RF Exposure

FCC ID: 2AEVM1008899

RF Exposure Info

Download: PDF
FCCID_4280360

MerchSource, LLC

TEST REPORT
SCOPE OF WORK
SAR ASSESSMENT–1008899

REPORT NUMBER
190314009SZN-002

ISSUE DATE         [REVISED DATE]

27 MARCH 2019            [---------------------]

PAGES
4


DOCUMENT CONTROL NUMBER
RF Exposure
© 2017 INTERTEK


                                                                            101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community,
                                                                            GuanHu Subdistrict, LongHua District, ShenZhen.
                                                                            Tel: (86 755) 8601 6288
                                                                            Fax: (86 755) 8601 6751
                                                                            www.intertek.com
    TEST REPORT

                                                                    Test Report

Applicant:                  MerchSource, LLC                                                                    Number:           190314009SZN-002

                                                                                                                Date:        27 March 2019


Sample Description
   Product                            :        Wireless Charging Pad 5 Watt
   Model No.                          :        1008899

Brand Name                           :         Sharper Image
Electrical Rating                    :         Input: DC 5V/2A; Output: DC 5V/1A

Date Received                         :        14 March 2019

Date Test Conducted                   :        14 March 2019 to 21 March 2019

Test Requested                        :        Test for compliance with CFR 47 part 1

Test Method                              :     Environmental evaluation and exposure limit according to FCC
                                               CFR 47 part 1, 1.1307(c) and (d), 1.1310

Test Result                           :        Pass

Conclusion                            :        When determining of test conclusion, measurement uncertainty of tests have
                                               been considered.
.

**************************************************** End of Page ****************************************************

Prepared and Checked By:                                                             Approved By:




Leo Li                                                                               Kidd Yang
Project Engineer                                                                     Technical Supervisor
                                                                                     Date: 27 March 2019



This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other tha n to the Client in accordance with
the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this
report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does
not imply that the material, product, or service is or has ever been under an Intertek certification program.


                                             Intertek Testing Services Shenzhen Ltd. Longhua Branch
                         101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                                            Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751

Version: 01-November-2017                                                         Page 1 of 4                                                  RF Exposure


 TEST REPORT



                                        Test Report
Test Setup Configuration




Note

- The RF exposure test is performed in the shield room.
- The test distance is between the edge of the charger and the geometric centre of probe.


Test Equipment List
    Name of instrument            Model           Manufacturer      Cal. Date       Due Date
    Exposure Level Tester     ELT-4002304/03         Narda         21-Mar-2018     21-Mar-2019
         Field Probe             HI-6105              ETS          26-Jun-2018     26-Jun-2019
     Laser Data Interface        HI-6113              ETS          26-Jun-2018     26-Jun-2019




Version: 01-November-2017                         Page 2 of 4                               RF Exposure


 TEST REPORT



Reference Limit:
Environmental evaluation and exposure limit according to FCC CFR 47 part 1,
1.1307(c) and (d), 1.1310

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
the environment impact of human exposure to radio frequency (RF) radiation.

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
   Frequency           Electric field   Magnetic Field
                                                                Power Density     Average Time
     Range               strength         Strength
                                                                  (mW/cm2)          (minutes)
     (MHz)                 (V/m)           (A/m)

                      (A) Limits for Occupational/Controlled Exposure

     0.3 – 3.0              614                 1.63                (100)*                 6

                 (B) Limits for General Population/Uncontrolled Exposure

    0.3 – 1.34              614                 1.63                (100)*              30
Note: * = Plane wave equivalent power density

Test Result:
H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the
EUT
Frequency            EUT            Probe          Probe          Probe         Probe            Probe
                                                                                                           Limits
  Range           Operation        Position       Position       Position     Position          Position
                                                                                                           (A/m)
  (MHz)            mode           Front (A/m)    Rear (A/m)     Left (A/m)   Right (A/m)       Top (A/m)
                 1% battery
0.110-0.205                         0.070          0.074           0.077        0.072           0.083       1.63
                    level
                 50% battery
0.110-0.205                         0.075          0.079           0.082        0.077           0.089       1.63
                    level
                 99% battery
0.110-0.205                         0.065          0.069           0.071        0.068           0.078       1.63
                    level

E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the
EUT
Frequency            EUT            Probe          Probe          Probe        Probe             Probe
                                                                                                           Limits
  Range           Operation        Position       Position       Position     Position          Position
                                                                                                           (V/m)
  (MHz)            mode           Front (V/m)    Rear (V/m)     Left (V/m)   Right (V/m)       Top (V/m)
                 1% battery
0.110-0.205                         0.105          0.113           0.118        0.109           0.125       614
                    level
                 50% battery
0.110-0.205                         0.113          0.121           0.127        0.117           0.132       614
                    level
                 99% battery
0.110-0.205                         0.093          0.099           0.102        0.096           0.115       614
                    level




Version: 01-November-2017                                  Page 3 of 4                               RF Exposure


 TEST REPORT



Configuration photo of the test:

For electronic filing, the RF exposure configuration photographs are saved with filename: RF
exposure photos.pdf.


     ********************************************** End of Report**********************************************




Version: 01-November-2017                                  Page 4 of 4                                   RF Exposure



Document Created: 2019-05-07 18:58:07
Document Modified: 2019-05-07 18:58:07