                            MPE TEST REPORT


                Applicant            Alcatel-Lucent Shanghai Bell Co.,Ltd.

                FCC ID               2ADZRXS250WXAB

                Product              XGSPON ONU

                Brand                NOKIA

                Model                XS-250WX-A/XS-240W-A

                Report No.           RBA1709-0095MPE01R1

                Issue Date           January 4, 2018


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance
with the requirements as documented in this report.




                  Performed by: Jiangpeng Lan                    Approved by: Kai Xu




               TA Technology (Shanghai) Co., Ltd.
                  No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86-021-50791141/2/3
                                     FAX: +86-021-50791141/2/3-8000


           MPE Test Report                                                                             Report No: RBA1709-0095MPE01R1




                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 3
 1.1    Notes of the Test Report ......................................................................................................... 3
 1.2    Test facility .............................................................................................................................. 3
 1.3    Testing Location ...................................................................................................................... 4
 1.4    Laboratory Environment .......................................................................................................... 4
2 Description of Equipment under Test .............................................................................................. 5
3 Maximum conducted output power (measured) and antenna Gain ................................................ 6




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 2 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                 Report No: RBA1709-0095MPE01R1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above. This report must not be used by the

client to claim product certification, approval, or endorsement by any government agencies.


1.2 Test facility

CNAS (accreditation number:L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 3 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           MPE Test Report                                                               Report No: RBA1709-0095MPE01R1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




1.4 Laboratory Environment

   Temperature                                             Min. = 18C, Max. = 25 C

   Relative humidity                                       Min. = 30%, Max. = 70%

   Ground system resistance                                < 0.5 
   Ambient noise is checked and found very low and in compliance with requirement of standards.
   Reflection of surrounding objects is minimized and in compliance with requirement of standards.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 4 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                 Report No: RBA1709-0095MPE01R1



2 Description of Equipment under Test

 Client Information
   Applicant                               Alcatel-Lucent Shanghai Bell CO. Ltd.
   Applicant address                       388-389#,Ningqiao Road,Pudong Jinqiao, Shanghai, P.R. China
   Manufacturer                            Alcatel-Lucent Shanghai Bell CO. Ltd.
   Manufacturer address                    388-389#,Ningqiao Road,Pudong Jinqiao, Shanghai, P.R. China


General Technologies
   Model                       XS-250WX-A/XS-240W-A
   SN                          /
   Hardware Version            3FE 48307 AA /3FE 48631 AA
   Software Version            3FE47059
                               December 20, 2016 ~ February 4, 2017 and
   Date of Testing:
                               September 18, 2017~ October 17, 2017



                       XS-250WX-A                                                      XS-240W-A
                      With 10GE port                                              Without 10GE port
  Note: Customer declaration, two models is the same except 10GE port. During the test, both of
  two models are evaluated, XS-250WX-A selected as the worst condition, but only the worst case
  is recorded in this report.


                                   Model                        ONU Part number                Kit Part number
  US ONU                           XS-250WX-A                   3FE 48307 AA                   -
  US Kit                           XS-250WX-A                   3FE 48307 AA                   3FE 48439 AA
  US ONU                           XS-240W-A                    3FE 48631 AA                   -
  US Kit                           XS-240W-A                    3FE 48631 AA                   3FE 48626 AA




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 5 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                 Report No: RBA1709-0095MPE01R1



3 Maximum conducted output power (measured) and antenna Gain

the numeric gain (G) of the antenna with a gain specified in dB is determined by
Numeric gain (G)=10^(antenna gain/10)
                                            Maximum Conducted Output                                         Numeric gain
                                                                                      Antenna Gain
                 Band                             Power (dBm)                                                   (dB)
                                                                                          (dBi)
                                                (dBm)                (mW)
                 SISO Antenna 1                   26               398.107                    3                   1.995
  2.4G           SISO Antenna 2                   25               316.228                    3                   1.995
                 SISO Antenna 3                   26               398.107                    3                   1.995
                 SISO Antenna 1                   24               251.189                    3                   1.995
                 SISO Antenna 2                   24               251.189                    3                   1.995
   5G
                 SISO Antenna 3                   27               501.187                    3                   1.995
                 SISO Antenna 4                   25               316.228                    3                   1.995




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 6 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              MPE Test Report                                                                 Report No: RBA1709-0095MPE01R1

         According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible exposure

         (MPE) are as following




Note1. Occupational/controlled limits apply in situations in which persons are exposed as a consequence of

       their employment provided those persons are fully aware of the potential for exposure and can

       exercise control over their exposure. Limits for occupational/controlled exposure also apply in

       situations when an individual is transient through a location where occupational / controlled limits apply

       provided he or she is made aware of the potential for exposure.

Note2: General population/uncontrolled exposures apply in situations in which the general public may be

       exposed, or in which persons that are exposed as a consequence of their employment may not be fully

       aware of the potential for exposure or can not exercise control over their exposure.




     TA Technology (Shanghai) Co., Ltd.                                                                                  Page 7 of 9
     This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                 Report No: RBA1709-0095MPE01R1
    The maximum permissible exposure for 1500~100,000MHz is 1.0.So



                         Band                                    The maximum permissible exposure


                     Wi-Fi 2.4G                                                    1.0mW/cm2
                       Wi-Fi 5G                                                    1.0mW/cm2



 IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the

antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20

cm from all persons and must not be co-located or operating in conjunction with any other antenna

or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or

the device could result in the device exceeding the RF exposure requirements and void user’s

authority to operate the device.




 TA Technology (Shanghai) Co., Ltd.                                                                                  Page 8 of 9
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           MPE Test Report                                                                 Report No: RBA1709-0095MPE01R1

RF Exposure Calculations:
 The following information provides the minimum separation distance for the highest gain antenna

 provided. This calculation is based on the conducted power, considering maximum power and antenna

 gain. The formula shown in KDB 447498 D01 is used in the calculation.

Equation from KDB 447498 D01 General RF Exposure Guidance v06 (10/23/2015) is:
                                                                        2
                                                        S= PG / 4∏R
                                                                             2
 Where:     S = power density (in appropriate units, e.g. mW/cm )

           P = Time-average maximum tune up procedure (in appropriate units, e.g., mW)

           G = the numeric gain of the antenna

           R = distance to the center of radiation of the antenna (20 cm = limit for MPE)

                                                                                                                        The
                                                                                 Test Result      Limit Value
                           Band                                PG (mW)                      2                  2        MPE
                                                                                 (mW/cm )          (mW/cm )
                                                                                                                        ratio
                             SISO Antenna 1                     794.328            0.158                1.0            0.158
                             SISO Antenna 2                     630.957            0.126                1.0            0.126
   WiFi 2.4G
                             SISO Antenna 3                     794.328            0.158                1.0            0.158
                                   MIMO                        2219.614            0.442                1.0            0.442
                             SISO Antenna 1                     501.187            0.100                1.0            0.100
                             SISO Antenna 2                     501.187            0.100                1.0            0.100
    WiFi 5G                  SISO Antenna 3                    1000.000            0.199                1.0            0.199
                             SISO Antenna 4                     630.957            0.126                1.0            0.126
                                   MIMO                        2633.332            0.524                1.0            0.524
  Note: R = 20cm
       ∏= 3.1416
      The MPE ratio = Mac Test Result÷Limit Value


  So the simultaneous transmitting antenna pairs as below:
  ∑of MPE ratios=WiFi 2.4G + WiFi 5G =0.442+0.524=0.965 <1

 Note: For transmitters, minimum separation distance is 20cm, even if calculations indicate MPE
       distance is less.




  TA Technology (Shanghai) Co., Ltd.                                                                                  Page 9 of 9
  This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2018-01-04 11:28:14
Document Modified: 2018-01-04 11:28:14

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC