Test Report

FCC ID: 2AE6GUHF-6100-R2

Test Report

Download: PDF
FCCID_4105850

                                       Page 1 of 25                    Report No.: HK1811141565E




                                    TEST REPORT
                               FCC PART 15 SUBPART B




                                     Test report
                                    On Behalf of
                        Innovative Concepts and Design LLC
                                        For
                                 Wireless Receiver

                                  Model No.: UHF-6100

                             FCC ID: 2AE6GUHF-6100-R2




 Prepared for :   Innovative Concepts and Design LLC
                  107 Trumbull Street, Bldg F8, Elizabeth, New Jersey, 07206-2165 United States




Prepared By :     Shenzhen HUAK Testing Technology Co., Ltd.
                  1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping
                  Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China




Date of Test:     Nov. 28, 2018 ~ Dec. 05, 2018
Date of Report:   Dec. 05, 2018
Report Number:    HK1811141565E


                                                                   Page 2 of 25                      Report No.: HK1811141565E



                                                    TEST RESULT CERTIFICATION

Applicant’s name .................... : Innovative Concepts and Design LLC

                                                   107 Trumbull Street, Bldg F8, Elizabeth, New Jersey, 07206-2165
Address ..................................... :
                                                   United States
Manufacture's Name ............... : PROAUDIO ELECTRONICS CO., LIMITED

                                                   FLAT 03H 15/F CARNIVAL COMMERCIAL BUILDING 18 JAVA
Address ..................................... :
                                                   ROAD NORTH POINT HK
Product description

Trade Mark:                                        Gemini
Product name............................ : Wireless Receiver
Model and/or type reference ... : UHF-6100

Standards................................. : 47 CFR FCC Part 15 Subpart B 15.107&15.109
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
Date of Test ................................................:
Date (s) of performance of tests .................:                  Nov. 28, 2018 ~ Dec. 05, 2018
Date of Issue ...............................................:       Dec. 05, 2018
Test Result ...................................................:     Pass



                           Testing Engineer                    :


                                                                                  (Gary Qian)

                           Technical Manager                   :

                                                                                   (Eden Hu)


                           Authorized Signatory                :


                                                                                  (Jason Zhou)


                                                                     Page 3 of 25                                         Report No.: HK1811141565E



                                                                TABLE OF CONTENTS

1.SUMMARY ......................................................................................................................................................... 4

   1.1 TEST STANDARDS .................................................................................................................................... 4
   1.2 TEST DESCRIPTION .................................................................................................................................. 4
   1.3 TEST FACILITY ........................................................................................................................................... 4
   1.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY .......................................................................... 5

2.GENERAL INFORMATION................................................................................................................................ 6

   2.1 ENVIRONMENTAL CONDITIONS.............................................................................................................. 6
   2.2 GENERAL DESCRIPTION OF EUT ............................................................................................................ 6
   2.3. DESCRIPTION OF TEST MODES ............................................................................................................. 6
   2.4. RELATED SUBMITTAL(S) / GRANT (S) .................................................................................................... 6
   2.5. TEST METHODOLOGY ............................................................................................................................. 6
   2.6. ACCESSORIES USED............................................................................................................................... 6
   2.7 EQUIPMENT USED .................................................................................................................................... 7

3. RADIATED EMISSION ..................................................................................................................................... 8

   3.1. MEASUREMENT PROCEDURE ............................................................................................................... 8
   3.2. TEST SETUP............................................................................................................................................ 10
   3.3. TEST RESULT.......................................................................................................................................... 11

4. FCC LINE CONDUCTED EMISSION TEST .................................................................................................. 13

   4.1. LIMITS OF LINE CONDUCTED EMISSION TEST .................................................................................. 13
   4.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST ................................................................ 13
   4.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST ............................................. 14
   4.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST ............................................................ 14
   4.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST ...................................................................... 15

APPENDIX A: PHOTOGRAPHS OF TEST SETUP .......................................................................................... 17

APPENDIX B: PHOTOGRAPHS OF EUT ......................................................................................................... 19


                                                 Page 4 of 25                          Report No.: HK1811141565E



1.SUMMARY
1.1 TEST STANDARDS

This submittal(s) (test report) is intended to comply with Section 15.107&109 of the FCC Part 15, Subpart B
Rules.


1.2 TEST DESCRIPTION


       FCC RULES                             DESCRIPTION OF TEST                                RESULT

          §15.109                                Radiated Emission                              Compliant
          §15.107                               Conducted Emission                              Compliant




1.3 TEST FACILITY

1.3.1 Address of the test laboratory
Shenzhen HUAK Testing Technology Co., Ltd.
Add.:1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park,Heping Community, Fuhai Street, Bao'an
District, Shenzhen, China

There is one 3m semi-anechoic chamber and two line conducted labs for final test. The Test Sites meet the
requirements in documents ANSI C63.4 and CISPR 32/EN 55032 requirements.

1.3.2 Laboratory accreditation
The test facility is recognized, certified, or accredited by the following organizations:

IC Registration No.: 21210

The 3m alternate test site of Shenzhen HUAK Testing Technology Co., Ltd. EMC Laboratory has been
registered by Certification and Engineer Bureau of Industry Canada for the performance of with Registration
No.: 21210 on May 24, 2016.


FCC Registration No.: CN1229
Test Firm Registration Number : 616276


                                               Page 5 of 25                       Report No.: HK1811141565E




1.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY

The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 “Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC Measurements“ and
is documented in the Shenzhen HUAK Testing Technology Co., Ltd. quality system acc. to DIN EN ISO/IEC
17025. Furthermore, component and process variability of devices similar to that tested may result in additional
deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Hereafter the best measurement capability for HUAK laboratory is reported:
                                                                   Measurement
Test                                                                                               Notes
                                                                   Uncertainty
Radiated Emission 30~1000MHz                                       ±4.10dB                         (1)
Radiated Emission Above 1GHz                                       ±4.32dB                         (1)
Conducted Disturbance0.15~30MHz                                    ±3.20dB                         (1)
(1)   This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.


                                                Page 6 of 25                         Report No.: HK1811141565E



2.GENERAL INFORMATION
2.1 ENVIRONMENTAL CONDITIONS
During the measurement the environmental conditions were within the listed ranges:
                  Normal Temperature:                                           25°C
                   Relative Humidity:                                           55 %
                     Air Pressure:                                             101 kPa

2.2 GENERAL DESCRIPTION OF EUT

Product Name:                      Wireless Receiver

Model/Type reference:              UHF-6100
                                   Input :AC 100-240V~50/60Hz
Power supply of adapter:
                                   Output: DC 12V 500mA
Operation Frequency                512~537.5MHz
Hardware Version:                  UHF-6100RX Rev-C2
Software Version:                  UHF-6100RX Rev-C2
Note: For more details, refer to the user’s manual of the EUT.

2.3. DESCRIPTION OF TEST MODES

           NO.                                         TEST MODE DESCRIPTION
             1                                           Receiving at low channel
             2                                         Receiving at middle channel
             3                                           Receiving at high channel
       Note: All the test modes had been tested, the mode 1 was the worst case recorded in the test report.

2.4. RELATED SUBMITTAL(S) / GRANT (S)

This submittal(s) (test report) is intended to comply with Section 15.107&109 of the FCC Part 15, Subpart B
Rules.

2.5. TEST METHODOLOGY
Both conducted and radiated testing was performed according to the procedures in ANSI C63.4 (2014).
Radiated testing was performed at an antenna to EUT distance 3 meters.

2.6. ACCESSORIES USED
 Item            Equipment         Model No.                 Specification                    Remark

   1              Adapter          LX120050                  DC 12V/0.5A                   Market with EUT


                                                  Page 7 of 25                  Report No.: HK1811141565E




2.7 EQUIPMENT USED
                                                                                                   Cal.
    Item       Equipment          Manufacturer         Model No.   Serial No.      Last Cal.
                                                                                                 Interval
                 L.I.S.N.
     1.      Artificial Mains            R&S            ENV216     HKE-002       Dec. 28, 2017 1 Year
                 Network
     2.         Receiver                 R&S            ESCI 7     HKE-010       Dec. 28, 2017 1 Year
             RF automatic
     3.                             Tonscend           JS0806-2    HKE-060       Dec. 28, 2017 1 Year
              control unit
     4.      Horn Antenna        Schewarzbeck         BBHA 9170    HKE-090       Dec. 28, 2017 1 Year
     5.    Spectrum analyzer            Agilent         N9020A     HKE-048       Dec. 28, 2017 1 Year
     6.       Preamplifier        Schwarzbeck          BBV 9743    HKE-006       Dec. 28, 2017 1 Year
     7.    EMI Test Receiver    Rohde & Schwarz         ESCI 7     HKE-010       Dec. 28, 2017 1 Year
           Bilog Broadband
     8.                           Schwarzbeck          VULB9163    HKE-012       Dec. 28, 2017 1 Year
               Antenna
                                                      FMZB 1519
     9.      Loop Antenna         Schwarzbeck                      HKE-014
                                                                    FMZB 1519 Dec.012
                                                                                   28, 2017
                                                                                        May 11,
                                                                                             1 Year
                                                                                                2016 1 Year
                                                         B
    10.      Horn Antenna        Schewarzbeck           9120D      HKE-013       Dec. 28, 2017 1 Year
                                                      EMC051845
    11.      Pre-amplifier              EMCI                       HKE-015       Dec. 28, 2017 1 Year
                                                         SE
    12.      Pre-amplifier              Agilent         83051A     HKE-016       Dec. 28, 2017 1 Year
           EMI Test Software                           JS1120-B
    13.                             Tonscend                       HKE-083       Dec. 28, 2017    N/A
               EZ-EMC                                   Version
    14.      Shielded room         Shiel Hong            4*3*3     HKE-039       Dec. 28, 2017 3 Year
The calibration interval was one year


                                              Page 8 of 25                       Report No.: HK1811141565E



3. RADIATED EMISSION
3.1. MEASUREMENT PROCEDURE
 1. Configure the EUT according to ANSI C63.4. The EUT was placed on the top of the turntable 0.8 meter
    above ground. The phase center of the receiving antenna mounted on the top of a height-variable antenna
    tower was placed 3 meters far away from the turntable.
 2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine the
    position of the highest radiation.
 3. The height of the broadband receiving antenna was varied between one meter and four meters above
    ground to find the maximum emissions field strength of both horizontal and vertical polarization.
 4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
    rotated (from 0 degree to 360 degrees) to find the maximum reading.
 5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth under
    Maximum Hold Mode.
 6. For emissions below 1GHz, use 120KHz RBW and VBW>=3RBW for QP reading.
 7. For emissions above 1GHz, use 1MHz RBW and 3MHz VBW for peak reading. Then 1MHz RBW and
    10Hz VBW for average reading in spectrum analyzer.
 8. When the radiated emissions limits are expressed in terms of the average value of the emissions, and
    pulsed operation is employed, the measurement field strength shall be determined by averaging over one
    complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds.
    As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
    pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
    absolute voltage during a 0.1 second interval during which the field strength is at its maximum values.
 9.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then testing
    will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB
    margin will be repeated one by one using the quasi-peak method for below 1GHz.
 10. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that
    means the emissions level in peak mode also complies with the limit in average mode), then testing will be
    stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in average
    mode again and reported.
 11. Only the worst case is reported.


                                              Page 9 of 25                     Report No.: HK1811141565E



The following table is the setting of spectrum analyzer and receiver.
               Spectrum Parameter                                            Setting
              Start ~Stop Frequency                            30MHz~1000MHz/RBW 120KHz for QP
                                                                        1GHz~12.5GHz
              Start ~Stop Frequency
                                                            1MHz/3MHz for Peak, 1MHz/10Hz for Average


              Receiver Parameter                                             Setting
              Start ~Stop Frequency                            30MHz~1000MHz/RBW 120KHz for QP


                               Page 10 of 25               Report No.: HK1811141565E



3.2. TEST SETUP
                  RADIATED EMISSION TEST SETUP 30MHz-1000MHz




                  RADIATED EMISSION TEST SETUP ABOVE 1000MHz


                              Page 11 of 25                  Report No.: HK1811141565E



3.3. TEST RESULT
                   RADIATED EMISSION BELOW 1GHZ-Horizontal


                                           Page 12 of 25                      Report No.: HK1811141565E



                              RADIATED EMISSION BELOW 1GHZ-Vertical




RESULT: PASS
Note: 1. Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      2. The “Factor” value can be calculated automatically by software of measurement system.
      3. Emissions range from 1GHz to 5GHz have 20dB margin. No recording in the test report.


                                               Page 13 of 25                         Report No.: HK1811141565E



4. FCC LINE CONDUCTED EMISSION TEST
4.1. LIMITS OF LINE CONDUCTED EMISSION TEST

                                                               Maximum RF Line Voltage
             Frequency
                                                    Q.P.( dBuV)                        Average( dBuV)
          150kHz~500kHz                                66-56                                 56-46
           500kHz~5MHz                                   56                                    46
           5MHz~30MHz                                    60                                    50
Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz.


4.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST



                  EUT & Support
                  Units


                                            Page 14 of 25                       Report No.: HK1811141565E



4.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST
1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
   manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
   placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane
   used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm
   non-conductive covering to insulate the EUT from the ground plane.
2. Support equipment, if needed, was placed as per ANSI C63.4.
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
4. All support equipments received AC120V/60Hz power from a LISN, if any.
5. The EUT received DC charging voltage by PC which received 120V/60Hzpower by a LISN..
6. The test program was started. Emissions were measured on each current carrying line of the EUT using a
   spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring
   points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to
   Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a 50
   ohm load and Line 2 connected to the Analyzer / Receiver.
7. Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.
9. The test mode(s) were scanned during the preliminary test.

Then, the EUT configuration and cable configuration of the above highest emission level were recorded for
reference of final testing.


4.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST
1. EUT and support equipment was set up on the test bench as per step 2 of the preliminary test.
2. A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
   Emission frequency and amplitude were recorded into a computer in which correction factors were used to
   calculate the emission level and compare reading to the applicable limit. If EUT emission level was
   less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
   detector.
3. The test data of the worst case condition(s) was reported on the Summary Data page.


                                    Page 15 of 25                  Report No.: HK1811141565E



4.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST
                           Line Conducted Emission Test Line 1-L


                                            Page 16 of 25                       Report No.: HK1811141565E



                                  Line Conducted Emission Test Line 2-N




RESULT: PASS
Note: All the test modes had been tested, the mode 1 was the worst case. Only the data of the worst case
would be record in this test report.


              Page 17 of 25                Report No.: HK1811141565E



APPENDIX A: PHOTOGRAPHS OF TEST SETUP
  FCC LINE CONDUCTED EMISSION TEST SETUP




FCC RADIATED EMISSION TEST SETUP BELOW 1GHZ


              Page 18 of 25              Report No.: HK1811141565E



FCC RADIATED EMISSION TEST SETUP ABOVE 1GHZ


        Page 19 of 25            Report No.: HK1811141565E



APPENDIX B: PHOTOGRAPHS OF EUT
        ALL VIEW OF EUT


 Page 20 of 25       Report No.: HK1811141565E



 TOP VIEW OF EUT




BOTTOM VIEW OF EUT


 Page 21 of 25      Report No.: HK1811141565E



FRONT VIEW OF EUT




BACK VIEW OF EUT


 Page 22 of 25      Report No.: HK1811141565E



LEFT VIEW OF EUT




RIGHT VIEW OF EUT


 Page 23 of 25       Report No.: HK1811141565E



VIEW OF EUT (PORT)




OPEN VIEW OF EUT


   Page 24 of 25         Report No.: HK1811141565E



INTERNAL VIEW OF EUT-1




INTERNAL VIEW OF EUT-2


   Page 25 of 25         Report No.: HK1811141565E



INTERNAL VIEW OF EUT-3




INTERNAL VIEW OF EUT-4




----END OF REPORT---



Document Created: 2018-12-14 10:56:02
Document Modified: 2018-12-14 10:56:02

© 2024 FCC.report