample Type:                portable production
    Test Software of EUT:       Non Signaling Test Tool (manufacturer declare )
    Antenna Type:               Wired antenna
    Antenna Gain:               -0.73dBi
    Power Supply:               lithium battery:DC3.7V, Charge by DC5.0V




                                       Page:4 of 6


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                     Report No.: CQASZ20180500101E-03



5    SAR Evaluation
5.1 RF Exposure Compliance Requirement
5.1.1 Standard Requirement
     According to KDB447498D01 General RF Exposure Guidance v06
     4.3.1. Standalone SAR test exclusion considerations
           Unless specifically required by the published RF exposure KDB procedures, standalone 1-g
     head or body and 10-g extremity SAR evaluation for general population exposure conditions, by
     measurement or numerical simulation, is not required when the corresponding SAR Exclusion
     Threshold condition, listed below, is satisfied.
5.1.2 Limits
     The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:

     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

                                                                                     17



     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion
5.1.3 EUT RF Exposure


For BT: Measurement Data
                                             GFSK mode
               Test channel                                  Peak Output Power (dBm)
                 Lowest                                                2.420
                 Middle                                                2.180
                 Highest                                               0.460
                                           π/4DQPSK mode
               Test channel                                  Peak Output Power (dBm)
                 Lowest                                                2.290
                 Middle                                                2.080
                 Highest                                               0.410
                                             8DPSK mode
               Test channel                                  Peak Output Power (dBm)
                 Lowest                                                2.320
                 Middle                                                2.140
               Highest                                               0.490
Remark: The Conducted Peak Output Power data refer to report Report No.: CQASZ20180500101E-01


                                         Page:5 of 6


CQ‘A                                             Shenzhen Huaxia Testing Technology Co., Ltd

LE E ;E ;“                                                            Report No.: CQASZ20180500101E—03




 For BLE:

 Measurement Data
                                               GFSK mode
               Test channel                                  Peak Output Power (dBm)
                  Lowest                                                 —5.6

                  Middle                                                —5.81
                  Highest                                               —5.41

Remark: The Conducted Peak Output Power data refer to report Report No.: CQASZ20180500101E—02


BDR, EDR and BLE can not simultaneous transmitting at same time.
      The worst case data: GFSK_lowest channel
      The Max Conducted Peak Output Power is 2.42dBm in lowest channel(2.402GHz);
      The best case gain of the antenna is —0.73dBi.
      EIRP= 2.42dBm — 0.73dBm= 1.69dBm
      1.69Bm logarithmic terms convert to numeric result is nearly 1.48mW
      According to the formula. calculate the EIRP test result:
     [{max. power of channel, including tune—up tolerance, mW)/{min. test separation distance, mm)] —
      [Nf(GHz)]
      General RF Exposure = (1.48mW /5 mm ) x v2.402GHz =0.46          ®
      SAR requirement:
      S= 3.0                                                          @;
      0 <@.
      So the SAR report is not required.




                                           Page:6 of 6



Document Created: 2019-10-08 08:05:17