Test report

FCC ID: 2AF6B-RAK831

Test Report

Download: PDF
FCCID_3859104

                                          FCC PART 15.247
                                             TEST REPORT
                                                             For

             Shenzhen Rakwireless Technology Co., Ltd.
RM1007, Hangsheng Technology Building, 4th South Gaoxing Avenue, Science and Technology
                       Park, Nanshan District, Shenzhen, China


                                       FCC ID: 2AF6B-RAK831


              Report Type:                                     Product Type:
              Original Report                                  LoRa WAN GATEWAY



                   Report Number:           RSZ180322002-00


                        Report Date:        2018-05-07

                                            Rocky Kang

                       Reviewed By:         RF Engineer

                       Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                            6/F., West Wing, Third Phase of Wanli Industrial
                                            Building, Shihua Road, Futian Free Trade Zone,
                                            Shenzhen, Guangdong, China
                                            Tel: +86-755-33320018
                                            Fax: +86-755-33320008
                                            www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any
agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked
with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ180322002-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  DUTY CYCLE ................................................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  EXTERNAL I/O CABLE..................................................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8

TEST EQUIPMENT LIST ...........................................................................................................................................9
FCC §15.247 (I) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................................11
FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS .....................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................13
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS.............................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST RESULTS SUMMARY ..........................................................................................................................................17
  TEST DATA ................................................................................................................................................................18
FCC §15.247(a) (2) – 6 dB EMISSION BANDWIDTH ............................................................................................22
  APPLICABLE STANDARD ............................................................................................................................................22
  TEST PROCEDURE ......................................................................................................................................................22
  TEST DATA ................................................................................................................................................................22



FCC Part 15.247                                                                                                                                       Page 2 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ180322002-00



FCC §15.247(b) (3) - MAXIMUM CONDUCTED OUTPUT POWER ..................................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  TEST PROCEDURE ......................................................................................................................................................25
  TEST DATA ................................................................................................................................................................25
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................26
  APPLICABLE STANDARD ............................................................................................................................................26
  TEST PROCEDURE ......................................................................................................................................................26
  TEST DATA ................................................................................................................................................................26
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................28
  APPLICABLE STANDARD ............................................................................................................................................28
  TEST PROCEDURE ......................................................................................................................................................28
  TEST DATA ................................................................................................................................................................28




FCC Part 15.247                                                                                                                                       Page 3 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ180322002-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

The Shenzhen Rakwireless Technology Co., Ltd.’s product, model number: RAK831
(FCC ID: 2AF6B-RAK831) or the "EUT" in this report was a LoRa WAN GATEWAY which was measured
approximately: 80 mm (L) * 50 mm (W) * 5.0 mm (H), rated with input voltage: DC 5.0V.

* All measurement and test data in this report was gathered from production sample serial number: 180322002
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-03-22.


Objective
This report is prepared on behalf of Shenzhen Rakwireless Technology Co., Ltd. in accordance with Part 2-
Subpart J, Part 15-Subparts A and C of the Federal Communication Commission’s rules.

The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203, 15.205, 15.207, 15.209 and 15.247 rules.


Related Submittal(s)/Grant(s)
No Related Submittal.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.

Measurement Uncertainty


                      Parameter                                   uncertainty
            Occupied Channel Bandwidth                               ±5%
         RF Output Power with Power meter                           ±0.5dB
           RF conducted test with spectrum                          ±1.5dB
        AC Power Lines Conducted Emissions                         ±1.95dB
                All emissions, radiated                            ±4.88dB
                     Temperature                                     ±3℃
                      Humidity                                       ±6%
                   Supply voltages                                  ±0.4%




FCC Part 15.247                                                                                  Page 4 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ180322002-00

Test Facility
The test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on
the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 342867, the FCC Designation No. : CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15.247                                                                            Page 5 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ180322002-00

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in testing mode, which was provided by manufacturer.
For LoRa mode, Detailed Frequency as below:

                                     Frequency                              Frequency
                  Channel                                Channel
                                       (MHz)                                  (MHz)
                     1                  923.3               5                  925.7
                     2                  923.9               6                  926.3
                     3                  924.5               7                  926.9
                     4                  925.1               8                  927.5

EUT was tested with Channel 1, 4 and 8.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
“VMware.exe” was uesd mode and power level is 9. SF=12

Duty cycle
                                               LoRa Mode




FCC Part 15.247                                                                          Page 6 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                        Report No.: RSZ180322002-00



     Band           Duty Cycle (%)          T(us)                   1/T(kHz)         VBW Setting                  10log(1/x)
     LoRa                7.68               35000                     0.03                1kHz                      11.15


Local Support Equipment List and Details

      Manufacturer                     Description                               Model             Serial Number

            DELL                           Adapter                             PA-1900-02D                       N/A

       Rakwireless                    Debug board                               FT2232HL                         N/A

            DELL                           Laptop                                E6410                           N/A



External I/O Cable

                  Cable Description                    Length (m)                 From Port                       To

     Un-Shielding Detachable DC Power Cable                   1.2                   Laptop                      Adapter
     Un-Shielding Detachable AC Power Cable                   1.5                   LISN                        Adapter
       Un-Shielding Detachable USB Cable                      1.0                Debug board                    Laptop
        Un-Shielding Detachable FFC Cable                     0.2                   EUT              Debug board


Block Diagram of Test Setup
For conducted emission
                                                                                                                  LISN

                                  Laptop    10cm           10cm
                                                                       Debug                 EUT
                                                                                  10cm
                                                    Adapter            Board
                                                                                                    1.0 Meter




         Non-Conductive Table
         80 cm above Ground Plane


                                              1.5 Meters
FCC Part 15.247                                                                                                 Page 7 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180322002-00

SUMMARY OF TEST RESULTS


                  FCC Rules                           Description of Test               Result

         §15.247 (i) & §1.1310 &
                                         Maximum Permissible exposure (MPE)           Compliance
                §2.1091
                   §15.203                          Antenna Requirement               Compliance

                  §15.207 (a)                AC Line Conducted Emissions              Compliance
            §15.205, §15.209,
                                                     Spurious Emissions               Compliance
               §15.247(d)
              §15.247 (a)(2)                   6 dB Emission Bandwidth                Compliance

              §15.247(b)(3)                Maximum Conducted Output Power             Compliance

                  §15.247(d)           100 kHz Bandwidth of Frequency Band Edge       Compliance

                  §15.247(e)                        Power Spectral Density            Compliance




FCC Part 15.247                                                                            Page 8 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                    Report No.: RSZ180322002-00

TEST EQUIPMENT LIST

                                                                         Serial        Calibration    Calibration
      Manufacturer              Description             Model
                                                                        Number            Date         Due Date
                                             Conducted Emissions Test
    Rohde & Schwarz          EMI Test Receiver         ESCS30           100176         2017-08-04     2018-08-04
                                                                     3560.6650.12-
    Rohde & Schwarz                LISN                ENV216                          2017-12-21     2018-12-21
                                                                      101613-Yb
    Rohde & Schwarz          Transient Limiter         ESH3Z2          DE25985         2017-11-19     2018-05-17
    Rohde & Schwarz          CE Test software          EMC 32            V8.53.0          NCR            NCR
                            Conducted Emission                       UF A210B-1-
           N/A                                           N/A                           2017-11-12     2018-05-12
                                  Cable                              0720-504504
                                               Radiated Emission Test
      Sunol Sciences           Horn Antenna            DRH-118          A052604        2017-12-22     2020-12-21
    Rohde & Schwarz           Signal Analyzer          FSIQ26        8386001028        2017-04-24     2018-04-24
           Mini                Pre-amplifier         ZVA-183-S+      5969001149        2017-05-21     2018-05-21
           HP                    Amplifier             HP8447E       1937A01046        2017-11-19     2018-05-21
      Sunol Sciences        Broadband Antenna            JB1            A040904-2      2017-12-17     2020-12-16
    Rohde & Schwarz          EMI Test Receiver          ESCI            101120         2018-01-11     2019-01-11
       Ducommun                                      UFA210A-1-       MFR64369
                                 RF Cable                                              2017-11-19     2018-05-21
      technologies                                   4724-30050U      223410-001
       Ducommun
                                 RF Cable              104PEA           218124002      2017-11-19     2018-05-21
      technologies
       Ducommun
                                 RF Cable              RG-214               1          2017-11-19     2018-05-21
      technologies
       Ducommun
                                 RF Cable              RG-214               2          2017-11-22     2018-05-22
      technologies
    Rohde & Schwarz          Auto test software        EMC 32             V9.10           NCR            NCR
                                                 RF Conducted Test
         Agilent           P-Series Power Meter        N1912A        MY5000448         2018-01-02     2019-01-02
                              Wideband Power
         Agilent                                       N1921A        MY54210016        2018-01-02     2019-01-02
                                  Sensor
      WEINSCHEL               10dB Attenuator            N/A              N/A          2017-11-22     2018-05-23
                                SPECTRUM
    Rohde & Schwarz                                     FSU26            200120        2017-12-24     2018-12-24
                                ANALYZER
        Ducommun
                                 RF Cable              RG-214               3          2017-11-22     2018-05-22
       technologies

