RF Test Report-24

FCC ID: 2AEMI-B402

Test Report

Download: PDF
FCCID_4455111

                            Test Report No.: RF190606W003-2




                                                               FCC TEST REPORT
                                                                                   (PART 24)
    Applicant:                           Particle Industries,Inc


    Address:                             126 Post St,4th floor, San Francisco,CA 94108 USA


    Manufacturer or
                                         Particle Industries,Inc
    Supplier:

    Address:                             126 Post St,4th floor, San Francisco,CA 94108 USA


    Product:                             B Series B402

    Brand Name:                          Particle

    Model Name:                          B402, B402S

    FCC ID:                              2AEMI-B402

    Date of tests:                       Jun. 07, 2019 ~ Jul. 10, 2019

    The tests have been carried out according to the requirements of the following standard:

           FCC PART 24, Subpart E                                      ANSI C63.26-2015
           ANSI/TIA/EIA-603-D                                          ANSI/TIA/EIA-603-E

    CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                            Prepared by Alex Chen                                                                                   Approved by Luke Lu
                         Engineer / Mobile Department                                                                            Manager / Mobile Department




                                    Date: Jul. 18, 2019                                                                                    Date: Jul. 18, 2019
    This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
    http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person
    or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
    set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
    expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon
    request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty;
    provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you
    unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                                 No.B102, Dazu Chuangxin Mansion, North of Beihuan                                       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                                 Avenue, North Area, Hi-Tech Industrial Park, Nanshan                                    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                                                 District, Shenzhen, Guangdong, China                                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                                              Page 1 of 34


                      Test Report No.: RF190606W003-2


                                            TABLE OF CONTENTS
     RELEASE CONTROL RECORD ....................................................................................................... 4

     1    SUMMARY OF TEST RESULTS .................................................................................................. 5
         1.1 MEASUREMENT UNCERTAINTY .......................................................................................... 6
         1.2 TEST SITE AND INSTRUMENTS ............................................................................................. 7
     2 GENERAL INFORMATION ............................................................................................................. 8
         2.1 GENERAL DESCRIPTION OF EUT .......................................................................................... 8
         2.2 CONFIGURATION OF SYSTEM UNDER TEST ..................................................................... 9
         2.3 DESCRIPTION OF SUPPORT UNITS .................................................................................. 10
         2.4 TEST ITEM AND TEST CONFIGURATION .......................................................................... 10
         2.5 EUT OPERATING CONDITIONS ........................................................................................ 12
         2.6 GENERAL DESCRIPTION OF APPLIED STANDARDS ..................................................... 12
     3    TEST TYPES AND RESULTS .................................................................................................... 13
         3.1 OUTPUT POWER MEASUREMENT .................................................................................... 13
           3.1.1 LIMITS OF OUTPUT POWER MEASUREMENT ......................................................... 13
           3.1.2 TEST PROCEDURES ................................................................................................... 13
           3.1.3 TEST SETUP................................................................................................................. 14
           3.1.4 TEST RESULTS ............................................................................................................... 15
         3.2 FREQUENCY STABILITY MEASUREMENT ........................................................................ 17
           3.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT ............................................ 17
           3.2.2 TEST PROCEDURE...................................................................................................... 17
           3.2.3 TEST SETUP................................................................................................................. 17
           3.2.4 TEST RESULTS ............................................................................................................ 17
         3.3 OCCUPIED BANDWIDTH MEASUREMENT ....................................................................... 18
           3.3.1 TEST PROCEDURES ................................................................................................... 18
           3.3.2 TEST SETUP................................................................................................................. 18
           3.3.3 TEST RESULTS ............................................................................................................ 18
         3.4 BAND EDGE MEASUREMENT ............................................................................................ 19
           3.4.1 LIMITS OF BAND EDGE MEASUREMENT .................................................................. 19
           3.4.2 TEST SETUP................................................................................................................. 19
           3.4.3 TEST PROCEDURES ................................................................................................... 20
           3.4.4. TEST RESULTS .............................................................................................................. 20
         3.5 CONDUCTED SPURIOUS EMISSIONS .............................................................................. 21
           3.5.1 LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT ....................... 21
           3.5.2 TEST PROCEDURE...................................................................................................... 21
           3.5.3 TEST SETUP................................................................................................................. 21
           3.5.4 TEST RESULTS ............................................................................................................... 21
         3.6 RADIATED EMISSION MEASUREMENT ............................................................................. 22
           3.6.1 LIMITS OF RADIATED EMISSION MEASUREMENT .................................................. 22
           3.6.2 TEST PROCEDURES ................................................................................................... 22
           3.6.3 DEVIATION FROM TEST STANDARD ......................................................................... 22
           3.6.4 TEST SETUP................................................................................................................. 23
           3.6.5 TEST RESULTS ............................................................................................................ 24
         3.7 PEAK TO AVERAGE RATIO ................................................................................................. 32
           3.7.1 LIMITS OF PEAK TO AVERAGE RATIO MEASUREMENT.......................................... 32
           3.7.2 TEST SETUP................................................................................................................. 32
           3.7.3 TEST PROCEDURES ................................................................................................... 32
           3.7.4 TEST RESULTS ............................................................................................................... 32

                                                 No.B102, Dazu Chuangxin Mansion, North of Beihuan                Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                 Avenue, North Area, Hi-Tech Industrial Park, Nanshan             Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                                 District, Shenzhen, Guangdong, China                             Email: customerservice.dg@cn.bureauveritas.com
                                                                       Page 2 of 34


                     Test Report No.: RF190606W003-2

     4    INFORMATION ON THE TESTING LABORATORIES .............................................................. 33

     5 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE
     EUT BY THE LAB ............................................................................................................................ 34




                                                  No.B102, Dazu Chuangxin Mansion, North of Beihuan                 Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                  Avenue, North Area, Hi-Tech Industrial Park, Nanshan              Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                                  District, Shenzhen, Guangdong, China                              Email: customerservice.dg@cn.bureauveritas.com
                                                                        Page 3 of 34


                  Test Report No.: RF190606W003-2


                               RELEASE CONTROL RECORD

    ISSUE NO.              REASON FOR CHANGE                                                         DATE ISSUED
    RF190606W003-2         Original release                                                          Jul. 18, 2019




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 4 of 34


                  Test Report No.: RF190606W003-2



     1 SUMMARY OF TEST RESULTS
     The EUT has been tested according to the following specifications:

                                  APPLIED STANDARD: FCC Part 24 & Part 2

       STANDARD
                                       TEST TYPE                    RESULT                      REMARK
        SECTION
          2.1046       Equivalent Isotropic Radiated
                                                                      PASS       Meet the requirement of limit.
          24.232       Power
          2.1055
                       Frequency Stability                            PASS       Meet the requirement of limit.
          24.235
          2.1049
                       Occupied Bandwidth                             PASS       Meet the requirement of limit.
        24.238(b)
        24.232(d)      Peak to average ratio                          PASS       Meet the requirement of limit.

        24.238(b)      Band Edge Measurements                         PASS       Meet the requirement of limit.

          2.1051
                       Conducted Spurious Emissions                   PASS       Meet the requirement of limit.
          24.238
          2.1053                                                                 Meet the requirement of limit.
                       Radiated Spurious Emissions                    PASS       Minimum passing margin is
          24.238                                                                 -15.92dB at 40.670MHz.
     Note: The product Particle SARA-R410M-02B-00 is fully integrated the LTE Cat-M1 Module
     SARA-R410M (FCC ID: XPY2AGQN4NNN), no other modification on the LTE Cat-M1 Module
     radio parameter such as power, frequency range, modulation etc., for this report only test
     Effective Radiated Power and Radiated Spurious Emissions, other test data please refer the
     module report. The Module report number has been noted in this report, Please refer to this
     report for details.




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                        District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 5 of 34


                  Test Report No.: RF190606W003-2




     1.1    MEASUREMENT UNCERTAINTY

     Where relevant, the following measurement uncertainty levels have been
     estimated for tests performed on the EUT as specified in CISPR 16-4-2:
                        MEASUREMENT                                          UNCERTAINTY
                   Effective Radiated Power                                       ±4.48dB
                       Frequency Stability                                       ±39.27Hz
                       Radiated emissions                                         ±4.48dB
                    Conducted emissions                                            ±2 dB
                 Occupied Channel Bandwidth                                      ±21.7KHz
                  Band Edge Measurements                                          ±4.48dB
                    Peak to average ratio                                         ±0.76dB

     This uncertainty represents an expanded uncertainty expressed at approximately
     the 95% confidence level using a coverage factor of k=2.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 6 of 34


                  Test Report No.: RF190606W003-2


     1.2 TEST SITE AND INSTRUMENTS
   Equipment                Manufacturer       Model No.           Serial No.            Last Cal.        Next Cal.
   MXE EMI Receiver         KEYSIGHT           N9038A-544          MY54450026            Feb. 26,19       Feb. 25,20
   EXA Signal Analyzer      KEYSIGHT           N9010A-526          MY54510322            Feb. 26,19       Feb. 25,20
   Bilog Antenna 1          ETS-LINDGREN       3143B               00161964              Feb. 26,19       Feb. 25,20
   Bilog Antenna 2          ETS-LINDGREN       3143B               00161965              Feb. 26,19       Feb. 25,20
   Horn Antenna 1           ETS-LINDGREN       3117                00168728              Feb. 26,19       Feb. 25,20
   Horn Antenna 2           ETS-LINDGREN       3117                00168692              Nov. 30, 18      Nov. 29, 19
                                               QWH-SL-18-40
   Horn Antenna
                            N/A                -K-SG/QMS-00        15433                 Nov. 21, 18 Nov. 20, 19
   (18GHz-40GHz)
                                               361
   Radio
   Communication            ANRITSU            MT8820C             6201465426            Feb. 26,19 Feb. 25,20
   Analyzer
   Signal Pre-Amplifier     EMSI    EMC 9135      980249                                 Jul. 09,19       Jul. 08,20
   Signal Pre-Amplifier     EMSI    EMC 012645B 980257                                   Jul. 09,19       Jul. 08,20
   Signal Pre-Amplifier     EMSI    EMC 184045B 980259                                   Jul. 09,19       Jul. 08,20
   3m Semi-anechoic                               Euroshieldpn-
                       ETS-LINDGREN 9m*6m*6m                                             Feb. 26,19 Feb. 25,20
   Chamber                                        CT0001143-1216
   Test Software       E3           V 9.160323    N/A                                    N/A              N/A
                                    ADT_Radiated
   Test Software       ADT                        N/A                                    N/A              N/A
                                    _V7.6.15.9.2
                                    50HF-010-SM
   10dB Attenuator     JFW/USA                    1505                                   Jul. 09,19       Jul. 08,20
                                    A
   Power Meter         Anritsu      ML2495A       1506002                                Feb. 26,19 Feb. 25,20
   Power Sensor        Anritsu      MA2411B       1339352                                Feb. 26,19 Feb. 25,20
   Humid & Temp                     ITH-120-45-CP
                       Juyi                       IAA1504-001                            Jul. 09,19       Jul. 08,20
   Programmable Tester              -AR
   MXG Analog
   Microvave           KEYSIGHT     N5183A        MY50143024                             Feb. 26,19 Feb. 25,20
   Signal Generator
        NOTE: 1. The calibration interval of the above test instruments is 12 months or 24 months and
                 the calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                2. The test was performed in 3m Semi-anechoic Chamber and RF Oven Room.
                3. The horn antenna is used only for the measurement of emission frequency above
                    1GHz if tested.
                4. The FCC Site Registration No. is 525120; The Designation No. is CN1171.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 7 of 34


                  Test Report No.: RF190606W003-2



     2 GENERAL INFORMATION
     2.1 GENERAL DESCRIPTION OF EUT
      PRODUCT                                  B Series B402
      BRAND NAME                               Particle
      MODEL NAME                               B402, B402S

      POWER SUPPLY                             3.8Vdc (Li-ion, battery)
      MODULATION TYPE                          LTE Band 2: QPSK, 16QAM
                                               LTE Band 2
      FREQUENCY RANGE                                                    1850.7MHz ~ 1909.3MHz
                                               Channel Bandwidth: 1.4MHz
                                               LTE Band 2
      MAX. EIRP POWER                                                    404mW
                                               Channel Bandwidth: 1.4MHz
                                               LTE Band 2                QPSK: 1M12G7D
      EMISSION DESIGNATOR
                                               Channel Bandwidth: 1.4MHz 16QAM: 1M12W7D
      ANTENNA TYPE                             Fixed External antenna with 3.5dBi gain
      HW VERSION                               V1.00
      SW VERSION                               V1.2.1
      I/O PORTS                                Refer to user’s manual
      CABLE SUPPLIED                           N/A
     NOTE:
     1. For a more detailed features description, please refer to the manufacturer’s specifications or
        the user's manual.
     2.
     3. For the test results, the EUT had been tested with all conditions. But only the worst case
         was shown in test report.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 8 of 34


                  Test Report No.: RF190606W003-2

     2.2     CONFIGURATION OF SYSTEM UNDER TEST

     FOR RADIATION EMISSION TEST




                                                     EUT      (Powered from AC Adapter)


           Test table



                                               Universal Radio
                                               Communication
                                                   Tester


           *Kept in a remote area



     FOR CONDUCTED & E.I.R.P. TEST




                                                     EUT      (Powered from battery)



           Test table



                                                Universal Radio
                                                Communication
                                                    Tester



           *Kept in a remote area




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 9 of 34


                       Test Report No.: RF190606W003-2

     2.3      DESCRIPTION OF SUPPORT UNITS

       The EUT has been tested as an independent unit together with other
       necessary accessories or support units. The following support units or
       accessories were used to form a representative test configuration during the
       tests.

        NO.       PRODUCT              BRAND           MODEL NO.                    SERIAL NO.                    FCC ID
         1          DC source        LONG WEI          PS-6403D                      010934269                       N/A
         2              PC                HP            A6608CN                     3CR83825X3                       N/A
         3              USB              N/A               N/A                           N/A                         N/A
         4             Battery           N/A               N/A                           N/A                         N/A


        NO.                   SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
         1       DC Line: Unshielded, Detachable 1.0m
         2       AC Line: Unshielded, Detachable 1.5m
         3       N/A
         4 N/A
         NOTE:
         1. All power cords of the above support units are non shielded (1.8m).


     2.4      TEST ITEM AND TEST CONFIGURATION

     Pre-Scan has been conducted to determine the worst-case mode from all
     possible combinations between available modulations, data rates, XYZ axis and
     antenna ports
     The worst case in EIRP and radiated emission was found when positioned on
     X-plane for LTE. Following channel(s) was (were) selected for the final test as
     listed below:

         EUT
      CONFIGURE                                         DESCRIPTION
        MODE

             -           EUT + Battery with LTE link




                                             No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                             Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                             District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 10 of 34


                    Test Report No.: RF190606W003-2


     LTE BAND 2
        EUT
                                    AVAILABLE                            CHANNEL
     CONFIGURE       TEST ITEM                    TESTED CHANNEL                  MODULATION                     MODE
                                     CHANNEL                            BANDWIDTH
       MODE
           -            EIRP       18607 to 19193 18607, 18900, 19193      1.4MHz     QPSK,16QAM           1 RB / 0 RB Offset
                     RADIATED
           -                       18607 to 19193 18607, 18900, 19193      1.4MHz         QPSK             1 RB / 0 RB Offset
                     EMISSION


     TEST CONDITION:

                   TEST ITEM              ENVIRONMENTAL CONDITIONS                  INPUT POWER                 TESTED BY
                     EIRP                         25deg. C, 57%RH               3.8Vdc from Battery                Star Le
               RADIATED EMISSION                  23deg. C, 70%RH               3.8Vdc from Battery                Star Le




                                          No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                          Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                          District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 11 of 34


                  Test Report No.: RF190606W003-2

     2.5      EUT OPERATING CONDITIONS

      The EUT makes a call to the communication simulator. The communication
     simulator station system controlled a EUT to export maximum output power
     under transmission mode and specific channel frequency



     2.6      GENERAL DESCRIPTION OF APPLIED STANDARDS

      The EUT is a RF product. According to the specifications of the manufacturer, it
     must comply with the requirements of the following standards:

     FCC 47 CFR Part 2
     FCC 47 CFR Part 24
     KDB 971168 D01 Power Meas License Digital Systems v03r01
     ANSI/TIA/EIA-603-D
     ANSI/TIA/EIA-603-E
     ANSI C63.26-2015

     NOTE: All test items have been performed and recorded as per the above standards.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 12 of 34


                  Test Report No.: RF190606W003-2


     3     TEST TYPES AND RESULTS

     3.1     OUTPUT POWER MEASUREMENT


     3.1.1     LIMITS OF OUTPUT POWER MEASUREMENT

         Mobile and portable stations are limited to 2 watts EIRP.


     3.1.2     TEST PROCEDURES

     EIRP MEASUREMENT:

      a. All measurements were done at low, middle and high operational frequency
         range. RBW and VBW is 10MHz for LTE mode.

      b. Substitution method is used for E.I.R.P measurement. In the semi-anechoic
         chamber, EUT placed on the 0.8m height of Turn Table, rotated the table
         around 360 degrees to search the maximum radiation power and receiver
         antenna shall be rotated vertical and horizontal polarization and moved
         height from 1m to 4m to find the maximum polar radiated power. The
         “Read Value” is the spectrum reading the maximum power value.

      c. The substitution horn antenna is substituted for EUT at the same position
         and signals generator export the CW signal to the substitution antenna via a
         tx cable. Rotated the Turn Table and moved receiving antenna to find the
         maximum radiation power. Adjust output power level of S.G to get a Value of
         spectrum reading equal to “Read Value“ of step b. Record the power
         level of S.G

      d. EIRP = Output power level of S.G – TX cable loss + Antenna gain of
         substitution horn.

     CONDUCTED POWER MEASUREMENT:

           The EUT was set up for the maximum power with GSM, GPRS, EDGE &
           WCDMA link data modulation and link up with simulator. Set the EUT to
           transmit under low, middle and high channel and record the power level shown
           on simulator.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 13 of 34


                  Test Report No.: RF190606W003-2

     3.1.3     TEST SETUP

     EIRP / ERP Measurement:
     <Radiated Emission below or equal 1 GHz>
                                                                 Ant. Tower
                                                                                              1-4m
                                                3m
                       EUT

                                         Turn Table

                 0.8m


                                              Ground Plane

                                              Spectrum



       <Radiated Emission above 1 GHz>


                                                                     Ant. Tower                 1-4m
                                                                                                Variable
                 EUT&                                  3m
                 Support Units
                                          Turn Table
                                                            Absorber
                    150cm


                                                   Ground Plane
                                                   Test
                                                   Receiver



     For the actual test configuration, please refer to the attached file (Test Setup
     Photo).

     CONDUCTED POWER MEASUREMENT:


                       COMMUNICATION
                                                                              EUT
                         SIMULATOR




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 14 of 34


                  Test Report No.: RF190606W003-2

     3.1.4 TEST RESULTS

     AVERAGE CONDUCTED OUTPUT POWER (dBm)
     Base on verify the Conducted Power is the same with module test report
     (SD72128174-0517B) by lab, the test results please refer the module Report No.:
     SD72128174-0517B, and the pre-scan data as below.


                                                        LTE Band 2


           modulation             bandwidth               channels                 Frequency            Tx Average(dBm)

                                                            18607                    1850.7                     24.71
             QPSK                  1.4 MHz                  18900                    1880.0                     24.72
                                                            19193                    1909.3                     24.39
                                                            18607                    1850.7                     24.71
             16QAM                 1.4 MHz                  18900                    1880.0                     24.70
                                                            19193                    1909.3                     24.52




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 15 of 34


                  Test Report No.: RF190606W003-2

     LTE BAND 2
     CHANNEL BANDWIDTH: 1.4MHz QPSK

                    Frequency      SPA LVL        Correction                                         Polarization           LIMIT
       Channel                                                     EIRP(dBm)        EIRP(mW)
                      (MHz)         (dBm)         Factor(dB)                                            (H/V)                (W)

        18607         1850.7           -18.77         43.83            25.06           320.92               H                  2
        18900         1880.0           -17.68         43.57            25.89           388.15               H                  2
        19193         1908.3           -18.25         44.32            26.07           404.48               H                  2
        18607         1850.7           -21.34         46.41            25.07           321.44               V                  2
        18900         1880.0           -21.89         47.07            25.18           329.61               V                  2
        19193         1908.3           -21.90         45.88            23.98           250.26               V                  2




     CHANNEL BANDWIDTH: 1.4MHz 16QAM

                    Frequency      SPA LVL        Correction                                         Polarization           LIMIT
       Channel                                                     EIRP(dBm)        EIRP(mW)
                      (MHz)         (dBm)         Factor(dB)                                            (H/V)                (W)

        18607         1850.7           -19.64         43.83            24.19           262.66               H                  2
        18900         1880.0           -18.61         43.57            24.96           313.33               H                  2
        19193         1908.3           -19.21         44.32            25.11           324.26               H                  2
        18607         1850.7           -22.21         46.41            24.20           263.09               V                  2
        18900         1880.0           -22.82         47.07            24.25           266.07               V                  2
        19193         1908.3           -22.86         45.88            23.02           200.63               V                  2


     REMARKS: 1. EIRP Output Power (dBm) = SPA LVL (dBm) + Correction Factor (dB).
                    2. Correction factor (dB) = Free Space Loss + Antenna Factor + Cable Loss




                                         No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                         Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                         District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 16 of 34


                  Test Report No.: RF190606W003-2

     3.2     FREQUENCY STABILITY MEASUREMENT


     3.2.1     LIMITS OF FREQUENCY STABILIITY MEASUREMENT

     The frequency stability shall be sufficient to ensure that the fundamental emission
     stays within the authorized frequency block.


     3.2.2     TEST PROCEDURE
      a. Device is placed at the oven room. The oven room could control the
         temperatures and humidity. Power warm up is at least 15 min and power
         applied should perform before recording frequency error.
      b. EUT is connected the external power supply to control the DC input power.
         The test voltage range is from minimum to maximum working voltage. Each
         step shall be record the frequency error rate.
      c. The temperature range step is 10 degrees in this test items. All temperature
         levels shall be hold the ±0.5℃ during the measurement testing. The each
         temperature step shall be at least 0.5 hours, consider the EUT could be test
         under the stability condition.
        NOTE: The frequency error was recorded frequency error from the communication simulator.


     3.2.3     TEST SETUP


                                                                                 OVEN ROOM
                COMMUNICATION
                  SIMULATOR
                                                                                 ANTENNA




                                                                     EXTERNAL POWER SOURCE

                                                                   EUT
               DC POWER SUPPLY




     3.2.4     TEST RESULTS

     The test results please refer the module Report No.:SD72128174-0517B.


                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 17 of 34


                  Test Report No.: RF190606W003-2

     3.3     OCCUPIED BANDWIDTH MEASUREMENT

     3.3.1     TEST PROCEDURES

       The EUT makes a call to the communication simulator. All measurements were
     done at low, middle and high operational frequency range. The communication
     simulator station system controlled a EUT to export maximum output power
     under transmission mode and specific channel frequency. Use OBW
     measurement function of Spectrum analyzer to measure 99 % occupied
     bandwidth.


     3.3.2     TEST SETUP


         COMMUNICATION
           SIMULATOR                          POWER SPLITTER                                       SPECTRUM
                                                                                                   ANALYZER


                                                                                      10dB ATTENUATION
                                                                                      PAD
                                                       EUT




     3.3.3     TEST RESULTS

     The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 18 of 34


                  Test Report No.: RF190606W003-2

     3.4     BAND EDGE MEASUREMENT


     3.4.1     LIMITS OF BAND EDGE MEASUREMENT

        Power of any emission outside of the authorized operating frequency ranges
        must be attenuated below the transmitting power (P) by a factor of at least 43 +
        10 log(P) dB. In the 1 MHz bands immediately outside and adjacent to the
        frequency block a resolution bandwidth of at least one percent of the emission
        bandwidth of the fundamental emission of the transmitter may be employed.


     3.4.2     TEST SETUP



         COMMUNICATION
           SIMULATOR                          POWER SPLITTER                                       SPECTRUM
                                                                                                   ANALYZER


                                                                                      10dB ATTENUATION
                                                                                      PAD
                                                       EUT




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 19 of 34


                  Test Report No.: RF190606W003-2




     3.4.3     TEST PROCEDURES

    a.    All measurements were done at low and high operational frequency range.
    b.    The center frequency of spectrum is the band edge frequency and span is
          1~5 MHz. RBW of the spectrum is 20kHz and VBW of the spectrum is 100
          kHz. (LTE bandwidth 1.4MHz)
     c.   Record the max trace plot into the test report.




     3.4.4. TEST RESULTS

     The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 20 of 34


                  Test Report No.: RF190606W003-2

     3.5     CONDUCTED SPURIOUS EMISSIONS


     3.5.1     LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT

        The power of any emission outside of the authorized operating frequency ranges
        must be attenuated below the transmitting power (P) by a factor of at least 43 +
        10 log(P) dB. The emission limit equal to –13dBm.


     3.5.2     TEST PROCEDURE

      a. The EUT makes a phone call to the communication simulator. All
         measurements were done at low, middle and high operational frequency
         range.
      b. Measuring frequency range is from 9 kHz to 19.1GHz. 10dB attenuation pad
         is connected with spectrum. RBW=1MHz and VBW=3MHz is used for
         conducted emission measurement.


     3.5.3     TEST SETUP



         COMMUNICATION
           SIMULATOR                          POWER SPLITTER                                       SPECTRUM
                                                                                                   ANALYZER


                                                                                      10dB ATTENUATION
                                                                                      PAD
                                                       EUT




     3.5.4 TEST RESULTS

     The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 21 of 34


                  Test Report No.: RF190606W003-2


     3.6     RADIATED EMISSION MEASUREMENT


     3.6.1     LIMITS OF RADIATED EMISSION MEASUREMENT

       The power of any emission outside of the authorized operating frequency ranges
       must be attenuated below the transmitting power (P) by a factor of at least 43 +
       10 log(P) dB. The emission limit equal to –13dBm.


     3.6.2     TEST PROCEDURES
      a. Substitution method is used for E.I.R.P measurement. In the semi-anechoic
         chamber, EUT placed on the 0.8m height of Turn Table, rotated the table
         around 360 degrees to search the maximum radiation power and receiver
         antenna shall be rotated vertical and horizontal polarization and moved
         height from 1m to 4m to find the maximum polar radiated power. The
         “Read Value” is the spectrum reading the maximum power value.
      b. The substitution horn antenna is substituted for EUT at the same position
         and signals generator export the CW signal to the substitution antenna via a
         TX cable. Rotated the Turn Table and moved receiving antenna to find the
         maximum radiation power. Adjust output power level of S.G to get a Value of
         spectrum reading equal to “Read Value “ of step a. Record the power
         level of S.G
      c. EIRP = Output power level of S.G – TX cable loss + Antenna gain of
         substitution horn.

     NOTE: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
           1MHz/3MHz.



     3.6.3     DEVIATION FROM TEST STANDARD

           No deviation




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 22 of 34


                  Test Report No.: RF190606W003-2


      3.6.4    TEST SETUP


     < Frequency Range 30MHz~1GHz >

                                                                 Ant. Tower
                                                                                              1-4m
                                                3m
                       EUT

                                         Turn Table

                 0.8m


                                              Ground Plane

                                              Spectrum




     < Frequency Range above 1GHz >

                                                                 Ant. Tower                   1-4m
                                                                                              Variable
              EUT&                                3m
              Support Units
                                       Turn Table
                                                       Absorber
                150cm


                                              Ground Plane
                                               Test
                                               Receiver




      For the actual test configuration, please refer to the attached file (Test Setup
     Photo).




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 23 of 34


                  Test Report No.: RF190606W003-2

     3.6.5     TEST RESULTS

      BELOW 1GHz WORST-CASE DATA

      30 MHz – 1GHz data:

     LTE Band 2
     CHANNEL BANDWIDTH: 1.4MHz / QPSK


      MODE                         TX channel 18900               FREQUENCY RANGE                 Below 1000MHz
      ENVIRONMENTAL
                                   23deg. C, 70%RH                INPUT POWER                     DC 3.8V
      CONDITIONS
      TESTED BY                    Star Le
                       ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 24 of 34


                  Test Report No.: RF190606W003-2



      MODE                         TX channel 18900               FREQUENCY RANGE                 Below 1000MHz
      ENVIRONMENTAL
                                   23deg. C, 70%RH                INPUT POWER                     DC 3.8V
      CONDITIONS
      TESTED BY                    Star Le
                         ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 25 of 34


                  Test Report No.: RF190606W003-2

     ABOVE 1GHz DATA
     Note: For higher frequency, the emission is too low to be detected.

     LTE Band 2
     CHANNEL BANDWIDTH: 1.4MHz / QPSK

     CH 18607
     MODE                         TX channel 18607               FREQUENCY RANGE                 Above 1000MHz
     ENVIRONMENTAL
                                  23deg. C, 70%RH                INPUT POWER                     DC 3.8V
     CONDITIONS
     TESTED BY                    Star Le
                       ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 26 of 34


                  Test Report No.: RF190606W003-2



      MODE                         TX channel 18607               FREQUENCY RANGE                 Above 1000MHz
      ENVIRONMENTAL
                                   23deg. C, 70%RH                INPUT POWER                     DC 3.8V
      CONDITIONS
      TESTED BY                    Star Le
                         ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 27 of 34


                  Test Report No.: RF190606W003-2

     CH 18900
     MODE                         TX channel 18900               FREQUENCY RANGE                 Above 1000MHz
     ENVIRONMENTAL
                                  23deg. C, 70%RH                INPUT POWER                     DC 3.8V
     CONDITIONS
     TESTED BY                    Star Le
                       ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 28 of 34


                  Test Report No.: RF190606W003-2



      MODE                         TX channel 18900               FREQUENCY RANGE                 Above 1000MHz
      ENVIRONMENTAL
                                   23deg. C, 70%RH                INPUT POWER                     DC 3.8V
      CONDITIONS
      TESTED BY                    Star Le
                         ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 29 of 34


                  Test Report No.: RF190606W003-2

     CH 19193
      MODE                         TX channel 19193               FREQUENCY RANGE                 Above 1000MHz
      ENVIRONMENTAL
                                   23deg. C, 70%RH                INPUT POWER                     DC 3.8V
      CONDITIONS
      TESTED BY                    Star Le
                       ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 30 of 34


                  Test Report No.: RF190606W003-2



      MODE                         TX channel 19193               FREQUENCY RANGE                 Above 1000MHz
      ENVIRONMENTAL
                                   23deg. C, 70%RH                INPUT POWER                     DC 3.8V
      CONDITIONS
      TESTED BY                    Star Le
                         ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 31 of 34


                  Test Report No.: RF190606W003-2


     3.7    PEAK TO AVERAGE RATIO


       3.7.1    LIMITS OF peak to average ratio MEASUREMENT

     In measuring transmissions in this band using an average power technique, the
     peak to-average ratio (PAR) of the transmission may not exceed 13 dB


       3.7.2    TEST SETUP



         COMMUNICATION
           SIMULATOR                          POWER SPLITTER                                       SPECTRUM
                                                                                                   ANALYZER


                                                                                      10dB ATTENUATION
                                                                                      PAD
                                                       EUT




       3.7.3    TEST PROCEDURES

     1. Set resolution/measurement bandwidth ≥ signal’s occupied bandwidth;
     2. Set the number of counts to a value that stabilizes the measured CCDF curve;
     3. Record the maximum PAPR level associated with a probability of 0.1%.




       3.7.4 TEST RESULTS

     The test results please refer the module Report No.:SD72128174-0517B.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 32 of 34


                  Test Report No.: RF190606W003-2

     4 INFORMATION ON THE TESTING LABORATORIES

     We, BV 7LAYERS COMMUNICATIONS TECHNOLOGY (SHENZHEN) CO. LTD.,
     were founded in 2015 to provide our best service in EMC, Radio, Telecom and
     Safety consultation. Our laboratories are accredited and approved according to
     ISO/IEC 17025.
     If you have any comments, please feel free to contact us at the following:

      Shenzhen EMC/RF Lab:
      Tel: +86-755-88696566
      Fax: +86-755-88696577


      Email: customerservice.dg@cn.bureauveritas.com
      Web Site: www.adt.com.tw

     The address and road map of all our labs can be found in our web site also.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 33 of 34


                  Test Report No.: RF190606W003-2

     5    APPENDIX A – MODIFICATIONS RECORDERS FOR
          ENGINEERING CHANGES TO THE EUT BY THE LAB

     No any modifications are made to the EUT by the lab during the test.



     ---END---




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 34 of 34



Document Created: 2019-09-24 14:04:06
Document Modified: 2019-09-24 14:04:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC