RF Exposure

FCC ID: 2AF6B-RAK7258

RF Exposure Info

Download: PDF
FCCID_4274857

Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ190308005-00B

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                  Limits for General Population/Uncontrolled Exposure

                                 Limits for General Population/Uncontrolled Exposure
             Frequency             Electric Field     Magnetic Field        Power           Averaging
               Range                  Strength           Strength          Density            Time
               (MHz)                   (V/m)              (A/m)           (mW/cm2)          (Minutes)
                 0.3-1.34               614                   1.63        *(100)                 30
                 1.34-30               824/f                 2.19/f      *(180/f2)               30
                 30-300                 27.5                 0.073            0.2                30
               300-1500                     /                  /          f/1500                 30
           1500-100,000                     /                  /              1.0                30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                              PG
                                                        S=
                                                             4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


                            Antenna Gain        Conducted Power       Evaluation         Power
   Frequency                                                                                          MPE Limit
                                                                       Distance         Density
     (MHz)            (dBi)       (numeric)     (dBm)         (mW)                                    (mW/cm2)
                                                                        (cm)           (mW/cm2)
   2412-2472           3.0           2.0         17.5         56.23      20               0.02             1
   923.3-927.5         2.0           1.58         13          19.95      20              0.006            0.6




FCC Part 15.247                                                                                       Page 13 of 72


Bay Area Compliance Laboratories Corp. (Shenzhen)                       Report No.: RSZ190308005-00B

 Consider the LoRa and WIFI transmitting simultaneously:

 The ratio= MPE/LimitLoRa+ MPE/LimitWIFI =0.006/0.6+0.02/1=0.03<1.0

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
from nearby persons.

Result: Compliance




FCC Part 15.247                                                                         Page 14 of 72



Document Created: 2019-05-16 16:18:27