PayRange | BluKey Pro | User Manual



PayRange BluKey Pro™
Product Information

Models:

                                    BluKey Pro™ 18cdr | 18‐pin | Card

                                    BluKey Pro™ 12cd | 12‐pin | Card

                                    BluKey Pro™ 12d                                                                                                                                                   | 12‐pin
                                          The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.




Contents
Introduction .................................................................................................................................................. 2
Interfaces ...................................................................................................................................................... 2
Installation .................................................................................................................................................... 2
Introduction ................................................................................................... Error! Bookmark not defined.
Before Installation......................................................................................................................................... 4
BluKey Pro Machine Harness Selection Guide .............................................................................................. 5
Installation Steps ........................................................................................................................................... 6
Machine Controller Programming ................................................................................................................ 7
BluKey Pro Device Configuration .................................................................................................................. 8
Card Reader Harnesses Reference .............................................................................................................. 11
Troubleshooting / Light Codes .................................................................................................................... 11
Regulatory Approval & Warnings ............................................................................................................... 14
Contacting PayRange Support .................................................................................................................... 14
Appendix A: Price Setup .............................................................................................................................. 16
Appendix B: BluKey Pro Firmware Upgrade ............................................................................................... 17
Appendix C: Splicing Wires.......................................................................................................................... 17
Appendix D: Specifications.......................................................................................................................... 19
Document History ....................................................................................................................................... 22


                                                                                                                                                                                                                  P a g e 1 | 23


PayRange | BluKey Pro | User Manual




Introduction
The turnkey PayRange payment system includes a BluKey hardware device for the machine along with a
mobile app and transaction processing service for the customer. Consumers maintain a prepaid balance
on their smartphones and use it to make payments at a variety of machines that can include vending,
amusement, parking, transit ticketing, and laundry equipment.

BluKey Pro (BKPro) device provides mobile payment functionality and works with virtually any
commercial Laundry machine and other kinds of machines that accept payments.

Card‐enabled models support machines with installed card reader (serial and pulse).

RTC (real‐time clock)‐enabled models support timekeeping in case of power outage.

Installing BluKey Pro takes just 2‐3 minutes and requires only plugging in an appropriate cable harness
into the machine.

Interfaces
                                                                   1. CARD connector
                                                                      (present only on
                                                                      card‐enabled models)
                                                                   2. Power LED
                                                                   3. Button
                                                                   4. MACHINE Connector




Installation
BluKey Pro requires electrical connections to internal machine signals with appropriate cable harness.

BluKey Pro should be placed inside machine enclosure, with the following considerations:

       Optimal placement for RF performance (place device close to openings in metal enclosure,
        ensure that its internal antenna is not obstructed by metal and conductive parts, shields and
        cables).
       Cable harness should reach machine connectors.
       Do not place on vibrating parts (motors, compressors, etc.).
       Do not place where can be exposed to water or condensate, or high heat or extremely cold
        temperatures.




                                                                                       P a g e 2 | 23


PayRange | BluKey Pro | User Manual


PayRange Mobile Payment System
PayRange Mobile Payment System consists of:

       BluKey Pro™ (accepts payments from PayRange mobile app)
       Cable Harness (connects BluKey Pro to Laundry Machines)
       Optional Card Harness (connects BluKey Pro to Card reader installed in the Laundry Machine)


   Laundry Machine           Machine Coin         Cable Harness               BluKey Pro™
                             Acceptor and
                             Card Readers




                                                                                    P a g e 3 | 23


PayRange | BluKey Pro | User Manual


Before Installation
  1. Create your PayRange Operator Account
     a. Go to http://manage.payrange.com.
     b. Sign up for a customer account. If you already have a customer account, Sign in.
     c. Once logged in, click Create an Operator Account (may need to click Account first).
     d. Select Operator Sign up (at the bottom of the page), follow prompts to create your
        account.
     e. Setup ACH for payment with your bank routing and account number.
     Note: Though it is possible to skip banking information, Weekly payments will commence only
     after banking is setup, and there are mobile sales.
     f. Issue free vend code for installation tests.

  2. Setup for Your Machine Installers
     Prepare Installers:
     a. Download and install the PayRange app.
     b. Load funds to the app with a credit/debit card, or issue free vend code.
     c. Prepare additional point of sale material such as table tents, location flyers, and
        location posters. These can be downloaded free at
        https://www.payrange.com/resources.
     Note: Because the PayRange device is inside the machine, the users won’t know it is there
     unless you tell them. The more you do to promote PayRange, the quicker they will become loyal
     users of your machines.
     d. Provide necessary tools and supplies
          i. BluKey Pro device
          ii. Harness for the machine
              See section “BluKey Pro Machine Harness Selection Guide” below to choose appropriate
              harness.
          iii.    Harness for card reader (if machines are equipped with card readers)
          iv.     Room key and necessary building access cards
          v.      Operator (Installer / Service) key for the machine
          vi.     Wire cutters
          vii.    Pliers (for splice crimping)
          viii.   Smartphone, tablet or connected laptop with PayRange app
          ix.     Installer login & password into Operator Account




                                                                                         P a g e 4 | 23


PayRange | BluKey Pro | User Manual



BluKey Pro Machine Harness Selection Guide
     There are many brands and models of laundry machines. This document contains only brief
     information on how to select harness appropriate for a given laundry machine.
     PayRange sales team has more advanced tools and can decode machine information from full
     model and serial numbers and advise required harnesses and installation instructions.
     The following sections provide steps to identify machine type, cover supported machine
     interfaces and available harnesses.
     After selecting harness for the machine, review notes for that harness in section “Error!
     Reference source not found.” Error! Reference source not found.. There might be some
     additional considerations and necessary steps.
     To determine which harness to use, locate machine control board and identify available
     connector type, then choose harness corresponding to the connector type.

  1. Speed Queen and Alliance Laundry Systems Machines
     a. ACA type (including MGD)
     If machine has black plastic case holding the control board and the control board has 7‐pin
     cashless connector:
            7‐pin connector is not used (no card reader): Use C2/D2 harness
            7‐pin connector is used (machine has card reader)
                 o   Pulse mode: Use C7/D7 harness if coin slot is not installed, and C8/D8 harness if
                     coin slot is installed.
                 o   Serial mode: Use C2/D2 harness for machine‐side connection and connect card
                     reader to “CARD” with appropriate card reader harness.
     b. MDC type
     If machine has grey metal case holding the control board and the control board has 7‐pin
     cashless connector:
            7‐pin connector is not used (no card reader): Use C1/D1 harness
            7‐pin connector is used (machine has card reader)
                 o   Pulse mode: Use C7/D7 harness if coin slot is not installed, and C8/D8 harness if
                     coin slot is installed (note that coin is disabled on MDC controls for serial card
                     readers). Harness power connector will have to be cut off and wires spliced to
                     machine 24VAC power.
                 o   Serial mode: Use C1/D1 harness for machine‐side connection and connect card
                     reader to “CARD” with appropriate card reader harness.
     c. NetMaster type
     If machine has grey metal case holding the control board and the control board has 4‐pin
     cashless connector:


                                                                                     P a g e 5 | 23


PayRange | BluKey Pro | User Manual

            4‐pin connector is not used (no card reader) ‐ Use C4/D4 harness
            4‐pin connector is used (machine has card reader)
                 o   Pulse mode: Use C7/D7 harness if coin slot is not installed, and C8/D8 harness if
                     coin slot is installed. Harness power connector will have to be cut off and wires
                     spliced to machine 24VAC power.
                 o   Serial mode: NetMaster not supported in pulse mode.

  2. Maytag and Some Whirlpool Machines
     a. Px type (with 6‐pin connector)
     If machine has control board with 6‐pin cashless connector:
            6‐pin connector is not used (no card reader) ‐ Use C3/D3 harness
            6‐pin connector is used (machine has card reader) – Use C3/D3 harness and connect
             card reader to “CARD” with appropriate card reader harness.
     b. ADC type (without 6‐pin connector)
     If machine has control board without 6‐pin cashless connector:
            If machine has no card reader – Use C6/D6 harness
            If machine has card reader installed: contact PayRange for support.

  3. LG Machines
     a. C type
     If machine has front panel harness with cashless connectors:
            cashless connectors are not used (no card reader) ‐ Use C5/D5 harness
            cashless connectors are used (machine has card reader) – Use C5/D5 harness and
             connect card reader to “CARD” with appropriate card reader harness.

  4. Other Machine Types
     Contact PayRange for support.

Installation Steps
     These are generic installation instructions. Each individual machine and harness may have
     additional steps or details relevant to installation.

  1. Disconnect power from the machine

  2. Open machine cabinet
     Unlock panel with operator/service key, position the panel as necessary for service.

  3. Connect harness to BluKey Pro



                                                                                     P a g e 6 | 23


PayRange | BluKey Pro | User Manual


   4. Connect Coin Acceptor connectors:

       a. Disconnect machine’s Coin Acceptor harness connector (if present)
       b. Plug in pass‐through Coin Acceptor connectors into Coin Acceptor connector and
          machine’s harness connector
       If Coin Acceptor is not present on the machine but machine has Coin Acceptor harness, plug in
       only one connector.
       Coin Acceptor is not required for BKPro operation.

   5. Power up the machine (leave the control panel open)

   6. BluKey Pro should power up and turn on solid blue LED
       See section “Troubleshooting / Light Codes” on page 11 if BluKey Pro does not power up or does
       not turn on solid blue LED.

   7. Configure BluKey Pro
       See section “BluKey Pro Device Configuration ” on page 8.

   8. Configure machine
       See section “Machine Controller Programming” on page 7.

   9. Power off the machine

   10. Place wires and BluKey Pro inside the machine
       Fix BluKey Pro with adhesive fastener tape.

   11. Close machine control panel

   12. Power up the machine

   13. Verify machine operation
       Check mobile payment, coin payment, start cycle and verify that PayRange app shows “Machine
       in Use”

Machine Controller Programming
BKPro can connect to various payment accepting inputs: coin, debit, serial. Depending on machine,
harness and chosen operation mode (pulse or serial) of BKPro, machine should be programmed to work
in the chosen mode and have the input activated. Follow the below sections to program Laundry
machine.




                                                                                    P a g e 7 | 23


PayRange | BluKey Pro | User Manual


    1. Using Coin Inputs
For harnesses connecting to coin inputs and using pulse mode (e.g. C7/L7 and C8/L8) – if machine has
Coin Acceptor connector, but Coin Acceptor is not installed, enable Coin Acceptor input to receive
mobile payments. Follow these steps:

        a.   Locate programming guide for the machine
        b.   Open machine service door with operator key
        c.   Consult the guide and follow the steps to enable Coin Acceptor
        d.   Set coin payment value to match BKPro pulse settings
        e.   Close the service door

    2. Using Debit Inputs
For harnesses connecting to debit inputs and using pulse mode (e.g. C1/L1, C2/L2, C3/L3 and C4/L4) – if
machine has Debit connector, enable Debit input to receive mobile payments. Follow these steps:

        a.   Locate programming guide for the machine
        b.   Open machine service door with operator key
        c.   Consult the guide and follow the steps to enable Debit connector
        d.   Set Pulse mode (turn off serial mode)
        Note: some machines require jumper plug to enable serial mode. Remove the plug to turn off
        serial mode.
        e. Set debit payment value to match BKPro pulse settings
        f. Close the service door

    3. Using Serial Mode
For harnesses connecting to debit inputs and using serial mode (e.g. C1/L1, C2/L2, C3/L3 and C4/L4) – if
machine has Debit connector, enable Debit input and serial mode to receive mobile payments. Follow
these steps:

        a.   Locate programming guide for the machine
        b.   Open machine service door with operator key
        c.   Consult the guide and follow the steps to enable Debit connector
        d.   Set Serial mode (turn on serial mode)
        Note: some machines require jumper plug to enable serial mode.
        e. Close the service door

BluKey Pro Device Configuration
    1. Register BluKey Pro device (using website)
        Note: This can be prepared off‐site, before installation.
        a. Login with your operator account to the Manage website at
           https://manage.payrange.com


                                                                                       P a g e 8 | 23


PayRange | BluKey Pro | User Manual


     b. Click DEVICES > Register in the left panel
     c. Enter device Serial number and Pin (from BluKey Pro back label)
     d. Enter Display name (it will be shown in the app to customers)
     e. Enter other relevant information (location name, address, etc.)
     f. Take a picture of the machine and upload to the “Picture” field
     g. If there is a PayRange decal for the machine, attach the decal to the machine. If there
        is scan to pay QR code, enter Scan to Pay number from the decal
     h. Configure the device to Auth Type: Pulse, Cash Value per Pulse: 0.25
     i. Set Pulse on: / Pulse off: to match Bill Acceptor timings required for the machine
        controller (see machine documentation)
     j. Add Credits/Pulse/Amount in “Configure Multi Credit” section (match machine prices)
     k. Configure harness: Select harness from the list, enter money values for cash counter
        pulses, review options for each signal (click “edit” icon on the right).
     l. Click the Register button to complete device registration

  2. Register BluKey Pro device (using mobile app)
     Note: When done filling information on the screen, click Next button to advance. Use Back
     button if need to return and correct any information.
     a. Open PayRange app, Sign In with your operator account (if not logged in)
     b. Click on the hamburger menu (top left), select Operator Mode > Register Device
     c. Enter device Serial number and Pin (from BluKey Pro back label), or click camera icon
        and scan the barcode
     d. Enter Display name (usually it is a number from machine sticker for customer)
     e. Enter other relevant information (location name, address, etc.)
     f. Take a picture of the machine
     g. If there is scan to pay PayRange decal for the machine, Enter Scan to Pay number
        from the sticker, attach the sticker to the machine
     h. Click the Register button to complete device registration
     i. Proceed to section “Configure BluKey Pro device for payment (using website)” below

  3. Configure BluKey Pro device for payment (using website)
     Note: This can be prepared off‐site, before installation.
     a. Login with your operator account to the Manage website at
        https://manage.payrange.com
     b. Enter device Serial number (from BluKey Pro back label) into search box at the top,
        click Search > Search Device
     c. Click on the Device ID in search results to open Device view
     d. Click Edit Device
     e. Configure the device to Auth Type: Pulse, Cash Value per Pulse: 0.25



                                                                                  P a g e 9 | 23


PayRange | BluKey Pro | User Manual


    f. Set Pulse on: / Pulse off: to match Bill Acceptor timings required for the machine
       controller (see machine documentation)
    g. Add Credits/Pulse/Amount in “Configure Multi Credit” section (match machine prices)
    h. Configure harness: Select harness from the list, enter money values for cash counter
       pulses, review options for each signal (click “edit” icon on the right).
    i. Click Update




                                                                         P a g e 10 | 23


PayRange | BluKey Pro | User Manual



Card Reader Harnesses Reference
    Card Reader Harnesses Summary
Name      Part Number     Description

  R1      11.01213‐xx     DIY

  R2      11.01214‐xx     Heartland 8‐pin

  R3      11.01215‐xx     Greenwald 8‐pin

  R4      11.01216‐xx     KioSoft 10‐pin



    R1 | 11.01213‐00 | DIY Card Reader Harness
        R1 harness supports any card reader, but it requires customer to splice wires into existing card
        reader connector.

    R2 | 11.01214‐00 | Heartland Card Reader Harness
        R2 harness supports Heartland card readers with 8‐pin Molex Micro‐Fit connector.
        Attention! Greenwald and Heartland connectors are the same but have different pinouts (2 pins
        swapped). Using incorrect harness may damage BKPro device and Card Reader.

    R3 | 11.01215‐00 | Greenwald Card Reader Harness
        R3 harness supports Greenwald card readers with 8‐pin Molex Micro‐Fit connector.
        Attention! Greenwald and Heartland connectors are the same but have different pinouts (2 pins
        swapped). Using incorrect harness may damage BKPro device and Card Reader.

    R4 | 11.01216‐00 | Heartland Card Reader Harness
        R4 harness supports KioSoft card readers with 10‐pin Molex Micro‐Fit connector.

Troubleshooting / Light Codes
Symptom                 LED Pattern     Cause                     Fix

BKPro LED is solid                      BluKey Pro ready          (Normal operation)
blue

BKPro LED does not                      Machine not powered       Power on the machine
light up
                         (No power)     Power is not provided     Use alternative power source per
                                        on machine’s harness      section “Error! Reference source not
                                                                  found.”

                                        Harness connection        Check / reconnect harness
                                                                  connectors


                                                                                       P a g e 11 | 23


PayRange | BluKey Pro | User Manual

BKPro LED is solid red                  BluKey Pro is in wrong    Contact PayRange for support
                                        mode

BKPro LED slowly                        Machine is not            Refer to machine manual to enable
flashes red                             accepting payments        payments / return to enabled state.
                         (Disabled by
                           machine)

BKPro LED slowly             TBD        Machine is in use         Wait for machine to complete its
flashes TBD                                                       cycle.
                         (Machine in
                            use)                                  TBD: both in use and no payment?

BKPro LED flashes                       No payments for last 24   Power‐cycle BluKey Pro to reset the
series of red/blue                      hours                     warning. Check if machine has any
                                                                  problems running.

BKPro LED slowly                        Communicating with        (Normal operation)
flashes blue                            App

BKPro LED slowly                        Transaction in progress   (Normal operation)
flashes purple

BKPro LED quickly                       Upgrading                 Keep power on until done
flashes blue

BKPro LED quickly                       BluKey Pro hardware       Replace BluKey Pro
flashes red                             error

BKPro LED quickly                       Uploading transactions,   (Normal operation)
flashes purple                          Downloading upgrades

Mobile payment                          1. Check if BluKey Pro is in Ready state / BluKey Pro LED is
does not work                              solid blue.
                                        2. Check if BluKey Pro flashes “Transaction in progress” LED
                                           pattern during mobile payment. If not, check Internet /
                                           data connection on mobile device.
                                        3. If using pulse mode, check if “pulse on” time in device
                                           settings in Manage is set correctly (see section “Configure
                                           BluKey Pro device for payment (using website)”).

Coin count does not                     1. Check connection to coin acceptor sensor/switch.
work                                    2. Check for correct polarity of connection to coin acceptor
                                           sensor/switch.
                                        3. Check if coin count input is configured properly for the
                                           harness in Manage (see section “Machine Controller
                                           Programming”).

App does not show                       1. Check harness connection to BKPro and to machine
“Machine in Use”                        2. Check if Inhibit/Available signals are configured properly


                                                                                       P a g e 12 | 23


PayRange | BluKey Pro | User Manual

during cycle            for the harness in Manage (see section “Machine
                        Controller Programming”).

Machine does not     1. Check if machine accepts coins if BluKey Pro harness is
accept coins            disconnected from the machine’s coin harness (can
                        disconnect harness from BluKey Pro). If not, replace coin
                        acceptor and its harness.
                     2. Check machine’s wiring (a loose wire in connector pin
                        could be causing coin sensor/switch disconnects).
                     3. For optical coin sensors: Clean coin sensor optics or
                        replace coin sensor or coin acceptor assembly.




                                                                 P a g e 13 | 23


PayRange | BluKey Pro | User Manual



Regulatory Approval & Warnings
    Modification statement
 PayRange has not approved any changes or modifications to this device by the user. Any changes or
 modifications could void the user’s authority to operate the equipment.


    United States
 This device complies with Part 15 of the FCC Rules.
 Operation is subject to the following two conditions:
 (1) This device may not cause harmful interference; and
 (2) This device must accept any interference received, including interference that may cause undesired
 operation


    Canada
 This device complies with Industry Canada license‐exempt RSS standard(s). Operation is subject to
 the following two conditions:

 (1) This device may not cause interference; and

 (2) This device must accept any interference received, including interference that may cause
 undesired operation of the device.

 Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
 exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit
 pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
 radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.




    Device Labelling
        FCC ID:                2AF78‐01046

        IC:                    21341‐01046


Contacting PayRange Support
For assistance with installing and operating your BluKey Pro devices, please contact our support group:




                                                                                       P a g e 14 | 23


PayRange | BluKey Pro | User Manual



 1. For Technical Support:                     2. For Sales and Marketing Support:

    Phone: +1 (855) 856‐6398 (menu option 1)      Phone: +1 (855) 856‐6398 (menu option 2)
    Email: support@payrange.com                   Email: sales@payrange.com




                                                                         P a g e 15 | 23


PayRange | BluKey Pro | User Manual


Appendix A: Price Setup
When you register or edit the device, you can
also set up the price. Here are some guidelines:

•   Price per credit is the total price to play the
    machine

•   Cash value per pulse is how much money
    each pulse is worth

•   Pulses per credit is how many pulses it takes
    to get to the total price

   Pulse on (ms) and Pulse off (ms) is the length
    of the pulse for the particular machine. This
    defaults to 100, if left blank




                                                      P a g e 16 | 23


PayRange | BluKey Pro | User Manual


Appendix B: BluKey Pro Firmware Upgrade
     PayRange may release firmware updates with new functionality and improvements.
     BKPro firmware is upgraded automatically, in the background. Contact PayRange support for
     additional information on firmware upgrades.



Appendix C: Splicing Wires
     On some machines power has to be taken from machine’s wiring harness or credit wires have to
     be spliced to coin switch wiring harness. Use the following procedure to splice wires.


  1. Splicing harness wires directly to machine wires (do this procedure for both
     wires)
                                                The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.




     Insert one of the machine wires
         leading into the control board into
         the pass through of the splice
     Note: Photo shows splice with metal
     brace pulled out for clarity.
     Do not remove metal brace, but make
     sure it is pulled out enough so the wire
     can be fully inserted.




                                                The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.




     Close the 1st part of the tab
     Note: Photo shows splice with metal
     brace pulled out for clarity.




                                                                                                                                                                                                             P a g e 17 | 23


PayRange | BluKey Pro | User Manual

                                                The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.




    Insert one of the wires from BluKey
        Pro harness into the stopped
        opening of the splice until it hits
        the end of the opening.
    You may need to clip the wire from
    harness connector that is not going to be
    used.
    You should be able to see the wire in the
    window by the metal brace.
                                                The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.




    Crimp the metal brace into the wires
        (with pliers), until brace is flush
        with the splice case.




                                                The link ed image cannot be display ed. The file may hav e been mov ed, renamed, or deleted. Verify that the link points to the correct file and location.




    Close the cover. Check that wire
        cannot be pulled out with slight
        tug.




                                                                                                                                                                                                             P a g e 18 | 23


PayRange | BluKey Pro | User Manual


Appendix D: Specifications
       2. BluKey Pro Models
          Model           Part Number      MACHINE     CARD                      Notes
                                           Connector   Conn.
BluKey Pro 18cdr          10.01261          18 pins      ●
BluKey Pro 12cd           10.01265          12 pins      ●
BluKey Pro 12d            10.01267          12 pins


Model CARD Coin1 Coin2 Relay External Internal Mnemonic                                Notes
Suffix Conn.                           Battery Battery
   c       ●                                                   card            accepts Dx harness
   d               ●      ●                                 dual coin
   r                               ●                          relay                 18‐pin only
In addition to these models, the timekeeper battery is optional, and can be installed internally or
externally.

       3. Absolute Maximum Ratings
Symbol            Description                                      Min        Max         Unit   Notes

TSTG              Storage temperature                              ‐40         85          °C    1

VCC               AC1/GND Power supply, DC                         ‐0.3        55         VDC    peak

VCC               AC1/AC2 Power supply, AC (rms)                    0          39         VAC    peak

VDDO              5V_OUT power supply output, DC                  +4.75       +5.25        V

IDDO              5V_OUT power supply output, DC                     ‐         100        mA

VDDI              5V_IN power supply input, DC                     ‐0.5        +6.5        V

VDI               Digital input voltage                            ‐0.3     VDD + 0.3      V     2

IDO               Digital output current                                       ±50        mA

VHVDO             HVOUT pins relay contacts voltage, AC (rms)        ‐         240        VAC    3

VHVDO             HVOUT pins relay contacts voltage, DC (peak)       ‐         400        VDC    3

IHVDO             HVOUT pins relay contacts current                  ‐        0.120        A     3

       1. Determined according to JEDEC Standard JESD22‐A103, High Temperature Storage Life.
       2. VDD is 5V_OUT on MACHINE connector, and 5V_IN on CARD connector.
       3. Maximum switching power (VPK * IPK) 48VA.




                                                                                        P a g e 19 | 23


PayRange | BluKey Pro | User Manual


       4. Operating Conditions
Symbol            Description                                   Min         Typ        Max         Unit

TO                Operating temperature range                    ‐30          ‐         85         °C

VCC               AC1/GND Power supply, DC                        9          12         50         VDC

VCC               AC1/AC2 Power supply, AC (rms)                 16          24         29         VAC

ICC               Power supply current, max (@ 9VDC or            ‐           ‐        575         mA
                  16VAC)

UCC               Power consumption                               ‐           ‐        3.8         W (1)

VDDO              5V_OUT power supply output, DC                  ‐         +5.0        ‐          V

VDDI              5V_IN power supply input, DC                  +1.65        +5        +5.5        V

IDDI              5V_IN power supply input, DC                    ‐           ‐         62         mA

VIL               Input logic level low                                              VDD*0.4       V (2)

VIH               Input logic level high                    VDD*0.6+0.4       ‐         ‐          V (2)

VOH               Output high voltage (IO = ‐32mA)             VDD‐0.7        ‐         ‐          V (2)

VOL               Output low voltage (IO = +32mA)                 ‐           ‐        0.55        V

       1. Power consumption excludes load on AC1/AC2/DC_OUT by connected card reader.
       2. VDD is 5V_OUT on MACHINE connector, and 5V_IN on CARD connector.

       5. ESD handling ratings
Symbol            Description                                     Min.       Max.      Unit    Notes

VHBM              Electrostatic discharge voltage,                ‐2000     +2000        V     1
                  human body model

VCDM              Electrostatic discharge voltage,                ‐500       +500        V     2
                  charged‐device model

ILAT              Latch‐up current at ambient temperature of      ‐100       +100       mA     3
                  105°C

       1. Determined according to JEDEC Standard JESD22‐A114, Electrostatic Discharge (ESD) Sensitivity
          Testing Human Body Model (HBM).
       2. Determined according to JEDEC Standard JESD22‐C101, Field‐Induced Charged‐Device Model
          Test Method for Electrostatic‐Discharge‐Withstand Thresholds of Microelectronic Components.
       3. Determined according to JEDEC Standard JESD78, IC Latch‐Up Test.




                                                                                     P a g e 20 | 23


PayRange | BluKey Pro | User Manual


       6. RF Specifications
 Symbol              Description                                    Min.   Max.      Unit     Notes

 FRF                 RF Frequency range (Bluetooth 4.1)             2402   2483.5    MHz

 PRFO                RF Output power                                         +9      dBm

 SRFI                RF Sensitivity (at 0.1% BER)                   ‐93              dBm

 GRF                 Antenna Gain                                           3.0      dBi


       7. Connector Pinouts
MACHINE Connector Pinout
BKPro MACHINE connector is either 12‐pin JST S12B‐PUDSS or 18‐pin JST S18B‐PUDSS.

 Pin Name                  Type                      Pin     Name           Type

   1 AC1                   Power input                     2 AC2            Power input

   3 IN                    Input, RxD or Inhibit           4 GND            Common

   5 COIN2A                Input, isolated                 6 COIN2K         Input, isolated

   7 AvailableIn           Input                           8 5V_OUT         Aux power output

   9 OUT_NO                Output, open collector         10 COIN1HiZ       Input

 11 COIN1A                 Input, isolated                12 COIN1K         Input, isolated

 13 ReservedOut*           Output                         14 COIN2HiZ*      Input

 15 HVOUT_NO*              Relay contact                  16 ReservedIn*    Input

 17 HVOUT_COM*             Relay contact                  18 HVOUT_NC*      Relay contact

Notes:

          (*) Pins 13‐18 are not present on 12‐pin BKPro models.
          Direction of input and output is given from BKPro’s perspective.
          GND is common for all non‐isolated inputs and outputs.
          COIN1HiZ and COIN2HiZ are referenced to GND. COIN1A/K and COIN2A/K remain isolated from
           GND for positive signals under 50V.
          BKPro provides up to 100mA of current on auxiliary power output 5V_OUT.

CARD Connector Pinout
BKPro CARD connector is JST S10B‐PUDSS (10‐pin). It is present only on card‐enabled models.

 Pin Name                  Type                      Pin     Name           Type

   1 TXD                   Serial TX Data output          2 DC_OUT          Rectified power supply




                                                                                    P a g e 21 | 23


PayRange | BluKey Pro | User Manual

      3 IN1               Auxiliary input                             4 AC2                    Power supply output

      5 AC1               Power supply output                         6 RXD                    Serial RX Data input

      7 GND               Common for all signals                      8 5V_IN                  5V DC Input

      9 OUT1              Auxiliary output                          10 OUT2                    Auxiliary output

Notes:

         Direction of input and output is given from BKPro’s perspective.
         GND is common for 5V_IN, DC_OUT and all inputs and outputs.
         Power supply output is passed from MACHINE connector AC1/AC2 pins, can be AC or DC.
         DC_OUT derived by rectifying and filtering input voltage provided to MACHINE connector
          AC1/AC2 or AC1/GND input voltage. DC_OUT voltage depends on actual input voltage and total
          load (40V for 24VAC input).
         BKPro requires 5V supply voltage (up to 64mA load) provided by card reader to drive output
          signals and reference input signals.

Attention: Do not connect CARD connector AC1/AC2 to devices that have only half‐wave rectifier (one of
AC1/AC2 is connected to GND, and another is connected to single diode). Doing so will damage BKPro
and card reader device. Connect GND/DC_OUT to the card reader power input!

Battery Connector Pinout
BKPro Battery connector is JST SM02B‐SURS‐TF (2‐pin). It is present only on RTC‐enable models, to
connect backup battery for the internal real‐time‐clock.

 Pin Name                 Type                                    Pin      Name                Type

      1 3V_IN             (+) 3V from battery                         2 GND                    (‐) Common

Notes:

         Recommended CR1632. Only lithium‐based 3V watch coin cell batteries are supported (e.g.
          CR2016, CR2032).

Recommended Mating Parts
MACHINE Connector: JST PUDP‐12V‐S for 12‐pin models, JST PUDP‐18V‐S for 18‐pin models.

CARD Connector: JST PUDP‐10V‐S.

Battery Connector: JST 02SUR‐32S.

Document History
Issue     Date            Reason
0.1       16 Nov 2018     Initial Draft

0.2       3 Apr 2019      Regulatory approvals, electrical characteristics, models.

1.0       22 Apr 2019     Combine Reference Guide and Data Sheet into User Manual, add French regulatory statement.




                                                                                                       P a g e 22 | 23


PayRange | BluKey Pro | User Manual




                                      P a g e 23 | 23



Document Created: 2019-05-20 08:29:54
Document Modified: 2019-05-20 08:29:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC