RF Exposure Information_ MPE report.pdf

FCC ID: 2AENI-15190T

RF Exposure Info

Download: PDF
FCCID_2866004

                       Test Report No.: FS151126N075



                                       RF EXPOSURE REPORT
Applicant                        Southwire Co.

Address                          One Southwire Drive Carrollton, Georgia 30119 USA


Manufacturer or
                                 Shenzhen Everbest Machinery Industry Co., Ltd.
Supplier
                                 19th Building, 5 Region, Baiwangxin Industrial Park, Baimang, Xili, Nanshan, Shenzhen
Address
                                 China 518108

Product                          Bluetooth Multimeter

Brand Name                       Southwire

Model                            15190T

Additional Model &
                                 N/A
Model Difference

Date of tests                    Sep. 18, 2015 ~ Oct. 26, 2015

     FCC Part 2 (Section 2.1091)
     KDB 447498 D01
     IEEE C95.1

CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                    Tested by Blue Zheng                                                             Approved by Chris Chen
             Project Engineer / EMC Department                                                Assistant Manager / EMC Department




                                                                                                            Date: Dec. 25, 2015
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification




                                                        No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
 Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                                        Fax: +86 769 8593 1080
 Dongguan Branch
                                                        Guangdong 523942, China                                     Email: customerservice.dg@cn.bureauveritas.com
                                                                              Page 1 of 6                                                              Report Version 1


                Test Report No.: FS151126N075

                                         Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION.............................................................................................. 4
   2.       RF EXPOSURE DEFINE ................................................................................. 5
   3.       CLASSIFICATION ........................................................................................... 5
   4.       SAR TEST EXCLUSION THRESHOLDS ........................................................ 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 2 of 6                                                    Report Version 1


                Test Report No.: FS151126N075


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED
    FS150918N017             Original release                                                         Oct. 26, 2015
                             Based on the original report FS150918N017 change
                             applicant information, product name, brand name, model
    FS151126N075                                                                                      Dec. 25, 2015
                             name and EUT photo, But it doesn’t need to be retest after
                             engineer evaluated.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FS151126N075

   1. CERTIFICATION


                       FCC ID:      2AENI-15190T
                  PRODUCT:          Bluetooth Multimeter
             BRAND NAME:            Southwire
                MODEL NO.:          15190T
        ADDITIONAL NO.:             N/A
            TEST SAMPLE:            Engineering Sample

                APPLICANT:          Southwire Co.

              STANDARDS:            FCC Part 2 (Section 2.1091)

                                    KDB 447498 D01

                                    IEEE C95.1




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 4 of 6                                                    Report Version 1


                Test Report No.: FS151126N075

   2. RF EXPOSURE DEFINE
   The corresponding SAR Exclusion Threshold condition, listed below:

   1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
     mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
        f(GHz) is the RF channel transmit frequency in GHz
       Power and distance are rounded to the nearest mW and mm before calculation
       The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
   2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold
     is determined according to the following:
     a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at
       100MHz to 1500 MHz
     b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤
       6 GHz
   3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
     a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by
       [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
     b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
       separation distances ≤ 50 mm.
     c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion
       cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any
       test results to be acceptable.


   3. CLASSIFICATION
   The antenna of this product, under normal use condition, is at less than 20cm away
   from the body of the user. So, this device is classified as Portable Device.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 6                                                    Report Version 1


                Test Report No.: FS151126N075

   4. SAR TEST EXCLUSION THRESHOLDS
   According to the KDB 447498:
   The maximun Average output power specified is -15.09dBm = 0.031mW


   The SAR Exclusion Threshold Level:
   = 3.0 * (min. test separation distance, mm) / sqrt(freq. in GHz)
   = 3.0 * 5 / sqrt (2.480) mW
   = 9.53 mW


   Since the source-based time-averaging conducted output power is well below the SAR
   low threshold level, so the EUT is considered to comply with SAR requirement without
   testing.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 6 of 6                                                    Report Version 1



Document Created: 2015-12-29 14:05:37
Document Modified: 2015-12-29 14:05:37

© 2024 FCC.report