tune up procedure

FCC ID: 2AE6H-ACCM

Parts List/Tune Up Info

Download: PDF
FCCID_4297370

Applicant: Amotech Corp.                                           FCC ID:2AE6H-ACCM



TUNE-UP PROCEDURE


There are no user accessible adjustments or tuning in this device.
All necessary adjustments and tuning are performed during manufacture of the
product. Any adjustments or tuning after service or repair are done as part of that
process as special equipment is required to perform such adjustments.


Target Power & Tolerance



LTE
                                                                 Modulated Average
                             Band & Mode
                                                                      [dBm]
                                                 Maximum               20.0
             LTE Band 12
                                                 Nominal               19.0
                                                 Maximum               22.0
             LTE Band 4
                                                 Nominal               21.0
                                                 Maximum               21.0
             LTE Band 2
                                                 Nominal               20.0
Nominal Power Tolerance: (+1.0 dB~ -1.0 dB)



MPR condition

    RB Size                Mod             MPR

       1                   QPSK             0

      50%                  QPSK             1

      100%                 QPSK             1

       1                  16-QAM            1

      50%                 16-QAM            2

      100%                16-QAM            2

* MPR Tolerance: +0.5dB/-0.5dB



Document Created: 2019-05-13 15:12:41