Test Report

FCC ID: 2AEJW-SRRPBT

Test Report

Download: PDF
FCCID_2804749

              R


                                                AUDIX Technology (Shenzhen) Co., Ltd.

FCC ID:2AEJW-SRRPBT




                  FCC PART 15C TEST REPORT FOR CERTIFICATION
                                   On Behalf of

                        Shenzhen Aodelan Technology Co., ltd.

                       Wireless Remote Shutter Release Transmitter

                                     SRR-PEBBLE(T)

                                FCC ID: 2AEJW-SRRPBT




                           Prepared for : Shenzhen Aodelan Technology Co., ltd.
                                          Room 501, Block A, Guoren Building, Keji Central 3rd
                                          Road, Hi-Tech Park, Nanshan District, Shenzhen,
                                          Guangdong, China




                           Prepared By : Audix Technology (Shenzhen) Co., Ltd.
                                         No. 6, Ke Feng Rd., 52 Block,
                                         Shenzhen Science & Industrial Park,
                                         Nantou, Shenzhen, Guangdong, China

                                         Tel: (0755) 26639496




                           Report Number :      ACS-F15284
                           Date of Test   :     Oct.10~12, 2015
                           Date of Report :     Oct.27, 2015




                                                  Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


                R


                                                                                   AUDIX Technology (Shenzhen) Co., Ltd.

FCC ID:2AEJW-SRRPBT



                                             TABLE OF CONTENTS

    Description                                                                                                                                         Page

   1.    SUMMARY OF STANDARDS AND RESULTS.......................................................... 1-1
         1.1.       Description of Standards and Results .................................................................................. 1-1
   2.    GENERAL INFORMATION ......................................................................................... 2-1
         2.1.       Description of Device (EUT) ............................................................................................... 2-1
         2.2.       EUT Configuration and operation conditions for test. ......................................................... 2-1
         2.3.       Test Facility ......................................................................................................................... 2-2
         2.4.       Measurement Uncertainty (95% confidence levels, k=2) .................................................... 2-2
   3.    POWER LINE CONDUCTED EMISSION TEST ....................................................... 3-1
   4.    RADIATED EMISSION TEST ...................................................................................... 4-1
         4.1.       Test Equipment .................................................................................................................... 4-1
         4.2.       Block Diagram of Test Setup ............................................................................................... 4-2
         4.3.       Radiated Emission Limit Standard: FCC 15.209 and 15.249 .............................................. 4-3
         4.4.       EUT Configuration on Test.................................................................................................. 4-3
         4.5.       Operating Condition of EUT................................................................................................ 4-3
         4.6.       Test Procedure...................................................................................................................... 4-4
         4.7.       Radiated Emission Test Results ........................................................................................... 4-4
   5.    20 DB BANDWIDTH TEST ........................................................................................... 5-1
         5.1.       Test Equipment .................................................................................................................... 5-1
         5.2.       Limit ..................................................................................................................................... 5-1
         5.3.       Test Results .......................................................................................................................... 5-1
   6.    BAND EDGE COMPLIANCE TEST ............................................................................ 6-1
         6.1.       Test Equipment .................................................................................................................... 6-1
         6.2.       Limit ..................................................................................................................................... 6-1
         6.3.       Test Produce ......................................................................................................................... 6-1
         6.4.       Test Results .......................................................................................................................... 6-1
   7.    ANTENNA REQUIREMENT ........................................................................................ 7-1
   8.    RADIO FRREQUENCY EXPOSURE COMPLIANCE .............................................. 8-1
   9.    DEVIATION TO TEST SPECIFICATIONS................................................................ 9-1
   10.   PHOTOGRAPH OF TEST ........................................................................................... 10-1
         10.1. Photos of Radiated Emission Test...................................................................................... 10-1
   11.   PHOTOGRAPH OF EUT ............................................................................................. 11-1




                                                                                       Audix Technology (Shenzhen) Co., Ltd.              Report No. ACS-F15284




              R


                                                      AUDIX Technology (Shenzhen) Co., Ltd.

FCC ID:2AEJW-SRRPBT                                                                               page     1-1




       1. SUMMARY OF STANDARDS AND RESULTS
           1.1.Description of Standards and Results
                  The EUT have been tested according to the applicable standards as referenced below.
                                                EMISSION
               Description of Test Item                      Standard                           Results
                                                       FCC Part 15C: 15.207
         Power Line Conducted Emission Test                                                      N/A
                                                        ANSI C63.10-2013
                                                       FCC Part 15C: 15.209
                  Radiated Emission Test               FCC Part 15C: 15.249                     PASS
                                                        ANSI C63.10-2013
                                                        FCC Part 15: 15.249
             Band Edge Compliance Test                                                          PASS
                                                        ANSI C63.10-2013
                                                        FCC Part 15: 15.215
                   20dB Bandwidth Test                                                          PASS
                                                        ANSI C63.10-2013

        N/A is an abbreviation for Not Applicable.




                                                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                AUDIX Technology (Shenzhen) Co., Ltd.

FCC ID:2AEJW-SRRPBT                                                                         page     2-1




       2. GENERAL INFORMATION
           2.1.Description of Device (EUT)
                  Product Name      : Wireless Remote Shutter Release Transmitter

                  Model Number      : SRR-PEBBLE(T)

                  FCC ID            : 2AEJW-SRRPBT

                  Operation frequency : 2405MHz (Tx)

                  Antenna           : Internal PCB Antenna, 3dBi gain

                  Modulation        : GFSK

                  Applicant         : Shenzhen Aodelan Technology Co., ltd.
                                      Room 501, Block A, Guoren Building, Keji Central 3rd
                                      Road, Hi-Tech Park, Nanshan District, Shenzhen,
                                      Guangdong, China

                  Manufacturer      : Shenzhen Fudasi Technology Co., Ltd.
                                      B Building, Shengde Industrial Park, Dalang Longhua
                                      Town, Baoan District Shenzhen City, 518109 China

                  Factory           : Shenzhen Fudasi Technology Co., Ltd.
                                      B Building, Shengde Industrial Park, Dalang Longhua
                                      Town, Baoan District Shenzhen City, 518109 China

                  Date of Test      : Oct.10~12, 2015

                  Date of Receipt   : Oct.08, 2015

                  Sample Type       : Prototype production




          2.2.EUT Configuration and operation conditions for test.

                                    EUT


              ( EUT: Wireless Remote Shutter Release Transmitter)




                                                  Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                    AUDIX Technology (Shenzhen) Co., Ltd.

FCC ID:2AEJW-SRRPBT                                                                               page     2-2



         2.3.Test Facility
             Site Description
                                                   Audix Technology (Shenzhen) Co., Ltd.
                                                   No. 6, Ke Feng Rd., 52 Block, Shenzhen
             Name of Firm                      :   Science & Industrial Park,Nantou, Shenzhen,
                                                   Guangdong, China

                                                   Certificated by FCC, USA
             3m Anechoic Chamber               :   Registration Number: 90454
                                                   Valid Date: Dec.30, 2017

                                                   Certificated by FCC, USA
             3m & 10m Anechoic Chamber         :   Registration Number: 794232
                                                   Valid Date: Jul.12, 2016

                                                   Certificated by Industry Canada
             EMC Lab.                          :   Registration Number: IC 5183A-1
                                                   Valid Date: May.14, 2017

                                                   Certificated by DAkkS, Germany
                                               :   Registration No: D-PL-12151-01-00
                                                   Valid Date: Dec.15, 2016

                                                   Accredited by NVLAP, USA
                                               :   NVLAP Code: 200372-0
                                                   Valid Date: Mar.31, 2016
         2.4.Measurement Uncertainty (95% confidence levels, k=2)
                                Test Item                                 Uncertainty
                                                             3.0 dB(30~200MHz, Polarization: H)
              Uncertainty for Radiation Emission test        3.0 dB(30~200MHz, Polarization: V)
                          in 3m chamber                      3.2 dB(200M~1GHz, Polarization: H)
                                                             3.1 dB(200M~1GHz, Polarization: V)
             Uncertainty for Radiation Emission test in         6.3 dB (1~6GHz, Distance: 3m)
                   3m chamber (1GHz-18GHz)                     5.7 dB (6~18GHz, Distance: 3m)
                Uncertainty for Radiated Spurious
                                                                                  3.6 dB
                   Emission test in RF chamber
               Uncertainty for Conduction Spurious
                                                                                  2.0 dB
                           emission test
                Uncertainty for Output power test                                0.8 dB
                  Uncertainty for Bandwidth test                                 83 kHz
                  Uncertainty for DC power test                                   0.1 %
              Uncertainty for test site temperature and                           0.6℃
                              humidity                                             3%




                                                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                   AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                     page            3-1


       3. POWER LINE CONDUCTED EMISSION TEST
           According to Paragraph (c) of FCC Part 15 section 15.207, Tests to demonstrate
           compliance with the conducted limits are not required for devices which only employ
           battery power for operation and which do not operate from the AC power lines or contain
           provisions for operation while connected to the AC power lines.




                                                     Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                               AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                page            4-1




       4. RADIATED EMISSION TEST
           4.1.Test Equipment
               Frequency range: 30~1000MHz
Item     Equipment         Manufacturer  Model No.    Serial No.              Last Cal. Cal. Interval
 1.     3#Chamber            AUDIX          N/A         N/A                   Nov.23,14   1 Year
 2.   EMI Spectrum           Agilent       E4407B   MY41440292                Apr.28,15   1 Year
 3.    Test Receiver    Rohde & Schwarz ESVS10       834468/011               Apr.28,15   1 Year
 4.      Amplifier              HP         8447D     2648A04738               Apr.28,15   1 Year
     Trilog-Broadband
 5.                     SCHWARZBECK VULB 9168         9168-493               May.06,15           1 Year
          Antenna
                                         CFD400-N
 6.      RF Cable          MIYAZAKI                     No.3                  Apr.28,15          1 Year
                                          W(3.5M)
                                         CFD400-L
 7.      RF Cable          MIYAZAKI                     No.7                  Apr.28,15          1 Year
                                           W(22M)
 8.   Coaxial Switch         Anritsu       MP59B     6201397222               Apr.28,15          1 Year
 9.    Test Software         AUDIX           E3    6.2009-5-21a(n)              N/A               N/A

              Frequency range: above 1000MHz
                                                                                                  Cal.
Item       Equipment       Manufacturer   Model No.         Serial No.          Last Cal.
                                                                                                Interval
 1.       3#Chamber          AUDIX           N/A        N/A                    Nov.02,14         1 Year
 2.    Spectrum Analyzer     Agilent       E4407B   MY41440292                 Apr.28,15         1 Year
 3.      Horn Antenna         ETC         MCTD 1209DRH15F03006                 Feb.03,15         1 Year
 4.        Amplifier         Agilent       83017A   MY53270084                 May.25,15         1 Year
                                                   505238/6+2861
 5.        RF Cable        Hubersuhner SUCOFLEX106                             Apr.28,15         1 Year
                                                         6/2
 6.      Test Software       AUDIX          E3     6.2009-5-21a(n)               N/A              N/A
 7.      Horn Antenna         ETS          3116       00060088                 Nov.08.14         1 Year




                                                Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                          page            4-2



           4.2.Block Diagram of Test Setup
              For frequency range 30MHz-1000MHz


                                                 Semi-anechoic 3m Chamber

                             ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                                3m


                                                                EUT



                                                                      TURN TABLE
                              2.0m(L)*1.0m(W)*0.8m(H)                (FIBRE GLASS)




        Combining Network      AMP        Spectrum                      PC System
                                          AnalABSORBER

              Receiver


              For frequency range above 1GHz


                                         Semi-anechoic 3m Chamber
                             ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                            Remark: If necessary, The antenna rise and fall from 1 to 4 meters.



                                            3m                   EUT
                                      (Reference Point)


                               2.0m(L)*1.0m(W)*1.5m(H)                 TURN TABLE
                                                                                                  1.5m
                                    ABSORBER                             (Styrene)
                                    (30cm maximum)

                                                          (30cm)

                               AMP         Spectrum Analyzer            PC System




                                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                      page            4-3



           4.3. Radiated Emission Limit Standard: FCC 15.209 and 15.249
                         FREQUENCY                 DISTANCE               FIELD STRENGTHS LIMIT
                            MHz                      Meters                  μV/m         dB(μV)/m
                         30 ~ 88                       3                      100            40.0
                         88 ~ 216                      3                      150            43.5
                        216 ~ 960                      3                      200            46.0
                        960 ~ 1000                     3                      500            54.0
                       Above 1000MHz                   3                     74.0 dB(μV)/m (Peak)
                                                                           54.0 dB(μV)/m (Average)
                      Field Strength of
                                                                                 114.0 dB(μV)/m (Peak)
                  fundamental emissions for             3
                                                                                94.0 dB(μV)/m (Average)
                  2.4GHz-2.4835GHz

                  Remark: (1) Emission level dBμV = 20 log Emission level μV/m
                          (2) The smaller limit shall apply at the cross point between two frequency
                              bands.
                          (3) Distance is the distance in meters between the measuring instrument,
                              antenna and the closest point of any part of the device or system.
                          (4) The emission limits shown in the above table are based on
                               measurements employing a CISPR quasi-peak detector except for the
                               frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz.
                               Radiated emission limits in these three bands are based on
                               measurements employing an average detector.
            4.4.EUT Configuration on Test
                  The following equipment are installed on Radiated Emission Test to meet the
                  commission requirements and operating regulations in a manner which tends to
                  maximize its emission characteristics in normal application.
            4.5.Operating Condition of EUT
                  4.5.1.Setup the EUT and simulator as shown as Section 4.2.
                  4.5.2.Turn on the power of all equipments.
                  4.5.3.Let EUT work in Tx mode.




                                                      Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                       page            4-4



            4.6.Test Procedure
                  EUT and its simulators are placed on a turn table, which is 0.8 meter high above
                  ground for frequency 30MHz~1000MHz, 1.5 meter high above ground for frequency
                  above 1GHz and put the absorbing with 2.4m(L)*2.4m(W)*0.3m(H) on the ground .
                  The turn table can rotate 360 degrees to determine the position of the maximum
                  emission level. Power on the EUT and let it working in test mode, then test it.EUT is
                  set 3 meters away from the receiving antenna, which is mounted on a antenna tower.
                  The antenna can be moved up and down between 1 meter and 4 meters to find out the
                  maximum emission level. Broadband antenna (calibrated bilog antenna) is used as
                  receiving antenna for frequency 30MHz~1000MHz, and the Horm antenna is used as
                  receiving antenna for frequency above 1GHz. Both horizontal and vertical
                  polarization of the antenna is set on Test. In order to find the maximum emission
                  levels, all of the interface cables must be manipulated according to ANSI
                  C63.10-2013 on radiated emission Test.

                  This test was performed with EUT in X, Y, Z position, and the worse case was found
                  when EUT in X position as the test photo indicated.

                  The bandwidth of the EMI test receiver (R&S ESVS10) is set at 120kHz for
                  frequency range from 30MHz to 1000 MHz.

                  The bandwidth of the Spectrum’s RBW is set at 1MHz and VBW is set at 3MHz for
                  peak emissions measurement above 1GHz

                  This device is pulse modulated, a duty cycle factor was used to calculate average
                  level based measured peak level.

                  The frequency range from 30MHz to 10th harmonic (25GHz) are checked. and no any
                  emissions were found from 18GHz to 25 GHz, So the radiated emissions from 18GHz
                  to 25GHz were not record.
            4.7.Radiated Emission Test Results
                  PASS.
                  All the emissions from 30MHz to 25GHz were comply with the 15.209 Limit.

                  Note: The duty cycle factor for calculate average level is 28.80 dB, and average limit
                        is 20dB below peak limit, so if peak measured level comply with average limit,
                        the average level was deemed to comply with average limit.




                                                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                 AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                   page            4-5



        Duty cycle factor = 20log(1/duty cycle)= 28.80




                                                   Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            4-6




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                         page            4-7



Frequency: 30MHz~1GHz




                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            4-8




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                         page            4-9



Frequency: 1GHz~18GHz




                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


               R


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                          page          4-10




         Frequency    Peak level   Duty cycle factor    AV level         Limit
                                                                                        Conclusion
           (MHz)      (dBuv/m)            (dB)         (dBuv/m)        (dBuv/m)
          7215         58.03            28.80           29.23              54              Pass




                                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page          4-11




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


               R


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                          page          4-12




         Frequency    Peak level   Duty cycle factor    AV level         Limit
                                                                                        Conclusion
           (MHz)      (dBuv/m)            (dB)         (dBuv/m)        (dBuv/m)
          4810         56.04            28.80           27.24              54              Pass
          7215         61.08            28.80           32.28              54              Pass




                                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


               R


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                          page            5-1




      5.     20 DB BANDWIDTH TEST
      5.1. Test Equipment
                                                                                                            Cal.
       Item    Equipment      Manufacturer       Model No.             Serial No.          Last Cal.
                                                                                                          Interval
       1.       Spectrum         Agilent          N9030A            MY51380221            Oct.29, 14       1Year
                Attenuator
       2.                        Agilent              8491B         MY39262165            Apr.28,15        1 Year
                 (20dB)
       3.       RF Cable      Hubersuhner     SUCOFLEX102               28620/2          Apr. 28,15        1 Year

      5.2. Limit
             Intentional radiators operating under the alternative provisions to the general emission
             limits, as contained in §§ 15.217 through 15.257 and in Subpart E of this part, must be
             designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may
             otherwise be specified in the specific rule section under which the equipment operates, is
             contained within the frequency band designated in the rule section under which the
             equipment is operated.

      5.3. Test Results
     EUT: Wireless Remote Shutter Release Transmitter
     M/N: SRR-PEBBLE(T)
     Test date: 2015-10-12          Pressure: 101.2±1.0 kpa                   Humidity: 53.8±3.0%
     Tested by: Leo-Li              Test site: RF Site                        Temperature:23.5±0.6℃


            Frequency                  20dB Bandwidth                                    Limit
              (MHz)                        (MHz)                                        (MHz)
             2405                            0.8476                                      N/A
     Conclusion:PASS




                                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            5-2




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                        page            6-1




         6. BAND EDGE COMPLIANCE TEST
           6.1. Test Equipment
    Item     Equipment      Manufacturer      Model No.       Serial No.          Last Cal. Cal. Interval
    1.       Spectrum         Agilent          E4446A        US44300459           Apr.28,15   1 Year
    2.         Amp              HP              8449B        3008A02495           Apr.28,15   1 Year
               Horn
    3.                           ETC         MCTD 1209 DRH15F03007 Feb.03,15                          1 Year
              Antenna
    4.       HF Cable        Hubersuhner     Sucoflex104        274094/4          Apr.28,15           1 Year
           6.2. Limit
                  All the lower and upper band-edges emissions appearing within 2310MHz to
                  2390MHz and 2483.5MHz to 2500MHz restricted frequency bands shall not exceed
                  the limits shown in 15.209, all the other emissions outside operation frequency band
                  2400MHz to 2483.5MHz shall be at least 20dB below the fundamental emissions, or
                  comply with 15.209 limits.
           6.3. Test Produce
                  1.  The EUT is placed on a turntable, which is 1.5m above the ground plane and
                     worked at highest radiated power.
                  2. The turntable was rotated for 360 degrees to determine the position of maximum
                     emission level.
                  3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m
                     to find out the highest emission.
                  4. Set the spectrum analyzer in the following setting in order to capture the lower
                     and upperband-edges of the emission:
                    (a) PEAK: RBW=1MHz ;VBW=3MHz, PK detector, Sweep=AUTO
                    (b)This device is pulse modulated, a duty cycle factor was used to calculate
                         average level based measured peak level
           6.4. Test Results
                  Pass (The testing data was attached in the next pages.)

                  Note: If the PK measured levels comply with average limit, then the average level
                  were deemed to comply with average limit.

                  Note: The duty cycle factor for calculate average level is 28.80 dB, and average limit
                        is 20dB below peak limit, so if peak measured level comply with average limit,
                        the average level was deemed to comply with average limit.




                                                        Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            6-2




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            6-3




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            6-4




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                       page            6-5




                       Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                          page            7-1



  7. ANTENNA REQUIREMENT
      RESULT           :       PASS

      Test Date       :        Oct.10~12, 2015

      Test standard    :       FCC Part 15.203

      Limit                :   the use of antennas with directional gains that do not exceed 6 dBi


      According to the manufacturer declared, the EUT has an internal antenna, the directional gain
      of antenna is 3dBi, and the antenna connector is designed with permanent attachment and no
      consideration of replacement. Therefore the EUT is considered sufficient to comply the
      provision.




                                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


              R


                                                AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                                                  page            8-1



  8. RADIO FRREQUENCY EXPOSURE COMPLIANCE
      RESULT          :   PASS

      Test standard   :   FCC KDB Publication 447498 D01 V05

      Since maximum peak output power of the transmitter is<10mW, i.e.0.009346mW<10mW, hence
      the EUT is excluded from SAR evaluation according to FCC KDB Publication 447498
      D01:General RF Exposure Guidance V05.




                                                  Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284


               R


                            AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:2AEJW-SRRPBT                                             page            9-1



  9. DEVIATION TO TEST SPECIFICATIONS
      [NONE]




                             Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F15284



Document Created: 2015-10-28 18:42:26
Document Modified: 2015-10-28 18:42:26

© 2024 FCC.report