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15.247                                                                                      Page 9 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                         Report No.: RSZ180322002-00

FCC §15.247 (I) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247(i) and subpart §1.1310, systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                           (B) Limits for General Population/Uncontrolled Exposure

Frequency Range          Electric Field           Magnetic Field              Power Density          Averaging Time
     (MHz)              Strength (V/m)            Strength (A/m)                (mW/cm2)               (minutes)

     0.3–1.34                   614                     1.63                       *(100)                   30
     1.34–30                 824/f                      2.19/f                  *(180/f²)                   30
     30–300                  27.5                       0.073                       0.2                     30
    300–1500                     /                        /                        f/1500                   30
  1500–100,000                   /                        /                         1.0                     30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculated Formulary:

Predication of MPE limit at a given distance
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);

Calculated Data:

The worst case as below:

                                                   Max Tune-up
                           Antenna Gain             Conducted         Evaluation       Power         MPE
           Frequency
                                                      Power            Distance       Density        Limit
             (MHz)
                                                                         (cm)        (mW/cm2)      (mW/cm2)
                         (dBi)        (numeric)   (dBm) (mW)
          923.3-927.5     2.0           1.58       11         12.59      20               0.004       0.6


Result: The device meet FCC MPE at 20 cm distance




FCC Part 15.247                                                                                         Page 10 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ180322002-00

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
Unit must be professionally installed, and installer shall be responsible for verifying that the correct
antenna is employed with the unit.
And according to FCC 47 CFR section 15.247 (b), if the transmitting antennas of directional gain greater
than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna
exceeds 6 dBi.


Antenna Connector Construction
The EUT has an external antenna with a non-standard antenna jack which the maximum antenna gain is
2.0 dBi, fulfill the requirement of this section. Please refer to the EUT photos.


Result: Compliance.




FCC Part 15.247                                                                              Page 11 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ180322002-00

FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz



Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.
FCC Part 15.247                                                                             Page 12 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ180322002-00


Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:

      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

      Margin = Limit – Corrected Amplitude


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207,


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

               Temperature:                24 ℃
          Relative Humidity:               56 %
              ATM Pressure:             101.0 kPa

      The testing was performed by Jacob Kong on 2018-04-18.

     EUT operation mode: Transmitting




FCC Part 15.247                                                                                   Page 13 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ180322002-00


     AC 120V/60 Hz, Line



                         90


                         80


                         70

                                                                                                    QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.991090               38.5           20.0             56.0          17.5           QP
           1.042250               38.7           20.0             56.0          17.3           QP
           1.136690               38.6           20.0             56.0          17.4           QP
           1.286710               41.3           20.0             56.0          14.7           QP
           1.574510               35.8           20.0             56.0          20.2           QP
           2.051550               37.1           20.0             56.0          18.9           QP
           0.991090               30.9           20.0             46.0          15.1          Ave.
           1.042250               30.7           20.0             46.0          15.3          Ave.
           1.136690               32.6           20.0             46.0          13.4          Ave.
           1.286710               35.9           20.0             46.0          10.1          Ave.
           1.574510               29.5           20.0             46.0          16.5          Ave.
           2.051550               30.4           20.0             46.0          15.6          Ave.




FCC Part 15.247                                                                                    Page 14 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                    Report No.: RSZ180322002-00


     AC 120V/60 Hz, Neutral



                         90


                         80


                         70

                                                                                                      QP
                         60
          Level in dBμ




                                                                                                       AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M        20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin            Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)           (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.991030               38.9           20.0             56.0          17.1             QP
           1.113170               38.6           20.0             56.0          17.4             QP
           1.172330               40.4           20.0             56.0          15.6             QP
           1.282710               38.3           20.0             56.0          17.7             QP
           1.684470               36.0           20.0             56.0          20               QP
           2.027670               36.7           20.0             56.0          19.3             QP
           0.991030               30.2           20.0             46.0          15.8            Ave.
           1.113170               32.6           20.0             46.0          13.4            Ave.
           1.172330               33.6           20.0             46.0          12.4            Ave.
           1.282710               33.2           20.0             46.0          12.8            Ave.
           1.684470               27.9           20.0             46.0          18.1            Ave.
           2.027670               30.3           20.0             46.0          15.7            Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude
FCC Part 15.247                                                                                      Page 15 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180322002-00

FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205;


EUT Setup
Below 1 GHz:




Above 1GHz:




The radiated emission tests were performed in the 3 meters test site, using the setup accordance with the
ANSI C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits.




FCC Part 15.247                                                                              Page 16 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ180322002-00

EMI Test Receiver & Spectrum Analyzer Setup
The system was investigated from 30 MHz to 10 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

           Frequency Range             RBW             Video B/W          IF B/W         Measurements

         30 MHz – 1000 MHz            100 kHz           300 kHz           120 kHz              QP
                                       1MHz              3 MHz                /                PK
                                                               Note 1
             Above 1 GHz               1MHz            10 Hz                  /             Average
                                                               Note 2
                                       1MHz            >1/T                   /             Average
Note 1: when duty cycle is no less than 98%
Note 2: when duty cycle is less than 98%

Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Title 47, Part 15,
Subpart C, section 15.205, 15.209 and 15.247.


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.




FCC Part 15.247                                                                                   Page 17 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                Report No.: RSZ180322002-00

Test Data
     Environmental Conditions

                            Temperature:             24 ℃
         Relative Humidity:                          56 %
                           ATM Pressure:         101.0 kPa

      The testing was performed by Jacob Kong on 2018-04-17.

    Test range 30MHz – 10GHz, please refer to the following tables and plots.

    Worst case at Low channel:



                           80



                           70                                                                    Fundamental


                           60
                                                                      Electric Field Strength QP-3m

                           50
          Level in dBμV/




                           40



                           30



                           20



                           10



                            0
                            30M       50   60   80   100M             200         300      400     500       800   1G
                                                             Frequency in Hz




FCC Part 15.247                                                                                                Page 18 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                            Report No.: RSZ180322002-00

                    Corrected         Antenna                    Turntable     Correction
     Frequency                                     Antenna                                            Limit      Margin
                    Amplitude          height                     position      Factor
       (MHz)                                       Polarity                                         (dBμV/m)      (dB)
                    (dBμV/m)            (cm)                      (degree)      (dB/m)
     102.051125       40.15            242.0           H             0.0          -8.2               43.50         3.35
     114.009125        39.99            275.0          H           171.0             -7.0            43.50         3.51
     126.009500        39.42            313.0          H           175.0             -5.8            43.50         4.08
     150.033500        40.30            222.0          H            0.0              -4.5            43.50         3.20
     240.004000        42.71            116.0          H           135.0             -3.2            46.00         3.29
     398.977125        44.02            107.0          H           170.0             -0.3            46.00         1.98


                                                                                   FCC Part
                           Receiver            Rx Antenna Corrected Corrected
  Frequency                          Turntable                                   15.247/205/209
                                                           Factor Amplitude
    (MHz)         Reading             Degree Height Polar
                          PK/QP/Ave.                       (dB/m) (dBμV/m) Limit         Margin
                  (dBμV)                       (m) (H/V)                      (dBμV/m)     (dB)
                                      Low Channel (923.3 MHz)
     923.30        62.50         QP              123     2.4     H    33.80                 96.30        /            /
     923.30        63.40         QP              151     1.8     V    33.80                 97.20        /            /
     901.99        15.27         QP              350     1.3     H    34.50                 49.77      76.30        26.53
     901.99        15.40         QP              198     1.4     V    34.50                 49.90      77.20        27.30
    1846.60        48.59         PK              123     1.2     H    -5.22                 43.37       74          30.63
    1846.60        43.02         Ave.            123     1.2     H    -5.22                 37.80       54          16.20
    1846.60        46.35         PK              355     1.6     V    -5.22                 41.13       74          32.87
    1846.60        41.47         Ave.            355     1.6     V    -5.22                 36.25       54          17.75
                                                Middle Channel(925.1MHz)
     925.10        62.10         QP               27     1.7     H    33.80                 95.90        /            /
     925.10        63.30         QP              138     1.5     V    33.80                 97.10        /            /
    1850.20        49.03         PK              165     1.7     H    -5.17                 43.86       74          30.14
    1850.20        44.29         Ave.            165     1.7     H    -5.17                 39.12       54          14.88
    1850.20        47.21          PK              43       1.4      V        -5.17          42.04       74          31.96
    1850.20        42.64         Ave.             43       1.4      V        -5.17          37.47       54          16.53
                                                High Channel(927.5 MHz)
    927.50         62.40          QP             248       2.4      H        33.80          96.20        /             /
    927.50         62.90          QP             212       1        V        33.80          96.70        /             /
    928.01         15.27          QP             108       1.8      H        34.50          62.90      76.20        13.30
    928.01         15.40          QP              68       1.3      V        34.50          63.80      76.70        12.90
    1855.00        49.11          PK             135       1.4      H        -5.17          43.94       74          30.06
    1855.00        44.18         Ave.            135       1.4      H        -5.17          39.01       54          14.99
    1855.00        47.32          PK             243       2.3      V        -5.17          42.15       74          31.85
    1855.00        42.53         Ave.            243       2.3      V        -5.17          37.36       54          16.64

Note:
Corrected Factor = Antenna factor (RX) + Cable Loss – Amplifier Factor
Corrected Amplitude = Corrected Factor + Reading
Margin = Limit - Corrected. Amplitude
The other spurious emission which is 20dB to the limit was not recorded.

FCC Part 15.247                                                                                                Page 19 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                       Report No.: RSZ180322002-00

                                  Pre-scan with High channel for Peak
                                              Horizontal




                                                    Vertical




FCC Part 15.247                                                                       Page 20 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                Report No.: RSZ180322002-00

                                          Pre-scan for Average
                                               Horizontal




                                                    Vertical




FCC Part 15.247                                                                Page 21 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ180322002-00


FCC §15.247(a) (2) – 6 dB EMISSION BANDWIDTH
Applicable Standard
Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to
   measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
   reference level on the measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 6 dB from the reference
   level. Record the frequency difference as the emission bandwidth.
4. Repeat above procedures until all frequencies measured were complete.


                                                         Signal Analyzer
                   EUT                      Attenuator



Test Data
     Environmental Conditions

                Temperature:                 25 ℃
          Relative Humidity:                 52 %
              ATM Pressure:                101.0 kPa

      The testing was performed by Jacob Kong on 2018-04-13.

     Test Result: Pass.

     Please refer to the following table and plots.




FCC Part 15.247                                                                             Page 22 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                            Report No.: RSZ180322002-00


    EUT operation mode: Transmitting

                                                Frequency                    6 dB Emission Bandwidth                     Limit
              Channel
                                                  (MHz)                               (kHz)                              (kHz)

                  Low                             923.3                                  615.38                          ≥500
               Middle                             925.1                                  586.54                          ≥500
                  High                            927.5                                  586.54                          ≥500


                                                                  Low Channel
                                                                       * RBW 100 kHz      Marker 1 [T1 ]
                                                                       * VBW 300 kHz                  8.41 dBm
                      Ref    34 dBm              * Att    20 dB            SWT 2.5 ms        923.341666667 MHz

                            Offset    10.5 dB                                             ndB [T1]    6.00   dB
                      30
                                                                                          BW 615.384615385   kHz
                                                                                          Temp 1 [T1 ndB]           A
                                                                                                      2.20   dBm
                      20
               1 PK                                                                          922.995512821   MHz
               MAXH
                                                                                          Temp 2 [T1 ndB]
                                                                       1                                           LVL
                      10                                                                              2.17   dBm
                                                                                             923.610897436   MHz
                                                     T1                             T2

                      0



                      -10



                      -20
                                                                                                                   3DB


                      -30



                      -40



                      -50



                      -60


                      Center   923.3 MHz                          200 kHz/                         Span   2 MHz




              Date: 13.APR.2018       23:53:53




FCC Part 15.247                                                                                                              Page 23 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                            Report No.: RSZ180322002-00


                                                             Middle Channel
                                                                         * RBW 100 kHz    Marker 1 [T1 ]
                                                                         * VBW 300 kHz                9.09 dBm
                      Ref    34 dBm              * Att    20 dB              SWT 2.5 ms      925.119230769 MHz

                            Offset    10.5 dB                                             ndB [T1]    6.00   dB
                      30
                                                                                          BW 586.538461538   kHz
                                                                                          Temp 1 [T1 ndB]           A
                                                                                                      3.20   dBm
                      20
               1 PK                                                                          924.801923077   MHz
               MAXH
                                                                                          Temp 2 [T1 ndB]
                                                                         1                                         LVL
                      10                                                                              3.09   dBm
                                                     T1                              T2      925.388461538   MHz


                      0



                      -10



                      -20
                                                                                                                   3DB


                      -30



                      -40



                      -50



                      -60


                      Center   925.1 MHz                          200 kHz/                         Span   2 MHz




              Date: 13.APR.2018       23:39:59




                                                              High Channel
                                                                         * RBW 100 kHz    Marker 1 [T1 ]
                                                                         * VBW 300 kHz               10.16 dBm
                      Ref    35.5 dBm            * Att    20 dB              SWT 2.5 ms      927.487179487 MHz

                            Offset    10.5 dB                                             ndB [T1]    6.00   dB
                      30                                                                  BW 586.538461538   kHz
                                                                                          Temp 1 [T1 ndB]           A
                                                                                                      4.05   dBm
               1 PK   20                                                                     927.201923077   MHz
               MAXH
                                                                                          Temp 2 [T1 ndB]
                                                                     1                                             LVL
                                                                                                      4.20   dBm
                      10
                                                                                     T2      927.788461538   MHz
                                                     T1


                      0



                      -10



                      -20                                                                                          3DB



                      -30



                      -40



                      -50



                      -60


                      Center   927.5 MHz                          200 kHz/                         Span   2 MHz




              Date: 13.APR.2018       23:27:03




FCC Part 15.247                                                                                                            Page 24 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180322002-00


FCC §15.247(b) (3) - MAXIMUM CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure

1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to one
    test equipment.
3. Add a correction factor to the display.


                                                         Power Meter
                  EUT                  Attenuator



Test Data
     Environmental Conditions

              Temperature:               25 ℃
         Relative Humidity:              52 %
             ATM Pressure:             101.0 kPa

      The testing was performed by Jacob Kong on 2018-04-13.

    EUT operation mode: Transmitting


                               Frequency              Peak Output Power                 Limit
           Channel
                                 (MHz)                      (dBm)                       (dBm)
             Low                  923.3                       8.46                        30
            Middle                925.1                       9.15                        30
            High                  927.5                      10.27                        30




FCC Part 15.247                                                                             Page 25 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180322002-00


FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, the radio frequency power that is produced by the intentional radiator
shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level
of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
conducted power limits based on the use of RMS averaging over a time interval, as permitted under
paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


                                                          Signal Analyzer
                    EUT                     Attenuator


Test Data
     Environmental Conditions

                Temperature:                 25 ℃
          Relative Humidity:                  52 %
              ATM Pressure:                 101.0 kPa

      The testing was performed by Jacob Kong on 2018-04-13.

     EUT operation mode: Transmitting

     Test Result: Compliance

     Please refer to the following plots.




FCC Part 15.247                                                                              Page 26 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                            Report No.: RSZ180322002-00

                                                           Band Edge, Left Side
                                                                           * RBW 100 kHz   Marker 1 [T1 ]
                                                                           * VBW 300 kHz             -42.45 dBm
                      Ref    34 dBm                * Att   20 dB            SWT 20 ms         894.628205128 MHz

                            Offset    10.5 dB
                      30

                                                                                                                     A

                      20
               1 PK
               MAXH
                                                                                                                    LVL
                      10
                               D1 8.5 dBm


                      0



                      -10
                                     D2 -11.5 dBm


                      -20
                                                                                                                    3DB


                      -30



                      -40                              1



                      -50



                      -60


                      Center   902 MHz                              5 MHz/                         Span    50 MHz




              Date: 14.APR.2018       00:06:48




                                                           Band Edge, Right Side
                                                                           * RBW 100 kHz   Marker 1 [T1 ]
                                                                           * VBW 300 kHz             -17.54 dBm
                      Ref    35.5 dBm              * Att   20 dB            SWT 2.5 ms        928.024038462 MHz

                            Offset    10.5 dB
                      30
                                                                                                                     A

               1 PK   20
               MAXH
                                                                                                                    LVL
                      10       D1 10.2 dBm



                      0



                      -10            D2 -9.8 dBm
                                                                       1

                      -20                                                                                           3DB



                      -30



                      -40



                      -50



                      -60


                      Center   928 MHz                             300 kHz/                         Span    3 MHz




              Date: 13.APR.2018       23:28:28




FCC Part 15.247                                                                                                            Page 27 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ180322002-00

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the
antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous
transmission. This power spectral density shall be determined in accordance with the provisions of
paragraph (b) of this section. The same method of determining the conducted output power shall be used to
determine the power spectral density.

Test Procedure
1.  Use this procedure when the maximum peak conducted output power in the fundamental emission is
    used to demonstrate compliance.
2. Set the RBW to: 3kHz≤ RBW≤100 kHz.
3. Set the VBW ≥ 3×RBW.
4. Set the span to 1.5 times the DTS bandwidth.
5. Detector = peak.
6. Sweep time = auto couple.
7. Trace mode = max hold.
8. Allow trace to fully stabilize.
9. Use the peak marker function to determine the maximum amplitude level within the RBW.
10. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.


                                                          Signal Analyzer
                    EUT                  Attenuator


Test Data
     Environmental Conditions

               Temperature:               25 ℃
         Relative Humidity:               52 %
             ATM Pressure:              101.0 kPa

      The testing was performed by Jacob Kong on 2018-04-13.

     EUT operation mode: Transmitting

     Test Result: Pass

                                        Frequency                 PSD               Limit
               Channel
                                          (MHz)                (dBm/3kHz)        (dBm/3kHz)

                   Low                    923.3                   4.15                ≤8
                  Middle                  925.1                   5.16                ≤8
                  High                    927.5                   6.07                ≤8



FCC Part 15.247                                                                            Page 28 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                    Report No.: RSZ180322002-00

                                           Power Spectral Density, Low Channel
                                                                     * RBW 3 kHz    Marker 1 [T1 ]
                                                                     * VBW 10 kHz               4.15 dBm
                      Ref    34 dBm              * Att   20 dB        SWT 105 ms       923.294083333 MHz

                            Offset    10.5 dB
                      30

                                                                                                             A

                      20
               1 PK
               MAXH
                                                                                                            LVL
                      10
                                                                 1


                      0



                      -10



                      -20
                                                                                                            3DB


                      -30



                      -40



                      -50



                      -60


                      Center   923.3 MHz                     92.3 kHz/                     Span   923 kHz




              Date: 13.APR.2018       23:58:27




                                         Power Spectral Density, Middle Channel
                                                                     * RBW 3 kHz    Marker 1 [T1 ]
                                                                     * VBW 10 kHz               5.16 dBm
                      Ref    34 dBm              * Att   20 dB        SWT 100 ms       925.050584936 MHz

                            Offset    10.5 dB
                      30

                                                                                                             A

                      20
               1 PK
               MAXH
                                                                                                            LVL
                      10
                                                             1


                      0



                      -10



                      -20
                                                                                                            3DB


                      -30



                      -40



                      -50



                      -60


                      Center   925.1 MHz                     88.1 kHz/                     Span   881 kHz




              Date: 13.APR.2018       23:52:45




FCC Part 15.247                                                                                                    Page 29 of 30


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                 Report No.: RSZ180322002-00

                                           Power Spectral Density, High Channel
                                                                  * RBW 3 kHz    Marker 1 [T1 ]
                                                                  * VBW 10 kHz               6.07 dBm
                      Ref    34 dBm              * Att   20 dB      SWT 100 ms      927.444937500 MHz

                            Offset    10.5 dB
                      30

                                                                                                          A

                      20
               1 PK
               MAXH
                                                                                                         LVL
                      10                                     1


                      0



                      -10



                      -20
                                                                                                         3DB


                      -30



                      -40



                      -50



                      -60


                      Center   927.5 MHz                     88.1 kHz/                  Span   881 kHz




              Date: 13.APR.2018       23:38:50




                                                    ***** END OF REPORT *****




FCC Part 15.247                                                                                                 Page 30 of 30



Document Created: 2018-05-10 09:33:48
Document Modified: 2018-05-10 09:33:48

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC