Test Report

FCC ID: 2AEVM1008900

Test Report

Download: PDF
FCCID_4435492

MerchSource, LLC.
TEST REPORT
SCOPE OF WORK
FCC TESTING–1008900

REPORT NUMBER
190611074SZN-001

ISSUE DATE            [REVISED DATE]

23 AUGUST 2019        [---------------------]

PAGES
20


DOCUMENT CONTROL NUMBER
FCC ID 209_b
© 2017 INTERTEK


                                                                             101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community,
                                                                             GuanHu Subdistrict, LongHua District, ShenZhen.
                                                                             Tel: (86 755) 8601 6288
                                                                             Fax: (86 755) 8601 6751
                                                                             www.intertek.com
  TEST REPORT
                                                                                                Intertek Report No.: 190611074SZN-001




                                                           MerchSource, LLC.

                                                                 Application
                                                                     For
                                                                 Certification

                                                       FCC ID: 2AEVM1008900

                                              Charging Stand Wireless 10 Watt

                                                              Model: 1008900

                                                  Brand Name: Sharper Image

                                                                 Transmitter

                                                Report No.: 190611074SZN-001

We hereby certify that the sample of the above item is considered to comply with the requirements
                         of FCC Part 15, Subpart C for Intentional Radiator,
                                      mention 47 CFR [10-1-18]


Prepared and Checked by:                                                    Approved by:




Winkey Wang                                                                   Kidd Yang
Senior Project Engineer                                                       Technical Supervisor
                                                                              Date: 23 August 2019


This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the
Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to
permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or
advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report
are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek
certification program.


                                     Intertek Testing Services Shenzhen Ltd. Longhua Branch
                   101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                                     Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751

Version: 01-November-2017                                   Page: 1 of 20                                                        FCC ID 209_b


  TEST REPORT                                                             Intertek Report No.: 190611074SZN-001




                              MEASUREMENT/TECHNICAL REPORT



      This report concerns (check one)       Original Grant        X          Class II Change

      Equipment Type: DCD - Part 15 Low Power Transmitter Below 1705 kHz



      Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?        Yes            No     X

                                                                    If yes, defer until :
                                                                                                date
      Company Name agrees to notify the Commission by:
                                                                          date

      of the intended date of announcement of the product so that the grant can be issued on that
      date.


      Transition Rules Request per 15.37?                               Yes             No         X

      If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR                  [10-01-18]
      Edition] provision.


      Report prepared by:
                                             Winkey Wang
                                             Intertek Testing Services Shenzhen Ltd. Longhua Branch
                                             101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing
                                             Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                             Tel: (86 755) 8614 0743 Fax: (86 755) 8601 6751




Version: 01-November-2017                         Page: 2 of 20                                        FCC ID 209_b


  TEST REPORT                                                                        Intertek Report No.: 190611074SZN-001




                                                    Table of Contents

1.0     Summary of Test Results ........................................................................................... 4
2.0     General Description .................................................................................................. 5
  2.1     Product Description ................................................................................................ 5
  2.2     Related Submittal(s) Grants ..................................................................................... 5
  2.3     Test Methodology .................................................................................................. 5
  2.4     Test Facility ........................................................................................................... 5
3.0     System Test Configuration ......................................................................................... 6
  3.1     Justification ........................................................................................................... 6
  3.2     EUT Exercising Software .......................................................................................... 6
  3.3     Special Accessories ................................................................................................. 6
  3.4     Equipment Modification ......................................................................................... 6
  3.5     Measurement Uncertainty ...................................................................................... 7
  3.6     Support Equipment List and Description .................................................................. 7
4.0     Measurement Results ............................................................................................... 8
  4.1     Field Strength Calculation ........................................................................................ 8
  4.2     Radiated Emission Configuration Photograph ............................................................ 9
  4.3     Radiated Spurious Emission ..................................................................................... 9
  4.4     Conducted Emission Configuration Photograph ....................................................... 13
  4.5     Conducted Emission ............................................................................................. 13
5.0     Equipment Photographs .......................................................................................... 16
6.0     Product Labelling .................................................................................................... 16
7.0     Technical Specifications ........................................................................................... 16
8.0     Instruction Manual ................................................................................................. 16
9.0     Miscellaneous Information ...................................................................................... 17
  9.1 20dB Bandwidth ....................................................................................................... 17
  9.2 Emissions Test Procedures..................................................................................... 18
  9.2 Emissions Test Procedures (cont'd) ......................................................................... 19
10.0      Test Equipment List ............................................................................................. 20




Version: 01-November-2017                                     Page: 3 of 20                                         FCC ID 209_b


  TEST REPORT                                                          Intertek Report No.: 190611074SZN-001



1.0    Summary of Test Results

        Applicant:            MerchSource, LLC.
        Address:              7755 Irvine Center Drive, Suite 100, Irvine, California, United States


        Manufacturer:         Same as Applicant

        Address:              Same as Applicant
        Model:                1008900
        FCC ID:               2AEVM1008900



                            TEST ITEM                           REFERENCE                   RESULTS
        Power Line Conducted Emissions                              15.207                    Pass
        Transmitter Radiated Emissions                              15.209                   Pass
                                                                                             Pass
        Antenna Requirement                                         15.203
                                                                                          (See Notes)

      Notes:
      The EUT uses an Integral Antenna which in accordance to Section 15.203 is considered
      sufficient to comply with the provisions of this section.




Version: 01-November-2017                           Page: 4 of 20                            FCC ID 209_b


  TEST REPORT                                                        Intertek Report No.: 190611074SZN-001

2.0 General Description

2.1 Product Description

     The Equipment Under Test (EUT) is a Charging Stand Wireless 10 Watt with WPT function
     operating at 110-205 kHz. The EUT is powered by Input 5.3Vdc/2A or 9V/1.7A via USB port
     through adapter. For more detailed features description, please refer to the user’s manual.

     Antenna Type: Integral Antenna(embedded coil antenna)
     Antenna Peak Gain: 0dBi

     For electronic filing, the brief circuit description is saved with filename: descri.pdf.

2.2 Related Submittal(s) Grants

     This is an application for certification of DCD- Part 15 Low Power Transmitter Below 1705 kHz.

2.3 Test Methodology

     Both AC mains line-conducted and radiated emission measurements were performed according
     to the procedures in ANSI C63.10 (2013). Radiated emission measurement was performed in
     Semi-anechoic chamber and conducted emission measurement was performed in shield
     room. For radiated emission measurement, preliminary scans were performed in the semi-
     anechoic chamber only to determine the worst-case modes. All radiated tests were
     performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the
     "Justification Section" of this Application. All other measurements were made in accordance
     with the procedures in part 2 of CFR 47.

2.4 Test Facility

     The Semi-Anechoic chamber and shield room used to collect the radiated data and conducted
     data are Intertek Testing Services Shenzhen Ltd. Longhua Branch and located at 101, 201,
     Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua
     District, ShenZhen. This test facility and site measurement data have been fully placed on file
     with File Number: CN1188.




Version: 01-November-2017                          Page: 5 of 20                                FCC ID 209_b


  TEST REPORT                                                    Intertek Report No.: 190611074SZN-001

3.0 System Test Configuration

3.1 Justification

      The system was configured for testing in a typical fashion (as a customer would normally use
      it), and in the confines as outlined in ANSI C63.10 (2013). the WPT source device was tested
      with one typical WPT client device of models for which it is designed, they are operated such
      that the EUT transmits at the maximum output power.

      The EUT was powered by AC 120V/60Hz during the test. The test system was pre-scanning
      tested based on the consideration of following EUT operation mode. Only the worst-case data
      is shown in the report.
          Pertest mode    Description
            Mode 1        Charge with Mobile phone at 1% battery power
            Mode 2        Charge with Mobile phone at 50% battery power
            Mode 3        Charge with Mobile phone at 99% battery power
            Mode 4        Charge with test fixture(10W)
      Note: Test fixtures simulate a phone's ability to receive signals and be charged in the set
      power

      For maximizing emissions below 30 MHz, the EUT was rotated through 360°, the centre of the
      loop antenna was placed 1 meter above the ground, and the antenna polarization was
      vertically installed. For maximizing emission at and above 30 MHz, the EUT was rotated
      through 360°, the antenna height was varied from 1 meter to 4 meters above the ground
      plane, and the antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data report in Section 4.0.

       The rear of unit shall be flushed with the rear of the table.

      The equipment under test (EUT) was configured for testing in a typical fashion (as a customer
      would normally use it). The EUT was mounted to a plastic stand if necessary and placed on the
      styrene turntable, which enabled the engineer to maximize emissions through its placement in
      the three orthogonal axes.

3.2   EUT Exercising Software
      N/A

3.3 Special Accessories

      There is no special accessories necessary for compliance of this product.

3.4    Equipment Modification

       Any modifications installed previous to testing by MerchSource, LLC. will be incorporated in
       each production model sold / leased in the United States.

      No modifications were installed by Intertek Testing Services Shenzhen Ltd. Longhua Branch.

Version: 01-November-2017                       Page: 6 of 20                          FCC ID 209_b


  TEST REPORT                                                   Intertek Report No.: 190611074SZN-001

3.5 Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test has been
      considered.

3.6 Support Equipment List and Description

      This product was tested in the following configuration:

                 Description             Manufacturer                        Detail
                 Test fixture
                                     (Provided by applicant)          5W/7.5W/10W/15W
           (Provided by Applicant)
                  USB cable
                                     (Provided by applicant)            unshielded, 1.0m
           (Provided by Applicant)
                Mobile phone
                                           SAMSUNG                             S7
            (Provided by Intertek)
                                                                         Model: AD07ZM
                  Adapter                                       Output: Input 100-240V~, 50/60Hz,
                                             xiaomi
           (Provided by Applicant)                                 Output 5Vdc/3A, 9Vdc/2A,
                                                                           12Vdc/1.5A




Version: 01-November-2017                      Page: 7 of 20                            FCC ID 209_b


  TEST REPORT                                                      Intertek Report No.: 190611074SZN-001

4.0      Measurement Results

4.1     Field Strength Calculation

        The field strength is calculated by adding the reading on the Spectrum Analyzer to the
        factors associated with preamplifiers (if any), antennas, cables, pulse desensitization and
        average factors (when specified limit is in average and measurements are made with peak
        detectors). A sample calculation is included below.

        FS = RA + AF + CF − AG + PD + AV

        where FS      =     Field Strength in dBV/m
              RA      =     Receiver Amplitude (including preamplifier) in dBV
              CF      =     Cable Attenuation Factor in dB
              AF      =     Antenna Factor in dB
              AG      =     Amplifier Gain in dB
              PD      =     Pulse Desensitization in dB
              AV      =     Average Factor in −dB

        In the radiated emission table which follows, the reading shown on the data table may
        reflect the preamplifier gain. An example of the calculations, where the reading does not
        reflect the preamplifier gain, follows:

        FS = RA + AF + CF − AG + PD + AV

        Example

        Assume a receiver reading of 62.0dBV is obtained. The antenna factor of 7.4dB and
        cable factor of 1.6dB is added. The amplifier gain of 29dB is subtracted. The pulse
        desensitization factor of the spectrum analyzer was 0dB, and the resultant average factor
        was −10dB. The net field strength for comparison to the appropriate emission limit is
        32dBV/m. This value in dBV/m was converted to its corresponding level in V/m.

        RA       =    62.0dBV
        AF       =    7.4dB
        CF       =    1.6dB
        AG       =    29.0dB
        PD       =    0dB

        AV       =    −10dB

        FS       =    62 + 7.4 + 1.6 − 29 + 0 + (−10) = 32dBV/m

        Level in V/m = Common Antilogarithm [(32dBV/m)/20] = 39.8V/m




Version: 01-November-2017                         Page: 8 of 20                          FCC ID 209_b


  TEST REPORT                                                 Intertek Report No.: 190611074SZN-001

4.2     Radiated Emission Configuration Photograph

        For electronic filing, the worst case radiated emission configuration photographs are saved
        with filename: test setup photos.pdf.

4.3    Radiated Spurious Emission

                              Worst Case Radiated Spurious Emission
                                               at
                                         48.244840MHz

                              Judgement:     Passed by 1.4dB margin




Version: 01-November-2017                     Page: 9 of 20                         FCC ID 209_b


  TEST REPORT                                                                  Intertek Report No.: 190611074SZN-001

 Applicant: MerchSource, LLC.
 Date of Test: 22 August 2019                                                           Model: 1008900
 Worst Case Operating Mode: Charge with test fixture(10W)


ANT Polarity: Horizontal
     Level in dB礦/m




          Frequency   QuasiPeak   Meas.    Bandwidth   Height   Polarization     Corr.    Margin -   Limit - QPK
            (MHz)     (dBuV/m)     Time      (kHz)      (cm)                     (dB)      QPK        (dBuV/m)
                                   (ms)                                                    (dB)
         99.904667      38.7      1000.0    120.000    100.0         H           10.6       4.8         43.5
        173.042667      36.4      1000.0    120.000    100.0         H           12.5       7.1         43.5
        292.223333      37.7      1000.0    120.000    100.0         H           16.7       8.3         46.0


    Remark:
    1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)
    2. QuasiPeak (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV)
    3. Margin (dB) = Limit Line(dBμV/m) – Level (dBμV/m)




Version: 01-November-2017                              Page: 10 of 20                                          FCC ID 209_b


  TEST REPORT                                                                       Intertek Report No.: 190611074SZN-001

Applicant: MerchSource, LLC.
Date of Test: 22 August 2019                                                             Model: 1008900
Worst Case Operating Mode: Charge with test fixture(10W)



ANT Polarity: Vertical
    Level in dB礦/m




               Frequency   QuasiPeak   Meas.    Bandwidth   Height   Polarization     Corr.   Margin -   Limit - QPK
                 (MHz)     (dBuV/m)     Time      (kHz)      (cm)                     (dB)     QPK        (dBuV/m)
                                        (ms)                                                   (dB)
               33.039333     36.3      1000.0    120.000    100.0         V           16.8      3.7         40.0
               46.171800     37.6      1000.0    120.000    100.0         V           10.0      2.4         40.0
               48.244840     38.6      1000.0    120.000    100.0         V           8.9       1.4         40.0


   Remark:
   1. Corr. = Antenna Factor (dB/m) + Cable Loss (dB)
   2. QuasiPeak (dBμV/m)= Corr. (dB/m)+ Read Level (dBμV)
   3. Margin (dB) = Limit Line(dBμV/m) – Level (dBμV/m)




Version: 01-November-2017                                   Page: 11 of 20                                         FCC ID 209_b


   TEST REPORT                                                        Intertek Report No.: 190611074SZN-001


Applicant: MerchSource, LLC.
Date of Test: 22 August 2019                                                Model: 1008900
Worst Case Operating Mode: Charge with test fixture(10W)



                            Fundamental & Spurious Emission Below 30MHz

                                      Pre-    Corr.
                            Reading                        Net       Distance   Calulated      Limit   Margin
               Frequency              Amp    Factor
Polarization                (dBµV)                        at 3m       Factor     at 300m     at 300m    (dB)
                 (MHz)                Gain    (dB)
                                                        (dBµV/m)       (-dB)    (dBµV/m)    (dBµV/m)
                                      (dB)

  Vertical       0.137       88.0     0.0     7.1          95.1        80         15.1        24.9       -9.8
  Vertical       0.274       65.4     0.0     6.5          71.9        80         -8.1        18.8      -26.9


                                      Pre-    Corr.
                            Reading                        Net       Distance   Calulated     Limit    Margin
               Frequency              Amp    Factor
Polarization                (dBµV)                        at 3m       Factor     at 30m      at 30m     (dB)
                 (MHz)                Gain    (dB)
                                                        (dBµV/m)       (-dB)    (dBµV/m)    (dBµV/m)
                                      (dB)

  Vertical       0.685       57.3     0.0     6.1          63.4        40         23.4        30.9       -7.5



Notes:
1. The specified limits of frequency band 9~90 KHz, 110~490 KHz are in average and measurements
are made with peak detectors. Quasi-Peak detector is used for other frequency band.

2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3-meter
distance were measured at 0.3-meter and an inverse proportional extrapolation was performed to
compare the signal level to the 3-meter limit. No other harmonic emissions than those reported
were detected at a test distance of 0.3-meter.

 3. Negative value in the margin column shows emission below limit.

4. Loop antenna is used for the emission under 30MHz.




Version: 01-November-2017                           Page: 12 of 20                            FCC ID 209_b


  TEST REPORT                                                  Intertek Report No.: 190611074SZN-001

4.4     Conducted Emission Configuration Photograph

        For electronic filing, the worst case radiated emission configuration photographs are saved
        with filename: test setup photos.pdf.

4.5    Conducted Emission

                               Worst Case Conducted Configuration
                                              at
                                         0.414000MHz

                              Judgement:     Passed by 0.8dB margin




Version: 01-November-2017                     Page: 13 of 20                          FCC ID 209_b


  TEST REPORT                                                                   Intertek Report No.: 190611074SZN-001

Applicant: MerchSource, LLC.
Date of Test: 02 August, 2019                                                             Model: 1008900
Worst Case Operating Mode: Charge with mobile phone
Phase: Live




                                                Graphic / Data Table

                                                Conducted Emissions
                                   Pursuant to FCC 15.207: Emissions Requirement
        Level in dBμ




Limit and Margin QP
  Frequency            QuasiPeak   Bandwidth   Line   Corr.   Margin    Limit
     (MHz)              (dBuV)       (kHz)            (dB)     (dB)    (dBuV)
   0.414000              46.9        9.000      L1     9.8     10.7     57.6
   0.554000              43.3        9.000      L1     9.8     12.7     56.0
   0.590000              37.7        9.000      L1     9.8     18.3     56.0
   0.690000              41.1        9.000      L1     9.8     14.9     56.0
  12.838000              44.1        9.000      L1    10.1     15.9     60.0
  13.114000              44.3        9.000      L1    10.1     15.7     60.0


Limit and Margin AV
  Frequency            Average     Bandwidth   Line   Corr.   Margin    Limit
     (MHz)             (dBuV)        (kHz)            (dB)     (dB)    (dBuV)
   0.414000             46.8         9.000     L1      9.8      0.8     47.6
   0.554000             41.2         9.000     L1      9.8      4.8     46.0
   0.590000             36.8         9.000     L1      9.8      9.2     46.0
   0.690000             41.1         9.000     L1      9.8      4.9     46.0
  12.838000             43.9         9.000     L1     10.1      6.1     50.0
  13.114000             44.0         9.000     L1     10.1      6.0     50.0




Version: 01-November-2017                                     Page: 14 of 20                           FCC ID 209_b


  TEST REPORT                                                                   Intertek Report No.: 190611074SZN-001


Applicant: MerchSource, LLC.
Date of Test: 02 August, 2019                                                             Model: 1008900
Worst Case Operating Mode: Charge with mobile phone
Phase: Neutral




                                                Graphic / Data Table

                                                Conducted Emissions
                                   Pursuant to FCC 15.207: Emissions Requirement
        Level in dBμ




Limit and Margin QP
  Frequency            QuasiPeak   Bandwidth   Line   Corr.   Margin    Limit
     (MHz)              (dBuV)       (kHz)            (dB)     (dB)    (dBuV)
   0.414000              46.7        9.000       N     9.8     10.9     57.6
   0.554000              42.2        9.000       N     9.8     13.8     56.0
   0.690000              40.3        9.000       N     9.8     15.7     56.0
  11.734000              41.7        9.000       N    10.1     18.3     60.0
  12.838000              43.4        9.000       N    10.2     16.6     60.0
  13.394000              43.8        9.000       N    10.2     16.2     60.0


Limit and Margin AV
  Frequency            Average     Bandwidth   Line   Corr.   Margin    Limit
     (MHz)             (dBuV)        (kHz)            (dB)     (dB)    (dBuV)
   0.414000             46.6         9.000      N      9.8      1.0     47.6
   0.554000             41.3         9.000      N      9.8      4.7     46.0
   0.690000             40.3         9.000      N      9.8      5.7     46.0
  11.734000             40.5         9.000      N     10.1      9.5     50.0
  12.838000             42.1         9.000      N     10.2      7.9     50.0
  13.394000             42.0         9.000      N     10.2      8.0     50.0




Version: 01-November-2017                                     Page: 15 of 20                           FCC ID 209_b


  TEST REPORT                                                     Intertek Report No.: 190611074SZN-001



5.0 Equipment Photographs

      For electronic filing, the photographs are saved with filename: external photos.pdf & internal
      photos.pdf.


6.0 Product Labeling

      For electronic filing, the FCC ID label artwork and location is saved with filename: label.pdf.



7.0 Technical Specifications

      For electronic filing, the block diagram and circuit diagram are saved with filename: block.pdf
      and circuit.pdf respectively.


8.0 Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with filename:
      manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the United States.




Version: 01-November-2017                       Page: 16 of 20                             FCC ID 209_b


  TEST REPORT                                                 Intertek Report No.: 190611074SZN-001

9.0     Miscellaneous Information

        This miscellaneous information includes 20dB bandwidth and emission measuring
        procedure.

9.1     20dB bandwidth
        Pursuant to FCC part 15 Section 15.215(c), the 20dB bandwidth of the emission was
        contained within the frequency band designated (mentioned as above) which the EUT
        operated. The effects, if any, from frequency sweeping, frequency hopping, other
        modulation techniques and frequency stability over excepted variations in temperature and
        supply voltage were considered. The test plots are reported as below.




Version: 01-November-2017                    Page: 17 of 20                          FCC ID 209_b


  TEST REPORT                                                  Intertek Report No.: 190611074SZN-001



9.2     Emissions Test Procedures

        The following is a description of the test procedure used by Intertek Testing Services in the
        measurements of transmitters operating under Part 15, Subpart C rules.

        The test set-up and procedures described below are designed to meet the requirements of
        ANSI C63.10 - 2013.

        The transmitting equipment under test (EUT) is placed on a styrene turntable which is four
        feet in diameter and approximately 0.8 meter in height above the ground plane. During the
        radiated emissions test, the turntable is rotated and any cables leaving the EUT are
        manipulated to find the configuration resulting in maximum emissions. The EUT is adjusted
        through all three orthogonal axes to obtain maximum emission levels. The antenna height
        and polarization are varied during the testing to search for maximum signal levels.

        Average detector is used for 9–90 KHz, 110–490 KHz and Quasi-Peak detector is used for
        other frequency band. The IF bandwidth used for measurement of radiated signal strength
        was 10 KHz for emission below 30 MHz and 120 KHz for emission from 30 MHz to 1000 MHz.

        The frequency range scanned is from the lowest radio frequency signal generated in the
        device which is greater than 9 kHz up to the 1GHz. For line-conducted emissions, the range
        scanned is 150kHz to 30MHz.




Version: 01-November-2017                     Page: 18 of 20                           FCC ID 209_b


  TEST REPORT                                                    Intertek Report No.: 190611074SZN-001

9.2     Emissions Test Procedures (cont'd)

        The EUT is warmed up for 15 minutes prior to the test.

        AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental
        emission field strength is recorded. If battery powered, a new, fully charged battery is
        used.

        Conducted measurements are made as described in ANSI C63.10 - 2013.

        The IF bandwidth used for measurement of radiated signal strength was 10 kHz for emission
        below 30 MHz and 120 kHz for emission from 30 MHz to 1000 MHz. Where pulsed
        transmissions of short enough pulse duration warrant, a greater bandwidth is selected
        according to the recommendations of Hewlett Packard Application Note 150-2. A discussion
        of whether pulse desensitivity is applicable to this unit is included in this report.

        Transmitter measurements are normally conducted at a measurement distance of three
        meters. However, to assure low enough noise floor in the restricted bands, signals are
        acquired at a distance of one meter or less. All measurements are extrapolated to three
        meters using inverse scaling, but those measurements taken at a closer distance are so
        marked.




Version: 01-November-2017                     Page: 19 of 20                            FCC ID 209_b


  TEST REPORT                                                             Intertek Report No.: 190611074SZN-001



10.0    Test Equipment List

Equipment
                Equipment     Manufacturer      Model No.      Serial No.          Cal. Date       Due Date
   No.
                 BiConiLog
 SZ061-12                          ETS           3142E         00166158          14-Sep-2018     14-Sep-2019
                 Antenna
 SZ185-01      EMI Receiver        R&S            ESCI             100547         4-Jan-2019      4-Jan-2020
                Active Loop
 SZ061-06                     Electro-Metrics   EM-6876             217          24-May-2019     24-May-2020
                 Antenna
                 Spectrum
 SZ056-03                          R&S           FSP 30            101148        28-May-2019     28-May-2020
                 Analyzer
                   Signal
 SZ056-06                          R&S           FSV 40            101101        28-May-2019     28-May-2020
                 Analyzer
                 Anechoic                       RFD-F/A-
 SZ188-01                          ETS                             4102          15-Dec-2018     15-Dec-2020
                 Chamber                          100
 SZ062-02        RF Cable        RADIALL        RG 213U              --          19-Jun-2019     19-Dec-2019
                                                 0.04-
 SZ062-05        RF Cable        RADIALL                             --          23-Feb-2019     23-Aug-2019
                                                26.5GHz
                                                 0.04-
 SZ062-12        RF Cable        RADIALL                             --          23-Feb-2019     23-Aug-2019
                                                26.5GHz
                 EMI Test
 SZ185-02                          R&S            ESCI             100692        26-Oct-2018     26-Oct-2019
                 Receiver
                Two-Line V-
 SZ187-02                          R&S           ENV216            100073        28-May-2019     28-May-2020
                 Network
                 Shielding
 SZ188-03                          ETS          RFD-100            4100          16-Jan-2018      16-Jan-2020
                  Room
                              HUBER+SUHNE       CBL2-BN-       110127-
 SZ062-16        RF Cable                                                        29-Oct-2018     29-Oct-2019
                                   R              1m           2231000


****************************************End of Report**************************************




Version: 01-November-2017                         Page: 20 of 20                                 FCC ID 209_b



Document Created: 2019-09-03 19:52:15
Document Modified: 2019-09-03 19:52:15

© 2024 FCC.report