RF Partial test report-P22

FCC ID: 2AEMI-BRN402

Test Report

Download: PDF

                               Test Report No.: RF181008W004-1



                                                                 FCC TEST REPORT
                                                                                       (PART 22)
       Applicant:                            Particle Industries,Inc


       Address:                              126 Post St, 4th floor, San Francisco, CA 94108 USA


       Manufacturer or
                                             Particle Industries,Inc
       Supplier:

       Address:                              126 Post St, 4th floor, San Francisco, CA 94108 USA


       Product:                              Boron LTE

       Brand Name:                           Particle Industries, Inc

       Model Name:                           BRN402

       FCC ID:                               2AEMI-BRN402

       Date of tests:                        Oct. 09, 2018 ~ Nov. 08, 2018

       The tests have been carried out according to the requirements of the following standard:
             FCC PART 22, Subpart H
             ANSI/TIA/EIA-603-D
             ANSI/TIA/EIA-603-E
       CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                                 Prepared by Roger Li                                                                                     Approved by Sam Tung
                             Engineer / Mobile Department                                                                               Manager / Mobile Department




                                       Date: Nov. 09, 2018                                                                                       Date: Nov. 09, 2018
       This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
       http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or
       entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth
       in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted.
       Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited
       tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that
       such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the
       completeness of this report, the tests conducted and the correctness of the report contents.




                                                             No.B102, Dazu Chuangxin Mansion, North of Beihuan                                           Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                             Avenue, North Area, Hi-Tech Industrial Park, Nanshan                                        Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                                             District, Shenzhen, Guangdong, China                                                        Email: customerservice.dg@cn.bureauveritas.com
                                                                                             Page 1 of 34


                            Test Report No.: RF181008W004-1


                                                        TABLE OF CONTENTS
         RELEASE CONTROL RECORD ............................................................................................................... 4

         1 SUMMARY OF TEST RESULTS ............................................................................................................. 5

            1.1      MEASUREMENT UNCERTAINTY ............................................................................................... 5
            1.2      TEST SITE AND INSTRUMENTS ................................................................................................ 6
         2 GENERAL INFORMATION ..................................................................................................................... 7

            2.1      GENERAL DESCRIPTION OF EUT ............................................................................................. 7
            2.2      CONFIGURATION OF SYSTEM UNDER TEST .......................................................................... 8
            2.3      DESCRIPTION OF SUPPORT UNITS ......................................................................................... 9
            2.4      TEST ITEM AND TEST CONFIGURATION.................................................................................. 9
            2.5      EUT OPERATING CONDITIONS ............................................................................................... 11
            2.6      GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 11
         3 TEST TYPES AND RESULTS ............................................................................................................... 12

            3.1    OUTPUT POWER MEASUREMENT ......................................................................................... 12
              3.1.1   LIMITS OF OUTPUT POWER MEASUREMENT ............................................................... 12
              3.1.2   TEST PROCEDURES ........................................................................................................ 12
              3.1.3   TEST SETUP ...................................................................................................................... 13
              3.1.4   TEST RESULTS ................................................................................................................. 14
            3.2    FREQUENCY STABILITY MEASUREMENT ............................................................................. 15
              3.2.1   LIMITS OF FREQUENCY STABILIITY MEASUREMENT .................................................. 15
              3.2.2   TEST PROCEDURE ........................................................................................................... 15
              3.2.3   TEST SETUP ...................................................................................................................... 15
              3.2.4   TEST RESULTS ................................................................................................................. 15
            3.3    OCCUPIED BANDWIDTH MEASUREMENT ............................................................................ 16
              3.3.1   TEST PROCEDURES ........................................................................................................ 16
              3.3.2   TEST SETUP ...................................................................................................................... 16
              3.3.3   TEST RESULTS ................................................................................................................. 16
            3.4    BAND EDGE MEASUREMENT ................................................................................................. 17
              3.4.1   LIMITS OF BAND EDGE MEASUREMENT ....................................................................... 17
              3.4.2   TEST SETUP ...................................................................................................................... 17
              3.4.3   TEST PROCEDURES ........................................................................................................ 18
              3.4.4   TEST RESULTS ................................................................................................................. 18
            3.5    CONDUCTED SPURIOUS EMISSIONS.................................................................................... 19
              3.5.1   LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT ............................ 19
              3.5.2   TEST PROCEDURE ........................................................................................................... 19
              3.5.3   TEST SETUP ...................................................................................................................... 19
              3.5.4   TEST RESULTS ................................................................................................................. 19
            3.6    RADIATED EMISSION MEASUREMENT .................................................................................. 20
              3.6.1   LIMITS OF RADIATED EMISSION MEASUREMENT ....................................................... 20
              3.6.2   TEST PROCEDURES ........................................................................................................ 20
              3.6.3   DEVIATION FROM TEST STANDARD .............................................................................. 20
              3.6.4   TEST SETUP ...................................................................................................................... 21
                                              No.B102, Dazu Chuangxin Mansion, North of Beihuan                 Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                              Avenue, North Area, Hi-Tech Industrial Park, Nanshan              Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                              District, Shenzhen, Guangdong, China                              Email: customerservice.dg@cn.bureauveritas.com
                                                                     Page 2 of 34


