85191140047 FCC ID Report 27MHz rev 1

FCC ID: 2AETTEDDIE9999

Test Report

Download: PDF
FCCID_4311781

       TEST REPORT NUMBER: (8519)114-0047
                                             TEST REPORT
                    SHANTOU CHENGHAI LIANXIA EDDIE               --
    TO:                                               FAX:
                    TOYS CRAFT FACTORY
    ATTN:           --                                E-MAIL:    --
                    LIANXIA TOWN,CHENGHAI DISTRICT,SHANTOU CITY,GUANGDONG PROVINCE
    ADDRESS
                    CHINA
    TEST DATE       17 MAY, 2019---24 MAY, 2019


    MANUFACTURER OR
                                   SHANTOU CHENGHAI LIANXIA EDDIE TOYS CRAFT FACTORY
    SUPPLIER NAME


    MANUFACTURER OR                LIANXIA TOWN,CHENGHAI DISTRICT,SHANTOU
    SUPPLIER ADDRESS:              CITY,GUANGDONG PROVINCE CHINA

    SAMPLE DESCRIPTION:            PVC REMOTE CONTROL CARS SERIES
    MODEL OR STYLE
                                   RA#9044574
    NUMBER:

    RATED VOLTAGE:                 3V d.c.(“AA” Size *2)

                                   698-16, 698-21, 698-23, 698-26, 698-27, 698-35, 698-36, 698-48,
                                   698-52, 698-58, 698-73, 698-74, 698-75, 698-78, 698-68, 698-68A,
                                   698-18A, 698-30A, 698-38A, 698-39A, 698-62A, 698-28A, 698-19,
                                   698-25, 698-56, 698-69, 698-30, 698-34, 698-51, 698-61, 698-36A,
                                   698-38, 698-70, 698-18, 698-51/70, 698-18/30, 999-36, 999-14, 999-55,
    ADDITIONAL MODELS:             999-50, 999-12, 999-18, 999-550, 999-500, 999-140, 999-180, 999-181,
                                   999-360, 999-120, 999-1, 999-2, 999-3, 999-4, 999-5, 999-6, 999-7,
                                   999-8, WD999-1, WD999-2, WD999-3, WD999-4, WD999-5, WD999-6,
                                   WD999-7, WD999-8, WD999-9, WD999-10, WD999-11, WD999-12,
                                   WD999-13, WD999-14, WD999-15, WD999-16, WD999-17, WD999-18,
                                   WD999-19, WD999-20, WD999-21, WD999-22, WD999-23
    FCC ID:                        2AETTEDDIE9999

    The submitted sample of the above equipment has been tested according to following standard(s)
    FCC Rules and Regulations Part 15 Subpart C section 15.227
    ANSI C63.10:2013

    CONCLUSION: The submitted sample was found to COMPLY with the test requirement
                                                                                        Assistant Manager




                                                                                        Name: Nick Lung
                                                                                        Date: 03 JUNE, 2019

Bureau Veritas Shenzhen Co., Ltd   1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                          Tel: +86 755 8600 0151
                                   Zone of Honghualing Industrial Park,Shenzhen,               Email: http://www.bureauveritas.com
                                             Guangdong Province , China
                                                     Page 1 of 22


       TEST REPORT NUMBER: (8519)114-0047
       1. Summary of test results
              Description of Test Item                             Standard                   Results
                   Field Strength of the                    FCC Part 15: 15.227(a)
                                                                                                PASS
                   Fundamental Signal                         ANSI C63.10:2013

                                                              FCC Part 15: 15.215
                     20dB Bandwidth                                                             PASS
                                                               ANSI C63.10:2013
                                                             FCC Part 15: 15.209
                    Radiated Emission                       FCC Part 15: 15.227(b)              PASS
                                                              ANSI C63.10:2013

            Power Line Conducted Emissions                    FCC Part 15: 15.207                 N/A
                                                              ANSI C63.10:2013

                  Antenna requirement                         FCC Part 15: 15.203               PASS

        Note: N/A is an abbreviation for Not Applicable, and means this item is not applicable for this
        device.




Bureau Veritas Shenzhen Co., Ltd    1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                    Tel: +86 755 8600 0151
                                    Zone of Honghualing Industrial Park,Shenzhen,        Email: http://www.bureauveritas.com
                                              Guangdong Province , China
                                                      Page 2 of 22


       TEST REPORT NUMBER: (8519)114-0047

       2. General test information

       2.1. Description of EUT

        Power supply                : DC 3V (2*1.5V ”AA” batteries)
        Operation frequency         : 27.145MHz
        Antenna Type                : Dedicated antenna


       2.2. Accessories of EUT
         Description of                               Model
                            Manufacturer                                  Serial No.           Other
          Accessories                                number
             N/A                   N/A                 N/A                    N/A               N/A


       2.3. Assistant equipment used for test
           Assistant                                  Model
                            Manufacturer                                  Serial No.           Other
          equipment                                  number
             N/A                   N/A                 N/A                    N/A               N/A


       2.4. Block diagram of EUT configuration for test


                              EUT



       2.5. Deviations of test standard
       No Deviation.


       2.6. Test environment conditions
       During the measurement the environmental conditions were within the listed ranges:

             Temperature range:                                            21-25ȭ
               Humidity range:                                            40-75%
               Pressure range:                                           86-106kPa




Bureau Veritas Shenzhen Co., Ltd     1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                      Tel: +86 755 8600 0151
                                     Zone of Honghualing Industrial Park,Shenzhen,        Email: http://www.bureauveritas.com
                                               Guangdong Province , China
                                                       Page 3 of 22


       TEST REPORT NUMBER: (8519)114-0047
       2.7. Test laboratory
       Dongguan Dongdian Testing Service Co., Ltd
       Add: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City,
       Guangdong Province, China, 523808
       Tel: +86-0769-38826678, http://www.dgddt.com, Email: ddt@dgddt.com
       CNAS Accreditation No. L6451; A2LA Accreditation No. 3870.01
       Designation Number: CN1182; Test Firm Registration Number: 540522
       Industry Canada site registration number: 10288A-1
       Result reviewed by Centre of Testing Service (Ningbo) Co, Ltd Guangzhou Branch - a Bureau Veritas Company
       Address: Building A,No.65 Zhuji Highway, jishancun, Tianhe District , Guangzhou, China



       2.8. Measurement uncertainty
                                   Test Item                                               Uncertainty
                                   Bandwidth                                                 1.1%
                                                                                0.86dB (10MHz ≤ f < 3.6GHz);
          Peak Output Power (Conducted) (Spectrum analyzer)
                                                                                  1.38dB (3.6GHz≤ f < 8GHz)
             Peak Output Power (Conducted) (Power Sensor)                                    0.74dB
                                   Dwell Time                                                 0.6%
                                                                                0.86dB (10MHz ≤ f < 3.6GHz);
                      Conducted spurious emissions                                1.40dB (3.6GHz≤ f < 8GHz)
                                                                                  1.66dB (8GHz≤ f < 22GHz)
              Uncertainty for radio frequency (RBW<20kHz)                                   3×10-8
                                Temperature                                                  0.4ȭ
                                  Humidity                                       2%
                  Uncertainty for Radiation Emission test            4.70dB (Antenna Polarize: V)
                              (30MHz-1GHz)                           4.84dB (Antenna Polarize: H)
                 Uncertainty for Radiation Emission test                   4.10dB (1-6GHz)
                              (1GHz-18GHz)                              4.40dB (6GHz-18GHz)
           Uncertainty for Power line conduction emission test         3.32dB (150kHz-30MHz)
        Note: This uncertainty represents an expanded uncertainty expressed at approximately the
        95% confidence level using a coverage factor of k=2.




Bureau Veritas Shenzhen Co., Ltd      1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                          Tel: +86 755 8600 0151
                                      Zone of Honghualing Industrial Park,Shenzhen,            Email: http://www.bureauveritas.com
                                                Guangdong Province , China
                                                        Page 4 of 22


       TEST REPORT NUMBER: (8519)114-0047

       3. Equipment used during test
        Equipment            Manufacturer Model No. Serial No.                     Last Cal.         Cal. Interval
        RF Connected Test (Tonscend RF Measurement System)
        Spectrum analyzer    R&S           FSU26       200071                      Oct. 12, 2018 1 Year
        Wideband Radio
                             R&S           CMW500      117491                      Jun. 29, 2018 1 Year
        Communication tester
        Vector Signal
                             Agilent       E8267D      US49060192                  Oct. 12, 2018 1 Year
        Generator
        Vector Signal
                             Agilent       N5182A      MY48180737                  Jun. 29, 2018 1 Year
        Generator
        Power Sensor         Agilent       U2021XA     MY55150010                  Oct. 21, 2018 1 Year
        Power Sensor         Agilent       U2021XA     MY55150011                  Oct. 23, 2018 1 Year
                                           MPS-3005L-
        DC Power Source      MATRIS                    D813058W                    Aug. 18, 2018 1 Year
                                           3
        Attenuator           Mini-Circuits BW-S10W2 101109                         Aug. 18, 2018 1 Year
        RF Cable             Micable       C10-01-01-1 100309                      Oct. 21, 2018 1 Year
        Temp&Humi                          ZXGDJS-15
                             ZHIXIANG                  ZX170110-A                  Oct. 21, 2018 1 Year
        Programmable                       0L
        Test Software        JS Tonscend JS1120-3      Ver.2.7                     N/A               N/A
        Radiated Emission Test Chamber 1#
        EMI Test Receiver    R&S           ESU8        100316                      Oct. 12, 2018 1 Year
        Spectrum analyzer    Agilent       E4447A      MY50180031                  Jun. 29, 2018 1 Year
        Trilog Broadband
                             Schwarzbeck VULB9163 9163-462                         Nov. 09, 2018 1 Year
        Antenna
        Active Loop antenna Schwarzbeck FMZB-1519 1519-038                         Oct. 20, 2018 1 Year
        Double Ridged Horn
                             R&S           HF907       100276                      Nov. 16, 2018 1 Year
        Antenna
        Broad Band Horn
                             Schwarzbeck BBHA 9170 790                             Oct. 25, 2018 1 Year
        Antenna
        Pre-amplifier        A.H.          PAM-0118 360                            Oct. 12, 2018 1 Year
                                           TRLA-0040
        Pre-amplifier        TERA-MW                   101303                      Oct. 12, 2018 1 Year
                                           G35
                                           CP-X2+      W11.03+
        RF Cable             HUBSER                                                Oct. 21, 2018 1 Year
                                           CP-X1       W12.02
                                           SMAJ-SMA 17070133+17
        RF Cable             N/A                                                   Nov. 08, 2018 1 Year
                                           J-1M+ 11M 070131
                                           C10-01-01-1
        MI Cable             HUBSER                    1091629                     Oct. 21, 2018 1 Year
                                           M
        Test software        Audix         E3          V 6.11111b                  N/A               N/A




Bureau Veritas Shenzhen Co., Ltd   1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                           Tel: +86 755 8600 0151
                                   Zone of Honghualing Industrial Park,Shenzhen,               Email: http://www.bureauveritas.com
                                             Guangdong Province , China
                                                     Page 5 of 22


       TEST REPORT NUMBER: (8519)114-0047
       4. Radiated emission

       4.1. Block diagram of test setup
       In 3m Anechoic Chamber Test Setup Diagram for 9kHz-30MHz




       In 3m Anechoic Chamber Test Setup Diagram for below 1GHz




Bureau Veritas Shenzhen Co., Ltd   1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                   Tel: +86 755 8600 0151
                                   Zone of Honghualing Industrial Park,Shenzhen,        Email: http://www.bureauveritas.com
                                             Guangdong Province , China
                                                     Page 6 of 22


       TEST REPORT NUMBER: (8519)114-0047
       In 3m Anechoic Chamber Test Setup Diagram for frequency above 1GHz




       Note: For harmonic emissions test an appropriate high pass filter was inserted in the input port of
              AMP.


       4.2. Limit
       4.2.1 FCC 15.205 Restricted frequency band




Bureau Veritas Shenzhen Co., Ltd   1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                   Tel: +86 755 8600 0151
                                   Zone of Honghualing Industrial Park,Shenzhen,        Email: http://www.bureauveritas.com
                                             Guangdong Province , China
                                                     Page 7 of 22


       TEST REPORT NUMBER: (8519)114-0047
       4.2.2 FCC 15.209 Limit.

                   FREQUENCY                       DISTANCE                   FIELD STRENGTHS LIMIT
                        MHz                          Meters                     PV/m            dB(PV)/m
                    0.009 ~ 0.490                     300                    2400/F(kHz)      67.6-20log(F)
                    0.490 ~ 1.705                      30                   24000/F(kHz)      87.6-20log(F)
                    1.705 ~ 30.0                       30                         30              29.54
                       30 ~ 88                          3                        100               40.0
                       88 ~ 216                         3                        150               43.5
                     216 ~ 960                          3                        200               46.0
                     960 ~ 1000                         3                        500               54.0
                                                                                74.0 dB(PV)/m (Peak)
                  Above       1000                        3
                                                                               54.0 dB(PV)/m (Average)

       4.2.3 FCC 15.227(a) Limit.

                   FREQUENCY                       DISTANCE                    FIELD STRENGTHS LIMIT
                      MHz                            Meters                      PV/m        dB(PV)/m
                                                                                            80(Average)
                   26.96 ~ 27.28                          3                      10000
                                                                                             100(Peak)


       Note: (1) The emission limits shown in the above table are based on measurements employing a
       CISPR QP detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000MHz.
       Radiated emissions limits in these three bands are based on measurements employing an
       average detector.
             (2) At frequencies below 30MHz, measurement may be performed at a distance closer than
       that specified, and the limit at closer measurement distance can be extrapolated by below
       formula:
                   Limit3m(dBuV/m)= Limit30m(dBuV/m) + 40Log(30m/3m)

       4.2.3 Limit for this EUT
       All the emissions appearing within 15.205 restricted frequency bands shall not exceed the limits
       shown in 15.209 and 15.227, all the other emissions shall be at least 20dB below the
       fundamental emissions, or comply with 15.209 limits.




Bureau Veritas Shenzhen Co., Ltd     1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                      Tel: +86 755 8600 0151
                                     Zone of Honghualing Industrial Park,Shenzhen,         Email: http://www.bureauveritas.com
                                               Guangdong Province , China
                                                       Page 8 of 22


       TEST REPORT NUMBER: (8519)114-0047
       4.3. Test Procedure
       (1) EUT was placed on a non-metallic table, 80 cm above the ground plane inside a
           semi-anechoic chamber.
       (2) Test antenna was located 3m from the EUT on an adjustable mast, and the antenna used as
       below table.
                  Test frequency range                       Test antenna used
                      9kHz-30MHz                            Active Loop antenna
                      30MHz-1GHz                        Trilog Broadband Antenna
                      1GHz-18GHz               Double Ridged Horn Antenna(1GHz-18GHz)
                     18GHz-40GHz                      Horn Antenna(18GHz-40GHz)
       According ANSI C63.10:2013 clause 6.4.4.2 and 6,5.3, for measurements below 30 MHz, the
       loop antenna was positioned with its plane vertical from the EUT and rotated about its vertical
       axis for maximum response at each azimuth position around the EUT. And the loop antenna also
       be positioned with its plane horizontal at the specified distance from the EUT. The center of the
       loop is 1 m above the ground. for measurement above 30MHz, the Trilog Broadband Antenna or
       Horn Antenna was located 3m from EUT, Measurements were made with the antenna positioned
       in both the horizontal and vertical planes of Polarization, and the measurement antenna was
       varied from 1 m to 4 m. in height above the reference ground plane to obtain the maximum signal
       strength.
       (3) Below pre-scan procedure was first performed in order to find prominent frequency spectrum
       radiated emissions from 9kHz to 1GHz:
           (a) Scanning the peak frequency spectrum with the antenna specified in step (3), and the
       EUT was rotated 360 degree, the antenna height was varied from 1m to 4m (Except loop
       antenna, it’s fixed 1m above ground.)
           (b) Change work frequency or channel of device if practicable.
           (c) Change modulation type of device if practicable.
           (d) Change power supply range from 85% to 115% of the rated supply voltage
           (e) Rotated EUT though three orthogonal axes to determine the attitude of EUT arrangement
       produces highest emissions.
           Spectrum frequency from 9 kHz to 1GHz (tenth harmonic of fundamental frequency) was
           investigated, the EUT works the highest frequency in 27.145MHz, therefore the test is
           performed up to 1GHz, and there are no obvious emissions detected from 9 kHz to 30MHz,
           so below final test was performed with frequency range from 30MHz to 1GHz.
       (4) For final emissions measurements at each frequency of interest, the EUT was rotated and the
           antenna height was varied between 1m and 4m in order to maximize the emission.
           Measurements in both horizontal and vertical polarities were made and the data was recorded.
Bureau Veritas Shenzhen Co., Ltd   1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                   Tel: +86 755 8600 0151
                                   Zone of Honghualing Industrial Park,Shenzhen,        Email: http://www.bureauveritas.com
                                             Guangdong Province , China
                                                     Page 9 of 22


       TEST REPORT NUMBER: (8519)114-0047
           In order to find the maximum emission, the relative positions of equipments and all of the
           interface cables were changed according to ANSI C63.10:2013 on Radiated Emission test.
       (5) The emissions from 9kHz to 1GHz were measured based on CISPR QP detector except for
           the frequency bands 9-90kHz, 110-490kHz, for emissions from 9kHz-90kHz,110kHz-490kHz
           and above 1GHz were measured based on average detector, for emissions above 1GHz,
           peak emissions also be measured and need comply with Peak limit.
       (6) The emissions from 9 kHz to 1GHz, QP or average values were measured with EMI receiver
           with below RBW.
                                   Frequency band                             RBW
                                    9kHz-150kHz                              200Hz
                                   150kHz-30MHz                               9kHz
                                    30MHz-1GHz                               120kHz

       4.4. Test result
       PASS. (See below detailed test result)

       4.4.1 Field Strength of the Fundamental Signal

                                                       PK
                    Read      Antenna     Cable                                 Over
          Freq.                                       Result      AV Limit
                    level      Factor     Loss                                  Limit        Detector       Polarization
         (MHz)                                        Level      (dBμV/m)
                   (dBμV)      (dB/m)      (dB)                                 (dB)
                                                    (dBμV/m)
         27.145    37.65       12.03       3.63       53.31        80.00       -26.69         Peak         HORIZONTAL
         27.145    52.62       12.03       3.63       68.28        80.00       -11.72         Peak          VERTICAL
        Result: Pass
       Note: 1. Result Level = Read Level + Antenna Factor + Cable loss.
            2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit.
            3. Test setup: RBW: 100 kHz, VBW: 300 kHz, Sweep time: auto.




Bureau Veritas Shenzhen Co., Ltd        1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                              Tel: +86 755 8600 0151
                                        Zone of Honghualing Industrial Park,Shenzhen,              Email: http://www.bureauveritas.com
                                                  Guangdong Province , China
                                                          Page 10 of 22


           TEST REPORT NUMBER: (8519)114-0047
           4.4.2 Radiated Emissions

                         TR-4-E-009 Radiated Emission Test Result
  Test Site          : DDT 3m Chamber 1#                         D:\2019 RE1# Report Data\BV Report\85191140047\rf.EM6

  Test Date          : 2019-05-20                                Tested By            : Talent

  EUT                : REMOTE CONTROL CARS                       Model Number         : RA#9044574

  Power Supply : DC 3.0V                                         Test Mode            : Tx mode

  Condition          : Temp:24.5’C, Humi:55%, Press:100.1kPa Antenna/Distance         : 2018 VULB 9163 1#/3m/HORIZONTAL

  Memo               :

           Data: 1




  Item          Freq.       Read      Antenna        Cable         Result       Limit       Over     Detector      Polarization
                            Level      Factor        Loss          Level        Line        Limit
  (Mark)        (MHz)      (dBμV)       (dB/m)         dB         (dBμV/m)    (dBμV/m)       (dB)
    1          27.145       37.65       12.03         3.63          53.31         /              /     Peak       HORIZONTAL
    2           47.68       1.39        14.34         3.85          19.58       40.00      -20.42       QP        HORIZONTAL
    3          105.38       0.06        11.75         4.23          16.04       43.50      -27.46       QP        HORIZONTAL
    4          237.25       1.31        12.50         4.95          18.76       46.00      -27.24       QP        HORIZONTAL
    5          417.17       0.34        15.88         5.57          21.79       46.00      -24.21       QP        HORIZONTAL
    6          522.44       1.71        17.44         5.89          25.04       46.00      -20.96       QP        HORIZONTAL
    7          758.31       1.99        20.46         6.52          28.97       46.00      -17.03       QP        HORIZONTAL
       澳
       Note: 1. Result Level = Read Level + Antenna Factor + Cable loss.
             2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.
             3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.
Bureau Veritas Shenzhen Co., Ltd        1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                               Tel: +86 755 8600 0151
                                        Zone of Honghualing Industrial Park,Shenzhen,            Email: http://www.bureauveritas.com
                                                  Guangdong Province , China
                                                             Page 11 of 22


          TEST REPORT NUMBER: (8519)114-0047
                        TR-4-E-009 Radiated Emission Test Result
 Test Site          : DDT 3m Chamber 1#                           D:\2019 RE1# Report Data\BV Report\85191140047\rf.EM6

 Test Date          : 2019-05-20                                  Tested By             : Talent

 EUT                : REMOTE CONTROL CARS                         Model Number          : RA#9044574

 Power Supply : DC 3.0V                                           Test Mode             : Tx mode

 Condition          : Temp:24.5’C, Humi:55%, Press:100.1kPa Antenna/Distance            : 2018 VULB 9163 1#/3m/VERTICAL

 Memo               :


          Data: 2




  Item         Freq.       Read        Antenna        Cable         Result        Limit        Over      Detector       Polarization
                           Level        Factor        Loss          Level         Line         Limit
 (Mark)        (MHz)       (dBμV)       (dB/m)          dB         (dBμV/m)     (dBμV/m)        (dB)
   1          27.145       52.62        12.03          3.63          68.28          /              /       Peak          VERTICAL
   2           54.25        3.01        13.17          3.91          20.09       40.00         -19.91       QP           VERTICAL
   3          112.20        1.02        11.32          4.27          16.61       43.50         -26.89       QP           VERTICAL
   4          135.92        3.37         9.02          4.40          16.79       43.50         -26.71       QP           VERTICAL
   5          259.21        0.94        13.06          5.04          19.04       46.00         -26.96       QP           VERTICAL
   6          412.58        2.00        15.81          5.55          23.36       46.00         -22.64       QP           VERTICAL
   7          676.37        1.56        19.74          6.31          27.61       46.00         -18.39       QP           VERTICAL
          澳
          Note: 1. Result Level = Read Level + Antenna Factor + Cable loss.
               2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.
               3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.

Bureau Veritas Shenzhen Co., Ltd          1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                                    Tel: +86 755 8600 0151
                                          Zone of Honghualing Industrial Park,Shenzhen,                 Email: http://www.bureauveritas.com
                                                    Guangdong Province , China
                                                              Page 12 of 22


       TEST REPORT NUMBER: (8519)114-0047
       5. 20dB Bandwidth

       5.1. Block diagram of test setup




                                                                                        Spectrum
                                                                                        Analyzer




       5.2. Limits
       Operation within the band 26.96-27.28 MHz

       5.3. Test Procedure
       (1) Connect EUT’s antenna output to spectrum analyzer by RF cable.
       (2) The bandwidth of the fundamental frequency was measured by spectrum analyzer with 1 kHz
           RBW and 3 kHz VBW. The 20dB bandwidth is defined as the total spectrum the power of
           which is higher than peak power minus 20dB.

       5.4. Test Result
                    Freq.
                                                          Limit                                Conclusion
                   (MHz)
                                      Operation within the band 26.96-27.28
                   27.145                                                                          PASS
                                                       MHz




Bureau Veritas Shenzhen Co., Ltd   1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                          Tel: +86 755 8600 0151
                                   Zone of Honghualing Industrial Park,Shenzhen,               Email: http://www.bureauveritas.com
                                             Guangdong Province , China
                                                     Page 13 of 22


       TEST REPORT NUMBER: (8519)114-0047

       5.5. Original test data

                                                                   Graphs
                                                                                           * RBW   1 kHz   Marker 1 [T1 ]
                                                                                           * VBW   3 kHz              -2.22 dBm
                                      Ref    15 dBm               * Att   10 dB             SWT 100 ms          27.145200000 MHz

                                            Offset    14.8 dB                                              ndB [T1]    20.00 dB
                                      10                                                                   BW    7.600000000 kHz
                                                                                                           Temp 1 [T1 ndB]          A
                                                                                                                      -21.31 dBm
                                                                                       1
                               1 PK   0                                                                         27.141400000 MHz
                               VIEW
                                                                                                           Temp 2 [T1 ndB]
                                                                                                                                    LVL
                                                                                                                      -22.78 dBm
                                      -10
                                                                                                                27.149000000 MHz

                                                                                  T1
                                      -20                                                   T2




                                      -30




                                      -40
          20dB Bandwidth                                                                                                            3DB



                                      -50




                                      -60




                                      -70




                                      -80


                                      Center   27.145 MHz                         10 kHz/                          Span   100 kHz




                              Date: 23.MAY.2019       16:09:07




Bureau Veritas Shenzhen Co., Ltd       1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                                                          Tel: +86 755 8600 0151
                                       Zone of Honghualing Industrial Park,Shenzhen,                                   Email: http://www.bureauveritas.com
                                                 Guangdong Province , China
                                                                 Page 14 of 22


       TEST REPORT NUMBER: (8519)114-0047


       6. Power Line Conducted Emission

       6.1. Block diagram of test setup




       6.2. Power Line Conducted Emission Limits (Class B)

                                                       Quasi-Peak Level                  Average Level
                     Frequency
                                                           dB(PV)                           dB(PV)
            150kHz      ~    500kHz                         66 ~ 56*                       56 ~ 46*
            500kHz      ~    5MHz                              56                             46
             5MHz       ~    30MHz                             60                             50

       Note 1: * Decreasing linearly with logarithm of frequency.
       Note 2: The lower limit shall apply at the transition frequencies.



       6.3. Test Procedure
       The EUT and Support equipment, if needed, were put placed on a non-metallic table, 80cm
       above the ground plane.

       Configuration EUT to simulate typical usage as described in clause 2.4 and test equipment as
       described in clause 3 of this report.

       All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
       All support equipment power received from a second LISN.

       Emissions were measured on each current carrying line of the EUT using an EMI Test Receiver
       connected to the LISN powering the EUT.

       The Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
       During the above scans, the emissions were maximized by cable manipulation.



Bureau Veritas Shenzhen Co., Ltd    1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                     Tel: +86 755 8600 0151
                                    Zone of Honghualing Industrial Park,Shenzhen,         Email: http://www.bureauveritas.com
                                              Guangdong Province , China
                                                      Page 15 of 22


       TEST REPORT NUMBER: (8519)114-0047

       The test mode(s) described in clause 2.4 were scanned during the preliminary test.

       After the preliminary scan, we found the test mode producing the highest emission level.

       The EUT configuration and worse cable configuration of the above highest emission levels were
       recorded for reference of the final test.

       EUT and support equipment were set up on the test bench as per the configuration with highest
       emission level in the preliminary test.

       A scan was taken on both power lines, Neutral and Line, recording at least the six highest
       emissions.

       Emission frequency and amplitude were recorded into a computer in which correction factors
       were used to calculate the emission level and compare reading to the applicable limit.

       The test data of the worst-case condition(s) was recorded.

       The bandwidth of test receiver is set at 9 kHz.

       6.4. Test Result
       Not Applicable

       Remark: Conducted limits are not required for devices which do not operate from the AC power
       lines or contain provisions for operation while connected to the AC power lines according to
       15.207(C).


       7. Antenna Requirements
            For intentional device, according to FCC 47 CFR Section 15.203, An intentional radiator
            shall be designed to ensure that no antenna other than that furnished by the responsible
            party shall be used with the device. The use of a permanently attached antenna or of an
            antenna that uses a unique coupling to the intentional radiator shall be considered sufficient
            to comply with the provisions of this section. The manufacturer may design the unit so that a
            broken antenna can be replaced by the user, but the use of a standard antenna jack or
            electrical connector is prohibited.




Bureau Veritas Shenzhen Co., Ltd    1st Floor, Block A,Minlida Industrial Building,4th
                                                                                                    Tel: +86 755 8600 0151
                                    Zone of Honghualing Industrial Park,Shenzhen,        Email: http://www.bureauveritas.com
                                              Guangdong Province , China
                                                      Page 16 of 22



Document Created: 2019-06-10 09:48:01
Document Modified: 2019-06-10 09:48:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC