RF Test Report

FCC ID: 2AEMI-ARGN

Test Report

Download: PDF
FCCID_4196497

                     Test Report No.: RF180817N043-2


                                                             TEST REPORT
     Applicant                     Particle Industries,Inc

     Address                       126 Post St, 4th floor, San Francisco, CA 94108 USA



     Manufacturer or
                                   Particle Industries,Inc
     Supplier

     Address                       126 Post St, 4th floor, San Francisco, CA 94108 USA

     Product                       Argon

     Brand Name                    Particle Industries,Inc

     Model                         ARGN

     Additional Model &
                        N/A
     Model Difference

     Date of tests                 Aug. 17, 2018 ~ Oct. 26, 2018

     the tests have been carried out according to the requirements of the following standards:

          FCC Part 15, Subpart C, Section 15.225

     CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Breeze Jiang                                                          Approved by Glyn He
                   Project Engineer / EMC Department                                                  Supervisor / EMC Department




                                                                                                             Date: Nov. 30, 2018
     This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
     http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
     replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
     report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
     representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
     expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
     Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
     material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
     and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
     acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                    Town, Dongguan City,                                          Fax: +86 769 8593 1080
Dongguan Branch
                                                                  Guangdong 523942, China                                 Email: customerservice.dg@cn.bureauveritas.com
                                                                             Page 1 of 28                                                              Report Version 1


                     Test Report No.: RF180817N043-2


                                                     TABLE OF CONTENTS
          RELEASE CONTROL RECORD ..................................................................................................... 4
          1     SUMMARY OF TEST RESULTS ............................................................................................. 5
          2      MEASUREMENT UNCERTAINTY ......................................................................................... 5
          3      GENERAL INFORMATION ..................................................................................................... 6
              3.1     GENERAL DESCRIPTION OF EUT .................................................................................... 6
              3.2     DESCRIPTION OF TEST MODES ...................................................................................... 7
                     3.2.1.   CONFIGURATION OF SYSTEM UNDER TEST ...................................................... 7
                     3.2.2.   TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................... 7
              3.3     GENERAL DESCRIPTION OF APPLIED STANDARDS ..................................................... 9
              3.4     DESCRIPTION OF SUPPORT UNITS ................................................................................ 9
          4      TEST TYPES AND RESULTS .............................................................................................. 10
              4.1.       CONDUCTED EMISSION MEASUREMENT ............................................................... 10
                     4.1.1    LIMITS OF CONDUCTED EMISSION MEASUREMENT....................................... 10
                     4.1.2    TEST INSTRUMENTS ............................................................................................ 10
                     4.1.3    TEST PROCEDURES..............................................................................................11
                     4.1.4    DEVIATION FROM TEST STANDARD ....................................................................11
                     4.1.5    TEST SETUP .......................................................................................................... 12
                     4.1.6    EUT OPERATING CONDITIONS ........................................................................... 12
                     4.1.7    TEST RESULTS ...................................................................................................... 13
              4.2.       RADIATED EMISSION AND BANDEDGE MEASUREMENT ....................................... 15
                    4.2.1     LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT .............. 15
                    4.2.2     TEST INSTRUMENTS ............................................................................................ 16
                    4.2.3     TEST PROCEDURES............................................................................................. 17
                    4.2.4     DEVIATION FROM TEST STANDARD ................................................................... 17
                    4.2.5     TEST SETUP .......................................................................................................... 18
                    4.2.6     EUT OPERATING CONDITIONS ........................................................................... 19
                    4.2.7     TEST RESULTS ...................................................................................................... 19
              4.3.       FREQUENCY TOLERANCE ......................................................................................... 21
                    4.3.1.     LIMIT OF FREQUENCY TOLERANCE ................................................................. 21
                    4.3.2.     TEST INSTRUMENTS ........................................................................................... 21
                    4.3.3.     TEST PROCEDURES ............................................................................................ 22
                    4.3.4.     DEVIATION FROM TEST STANDARD .................................................................. 22
                    4.3.5.     TEST SETUP ......................................................................................................... 22
                    4.3.6.     EUT OPERATING CONDITIONS .......................................................................... 23
                    4.3.7.     TEST RESULTS ..................................................................................................... 23

                                                      No. 34, Chenwulu Section, Guantai Rd., Houjie                           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                 Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                               Guangdong 523942, China                                Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 2 of 28                                                             Report Version 1


                      Test Report No.: RF180817N043-2


               4.4.      20dB BANDWIDTH ....................................................................................................... 24
                  4.4.1       LIMITS OF 20dB BANDWIDTH .............................................................................. 24
                  4.4.2       TEST INSTRUMENTS ............................................................................................ 24
                  4.4.3       TEST PROCEDURE ............................................................................................... 25
                  4.4.4       DEVIATION FROM TEST STANDARD ................................................................... 25
                  4.4.5       TEST SETUP .......................................................................................................... 25
                  4.4.6       EUT OPERATING CONDITION .............................................................................. 26
                  4.4.7       TEST RESULTS ...................................................................................................... 26
          5.     PHOTOGRAPHS OF THE TEST CONFIGURATION ........................................................... 27
          6.     APPENDIX A - MODIFICATIONS RECORDERS FOR                                          ENGINEERING CHANGES TO
                  THE EUT BY THE LAB ......................................................................................................... 28




                                                      No. 34, Chenwulu Section, Guantai Rd., Houjie                           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                 Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                               Guangdong 523942, China                                Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 3 of 28                                                             Report Version 1


                  Test Report No.: RF180817N043-2




                                     RELEASE CONTROL RECORD

           ISSUE NO.                REASON FOR CHANGE                                              DATE ISSUED

           RF180817N043-2           Original release                                                 Nov. 30, 2018




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                       Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 4 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2



          1 SUMMARY OF TEST RESULTS
          The EUT has been tested according to the following specifications:

                                    APPLIED STANDARD: FCC Part 15, Subpart C
           STANDARD
                        TEST TYPE AND LIMIT                           RESULT                  REMARK
            SECTION
          15.207    AC Power Conducted Emission                          PASS      Meet the requirement of limit.
          15.225              The field strength of any
                                                                         PASS      Meet the requirement of limit.
          (a)&(b)&(c)         emissions within the band
                              The field strength of any
          15.225 (d)          emissions appearing outside of             PASS      Meet the requirement of limit.
                              the 13.110-14.010 MHz band

          15.225 (e)          Frequency tolerance                        PASS      Meet the requirement of limit.

          15.215 (c)          20dB Bandwidth                             PASS      Meet the requirement of limit.

          15.203              Antenna Requirement                        PASS      No antenna connector is used.



          2 MEASUREMENT UNCERTAINTY
          Where relevant, the following measurement uncertainty levels have been estimated for
          tests performed on the EUT as specified in CISPR 16-4-2:
                       MEASUREMENT                           FREQUENCY                        UNCERTAINTY
                     Conducted emissions                      9kHz~30MHz                             2.70dB
                                                             9KHz ~ 30MHz                            2.16dB
                                                           30MHz ~ 1GMHz                             3.76dB
                      Radiated emissions
                                                            1GHz ~ 18GHz                             4.84dB
                                                            18GHz ~ 40GHz                            4.96dB
          This uncertainty represents an expanded uncertainty expressed at approximately the
          95% confidence level using a coverage factor of k=2.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                          Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                 Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 5 of 28                                                  Report Version 1


                         Test Report No.: RF180717N013-2



          3 GENERAL INFORMATION

          3.1 GENERAL DESCRIPTION OF EUT
            PRODUCT                             Argon
            MODEL NO.                           ARGN
            FCC ID                2AEMI-ARGN
                                  Li+ PIN /Battery connector: DC 3.7V from Li-ion Battery or
            POWER SUPPLY
                                  VUSB PIN /USB connector :DC 5V from USB Host Unit
            MODULATION TECHNOLOGY NFC
            MODULATION TYPE                     ASK
            OPERATING FREQUENCY                 13.56MHz
            NUMBER OF CHANNEL                   1
            ANTENNA TYPE                        Loop antenna
            I/O PORTS                           Refer to user’s manual
            CABLE SUPPLIED                      N/A

           NOTE:
          1. For a more detailed features description, please refer to the manufacturer’s specifications or the
             user's manual.
          2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown
             in test report.
          3. Please refer to the EUT photo document (Reference No.: 180817N043) for detailed product photo.
          4. The EUT is wireless module, it no any accessories.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                  Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 6 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013—2



          3.2     DESCRIPTION OF TEST MODES

          The EUT only have one channel.
         |      CHANNEL         _| FREQUENCY (MHz) |
         |         4            |       13.56      |

          3.2.1. CONFIGURATION OF SYSTEM UNDER TEST
                   Please see section 5 photograph of the test configuration for reference.


          3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL
          Pre—Scan has been conducted to determine the worst—case mode from all possible
          combinations between available modulations, data rates, XYZ axis and antenna ports
          The worst case was found when positioned on X axis for radiated emission. Following
          channel(s) was (were) selected for the final test as listed below:

              EUT CONFIGURE                  APPLICABLE TO
                                                                                                   DESCRIPTION
                  MODE              RE   |    FT    | PLC | BW
                    A               ~    |     ~    |    —    |    V                       Powered by Fully Battery
                    B               =    |     =    |    ~    |    —                         Powered by Adapter

                 Where    RE: Radiated Emission                               FT: Frequency tolerance
                          PLC: Power Line Conducted Emission                   BW: 20dB Bandwidth




             RADIATED EMISSION TEST:

          K      —Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                 between available modulations, XYZ axis, antenna ports (if EUT with antenna diversity architecture)
                 and packet type.
          KX     —Following channel(s) was (were) selected for the final test as listed below.

                      EUT
                  CONFIGURE| TEstED cHanneL ‘ESTED FREQUENCY                           popyLATION TYPE                    AxIS
                     MODE                         (MHZ)
                       A    |       4             13.56      |                                 ASK                |          x          |




                                                   No. 34, Chenwulu Section, Guantai Rd., Houjie                 Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                               Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                                             Guangdong 523942, China                    Email: customerservice.dg@cn.bureauveritas.com

                                                                   Page 7 of 28                                                      Report Version 1


                             Test Report No.: RF180717N013—2
         B U R E A U
         V E R I TA S




          FREQUENCY TOLERANCE:

          K      This item includes all test value of each mode, but only includes spectrum plot of worst value of
                 each mode.
          K      Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                 between available modulations, antenna ports (if EUT with antenna diversity architecture), and
                 packet types.
          KX     —Following channel(s) was (were) selected for the final test as listed below.

                        EUT
                   CONFIGURE| TESTED CHANNEL
                                                    TESTED FREQUENCY            MODULATION TYPE                 AXIS
                      MODE                                  (MHZ)
                        A       |       4                   13.56          |            ASK             |          x          |




          POWER LINE CONDUCTED EMISSION TEST:

          K      —This item includes all test value of each mode, but only includes spectrum plot of worst value of
                 each mode.
          K      Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                 between available modulations, antenna ports (if EUT with antenna diversity architecture), and
                 packet types.
          KX     —Following channel(s) was (were) selected for the final test as listed below.

                       EUT
                   CONFIGURE| TESTED CHANNEL        TESTED FREQUENCY            MODULATION TYPE                 AXIS
                      MODE                                (MHZ)
                         s      |       1                   13.56          |            ASK             |          x          |



          20dB_ BANDWIDTH:

          K      —This item includes all test value of each mode, but only includes spectrum plot of worst value of
                 each mode.
          K      Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                 between available modulations, antenna ports (if EUT with antenna diversity architecture), and
                 packet types.
          K      Following channel(s) was (were) selected for the final test as listed below.

                       EUT
                   CONFIGURE| TESTED CHANNEL        TESTED FREQUENCY            MODULATION TYPE                 AXIS
                      MODE                                (MHZ)
                        A       |       1                   13.56          |            ASK             |          x          |




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                       Town, Dongguan City,                           Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                  Email: customerservice.dg@cn.bureauveritas.com

                                                            Page 8 of 28                                                   Report Version 1


                         Test Report No.: RF180717N013-2


          TEST CONDITION:

                                                                           TEST VOLTAGE
                  APPLICABLE TO     ENVIRONMENTAL CONDITIONS                                               TESTED BY
                                                                             (SYSTEM)
                        RE               25deg. C, 53%RH              DC3.7V from Fully Battery              Xue Wang
                        FT               25deg. C, 53%RH              DC3.7V from Fully Battery              Xue Wang
                       PLC               20deg. C, 56%RH                  DC 5V from Adapter                   Sen He
                        BW               25deg. C, 60%RH              DC3.7V from Fully Battery            Robert Cheng


          3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS

          The EUT is a RF Product. According to the specifications of the manufacturer, it must
          comply with the requirements of the following standards:


          FCC Part 15, Subpart C. Section 15.225
          ANSI C63.10-2013

          All test items have been performed and recorded as per the above standards.
          NOTE: 1. All test items have been performed and recorded as per the above standards.
                      2. It has been verified to comply with the requirements of FCC Part 15, Subpart B, Class B
                         (sDOC). The test report has been issued separately.


          3.4      DESCRIPTION OF SUPPORT UNITS


            The EUT has been tested as an independent unit together with other necessary
           accessories or support units. The following support units or accessories were used to
           form a representative test configuration during the tests.
           NO.      PRODUCT            BRAND             MODEL NO.            SERIAL NO.                       FCC ID
            1         DC source       LONG WEI            PS-6403D             010934269                        N/A
            2      Li-ion Battery        N/A               DC3.7V                 N/A                           N/A
            3         Adapter            N/A             DC5V 1.5A                N/A                           N/A
            4      Mobile phone      mobile Phone      Galaxy S9+          SM-G9650/DS                          N/A
            5      Mobile phone        APPLE           iPhone X            MQA52CH/A                            N/A

           NO.               SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
            1     DC Line: Unshielded, Detachable 1.0m
            2     N/A
            3     USB Line: Unshielded, Detachable 0.6m
           4, 5   N/A

          NOTE: All power cords of the above support units are non-shielded (1.8m).



                                           No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 9 of 28                                                     Report Version 1


                         Test Report No.: RF180717N013-2



          4 TEST TYPES AND RESULTS

          4.1. CONDUCTED EMISSION MEASUREMENT

          4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT

             FREQUENCY OF EMISSION (MHz)                                 CONDUCTED LIMIT (dBµV)

                                                                  Quasi-peak                              Average
                             0.15 ~ 0.5                             66 to 56                              56 to 46
                              0.5 ~ 5                                 56                                    46
                               5 ~ 30                                 60                                    50
           NOTE: 1.The lower limit shall apply at the transition frequencies.
                 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
                     0.50MHz.
                    3. All emanations from a class A/B digital device or system, including any network of
                       conductors and apparatus connected thereto, shall not exceed the level of field strengths
                       specified above.



          4.1.2 TEST INSTRUMENTS
          Equipment                 Manufacturer      Model No.          Serial No.       Last Cal.           Next Cal.
          EMI Test Receiver        Rohde&Schwarz ESR7                    101494           Mar. 21,18          Mar. 20,19
          Artificial Mains Network Rohde&Schwarz ENV216                  101173           Mar. 03,18          Mar. 02,19
          Artificial Mains Network Rohde&Schwarz ESH3-Z5                 100317           Apr. 11,18          Apr. 10,19
                                   SCHWARZBEC
          Voltage probe                          TK 9421                 TK 9421-176 Jan. 17,18               Jan. 16,19
                                   K
                                                 ADT_Cond_V
          Test software            ADT                                   N/A              N/A                 N/A
                                                 7.3.7
           NOTE:
              1. The test was performed in shielded room 553.
              2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                 traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie                 Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                               Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                      Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 10 of 28                                                       Report Version 1


                         Test Report No.: RF180717N013-2



          4.1.3 TEST PROCEDURES


            a. The EUT was placed 0.4 meters from the conducting wall of the shielded room
               with EUT being connected to the power mains through a line impedance
               stabilization network (LISN). Other support units were connected to the power
               mains through another LISN. The two LISNs provide 50 ohm/ 50uH of coupling
               impedance for the measuring instrument.

            b. Both lines of the power mains connected to the EUT were checked for maximum
               conducted interference.

            c. The frequency range from 150kHz to 30MHz was searched. Emission levels under
               (Limit - 20dB) was not recorded.

           NOTE: All modes of operation were investigated and the worst-case emissions are reported.



          4.1.4 DEVIATION FROM TEST STANDARD


           No deviation.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 11 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2



          4.1.5 TEST SETUP


                                      V e r tic a l G r o u n d
                                      R e f e r e n c e P la n e                                           Te s t R e c e iv e r


                                       EUT
                     40cm




                                                                      80cm
                      L IS N



                                                                                      H o r iz o n ta l G r o u n d
                                                                                       R e f e r e n c e P la n e

                       N o t e : 1 .S u p p o r t u n its w e r e c o n n e c te d t o s e c o n d L IS N .
                                2 .B o t h o f L IS N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t le a s t 8 0
                                    f r o m o th e r u n its a n d o t h e r m e ta l p la n e s



           For the actual test configuration, please refer to the attached file (Test Setup Photo).




          4.1.6 EUT OPERATING CONDITIONS

              a.     Turned on the power and connected of all equipment.
              b.     EUT was operated according to the type used was description in
                     manufacturer’s specifications or the User's Manual.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                                        Guangdong 523942, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 12 of 28                                                      Report Version 1


                         Test Report No.: RF180717N013-2


          4.1.7 TEST RESULTS
           CONDUCTED WORST-CASE DATA:
             PHASE                          Line                                  6dB BANDWIDTH                 9kHz



                                 Corr.        Reading Value          Emission Level                  Limit                  Margin
                     Freq.
              No                Factor          [dB (uV)]              [dB (uV)]                   [dB (uV)]                 (dB)
                     [MHz]
                                 (dB)
                                               Q.P.          AV.       Q.P.       AV.         Q.P.        AV.          Q.P.          AV.
               1    0.60893         10.36      2.61         -4.95     12.97       5.41       56.00       46.00        -43.03       -40.59
               2    0.80772         10.45     10.10         -1.93     20.55       8.52       56.00       46.00        -35.45       -37.48
               3    1.09139         10.23      0.54         -5.48     10.77       4.75       56.00       46.00        -45.23       -41.25
               4    2.91750          9.69      1.34         -4.87     11.03       4.82       56.00       46.00        -44.97       -41.18
               5    4.15950          9.90      4.31         -3.96     14.21       5.94       56.00       46.00        -41.79       -40.06
               6   16.95975          9.94      1.28         -3.91     11.22       6.03       60.00       50.00        -48.78       -43.97


          REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                  2. "-": The Quasi-peak reading value also meets average limit and
                      measurement with the average detector is unnecessary.
                  3. The emission levels of other frequencies were very low against the limit.
                  4. Margin value = Emission level - Limit value
                  5. Correction factor = Insertion loss + Cable loss
                  6. Emission Level = Correction Factor + Reading Value.




                                                   No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                              Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                                            Guangdong 523942, China                     Email: customerservice.dg@cn.bureauveritas.com
                                                                  Page 13 of 28                                                      Report Version 1


                         Test Report No.: RF180717N013-2




             PHASE                      Neutral                          6dB BANDWIDTH               9kHz



                                 Corr.      Reading Value Emission Level                   Limit                  Margin
                     Freq.
              No                Factor        [dB (uV)]     [dB (uV)]                    [dB (uV)]                 (dB)
                     [MHz]
                                 (dB)
                                             Q.P.      AV.       Q.P.       AV.       Q.P.      AV.          Q.P.           AV.
               1    0.17933         10.16   -1.92     -4.63      8.24       5.53     64.52     54.52        -56.28        -48.99
               2    0.79713          9.95    6.18     -3.52     16.13       6.43     56.00     46.00        -39.87        -39.57
               3    1.31100          9.75   -3.52     -6.54      6.23       3.21     56.00     46.00        -49.77        -42.79
               4    3.19650         10.11   -1.04     -5.17      9.07       4.94     56.00     46.00        -46.93        -41.06
               5    4.06500          9.69    2.75     -4.14     12.44       5.55     56.00     46.00        -43.56        -40.45
               6   15.76950          9.81    3.63     -2.59     13.44       7.22     60.00     50.00        -46.56        -42.78

          REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                  2. "-": The Quasi-peak reading value also meets average limit and
                      measurement with the average detector is unnecessary.
                  3. The emission levels of other frequencies were very low against the limit.
                  4. Margin value = Emission level - Limit value
                  5. Correction factor = Insertion loss + Cable loss
                  6. Emission Level = Correction Factor + Reading Value.




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie             Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                           Fax: +86 769 8593 1080
Dongguan Branch
                                                      Guangdong 523942, China                  Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 14 of 28                                                   Report Version 1


                         Test Report No.: RF180717N013-2



          4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT

          4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT

              The field strength of any emissions shall not exceed the following limits:
              (a)15.848mV/m(84dBuV/m) at 30m, within the band 13.553-13.567 MHz;
              (b)334uV/m(50.5dBuV/m) at 30m, within the band 13.410-13.553 MHz and
                13.567-13.710MHz;
              (c)106uV/m(40.5dBuV/m) at 30m, within the band 13.110-13.410 MHz and
                 13.710-14.010MHz;

              The field strength of any emissions appearing outside of the 13.110-14.010 MHz
              band shall not exceed the general radiated emission limits in § 15.209.

                                                 FIELD STRENGTH                  MEASUREMENT DISTANCE
                 FREQUENCIES (MHz)
                                                 (microvolts/meter)                    (meters)

                       0.009 ~ 0.490                 2400/F(kHz)                              300
                       0.490 ~ 1.705                24000/F(kHz)                               30
                        1.705 ~ 30.0                        30                                 30
                           30 ~ 88                         100                                  3
                          88 ~ 216                         150                                  3
                         216 ~ 960                         200                                  3
                         Above 960                         500                                  3
              NOTE:
              1. The lower limit shall apply at the transition frequencies.
              2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
              3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                 average detector, however, the peak field strength of any emission shall not exceed the maximum
                 permitted average limits, specified above by more than 20dB under any condition of modulation.
               4. The measured field strength was extrapolated to distance 30 meters, using the formula that the
                  limit of field strength varies as the inverse distance square (40dB per decade of distance)

                 Example:
                 13.56MHz = 15848uV/m                         30m
                          = 84dBuV/m                          30m
                          = 84+20log(30/3)2                   3m
                               =    124dBuV/m



                                           No. 34, Chenwulu Section, Guantai Rd., Houjie            Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                          Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 15 of 28                                                 Report Version 1


                          Test Report No.: RF180717N013-2



          4.2.2 TEST INSTRUMENTS

           9KHz~30MHz
        Equipment                   Manufacturer       Model No.          Serial No.           Last Cal.            Next Cal.
        EMI Test Receiver   Rohde&Schwarz ESR7                            101564               Jan. 18,18           Jan. 17,19
        Active Loop Antenna SCHWARZBECK FMZB 1519B                        1519B-045            May 04,18            May 03,19
        Amplifier           Burgeon       BPA-530                         100210               Apr. 18,18           Apr. 18,19
                                          ADT_Radiated
        Test Software       ADT                                           N/A                  N/A                  N/A
                                          _V8.7.07
             NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
                         traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                      2. The test was performed in 10m Chamber
                      3. The FCC Site Registration No. is 749762.


          30MHz~1GHz
          Equipment                  Manufacturer             Model No.          Serial No.           Last Cal.          Next Cal.
          EMI Test Receiver          Rohde&Schwarz            ESU40              100449               Mar. 21,18 Mar. 20,19
          Bilog Antenna              Teseq                    CBL 6111D          30643                Aug.11,18          Aug. 10,19
          Amplifier                  Burgeon                  BPA-530            100220               Apr. 18,18 Apr. 18,19
          3m Semi-anechoic
                                     ETS-LINDGREN             9m*6m*6m           NSEMC003             Feb. 10,18 Feb. 09,19
          Chamber
                                                              ADT_Radiated
          Test software              ADT                                   N/A                        N/A                N/A
                                                              _V7.6.15.9.2
          NOTE:
             1. The test was performed in 966 Chamber (a 3m Semi-anechoic chamber).
             2. The calibration interval of the above test instruments are 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
             3. The horn antenna is used only for the measurement of emission frequency above1GHz if tested.
               4. The FCC Site Registration No. is 749762.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie                 Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                               Fax: +86 769 8593 1080
Dongguan Branch
                                                        Guangdong 523942, China                      Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 16 of 28                                                       Report Version 1


                         Test Report No.: RF180717N013-2



          4.2.3 TEST PROCEDURES

          a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a
             3&10 meter semi-anechoic chamber. The table was rotated 360 degrees to
             determine the position of the highest radiation.
          b. The EUT was set 3 meters away from the interference-receiving antenna, which was
             mounted on the top of a variable-height antenna tower.
          c. The antenna is a broadband antenna, and its height is varied from one meter to four
             meters above the ground to determine the maximum value of the field strength. Both
             horizontal and vertical polarizations of the antenna are set to make the
             measurement.
          d. For each suspected emission, the EUT was arranged to its worst case and then the
             antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was
             turned from 0 degrees to 360 degrees to find the maximum reading.
          e. The test-receiver system was set to quasi-peak detect function and specified
             bandwidth with maximum hold mode when the test frequency is below 1 GHz.
          f. During the test, each emission was maximized by: having the EUT continuously
             working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and
             considered typical configuration to obtain worst position, manipulating
             interconnecting cables, For battery operated equipment, the equipment tests shall be
             perform using fresh batteries. The turntable was rotated to maximize the emission
             level.
          g. For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT
             and rotated about its vertical axis for maximum response at each azimuth about the
             EUT. And the centre of the loop shall be 1m above the ground.

          NOTE:
          1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
             Quasi-peak detection at frequency below 1GHz.
          2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and video bandwidth is 3MHz
             for Peak detection at frequency above 1GHz.
          3. All modes of operation were investigated and the worst-case emissions are reported.



          4.2.4 DEVIATION FROM TEST STANDARD

          No deviation.

                                         No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                  Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 17 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2




          4.2.5 TEST SETUP

          Below 30MHz




          30MHz~1GHz

                                                                      Ant. Tower            1-4m
                                                                                            Variable
                                                         3m
                         EUT&
                         Support Units
                                                 Turn Table

                             80cm


                                                     Ground Plane

                                                      Test Receiver




          For the actual test configuration, please refer to the attached file (Test Setup Photo).



                                         No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                  Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 18 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2



          4.2.6 EUT OPERATING CONDITIONS

          Set the EUT under transmission condition continuously at specific channel frequency.

          4.2.7 TEST RESULTS

          FIELD STRENGTH (BELOW 30MHZ AT 3M)
                                    Correction        Raw           Emission
                        Freq.                                                         Polarity       Limit               Margin
             No.                     Factor           Value           Level
                       (MHz)                                                         (0° / 90°)    (dBuV/m)               (dB)
                                     (dB/m)          (dBuV)         (dBuV/m)
              1     *13.56(QP)        23.55           19.19            42.74            0°            124.0               -81.26
              2      27.12(QP)        24.35            8.93            33.28            0°             69.5               -36.22
              3     *13.56(QP)        23.55           15.78            39.33            90°           124.0               -84.67
              4      27.12(QP)        24.35            5.81            30.16            90°            69.5               -39.34

              REMARKS: 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                            2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                            3. The other emission levels were very low against the limit.
                            4. Margin value = Emission level – Limit value.
                            5. " * ": Fundamental frequency.
                            6. For the test results, both 0° and 90° polarizations of the antenna are set to make the
                               measurement, but only the worst case was shown in test report.


                                                                  TEST PLOT
            0°                                                           90°




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                                       Guangdong 523942, China                    Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 19 of 28                                                     Report Version 1


                           Test Report No.: RF180717N013-2




          BELOW 1GHz WORST-CASE DATA:

          CHANNEL                     Channel 1                    DETECTOR
                                                                                                  Quasi-Peak (QP)
          FREQUENCY RANGE             9KHz ~ 1GHz                  FUNCTION


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                                ANTENNA         TABLE             RAW          CORRECTION
                  FREQ.                     LIMIT       MARGIN
          NO.                  LEVEL                                   HEIGHT         ANGLE            VALUE           FACTOR
                  (MHz)                   (dBuV/m)       (dB)
                              (dBuV/m)                                   (m)         (Degree)          (dBuV)           (dB/m)
            1      30.00       18.27 QP     40.00         -21.73        1.00 H             209          29.40             -11.13
            2     351.78       19.26 QP     46.00         -26.74        1.00 H             271          29.86             -10.60
            3     555.42       25.65 QP     46.00         -20.35        1.00 H             344          29.61              -3.96
            4     647.13       25.97 QP     46.00         -20.03        1.00 H             345          29.05              -3.08
            5     734.18       27.01 QP     46.00         -18.99        1.00 H             202          28.58              -1.57
            6     872.53       31.88 QP     46.00         -14.12        1.00 H             342          32.15              -0.27
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                                ANTENNA         TABLE             RAW          CORRECTION
                  FREQ.                     LIMIT       MARGIN
          NO.                  LEVEL                                   HEIGHT         ANGLE            VALUE           FACTOR
                  (MHz)                   (dBuV/m)       (dB)
                              (dBuV/m)                                   (m)         (Degree)          (dBuV)           (dB/m)
            1      30.00       19.39 QP     40.00         -20.61        1.00 V             348          30.52             -11.13
            2     482.36       22.04 QP     46.00         -23.96        1.00 V             119          29.55              -7.51
            3     552.31       25.31 QP     46.00         -20.69        1.00 V             250          29.54              -4.23
            4     634.70       26.70 QP     46.00         -19.30        1.00 V             356          29.77              -3.07
            5     737.29       28.67 QP     46.00         -17.33        1.00 V             103          29.90              -1.23
            6     875.64       32.10 QP     46.00         -13.90        1.00 V             286          32.54              -0.44
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The emission levels of other frequencies were less than 20dB margin against the limit.
                 4. Margin value = Emission level – Limit value.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie                 Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                               Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                      Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 20 of 28                                                       Report Version 1


                         Test Report No.: RF180717N013-2



          4.3. FREQUENCY TOLERANCE
          4.3.1. LIMIT OF FREQUENCY TOLERANCE
           The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of
           the operating frequency over a temperature variation of –20 degrees to 50 degrees C
           at normal supply voltage, and for a variation in the primary supply voltage from 85% to
           115% of the rated supply voltage at a temperature of 20 degrees C.

          4.3.2. TEST INSTRUMENTS

          Equipment                 Manufacturer          Model No.        Serial No.         Last Cal.        Next Cal.
          Power Sensor              Keysight              U2021XA          MY55060016         Jun. 13,18       Jun. 12,19
          Power Sensor              Keysight              U2021XA          MY55060018         Jun. 13,18       Jun. 12,19
          Power Meter               Anritsu               ML2495A          1139001            Apr. 13,18       Apr. 13,19
          Power Sensor              Anritsu               MA2411B          1531155            Apr. 13,18       Apr. 13,19
          Digital Multimeter        FLUKE                 15B              A1220010DG         Oct. 21, 18 Oct.20, 19
          Humid & Temp
                                    Haida                 HD-2257          110807201          Sep.05,18        Sep. 04,19
          Programmable Tester
          Oscilloscope              Agilent         DSO9254A               MY51260160         Nov. 08,17       Nov. 07,18
          Signal Analyzer           Rohde & Schwarz FSV7                   102331             Nov. 04,17       Nov. 03,18
          Signal Generator          Agilent               N5183A             MY50140980 Jan. 02,18             Jan. 01,19
          Agile Signal
                                    Agilent               8645A            Agilent            Sep.01, 18 Aug.31, 19
          Generator
          Spectrum Analyzer         Keysight              N9020A           MY55400499         Mar. 21,18       Mar. 20,19
          MXG-B RF Vector
                                    Keysight              N5182B           MY56200288         Jan. 02,18       Jan. 01,19
          Signal Generator
          BLUETOOTH
                                    Rohde&Schwarz CBT32                    100811             Jul.06, 18       Jul. 05, 19
          TESTER
          Attenuator                MINI                  BW-S10W2+ S130129FGE2 N/A                            N/A
          DC Source                 Keysight              E3642A           MY56146098         N/A              N/A
          NOTE:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                                       Guangdong 523942, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 21 of 28                                                    Report Version 1


                         Test Report No.: RF180717N013-2




          4.3.3. TEST PROCEDURES

          a) The EUT was placed inside the environmental test chamber and powered by
             nominal DC voltage.
          b) Turn the EUT on and couple its output to a spectrum analyzer.
          c) Turn the EUT off and set the chamber to the highest temperature specified.
          d) Allow sufficient time (approximately 30 min) for the temperature of the chamber to
             stabilize, turn the EUT on and measure the operating frequency after 2, 5, and 10
             minutes.
          e) Repeat step c) and d) with the temperature chamber set to the lowest temperature.
          f)   The test chamber was allowed to stabilize at +20 degree C for a minimum of 30
               minutes. The supply voltage was then adjusted on the EUT from 85% to 115% and
               the frequency record.

          4.3.4. DEVIATION FROM TEST STANDARD

          No deviation.


          4.3.5. TEST SETUP


                                          Temperature


                  Spectrum Analyzer




                                    DC Power Supply




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                        Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 22 of 28                                                 Report Version 1


                          Test Report No.: RF180717N013-2



          4.3.6. EUT OPERATING CONDITIONS


          Set the EUT under transmission condition continuously at specific channel frequency.

          4.3.7. TEST RESULTS

                                               FREQUEMCY STABILITY VERSUS TEMP.

                                    0 MINUTE                2 MINUTE                 5 MINUTE                       10 MINUTE

        TEMP. POWER Measured Frequency Measured Frequency Measured Frequency Measured Frequency
              SUPPLY
          ℃)
         (℃          Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
                (V)

                              (MHz)            %       (MHz)           %         (MHz)            %            (MHz)              %

          50     DC3.7V     13.56002     0.00015      13.56002     0.00015      13.56002       0.00015       13.56002         0.00015

          40     DC3.7V     13.55996     -0.00029     13.55996     -0.00029     13.55996       -0.00029      13.55996         -0.00029

          30     DC3.7V     13.55998     -0.00015     13.55997     -0.00022     13.55997       -0.00022      13.55997         -0.00022

          20     DC3.7V     13.56006     0.00044      13.56007     0.00052      13.56005       0.00037       13.56006         0.00044

          10     DC3.7V     13.56003     0.00022      13.56003     0.00022      13.56003       0.00022       13.56003         0.00022

           0     DC3.7V     13.56002     0.00015      13.56002     0.00015      13.56002       0.00015       13.56002         0.00015

          -10    DC3.7V     13.56005     0.00037      13.56006     0.00044      13.56006       0.00044       13.56005         0.00037

          -20    DC3.7V     13.56001     0.00007      13.56001     0.00007      13.56001       0.00007       13.56001         0.00007



                                           FREQUEMCY STABILITY VERSUS VOLTAGE

                                    0 MINUTE                2 MINUTE                 5 MINUTE                       10 MINUTE

        TEMP. POWER Measured Frequency Measured Frequency Measured Frequency Measured Frequency
              SUPPLY
          ℃)
         (℃          Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
                (V)

                              (MHz)            %       (MHz)           %         (MHz)            %            (MHz)              %

          20     DC3.7V     13.56006     0.00044      13.56007     0.00052      13.56005       0.00037       13.56006         0.00044




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie                  Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch
                                                        Guangdong 523942, China                       Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 23 of 28                                                        Report Version 1


                         Test Report No.: RF180717N013-2



          4.4. 20dB BANDWIDTH


          4.4.1 LIMITS OF 20dB BANDWIDTH

           The 20dB bandwidth shall be specified in operating frequency band.(13.11MHz –
             14.01MHz)

          4.4.2 TEST INSTRUMENTS

          Equipment                 Manufacturer          Model No.        Serial No.         Last Cal.        Next Cal.
          Power Sensor              Keysight              U2021XA          MY55060016         Jun. 13,18       Jun. 12,19
          Power Sensor              Keysight              U2021XA          MY55060018         Jun. 13,18       Jun. 12,19
          Power Meter               Anritsu               ML2495A          1139001            Apr. 13,18       Apr. 13,19
          Power Sensor              Anritsu               MA2411B          1531155            Apr. 13,18       Apr. 13,19
          Digital Multimeter        FLUKE                 15B              A1220010DG         Oct. 21, 18 Oct.20, 19
          Humid & Temp
                                    Haida                 HD-2257          110807201          Sep.05,18        Sep. 04,19
          Programmable Tester
          Oscilloscope              Agilent         DSO9254A               MY51260160         Nov. 08,17       Nov. 07,18
          Signal Analyzer           Rohde & Schwarz FSV7                   102331             Nov. 04,17       Nov. 03,18
          Signal Generator          Agilent               N5183A             MY50140980 Jan. 02,18             Jan. 01,19
          Agile Signal
                                    Agilent               8645A            Agilent            Sep.01, 18 Aug.31, 19
          Generator
          Spectrum Analyzer         Keysight              N9020A           MY55400499         Mar. 21,18       Mar. 20,19
          MXG-B RF Vector
                                    Keysight              N5182B           MY56200288         Jan. 02,18       Jan. 01,19
          Signal Generator
          BLUETOOTH
                                    Rohde&Schwarz CBT32                    100811             Jul.06, 18       Jul. 05, 19
          TESTER
          Attenuator                MINI                  BW-S10W2+ S130129FGE2 N/A                            N/A
          DC Source                 Keysight              E3642A           MY56146098         N/A              N/A
          NOTE:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                                       Guangdong 523942, China                   Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 24 of 28                                                    Report Version 1


                         Test Report No.: RF180717N013-2



          4.4.3 TEST PROCEDURE
            a. Check the calibration of the measuring instrument using either an internal calibrator
               or a known signal from an external generator.
            b. Turn on the EUT and connect it to measurement instrument. Then set it to any one
               convenient frequency within its operating range. Set a reference level on the
               measuring instrument equal to the highest peak value.
            c. Measure the frequency difference of two frequencies that were attenuated 20dB
               from the reference level. Record the frequency difference as the emission
               bandwidth.
            d. Repeat above procedures until all frequencies measured were complete.




          4.4.4 DEVIATION FROM TEST STANDARD

          No deviation.



          4.4.5 TEST SETUP


                          EUT                                               SPECTRUM

                                                 10dB ATTENUATION           ANALYZER
                                                 PAD




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 25 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2




          4.4.6 EUT OPERATING CONDITION

             The software provided by client to enable the EUT under transmission condition
             continuously at one channel frequencies individually.




          4.4.7 TEST RESULTS


                    CHANNEL           CHANNEL FREQUENCY (MHz)                       20dB BANDWIDTH (KHz)

                         1                           13.56                                   29.81


                   Lower & Upper Test Frequency Point               Test Frequency
                                                                                                     P/F
                                 (MHz)                                   (MHz)
                                    Lower                                13.54509                  PASS
                                    Upper                                13.57491                  PASS




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 26 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2



           5.    PHOTOGRAPHS OF THE TEST CONFIGURATION

          Please refer to the attached file (Test Setup Photo).




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 27 of 28                                                 Report Version 1


                         Test Report No.: RF180717N013-2



          6. APPENDIX A - MODIFICATIONS RECORDERS FOR
          ENGINEERING CHANGES TO THE EUT BY THE LAB


           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie           Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                         Fax: +86 769 8593 1080
Dongguan Branch
                                                 Guangdong 523942, China                Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 28 of 28                                                 Report Version 1



Document Created: 2018-12-07 19:07:11
Document Modified: 2018-12-07 19:07:11

© 2024 FCC.report