                             Test Report No.: RF181008W004-1
               3.6.5         TEST RESULTS ................................................................................................................. 23
            3.7    PEAK TO AVERAGE RATIO ...................................................................................................... 31
              3.7.1   LIMITS OF PEAK TO AVERAGE RATIO MEASUREMENT ............................................... 31
              3.7.2   TEST SETUP ...................................................................................................................... 31
              3.7.3   TEST PROCEDURES ........................................................................................................ 31
              3.7.4   TEST RESULTS ................................................................................................................. 31
         4 PHOTOGRAPHS OF THE TEST CONFIGURATION ........................................................................... 32

         5 INFORMATION ON THE TESTING LABORATORIES ......................................................................... 33

         6 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY
         THE LAB .................................................................................................................................................. 34




                                                 No.B102, Dazu Chuangxin Mansion, North of Beihuan                      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                 Avenue, North Area, Hi-Tech Industrial Park, Nanshan                   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                                 District, Shenzhen, Guangdong, China                                   Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 3 of 34


                        Test Report No.: RF181008W004-1

                                          RELEASE CONTROL RECORD

            ISSUE NO.              REASON FOR CHANGE                                                          DATE ISSUED
            RF181008W004-1         Original release                                                           Nov. 09, 2018




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 4 of 34


                        Test Report No.: RF181008W004-1



         1 SUMMARY OF TEST RESULTS
         The EUT has been tested according to the following specifications:

                                       APPLIED STANDARD: FCC Part 22 & Part 2

          STANDARD
                                 TEST TYPE                               RESULT                      REMARK
           SECTION
            2.1046
                      Effective Radiated Power                             PASS      Meet the requirement of limit.
           22.913 (a)
            2.1055                                                       N/A(see
                      Frequency Stability                                        Meet the requirement of limit.
            22.355                                                        note)
             2.1049                                                      N/A(see
                           Occupied Bandwidth                                    Meet the requirement of limit.
             22.917b                                                      note)
                                                                         N/A(see
                 --        Peak to average ratio*                                Meet the requirement of limit.
                                                                          note)
                                                                         N/A(see
             22.917        Band Edge Measurements                                Meet the requirement of limit.
                                                                          note)
             2.1051                                                      N/A(see
                           Conducted Spurious Emissions                          Meet the requirement of limit.
             22.917                                                       note)
                                                                                     Meet the requirement of limit.
             2.1053
                           Radiated Spurious Emissions                     PASS      Minimum passing margin is
             22.917
                                                                                     -21.34dB at 58.160MHz.
         Note: The product Particle BRN402 is fully integrated the LTE Cat-M1 Module SARA-R410M (FCC ID:
         XPY2AGQN4NNN), no other modification on the LTE Cat-M1 Module radio parameter such as power,
         frequency range, modulation etc., for this report only test Effective Radiated Power and Radiated Spurious
         Emissions, other test data please refer the module report. The Module report number has been noted in this
         report, Please refer to this report for details.

         * Refer to KDB 971168 D01 Power Meas License Digital Systems v03r01.


         1.1 MEASUREMENT UNCERTAINTY

         Where relevant, the following measurement uncertainty levels have been estimated for
         tests performed on the EUT as specified in CISPR 16-4-2:
                       MEASUREMENT                                FREQUENCY                          UNCERTAINTY
                      Conducted emissions                          9kHz~30MHz                              2.66dB
                                                                 9KHz ~ 30MHz                              2.68dB
                                                                 30MHz ~ 1GHz                              3.26dB
                       Radiated emissions
                                                                  1GHz ~ 18GHz                             4.48dB
                                                                 18GHz ~ 40GHz                             4.12dB

         This uncertainty represents an expanded uncertainty expressed at approximately the 95%
         confidence level using a coverage factor of k=2.
                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 5 of 34


                        Test Report No.: RF181008W004-1



         1.2 TEST SITE AND INSTRUMENTS
       Equipment               Manufacturer          Model No.           Serial No.           Last Cal.        Next Cal.
       MXE EMI Receiver        KEYSIGHT              N9038A-544          MY54450026           Mar. 16,18       Mar. 15,19
       EXA Signal Analyzer     KEYSIGHT              N9010A-526          MY54510322           Mar. 16,18       Mar. 15,19
       Bilog Antenna 1         ETS-LINDGREN          3143B               00161964             Nov. 26,16       Nov. 25,18
       Bilog Antenna 2         ETS-LINDGREN          3143B               00161965             Nov. 26,16       Nov. 25,18
       Horn Antenna 1          ETS-LINDGREN          3117                00168728             Nov. 26,16       Nov. 25,18
       Horn Antenna 2          ETS-LINDGREN          3117                00168692             Nov. 26,16       Nov. 25,18
       Loop antenna            Daze                  ZN30900A            0708                 Nov. 20,17       Nov. 19,18
                                                     QWH-SL-18-40
       Horn Antenna
                               N/A                   -K-SG/QMS-00        15433                Dec. 16,16 Dec. 15,18
       (18GHz-40GHz)
                                                     361
       Radio
       Communication           ANRITSU               MT8820C             6201465426           Mar. 02,18 Mar. 01,19
       Analyzer
       Signal Pre-Amplifier    EMSI     EMC 9135      980249                                  Jul. 09,18       Jul. 08,19
       Signal Pre-Amplifier    EMSI     EMC 012645B 980257                                    Jul. 09,18       Jul. 08,19
       Signal Pre-Amplifier    EMSI     EMC 184045B 980259                                    Jul. 09,18       Jul. 08,19
       3m Semi-anechoic                               Euroshieldpn-
                           ETS-LINDGREN 9m*6m*6m                                              Apr. 21,18       Apr. 20,19
       Chamber                                        CT0001143-1216
       Test Software       E3           V 9.160323    N/A                                     N/A              N/A
                                        ADT_Radiated
       Test Software       ADT                        N/A                                     N/A              N/A
                                        _V7.6.15.9.2
                                        50HF-010-SM
       10dB Attenuator     JFW/USA                    1505                                    Jul. 09,18       Jul. 08,19
                                        A
       Power Meter         Anritsu      ML2495A       1506002                                 Mar. 02,18 Mar. 01,19
       Power Sensor        Anritsu      MA2411B       1339352                                 Mar. 16,18 Mar. 15,19
       Humid & Temp                     ITH-120-45-CP
                           Juyi                       IAA1504-001                             Jul. 09,18       Jul. 08,19
       Programmable Tester              -AR
       MXG Analog
       Microvave           KEYSIGHT     N5183A        MY50143024                              Mar. 13,18 Mar. 12,19
       Signal Generator
           NOTE: 1. The calibration interval of the above test instruments is 12 months or 24 months and the
                    calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                 2. The test was performed in 3m Semi-anechoic Chamber and RF Oven Room.
                   3. The horn antenna is used only for the measurement of emission frequency above 1GHz if
                       tested.
                   4. The FCC Site Registration No. is 525120; The Designation No. is CN1171.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 6 of 34


                        Test Report No.: RF181008W004-1


         2 GENERAL INFORMATION
         2.1 GENERAL DESCRIPTION OF EUT
         EUT                              Boron LTE
         MODEL NAME                       BRN402
                                          5.0Vdc (adapter)
         POWER SUPPLY
                                          3.7Vdc (battery)
         MODULATION TYPE                  LTE                                                 QPSK, 16QAM
                                          LTE Band 5
         FREQUENCY RANGE                                                                      824.7MHz ~ 848.3MHz
                                          (Channel Bandwidth: 1.4MHz)
                                          LTE Band 5
         MAX. ERP POWER                                                                       96mW
                                          (Channel Bandwidth: 1.4MHz)
         EMISSION                                                                             QPSK: 1M11G7D
                                          LTE Band 5
         DESIGNATOR                                                                           16QAM: 1M11W7D
         ANTENNA TYPE                     Fixed External antenna with 1dBi gain
         HW VERSION                       V1.00
         SW VERSION                       V0.8.0
         I/O PORTS                        Refer to user’s manual
         DATA CABLE                       N/A
         NOTE:
         1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's
            manual.
         2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
            test report.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 7 of 34


                        Test Report No.: RF181008W004-1


         2.2 CONFIGURATION OF SYSTEM UNDER TEST
         FOR RADIATION EMISSION




                                                           EUT     (Powered from AC Adapter)


              Test table



                                                     Universal Radio
                                                     Communication
                                                         Tester


             *Kept in a remote area



         FOR CONDUCTED & E.R.P. TEST




                                                           EUT     (Powered from battery)



              Test table



                                                     Universal Radio
                                                     Communication
                                                         Tester



             *Kept in a remote area




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 8 of 34


                         Test Report No.: RF181008W004-1


         2.3 DESCRIPTION OF SUPPORT UNITS

         The EUT has been tested as an independent unit together with other necessary
         accessories or support units. The following support units or accessories were used to
         form a representative test configuration during the tests.

                NO.     PRODUCT            BRAND          MODEL NO.                      SERIAL NO.                    FCC ID
                   1    DC source        LONG WEI           PS-6403D                     010934269                       N/A
                   2           PC             HP            A6608CN                     3CR83825X3                       N/A
                   3          USB             N/A               N/A                           N/A                        N/A
                   4         Battery          N/A               N/A                           N/A                        N/A
                   5         Adapter          N/A               N/A                           N/A                        N/A


                NO.                 SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
                   1   DC Line: Unshielded, Detachable 1.0m
                   2   AC Line: Unshielded, Detachable 1.5m
                   3   N/A
                   4   N/A
                  5 N/A
            NOTE:
            1. All power cords of the above support units are non shielded (1.8m).


         2.4 TEST ITEM AND TEST CONFIGURATION

         Pre-Scan has been conducted to determine the worst-case mode from all possible
         combinations between available modulations, data rates, XYZ axis and antenna ports
         The worst case in ERP and radiated emission was found when positioned on X-plane for
         LTE. Following channel(s) was (were) selected for the final test as listed below:

             EUT
          CONFIGURE                                     DESCRIPTION
            MODE

               A         EUT + Adapter + USB Cable with LTE link

               B         EUT + Battery with LTE link




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 9 of 34


                        Test Report No.: RF181008W004-1


         LTE BAND 5 MODE
                                Available                               Channel
            TEST ITEM                            Tested Channel                           modulation                     mode
                                Channel                                bandwidth


               ERP            20407 to 20643   20407, 20525, 20643         1.4MHz        QPSK,16QAM               1 RB / 0 RB Offset

            RADIATED
                              20407 to 20643   20407, 20525, 20643         1.4MHz              QPSK              1 RB / 0 RB Offset
            EMISSION




                     TEST ITEM                 ENVIRONMENTAL CONDITIONS               INPUT POWER                    TESTED BY
                        ERP                          23deg. C, 62%RH                3.7Vdc from Battery                 Star Le
               RADIATED EMISSION                     25deg. C, 63.6%RH               5Vdc from adapter                  Star Le




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan        Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan     Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                        District, Shenzhen, Guangdong, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 10 of 34


                        Test Report No.: RF181008W004-1



         2.5 EUT OPERATING CONDITIONS

         The EUT makes a call to the communication simulator. The communication simulator
         station system controlled a EUT to export maximum output power under transmission
         mode and specific channel frequency



         2.6 GENERAL DESCRIPTION OF APPLIED STANDARDS

         The EUT is a RF product. According to the specifications of the manufacturer, it must
         comply with the requirements of the following standards:

         FCC 47 CFR Part 2
         FCC 47 CFR Part 22
         KDB 971168 D01 Power Meas License Digital Systems v03r01
         ANSI/TIA/EIA-603-D
         ANSI/TIA/EIA-603-E
         ANSI C63.26-2015

         NOTE: All test items have been performed and recorded as per the above standards.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 11 of 34


                        Test Report No.: RF181008W004-1



         3 TEST TYPES AND RESULTS
         3.1 OUTPUT POWER MEASUREMENT

         3.1.1 LIMITS OF OUTPUT POWER MEASUREMENT

         Mobile / Portable station are limited to 7 watts e.r.p.

         3.1.2 TEST PROCEDURES

         EIRP / ERP MEASUREMENT:

          a. All measurements were done at low, middle and high operational frequency range.
             RBW and VBW is 10MHz for LTE mode.

          b. Substitution method is used for E.I.R.P measurement. In the semi-anechoic chamber,
             EUT placed on the 0.8m height of Turn Table, rotated the table around 360 degrees to
             search the maximum radiation power and receiver antenna shall be rotated vertical
             and horizontal polarization and moved height from 1m to 4m to find the maximum
             polar radiated power. The “Read Value” is the spectrum reading the maximum
             power value.

          c. The substitution horn antenna is substituted for EUT at the same position and signals
             generator export the CW signal to the substitution antenna via a tx cable. Rotated the
             Turn Table and moved receiving antenna to find the maximum radiation power. Adjust
             output power level of S.G to get a Value of spectrum reading equal to “Read Value
             “ of step b. Record the power level of S.G

          d. EIRP = Output power level of S.G – TX cable loss + Antenna gain of substitution horn.
             E.R.P power can be calculated form E.I.R.P power by subtracting the gain of dipole,
             E.R.P power = E.I.P.R power - 2.15dBi.

         CONDUCTED POWER MEASUREMENT:

             The EUT was set up for the maximum power with WCDMA link data modulation and link
             up with simulator. Set the EUT to transmit under low, middle and high channel and
             record the power level shown on simulator.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 12 of 34


                        Test Report No.: RF181008W004-1


         3.1.3 TEST SETUP

         EIRP / ERP Measurement:
         <Radiated Emission below or equal 1 GHz>
                                                                            Ant. Tower
                                                                                                       1-4m
                                                           3m
                                EUT

                                                    Turn Table

                          0.8m


                                                          Ground Plane

                                                         Spectrum




           <Radiated Emission above 1 GHz>


                                                                           Ant. Tower                1-4m
                                                                                                     Variable
                     EUT&                                   3m
                     Support Units
                                                Turn Table
                                                                  Absorber
                        150cm


                                                         Ground Plane
                                                         Test
                                                         Receiver



         For the actual test configuration, please refer to the attached file (Test Setup Photo).

         CONDUCTED POWER MEASUREMENT:


                           COMMUNICATION
                                                                                    EUT
                             SIMULATOR




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 13 of 34


                        Test Report No.: RF181008W004-1


         3.1.4 TEST RESULTS

         CONDUCTED OUTPUT POWER (dBm)
         The test results please refer the module Report No.:SD72128174-0517B.

         ERP POWER (dBm)

         LTE BAND 5
         CHANNEL BANDWIDTH: 1.4MHz QPSK
                       Frequency       SPA LVL       Correction                  Polarization                         LIMIT
          Channel                                               ERP(dBm) ERP(mW)
                         (MHz)          (dBm)        Factor(dB)                     (H/V)                              (W)

            20407         824.7         -11.72          33.67             19.80       95.57             H                7
            20525         836.5         -12.82          33.62             18.65       73.35             H                7
            20643         848.3         -13.23          33.65             18.27       67.07             H                7
            20407         824.7         -23.83          34.25             8.27         6.71             V                7
            20525         836.5         -25.12          34.60             7.33         5.41             V                7
            20643         848.3         -24.20          34.63             8.28         6.73             V                7




         CHANNEL BANDWIDTH: 1.4MHz 16QAM
                       Frequency       SPA LVL       Correction                  Polarization                         LIMIT
          Channel                                               ERP(dBm) ERP(mW)
                         (MHz)          (dBm)        Factor(dB)                     (H/V)                              (W)

            20407         824.7         -12.55          33.67             18.97       78.94             H                7
            20525         836.5         -13.84          33.62             17.63       58.00             H                7
            20643         848.3         -14.33          33.65             17.17       52.06             H                7
            20407         824.7         -24.66          34.25             7.44         5.54             V                7
            20525         836.5         -26.14          34.60             6.31         4.27             V                7
            20643         848.3         -25.30          34.63             7.18         5.22             V                7

         REMARKS: 1. ERP Output Power (dBm) = SPA LVL (dBm) + Correction Factor (dB) -2.15(dB).
                : 2. Correction factor (dB) = Free Space Loss + Antenna Factor + Cable Loss




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 14 of 34


                        Test Report No.: RF181008W004-1


         3.2 FREQUENCY STABILITY MEASUREMENT

         3.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT

         1.5 ppm is for base and fixed station. 2.5 ppm is for mobile station.

         3.2.2 TEST PROCEDURE
          a. Device is placed at the oven room. The oven room could control the temperatures and
             humidity. Power warm up is at least 15 min and power applied should perform before
             recording frequency error.
          b. EUT is connected the external power supply to control the DC input power. The test
             voltage range is from minimum to maximum working voltage. Each step shall be
             record the frequency error rate.
          c. The temperature range step is 10 degrees in this test items. All temperature levels
             shall be hold the ±0.5℃ during the measurement testing. The each temperature step
             shall be at least 0.5 hours, consider the EUT could be test under the stability
             condition.

         NOTE: The frequency error was recorded frequency error from the communication simulator.


         3.2.3 TEST SETUP


                                                                                      OVEN ROOM
                   COMMUNICATION
                     SIMULATOR
                                                                                       ANTENNA




                                                                           EXTERNAL POWER SOURCE

                                                                          EUT
                  DC POWER SUPPLY




         3.2.4 TEST RESULTS

         The test results please refer the module Report No.:SD72128174-0517B.



                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 15 of 34


                        Test Report No.: RF181008W004-1



         3.3 OCCUPIED BANDWIDTH MEASUREMENT

         3.3.1 TEST PROCEDURES

         The EUT makes a call to the communication simulator. All measurements were done at
         low, middle and high operational frequency range. The communication simulator station
         system controlled a EUT to export maximum output power under transmission mode and
         specific channel frequency. Use OBW measurement function of Spectrum analyzer to
         measure 99 % occupied bandwidth.


         3.3.2 TEST SETUP


             COMMUNICATION
               SIMULATOR                            POWER SPLITTER                                         SPECTRUM
                                                                                                           ANALYZER


                                                                                              10dB ATTENUATION
                                                                                              PAD
                                                             EUT




         3.3.3 TEST RESULTS

         The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan        Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan     Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 16 of 34


                        Test Report No.: RF181008W004-1



         3.4     BAND EDGE MEASUREMENT

         3.4.1 LIMITS OF BAND EDGE MEASUREMENT

         Power of any emission outside of the authorized operating frequency ranges must be
         attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. In the
         1 MHz bands immediately outside and adjacent to the frequency block a resolution
         bandwidth of at least one percent of the emission bandwidth of the fundamental emission
         of the transmitter may be employed.


         3.4.2 TEST SETUP



             COMMUNICATION
               SIMULATOR                            POWER SPLITTER                                         SPECTRUM
                                                                                                           ANALYZER


                                                                                              10dB ATTENUATION
                                                                                              PAD
                                                             EUT




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan        Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan     Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 17 of 34


                        Test Report No.: RF181008W004-1


         3.4.3 TEST PROCEDURES

        a. All measurements were done at low and high operational frequency range.

        b. The center frequency of spectrum is the band edge frequency and span is 1~5 MHz.
           RBW of the spectrum is 20kHz and VBW of the spectrum is 100 kHz. (LTE bandwidth
           1.4MHz).

        c. The center frequency of spectrum is the band edge frequency and span is 1~5 MHz.
           RBW of the spectrum is 30kHz and VBW of the spectrum is 100kHz. (LTE bandwidth
           3MHz)

        d. The center frequency of spectrum is the band edge frequency and span is 1~5 MHz.
           RBW of the spectrum is 50kHz and VBW of the spectrum is 200kHz. (LTE bandwidth
           5MHz)

        e. The center frequency of spectrum is the band edge frequency and span is 1~5 MHz.
           RBW of the spectrum is 100kHz and VBW of the spectrum is 300kHz. (LTE bandwidth
           10MHz)
         f. Record the max trace plot into the test report.



         3.4.4 TEST RESULTS

         The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 18 of 34


                        Test Report No.: RF181008W004-1



         3.5 CONDUCTED SPURIOUS EMISSIONS

         3.5.1 LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT

         The power of any emission outside of the authorized operating frequency ranges must be
         attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The
         emission limit equal to –13dBm.

         3.5.2 TEST PROCEDURE

          a. The EUT makes a phone call to the communication simulator. All measurements were
             done at low, middle and high operational frequency range.
          b. Measuring frequency range is from 9 kHz to 9GHz. 10dB attenuation pad is
             connected with spectrum. RBW=1MHz and VBW=3MHz is used for conducted
             emission measurement.

         3.5.3 TEST SETUP



             COMMUNICATION
               SIMULATOR                            POWER SPLITTER                                         SPECTRUM
                                                                                                           ANALYZER


                                                                                              10dB ATTENUATION
                                                                                              PAD
                                                             EUT




         3.5.4 TEST RESULTS

         The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan        Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan     Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 19 of 34


                        Test Report No.: RF181008W004-1


         3.6 RADIATED EMISSION MEASUREMENT

         3.6.1 LIMITS OF RADIATED EMISSION MEASUREMENT

         The power of any emission outside of the authorized operating frequency ranges must be
         attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The
         emission limit equal to –13dBm.

         3.6.2 TEST PROCEDURES
          a. Substitution method is used for E.I.R.P measurement. In the semi-anechoic chamber,
             EUT placed on the 0.8m height of Turn Table, rotated the table around 360 degrees to
             search the maximum radiation power and receiver antenna shall be rotated vertical
             and horizontal polarization and moved height from 1m to 4m to find the maximum
             polar radiated power. The “Read Value” is the spectrum reading the maximum
             power value.
          b. The substitution horn antenna is substituted for EUT at the same position and signals
             generator export the CW signal to the substitution antenna via a TX cable. Rotated the
             Turn Table and moved receiving antenna to find the maximum radiation power. Adjust
             output power level of S.G to get a Value of spectrum reading equal to “Read Value
             “ of step a. Record the power level of S.G
          c. EIRP = Output power level of S.G – TX cable loss + Antenna gain of substitution
             horn.
          d. E.R.P power can be calculated form E.I.R.P power by subtracting the gain of dipole,
             E.R.P power = E.I.P.R power - 2.15dBi.

         NOTE: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 1MHz/3MHz.


         3.6.3 DEVIATION FROM TEST STANDARD

         No deviation




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 20 of 34


                        Test Report No.: RF181008W004-1


         3.6.4 TEST SETUP


         <Below 30MHz>




         < Frequency Range 30MHz~1GHz >

                                                                            Ant. Tower
                                                                                                       1-4m
                                                           3m
                                EUT

                                                    Turn Table

                          0.8m


                                                          Ground Plane

                                                         Spectrum




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 21 of 34


                        Test Report No.: RF181008W004-1



           < Frequency Range above 1GHz >



                                                                           Ant. Tower                1-4m
                                                                                                     Variable
                     EUT&                                   3m
                     Support Units
                                                Turn Table
                                                                  Absorber
                        150cm


                                                         Ground Plane
                                                         Test
                                                         Receiver




         For the actual test configuration, please refer to the attached file (Test Setup Photo).




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 22 of 34


                        Test Report No.: RF181008W004-1


         3.6.5 TEST RESULTS
          BELOW 1GHz WORST-CASE DATA
          9 KHz – 30 MHz data: the amplitude of spurious emissions attenuated more than 20 dB below the
          permissible value is not required in the report.
          30 MHz – 1GHz data:

         LTE Band 5:
             MODE                         TX channel 20525                  FREQUENCY RANGE                 Below 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          23deg. C, 70%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 23 of 34


                        Test Report No.: RF181008W004-1



             MODE                         TX channel 20525                  FREQUENCY RANGE                 Below 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          23deg. C, 70%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 24 of 34


                        Test Report No.: RF181008W004-1

         ABOVE 1GHz DATA
         Note: For higher frequency, the emission is too low to be detected.

         LTE Band 5

         CHANNEL BANDWIDTH: 1.4MHz / QPSK

         CH20407
             MODE                         TX channel 20407                  FREQUENCY RANGE                 Above 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          26deg. C, 56%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 25 of 34


                        Test Report No.: RF181008W004-1



             MODE                         TX channel 20407                  FREQUENCY RANGE                 Above 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          26deg. C, 56%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 26 of 34


                        Test Report No.: RF181008W004-1



         CH20525
             MODE                         TX channel 20525                  FREQUENCY RANGE                 Above 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          26deg. C, 56%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 27 of 34


                        Test Report No.: RF181008W004-1



             MODE                         TX channel 20525                  FREQUENCY RANGE                 Above 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          26deg. C, 56%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 28 of 34


                        Test Report No.: RF181008W004-1



         CH20643
             MODE                         TX channel 20643                  FREQUENCY RANGE                 Above 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          26deg. C, 56%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 29 of 34


                        Test Report No.: RF181008W004-1



             MODE                         TX channel 20643                  FREQUENCY RANGE                 Above 1000MHz
             ENVIRONMENTAL                                                                                  DC 5V from
                                          26deg. C, 56%RH                   INPUT POWER
             CONDITIONS                                                                                     adapter
             TESTED BY                    Star Le
                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 30 of 34


                        Test Report No.: RF181008W004-1



         3.7 PEAK TO AVERAGE RATIO

         3.7.1 LIMITS OF PEAK TO AVERAGE RATIO MEASUREMENT

         In measuring transmissions in this band using an average power technique, the peak
         to-average ratio (PAR) of the transmission may not exceed 13 dB

         3.7.2 TEST SETUP


             COMMUNICATION
               SIMULATOR                            POWER SPLITTER                                         SPECTRUM
                                                                                                           ANALYZER


                                                                                              10dB ATTENUATION
                                                                                              PAD
                                                             EUT




         3.7.3 TEST PROCEDURES

         1. Set resolution/measurement bandwidth ≥ signal’s occupied bandwidth;
         2. Set the number of counts to a value that stabilizes the measured CCDF curve;
         3. Record the maximum PAPR level associated with a probability of 0.1%.



         3.7.4 TEST RESULTS

         The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan        Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan     Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 31 of 34


                        Test Report No.: RF181008W004-1


         4 PHOTOGRAPHS OF THE TEST CONFIGURATION

         Please refer to the attached file (Test Setup Photo).




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 32 of 34


                        Test Report No.: RF181008W004-1



         5 INFORMATION ON THE TESTING LABORATORIES

         We, BV 7LAYERS COMMUNICATIONS TECHNOLOGY (SHENZHEN) CO. LTD., were
         founded in 2015 to provide our best service in EMC, Radio, Telecom and Safety
         consultation. Our laboratories are accredited and approved according to ISO/IEC 17025.
         If you have any comments, please feel free to contact us at the following:

         Shenzhen EMC/RF Lab:
         Tel: +86-755-88696566
         Fax: +86-755-88696577


         Email: customerservice.dg@cn.bureauveritas.com
         Web Site: www.adt.com.tw

         The address and road map of all our labs can be found in our web site also.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 33 of 34


                        Test Report No.: RF181008W004-1



         6 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
           CHANGES TO THE EUT BY THE LAB

         No any modifications are made to the EUT by the lab during the test.



         ---END---




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 34 of 34



Document Created: 2019-03-12 14:20:33
Document Modified: 2019-03-12 14:20:33

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC