Test Report

FCC ID: 2AENH013

Test Report

Download: PDF
FCCID_2779355

                                                    TEST REPORT
 N°: 135376—672302CCR2015—10—07


 Subject                                                 Electromagnetic compatibility (EMC) :
                             Publication CFR 47 Part 15 of 2013 Subpart C — Radio frequency devices — Intentional radiators
                                                                            standards (15.231)




  FCC Registration Number                             166175



  Issued to                                           BodyCap
                                                      6, Rue de la girafe
                                                      14000 Caen
                                                      FRANCE
 Apparatus under test
  4% Product                                          Capsule
  4 Trade mark                                        BodyCap
  4 Manufacturer                                      BodyCap
  4 Model under test                                  Anipill / 01101
   Serial number                                      =


 Test date                                            May 7th, 2015 to May 26th, 2015
 Test location                                        Fontenay Aux Roses
  Test performed by                                   Fostoki MEDJOUDJ & Stéphane PHOUDIAH
  Composition of document                             20 pages


  Document issued on                                  August 3rd, 2015
  Document issued on                                  October 07th, 2015



                               Written by :                                                                Approved by :
        Fostoki MEDJOUDJ & Stéphane PHOUDIAH                                                             Patrick TEIXEIRA
                              Tests operator                                                                                       §       .

                                                                          y Bs           INDUSTRIES E1 '.‘;jmo '                  fi tu4
                                                                         -’%fi            S.A.S au capital de (S 745 984       fi        /
                                                                            "oeP         RCS Nanterre B 408 363 174
                                                                                         33 avenue du Général Leclere
                                                                                         F — 92266 FONTENAY AUX ROSES


  This document shall not be reproduced, except in full, without the written approval of the LCIE. This document contains results related only to the
  item tested. It does not imply the conformity of the whole production to the items tested. Unless otherwise specified, the decision of conformity
  takes into account the uncertainly of measures. This document doesn‘t anticipate any certification decision.


LCIE                               33, av du Général Leclere          Tél : +33 1 40 95 60 60         Société par Actions Simplifiée
Laboratoire Central                BP 8                                Fax : +33 1 40 95 86 56        au capital de 15 745 984 €
des Industries Electriques         92266 Fontenay—aux—Roses cedex     contact@lcie, [r                RCS Nanterre B 408 363 174
                                                                                                                                                      A—01




Une société de Bureau Veritas      France                              wwiw.lcie fr


                                                                                                TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                                               Page 2/20




                                                                  SUMMARY

1.   TEST PROGRAM .............................................................................................................................................. 3
2.   EQUIPMENT DESCRIPTION (DECLARED BY PROVIDER) ........................................................................... 4
3.   FIELD STRENGTH OF FUNDAMENTAL & FIELD STRENGTH OF SPURIOUS EMISSION ......................... 6
4.   EMISSION BANDWIDTH ................................................................................................................................ 12
5.   LIMITING OPERATION ................................................................................................................................... 16
6.   UNCERTAINTIES CHART .............................................................................................................................. 20


                                                                            TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                           Page 3/20




1.       Test Program

References
                       CFR 47 Part 15 Subpart C - Radio frequency devices - Intentional radiators standards
                       (15.231 & 15.205 & 15.207 & 15.209)
                      ANSI C63.10 (2009)
                      CISPR 16-4-2

Emission tests:

           Test Description                   Main characteristics                   Test result - Comments
                                            AC Power Line Conducted
           FCC Part 15.207                                                   PASS    FAIL    NA    NP (Limited Program)
                                                  Emissions

FCC Part 15.231 (a) (1) (2) (3) (4) (5)         Periodic operation           PASS    FAIL    NA    NP (Limited Program)

     FCC Part 15.231 (b) (1) (2) (3)
                                          Field strength of fundamental &
          FCC Part 15.205                                                    PASS    FAIL    NA    NP (Limited Program)
                                                 spurious emission
          FCC Part 15.209
          FCC Part 15.231 (c)                    20dB Bandwidth              PASS    FAIL    NA    NP (Limited Program)

          FCC Part 15.231 (d)                  Frequency tolerance           PASS    FAIL    NA    NP (Limited Program)

 FCC Part 15.231 (b) (1) (2) (3) (e) &    Field strength of fundamental &
         FCC Part 15.205                   spurious emission & Limiting      PASS    FAIL    NA    NP (Limited Program)
         FCC Part 15.209                             operation

The product is Compliant according to CFR 47 Part 15 of 2013 Subpart C - Radio frequency devices - Intentional
radiators standards (15.231)

PASS: EUT complies with standard’s requirement
FAIL: EUT does not comply with standard’s requirement
NA: Not Applicable
NP: Test Not Performed


                                                                     TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                    Page 4/20




2.     Equipment Description (declared by provider)

2.1.   HARDWARE IDENTIFICATION (EUT AND AUXILIARIES):

Equipment under test (EUT): Anipill / 01101                           Serial Number: -




                                              Equipment Under Test


                                                                      TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                     Page 5/20




Inputs/outputs - Cable:
No input output

Auxiliary equipment used during test:
Personal computer

Equipment information: (Declared by provider)

                                  The device is composed of an ingestible capsule, swallowed by the animal, which
                                  uses wireless telemetry to detect and transmit the animal’s core body temperature
                                  to an external monitor (which is also provided).




Apparatus Description
                                             Frequency (MHz)                             Description
                                             Cmin:433.22 MHz
                                                433.42 MHz
                                                433.62 MHz
                                                433.82 MHz
                                                                                     RF Communication
                                            Cnom:434.02 MHz
                                                434.22 MHz
                                                434.42 MHz
                                             Cmax:434.62 MHz

Type of power source:                AC power supply             DC power supply            Battery
Test source voltage:                   Vmin-Vmax:                   120V -60Hz                 3Vdc
                                         Mode 1                             Permanent emission
Operating Modes
                                         Mode 2                        Permanent emission-reception

2.2.    EQUIPMENT LABELLING

                                                 No marking plate

2.3.    EQUIPMENT MODIFICATIONS

 None           Modification:


                                                                         TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                        Page 6/20




3.      Field strength of fundamental & Field strength of spurious emission

3.1.    ENVIRONMENTAL CONDITIONS

Test performed by                 : Fostoki MEDJOUDJ
Date of test                      : 2015/05/07
Ambient temperature               : 20°C
Relative humidity                 : 38%

3.2.    TEST SETUP

Specifications:

Frequency                              30 – 1000 MHz                                           RBW 120 kHz
                                       1-6GHz                                                  RBW 1MHz
Detector                              Peak and Quasi-Peak
Pre characterization in semi anechoic room is performed to define the critical frequencies

Operating conditions:
- The Equipment under Test is installed:
 Measure in semi anechoic room
 Measure in open area site
- Measuring distance:
 3m
 10m
- Deviation method:
 Yes
 No
-Product installation:
 The EUT was tested as a tabletop equipment and was placed on a non-conducting platform the top of which is 0.8m
above the metal ground plane.
 The EUT is at 10cm height from reference plane

Operating mode:
 Mode 1


                                                                 TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                Page 7/20




                                                                                                Absorber

                                                                                                Plastic table

                                                                                                Ground plane
                                                    3m
                                                                                                Turntable

            1 to 4m                                                                             Absorber




                                 Antenna                       EUT

Measuring
                                                                                  80cm
receiver

                                                             turntable

                                           Absorber if
                                           measurements
                                           above 1GHz                    Bundle cable at
                                                                         40cm of the ground
                                                                         plane




                      Test Set up for radiated measurement in semi anechoic chamber




                                  Measurement of radiated disturbances.


                                                                  TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                 Page 8/20




3.3.     LIMIT

        Frequency Bands/frequencies        dB (µV/m) quasi-peak        dB (µV/m) peak   dB (µV/m) average
                30-88MHz                            40                        -                 -
               88 – 216MHz                         43.5                       -                 -
              216 – 960 MHz                         46                        -                 -
             960 – 1000 MHz                        53.9                       -                 -
              1000-6000MHz                           -                      73.9               53.9

3.4.     TEST EQUIPMENT LIST


  Description      Manufacturer             Model                    Identifier    Cal. Date    Cal. Due
Semi anechoic
   chamber           SIEPEL                 C01                     D3044008        2014/09     2015/09
11,8x8,1x9,5m
Bilog antenna        CHASE                CBL6111C                  C2040124        2014/09     2015/09
 Spectrum           ROHDE &
                                           ESIB26                   A2642021        2015/01     2016/01
  analyzer          SCHWARZ
Horn antenna          EMCO                  3115                    C2042018        2015/05     2016/05

 Preamplifier          LCIE                   -                     A7086012        2015/05     2016/05

                   CABLES &                                                         2014/06     2015/06
       Cable                  3.5MD/CSU528AA/3.5MD/4000             A5329374
                 CONNECTIQUES
                   CABLES &            3.5MD/CSU528AA-                              2014/06     2015/06
       Cable                                                        A5329459
                 CONNECTIQUES         TDINOX/3.5MD/7000
       Cable             -                    -                     A5329261        2014/06     2015/06
                    ROHDE &                                                         2015/03     2016/03
 EMI receiver                              ESR 7                    A2642023
                    SCHWARZ


                                                                TEST REPORT N°135376-672302CCr2015-10-07
                                                                                               Page 9/20




3.5.      RESULTS

                                              Cmin
                             Horizontal Polarization (30MHz-6GHz)
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Moyenne/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - QCrête/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Crête/3.0m/
                                                                               Mes.Peak (Horizontale)
                                                                               Mes.Avg (Horizontale)


         80
dBµV/m
         70


         60


         50                                   433.16 M / 48.6


         40


         30


         20


         10


         0
              30MHz   100M                                             1G                                               6GHz
                                             Fréquence (MHz)                                         Polarisation: Horizontale



                                              Cmin
                              Vertical Polarization (30MHz-6GHz)
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Moyenne/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - QCrête/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Crête/3.0m/
                                                                               Mes.Peak (Verticale)
                                                                               Mes.Avg (Verticale)


         80
dBµV/m
         70


         60


         50

                                              433.16 M / 41.5
         40


         30


         20


         10


         0
              30MHz   100M                                             1G                                               6GHz
                                             Fréquence (MHz)                                            Polarisation: Verticale


                                                                TEST REPORT N°135376-672302CCr2015-10-07
                                                                                              Page 10/20




                                             Cmax
                             Horizontal Polarization (30MHz-6GHz)
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Moyenne/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - QCrête/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Crête/3.0m/
                                                                               Mes.Peak (Horizontale)
                                                                               Mes.Avg (Horizontale)


         80
dBµV/m
         70


         60


         50


                                              434.66 M / 40.3
         40


         30


         20


         10


         0
              30MHz   100M                                             1G                                               6GHz
                                             Fréquence (MHz)                                         Polarisation: Horizontale



                                              Cmax
                              Vertical Polarization (30MHz-6GHz)
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Moyenne/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - QCrête/3.0m/
                                                                               FCC/FCC 15.209 >30M - Classe:1 - Crête/3.0m/
                                                                               Mes.Peak (Verticale)
                                                                               Mes.Avg (Verticale)


         80
dBµV/m
         70


         60


         50                                    434.6 M / 48.1


         40


         30


         20


         10


         0
              30MHz   100M                                             1G                                               6GHz
                                             Fréquence (MHz)                                            Polarisation: Verticale


                                                                    TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                  Page 11/20




                            Frequency              Peak Level            QPeak Level               Limit
       Polarisation
                              (MHz)                 (dBµV/m)              (dBµV/m)               (dBµV/m)
        Vertical               66.4                   25.3                    -                     40
        Vertical              100.9                   29.8                    -                    43.5
        Vertical              251.1                    28                     -                     46
       Horizontal             280.6                   24.1                    -                     46
       Horizontal             859.7                   30.5                    -                     46
       Horizontal             995.7                   33.2                    -                    53.9


                            Frequency              Peak Level           Average Level         Average Limit
        Channel
                              (MHz)                 (dBµV/m)              (dBµV/m)              (dBµV/m)
         Cmin                 433.22                  48.6                    -                   72.8
         Cmax                 434.62                  48.1                    -                   72.8

3.6.     CONCLUSION.

Measures of Field strength of fundamental & spurious domain, performed on the sample of the product Anipill /
01101, SN: -, in configuration and description presented in this test report, show levels conform to the FCC part
15.231e limits.


                                                                TEST REPORT N°135376-672302CCr2015-10-07
                                                                                              Page 12/20




4.      EMISSION BANDWIDTH

4.1.    TEST CONDITIONS

Test performed by       : Stéphane PHOUDIAH
Date of test            : 2015/05/06
Ambient temperature     : 22°C
Relative humidity       : 42%

4.2.    TEST SETUP

- The Equipment under Test is installed:
   In the climatic chamber
   On a table
   In an anechoic chamber

-Measurement is performed with a spectrum analyzer
  On the EUT conducted access
  With a test fixture

The spectrum analyzer is used to find the emission bandwidth.
Detector peak

Operating mode:
 Mode 1




Photograph for Emission Bandwidth


                                                                     TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                   Page 13/20




4.3.      LIMIT

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70
MHz and below 900 MHz. For devices operating above 900 MHz, the emission shall be no wider than 0.5% of the
center frequency. Bandwidth is determined at the points 20 dB down from the modulated carrier.

4.4.      TEST EQUIPMENT LIST

   DESCRIPTION            MANUFACTURER              MODEL         N° LCIE       Cal_Date           Cal_Due
     Multi-meter            KEITHLEY                 2000        A1241084        2015/02            2016/02
  Spectrum analyzer      ROHDE & SCHWARZ             FSL6        A4060032        2015/04            2017/04
                                                                               Verified with      Verified with
   DC power supply       ROHDE & SCHWARZ          NGSM32/10      A7040074       calibrated         calibrated
                                                                                Multimeter         Multimeter
                           Télédyne & MINI       920-0202-024
RF cable & Attenuator                                         A5329675           2014/10            2015/10
                              CIRCUITS             & FW-20+

4.5.      DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

   None                   Divergence:


                                                                        TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                      Page 14/20




4.6.   GRAPHICS & RESULTS

                                                            Tnom
                                                            Vnom
                                                            Cmin

                                             * RBW 10 kHz
                         * Att 15 dB         * VBW 30 kHz   M1[1]               - 28. 67 dBm
                           Ref 5.00 dBm        SWT 10ms                 433. 154300000 MHz
                                                            ndB                    20. 00 dB
                             0 dBm
                      1Pk                                   Bw          155. 700000000 kHz
                      View                                  Q fac tor                 2782. 2
                             -10 dBm
                                                            T1[1]               - 49. 35 dBm
                                                                        433. 122200000 MHz
                             -20 dBm                        T2[1]               - 48. 05 dBm
                                                      M1                433. 277900000 MHz
                             -30 dBm


                             -40 dBm
                                                     T1     T2
                             -50 dBm


                             -60 dBm


                             -70 dBm


                             -80 dBm


                             -90 dBm

                             CF 433.22 MHz                                  Span 1.0 MHz

                      Date: 6.MAY.2015    14:45:18


                                                            Cmax

                                             * RBW 10 kHz
                         * Att 15 dB         * VBW 30 kHz   M1[1]               - 28. 47 dBm
                           Ref 5.00 dBm        SWT 10ms                 434. 554100000 MHz
                                                            ndB                    20. 00 dB
                             0 dBm
                      1Pk                                   Bw          155. 700000000 kHz
                      View                                  Q fac tor                 2791. 2
                             -10 dBm
                                                            T1[1]               - 49. 32 dBm
                                                                        434. 522200000 MHz
                             -20 dBm                        T2[1]               - 47. 72 dBm
                                                      M1                434. 677900000 MHz
                             -30 dBm


                             -40 dBm
                                                     T1     T2
                             -50 dBm


                             -60 dBm


                             -70 dBm


                             -80 dBm


                             -90 dBm

                             CF 434.62 MHz                                  Span 1.0 MHz

                      Date: 6.MAY.2015    16:51:23


                                                                     TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                   Page 15/20




                         Temperature                                          Tnom
                            Voltage                                           Vnom
                     Channel                                 Cmin                           Cmax
             Emission bandwidth (kHz)                        155,7                          155,7
                   Limit (kHz)                              1083,05                        1086,55

4.7.   CONCLUSION

Emission bandwidth measurement performed on the sample of the product Anipill / 01101, SN: -, in configuration
and description presented in this test report, show levels conform to the FCC part 15.231d limits.


                                                                          TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                        Page 16/20




5.      LIMITING OPERATION

5.1.    TEST CONDITIONS

Test performed by       : Stéphane PHOUDIAH
Date of test            : 2015/07/07
Ambient temperature     : 24°C
Relative humidity       : 47%

5.2.    TEST SETUP

- The Equipment under Test is installed:
   In the climatic chamber
   On a table
   In an anechoic chamber

-Measurement is performed with a spectrum analyzer
  On the EUT conducted access
  With a test fixture

The spectrum analyzer is used in span 0 to find the limiting operation.
Detector peak

Operating mode:
 Mode 2




Photograph for Limited Operation


                                                                  TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                Page 17/20




5.3.      LIMIT

Devices shall be provided with a means for automatically limiting operation so that the duration of each
transmission shall not be greater than one second and the silent period between transmissions shall be at
least 30 times the duration of the transmission but in no case less than 10 seconds.

5.4.      TEST EQUIPMENT LIST

       DESCRIPTION        MANUFACTURER            MODEL         N° LCIE       Cal_Date           Cal_Due
        EMI receiver      ROHDE & SCHWARZ           ESR 7       A2642023       2015/03            2016/03

5.5.      DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

   None                  Divergence:


                                             TEST REPORT N°135376-672302CCr2015-10-07
                                                                           Page 18/20




5.6.   GRAPHICS & RESULTS

                                 Tnom
                                 Vnom
                                 Cnom
                            Transmitting time




                               Silent time


                                                                     TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                   Page 19/20




                        Temperature                                                 Tnom
                          Voltage                                                   Vnom
                          Channel                                                   Cnom
                    Transmitting time (s)                                          0,00355
                       Silent time (s)                                              30,13

5.7.   CONCLUSION

Limiting operation measurement performed on the sample of the product Anipill / 01101, SN: -, in configuration and
description presented in this test report, show levels conform to the FCC part 15.231e limits.


                                                                                          TEST REPORT N°135376-672302CCr2015-10-07
                                                                                                                        Page 20/20




 6.        Uncertainties Chart

                                                                                                         Wide uncertainty
                                                                                                                                CISPR uncertainty
                                       Kind of measurement                                                  laboratory
                                                                                                                                   limit y(dB)
                                                                                                          (k=2) x(dB)
Measurement of conducted disturbances in voltage on the AC power port on the Fontenay-aux-
                                                                                                      3.51                  3.6
Roses site.
Measurement of discontinuous conducted disturbances in voltage on the AC power port on the
                                                                                                      3.45                  3.6
Fontenay-aux-Roses site. (S48 room)
Measurement of conducted disturbances in voltage on the AC power port on the Ecuelles site.
                                                                                                               3.86                    3.6
In Situ measurement of conducted disturbances in voltage on the AC power port with ESH2
                                                                                                               3.51                    3.6
receiver
Measurement of conducted disturbances in voltage on the DC power port on the Fontenay-aux-
                                                                                                               3.49                    3.6
Roses site.
Measurement of conducted disturbances in voltage on the DC power port on the Ecuelles site.
                                                                                                               3.72                    3.6
Measurement of conducted disturbances in voltage on the telecommunication port.                                                      Under
                                                                                                               3.26
                                                                                                                                  consideration
Measurement of conducted disturbances in voltage on the telecommunication port at Ecuelles Site.                                     Under
                                                                                                               3.45
                                                                                                                                  consideration
Measurement of conducted disturbances in current                                                                                     Under
                                                                                                               3.09
                                                                                                                                  consideration
Measurement of radiated electric field from 30 to 200MHz on the Fontenay-aux-Roses site (with
                                                                                                               5.2                     5.2
EATON 96002 antenna)
Measurement of radiated electric field from 200 to 1000MHz on the Fontenay-aux-Roses site                      5.3                     5.2
Measurement of radiated electric field from 1 to 18GHz on the Fontenay-aux-Roses site                                                Under
                                                                                                               4.8
                                                                                                                                  consideration
Measurement of radiated electric field from 30 to 80MHz in horizontal position on the Ecuelles site
                                                                                                               3.77                    5.2
(dipole antenna)
Measurement of radiated electric field from 30 to 80MHz in vertical position on the Ecuelles site
                                                                                                               4.12                    5.2
(dipole antenna)
Measurement of radiated electric field from 80 to 1000MHz in horizontal position on the Ecuelles
                                                                                                               4.19                    5.2
site (R&S HL023 A2 logper antenna)
Measurement of radiated electric field from 80 to 1000MHz in vertical position on the Ecuelles site
                                                                                                               4.50                    5.2
(R&S HL023 A2 logper antenna)
Measurement of radiated electric field from 30 to 1000MHz in horizontal position on the Ecuelles
                                                                                                               4.24                    5.2
site (CBL6112 bilog antenna)
Measurement of radiated electric field from 30 to 1000MHz in vertical position on the Ecuelles site
                                                                                                               4.55                    5.2
(CBL6112 bilog antenna)
Measurement of radiated electric field from 1 to 18GHz on the Ecuelles site                                                          Under
                                                                                                               5.16
                                                                                                                                  consideration
Measurement of current harmonics                                                                      11.11%                /
Flicker measurement                                                                                   9.26%                 /
Measurement of disturbance power                                                                      3.32                  4.5
Immunity to conducted disturbances, induced by radio-frequency fields                                 2.36                  /
Immunity to conducted disturbances, induced by radio-frequency fields with injection clamp
                                                                                                      2.76                  /
Immunity to radiated electromagnetic field                                                            2.64                  /
EMF measurement according to EN62233 from 10KHz to 400KHz                                             23,51%                /
 Unless otherwise specified, the decision of conformity takes into account the uncertainly of measures.
                                                   End of test report



Document Created: 2015-10-07 11:44:04
Document Modified: 2015-10-07 11:44:04

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC