MPE Revised

FCC ID: 2AENNS1X

RF Exposure Info

Download: PDF
FCCID_3658649

                                                                                               REPORT No.:SZ17090128S02A




                                            RF EXPOSURE
                         EVALUATION REPORT
          APPLICANT                           : Shenzhen Imaginevision Technology Limited

          PRODUCT NAME                        : Z CAM S1x Pro

          MODEL NAME                          : Z CAM S1x Pro

          BRAND NAME                          : Z CAM

          FCC ID                              : 2AENNS1X
          STANDARD(S)                         : 47CFR 2.1091
                                                KDB 447498 D01 General RF Exposure Guidance v06
                                                2017-11-14
          ISSUE DATE                          :



                                                                          Tested by:
                                                                                               Peng Fuwei (Test engineer)



                                                                          Approved by:
                                                                                                  Peng Huarui (Supervisor)




NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn


                                                                                          REPORT No.:SZ17090128S02A


                                                        DIRECTORY
1. Technical Information········································································································ 3
1.1. Applicant and Manufacturer Information····································································· 3
1.2. Equipment Under Test (EUT) Description ··································································· 3
1.3. Photographs of the EUT································································································· 4
1.4. Applied Reference Documents ····················································································· 5
2. DEVICE CATEGORY AND RF EXPOSURE LIMIT··························································· 6
3. MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER ······································· 7
4. RF EXPOSURE EVALUATION ·························································································· 8
Annex A General Information ································································································· 9




                                                              Change History
            Issue                                  Date                                     Reason for change
             1.0                              2017-11-14                                            First edition




MORLAB
                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                             Page2 0f 9


                                                                                     REPORT No.:SZ17090128S02A

1. Technical Information
Note: Provide by manufacturer.


1.1. Applicant and Manufacturer Information

 Applicant:                             Shenzhen Imaginevision Technology Limited
                                        1205,Block A,Cadre headquater center,168                                             tonghua
 Applicant Address:
                                        road,xili,Nanshan Shenzhen, China
 Manufacturer:                          Shenzhen Imaginevision Technology Limited
                                        1205,Block A,Cadre headquater center,168                                             tonghua
 Manufacturer Address:
                                        road,xili,Nanshan Shenzhen, China


1.2. Equipment Under Test (EUT) Description

 EUT Type:                     Z CAM S1x Pro
 Hardware Version:             ver1
 Software Version:             20170912_0.46
 Frequency Bands:              802.11b/g/n-20MHz: 2.412GHz - 2.462GHz
 Modulation Mode:              DSSS, OFDM
 Antenna type:                 Glue rod Antenna




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                        Page3 0f 9


                                                                                     REPORT No.:SZ17090128S02A

1.3. Photographs of the EUT

1.   EUT front view




2.   EUT rear view




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                        Page4 0f 9


                                                                                          REPORT No.:SZ17090128S02A


1.3.1. Identification of all used EUT

The EUT identity consists of numerical and letter characters, the letter character indicates the test
sample, and the following two numerical characters indicate the software version of the test
sample.


              EUT
                                      Hardware Version                                    Software Version
            Identity
                  1#                              ver1                                     20170912_0.46



1.4. Applied Reference Documents

Leading reference documents for testing:
No.    Identity                                       Document Title
1      47 CFR§2.1091                                  Radiofrequency                 Radiation     Exposure         Evaluation:           mobile
                                                      devices
2      KDB 447498 D01v06                              General RF Exposure Guidance




MORLAB
                   SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86-755-36698555   Fax: 86-755-36698525
                   FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                              Page5 0f 9


                                                                                        REPORT No.:SZ17090128S02A


2. DEVICE CATEGORY AND RF EXPOSURE LIMIT
Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with
General Population/Uncontrolled exposure.
Mobile Devices:
47CFR 2.1091(b)
For purposes of this section, a mobile device is defined as a transmitting device designed to be
used in other than fixed locations and to generally be used in such a way that a separation distance
of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s)
and the body of the user or nearby persons. In this context, the term “fixed location” means that the
device is physically secured at one location and is not able to be easily moved to another location.
Transmitting devices designed to be used by consumers or workers that can be easily re-located,
such as wireless devices associated with a personal computer, are considered to be mobile
devices if they meet the 20 centimeter separation requirement.
GENERAL POPULATION / UNCONTROLLED EXPOSURE
The general population/uncontrolled exposure limits are applicable to situations in which the
general public may be exposed or in which persons who are exposed as a consequence of their
employment may not be made fully aware of the potential for exposure or cannot exercise control
over their exposure. Members of the general public would come under this category when
exposure is not employment-related; for example, in the case of a wireless transmitter that
exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as
cellular telephones are not considered sufficient to allow the device to be considered under the
occupational/controlled category, and the general population/uncontrolled exposure limits apply to
these devices.
                     TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

     Frequency                  Electric field                       Magnetic field                Power               Averaging
       range                      strength                             strength                   density                time
       (MHz)                        (V/m)                               (A/m)                    (mW/cm2)              (minutes)

                      (B) Limits for General Population/Uncontrolled Exposure

       0.3-1.34                         614                                   1.63                   *(100)                   30

       1.34-30                         824/f                                 2.19/f                *(180/f2)                  30

       30-300                          27.5                                  0.073                     0.2                    30

      300-1500                            -                                      -                  f/1500                    30

    1500-100,000                          -                                      -                     1.0                    30
    f = frequency in MHz                                          * = Plane-wave equivalent power density




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page6 0f 9


                                                                                      REPORT No.:SZ17090128S02A


3. MEASUREMENT                                              OF                   CONDUCTED                                    PEAK
   OUTPUT POWER
1. Wifi Average output power


                                            Frequency                                Output Power(dBm)
        Band           Channel
                                              (MHz)                    802.11B            802.11G               802.11N 20
                             1                  2412                     13.78               12.01                   10.91
        Wifi                 6                  2437                     14.08               12.63                   11.56
                            11                  2462                     14.35               12.85                   11.81




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                          Page7 0f 9


                                                                                       REPORT No.:SZ17090128S02A


4. RF EXPOSURE EVALUATION
Standalone transmission MPE evaluation


           Frequency            Antenna               Conducted                     Time-averaging             Power                  Limit for
Bands                            Gain               Average Power                        EIRP                  density                  MPE
             (MHz)               (dBi)                  (dBm)                           (mW)                  (mW/cm²)               (mW/cm²)

2.4GHz       2462                    2.0                        14.5                    44.67                  0.0089                        1.0

1. MPE calculation method
                    Power Density = EIRP/4πR²
   Where: EIRP = P·G
          P = Peak out power
          G = Antenna gain
          R = Separation distance (20cm)




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                          Page8 0f 9


                                                                                      REPORT No.:SZ17090128S02A

Annex A General Information
1. Identification of the Responsible Testing Laboratory
  Company Name:                                      Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                                        Morlab Laboratory
  Address:                                           FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                                     Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                                     Province, P. R. China
  Responsible Test Lab Manager:                      Mr. Su Feng
  Telephone:                                         +86 755 36698555
  Facsimile:                                         +86 755 36698525


2. Identification of the Responsible Testing Location
 Name:                                               Shenzhen Morlab Communications Technology Co., Ltd.
                                                     Morlab Laboratory
 Address:                                            FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                                     Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                                     Province, P. R. China




                                                        END OF REPORT




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page9 0f 9



Document Created: 2017-11-29 16:59:28
Document Modified: 2017-11-29 16:59:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC