                            MPE TEST REPORT

               Applicant            Quectel Wireless Solutions Co., Ltd

               FCC ID               XMR201807EG95NA

               Product              LTE Module

               Brand                Quectel

               Model                EG95-NA

               Report No.           R1805A0249-M1V1

               Issue Date           July 17, 2018




TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance
with the requirements as documented in this report.




                  Performed by: Jiangpeng Lan                    Approved by: Kai Xu




               TA Technology (Shanghai) Co., Ltd.
                  No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86-021-50791141/2/3
                                     FAX: +86-021-50791141/2/3-8000


          MPE Test Report                                                                                      Report No: R1805A0249-M1V1




                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 3
 1.1    Notes of the Test Report ......................................................................................................... 3
 1.2    Test facility .............................................................................................................................. 3
 1.3    Testing Location ...................................................................................................................... 4
 1.4    Laboratory Environment .......................................................................................................... 4
2 Description of Equipment under Test .............................................................................................. 5
3 Maximum conducted output power (measured) and antenna Gain ................................................ 6




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 2 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                        Report No: R1805A0249-M1V1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above.


1.2 Test facility

CNAS (accreditation number:L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 3 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                        Report No: R1805A0249-M1V1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




1.4 Laboratory Environment

   Temperature                                             Min. = 18C, Max. = 25 C

   Relative humidity                                       Min. = 30%, Max. = 70%

   Ground system resistance                                < 0.5 
   Ambient noise is checked and found very low and in compliance with requirement of standards.
   Reflection of surrounding objects is minimized and in compliance with requirement of standards.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 4 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                        Report No: R1805A0249-M1V1



2 Description of Equipment under Test

 Client Information
   Applicant                           Quectel Wireless Solutions Co., Ltd
                                       7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
   Applicant address
                                       Shanghai 200233, China
   Manufacturer                        Quectel Wireless Solutions Co., Ltd
                                       7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
   Manufacturer address
                                       Shanghai 200233, China


General Technologies
   Model                               EG95-NA
   SN                                  869394030001009
   Hardware Version                    R1.0
   Software Version                    EG95NAFBR05A03M4G
   Date of Testing:                    May 25, 2018 ~ June 27, 2018




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 5 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                        Report No: R1805A0249-M1V1



3 Maximum conducted output power (measured) and antenna Gain

The numeric gain (G) of the antenna with a gain specified in dB is determined by
Numeric gain (G)=10^(antenna gain/10)



                                         Maximum Conducted Output
                                                                                     Antenna Gain
               Band                              Power                                                       Numeric gain
                                                                                         (dBi)
                                             (dBm)                 (mW)
        WCDMA Band II                         25.00               316.23                   4.00                   2.51
       WCDMA Band IV                          25.00               316.23                   4.00                   2.51
       WCDMA Band V                           25.00               316.23                   4.00                   2.51
           LTE Band 2                         25.00               316.23                   4.00                   2.51
           LTE Band 4                         25.00               316.23                   4.00                   2.51
           LTE Band 5                         25.00               316.23                   4.00                   2.51
          LTE Band 12                         25.00               316.23                   4.00                   2.51
          LTE Band 13                         25.00               316.23                   4.00                   2.51




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 6 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                        Report No: R1805A0249-M1V1

         According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible exposure

         (MPE) are as following




Note1. Occupational/controlled limits apply in situations in which persons are exposed as a consequence of

       their employment provided those persons are fully aware of the potential for exposure and can

       exercise control over their exposure. Limits for occupational/controlled exposure also apply in

       situations when an individual is transient through a location where occupational / controlled limits apply

       provided he or she is made aware of the potential for exposure.

Note2: General population/uncontrolled exposures apply in situations in which the general public may be

       exposed, or in which persons that are exposed as a consequence of their employment may not be fully

       aware of the potential for exposure or can not exercise control over their exposure.




     TA Technology (Shanghai) Co., Ltd.                                                                                  Page 7 of 9
     This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No: R1805A0249-M1V1
    The maximum permissible exposure for 300~1500 MHz is f/1500, for 1500~100,000MHz is 1.0.So



                         Band                                    The maximum permissible exposure


                      WCDMA II                                                     1.0mW/cm2

                     WCDMA IV                                                      1.0mW/cm2

                     WCDMA V                                                      0.55mW/cm2

                     LTE Band 2                                                    1.0mW/cm2

                     LTE Band 4                                                    1.0mW/cm2

                     LTE Band 5                                                   0.55mW/cm2

                    LTE Band 12                                                   0.47mW/cm2

                    LTE Band 13                                                   0.52mW/cm2



 IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the

antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20

cm from all persons and must not be co-located or operating in conjunction with any other antenna

or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or

the device could result in the device exceeding the RF exposure requirements and void user’s

authority to operate the device.




 TA Technology (Shanghai) Co., Ltd.                                                                                  Page 8 of 9
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                        Report No: R1805A0249-M1V1




RF Exposure Calculations:
 The following information provides the minimum separation distance for the highest gain antenna

 provided. This calculation is based on the conducted power, considering maximum power and antenna

 gain. The formula shown in KDB 447498 D01 is used in the calculation.

Equation from KDB 447498 D01 General RF Exposure Guidance v06 (10/23/2015) is:
                                                                        2
                                                        S= PG / 4∏R
                                                                              2
 Where:     S = power density (in appropriate units, e.g. mW/cm )

           P = Time-average maximum tune up procedure (in appropriate units, e.g., mW)

           G = the numeric gain of the antenna

           R = distance to the center of radiation of the antenna (20 cm = limit for MPE)



                                                                     Test Result            Limit Value
                             Band                 PG (mW)                          2                    2
                                                                      (mW/cm )               (mW/cm )
                      WCDMA Band II                794.33                   0.16                 1.00
                     WCDMA Band IV                 794.33                   0.16                 1.00
                      WCDMA Band V                 794.33                   0.16                 0.55
                         LTE Band 2                794.33                   0.16                 1.00
                         LTE Band 4                794.33                   0.16                 1.00
                         LTE Band 5                794.33                   0.16                 0.55
                        LTE Band 12                794.33                   0.16                 0.47
                        LTE Band 13                794.33                   0.16                 0.52
                    Note: R = 20cm
                         ∏= 3.1416


 Note: For transmitters, minimum separation distance is 20cm, even if calculations indicate MPE
       distance is less.