Test Report_JBP

FCC ID: 2ADZRG240WJ

Test Report

Download: PDF
FCCID_4489312

                           EMC TEST REPORT

                      Applicant            Nokia Shanghai Bell Co., Ltd.

                      FCC ID               2ADZRG240WJ

                      Product              7368 ISAM ONT

                      Model                G-240W-J

                      Report No.           Y1906B0084-E3V1

                      Issue Date           September 27, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
Code CFR47 Part15B (2018)/ ANSI C63.4 (2014). The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.




              Performed by: Wei Liu/ Manager           Approved by: Guangchang Fan/ Director




               TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86‐021‐50791141/2/3
                                     FAX: +86‐021‐50791141/2/3‐8000


             EMC Test Report                                                                           Report No.: Y1906B0084-E3V1



                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 4
 1.1    Notes of the Test Report ......................................................................................................... 4
 1.2    Test facility .............................................................................................................................. 4
 1.3    Testing Location ...................................................................................................................... 5
2 General Description of Equipment under Test ................................................................................ 6
 2.1    Client Information .................................................................................................................... 6
 2.2    General information ................................................................................................................. 6
 2.3    Applied Standards ................................................................................................................... 8
 2.4    Test Mode................................................................................................................................ 9
3 Test Case Results ........................................................................................................................ 10
 3.1    Radiated Emission ................................................................................................................ 10
 3.2    Conducted Emission ............................................................................................................. 15
4 Main Test Instrument .................................................................................................................... 19
ANNEX A: The EUT Appearance and Test Configuration................................................................. 20
 A.1 EUT Appearance ....................................................................................................................... 20




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 2 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




                                 Summary of measurement results
   Number              Test Case                        Clause in FCC Rules                              Conclusion
          1            Radiated Emission                FCC Part15.109, ANSI C63.4-2014                       PASS
          2            Conducted Emission               FCC Part15.107, ANSI C63.4-2014                       PASS
                                     Test Date: May 30, 2019~ June 26, 2019




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 3 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology
(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein .Measurement Uncertainties were not taken
into account and are published for informational purposes only. This report is written to support
regulatory compliance of the applicable standards stated above.


1.2 Test facility

FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 4 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 5 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




2 General Description of Equipment under Test

2.1 Client Information

   Applicant                             Nokia Shanghai Bell Co., Ltd.
   Applicant address                     No. 388, Ningqiao Rd. Pilot Free Trade Zone, Shanghai, China
   Manufacturer 1                        TAICANG T&W ELECTRONICS CO.,LTD
   Manufacturer address 1                89# Jiang Nan RD, Lu Du, Taicang, Jiangsu, China
   Manufacturer 2                        SHENZHEN TWOWING TECHNOLOGIES CO., LTD
                                         1st-12th Floor, Nangang Industrial Building, Tangtou Industrial
   Manufacturer address 2
                                         Park, Shiyan, Baoan, Shenzhen, Guangdong 518108, China



2.2 General information

                                                    EUT Description
Device Type:                  Movable Device
Model:                        G-240W-J
IMEI:                         /
HW Version:                   PEM2
SW Version:                   3FE48164AGCA97
Antenna Type:                 Internal Antenna
                                        Band                         Tx (MHz)                          Rx (MHz)
                              WIFI 2.4G:                           2412 ~ 2462                       2412 ~ 2462
Frequency:
                              WIFI 5G(U-NII-1):                    5150 ~ 5250                       5150 ~ 5250
                              WIFI 5G(U-NII-3):                    5725 ~ 5850                       5725 ~ 5850
                              WLAN 802.11b: DSSS
Modulation:
                              WLAN 802.11a/g/n/ac: OFDM
                                                     EUT Accessory
                              Manufacturer: Shenzhen SOY Technology Co., Ltd
Adapter 1
                              Model: SUN-1200300
                              Manufacturer: SHENZHEN RUIDE ELECTRONICAL INDUSTRIAL CO.,LTD
Adapter 2
                              Model: RD1203000-C55-20MG
Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 6 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




                    Kit Code                EMA                 Part Description                       Power Adaptor
                                                          2 POTS, 4 GE, Dual band
                                                                    WIFI
                                                             AC3000 802.11ac                           SUN-1200300
 G-240W-J        3FE48008AA         3FE48009AA
                                                              4x4/802.11n 3x3                       RD1203000-C55-20MG
                                                            US Plug in, 2Pin, Wall
                                                               Mounted, 12V

       Auxiliary equipment details

  No.              Name                  Brand name                 Model              NSB code              Valid Until
                                                                                                             No Cal.
   1               Spirent                  TestCenter             DE48E0                       -
                                                                                                             Required
                                                                                                             No Cal.
   2                OLT                 Alcatel-Lucent                N.A                       -
                                                                                                             Required
                                                                                                             No Cal.
   3                 PC                        HP                     N.A                       -
                                                                                                             Required
                                                                                                             No Cal.
   4               Phone                       N.A                    N.A                       -
                                                                                                             Required

       Information of Ports

                                                     Shielded or         Cable type (optic, twisted pair,             Max. Cable
  No.         Port name            Number
                                                     unshielded                       etc.)                             length
   1             Power                  1            unshielded                             -                                -

   2               GE                   4            unshielded                             -                                -

   3             POTS                   2            unshielded                             -                                -

   4              USB                   2             shielded                              -                                -




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 7 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1


2.3 Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:

Test standards
FCC Code CFR47 Part15B (2018)
ANSI C63.4 (2014)




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 8 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                                             Report No.: Y1906B0084-E3V1


2.4 Test Mode

Description: The G-240W-J is a GPON ONT which has 2 POTs, 4 GE ports, 2 USB ports, 2.4G wi-fi
and 5G wi-fi.

The basic functional test in normal room conditions consists of the traffic test and POTs connection
test. G-240W-J runs 4 traffics on each line with DE48E0, the each upstream of 3 GE is 250Mbps, and
downstream is 750Mbps. The POTs keep connecting though OFLT program.




                         Ant0   Ant1 Ant2      Ant0 Ant1 Ant2 Ant3
                           2.4G WiFi                   5G WiFi

                         GPON Port       G-240W-J               DC Jack           DC cable
                                                                                                 PSU
                                           ONT
                            USB x 2         RJ11 x 2      RJ45 x 4



                            U      U
                                                                      GE 1 x 4




                            S      S
                            B      B
                            0      1

     GPON LT Port

         OLT   UP Link           Fiber                  Spirent


                                                                                     LAN Cable
                                                                                    Throughput              WIET                     WIET
                                                              PC                                            2.4G                      5G
                                                                                    Throughput
                                                   Voice Tool & Control Traffic
                                                        Running IxChariot




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 9 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




3 Test Case Results

3.1 Radiated Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C~26°C                     45%~50%                               102.5kPa



Methods of Measurement

The EUT is placed on a non-metallic table 0.8m above the horizontal metal reference ground plane.
The distance between EUT and receive antenna should be 3 meters. During the test, the EUT was
operating in its typical mode. The test method is according to ANSI C63.4-2014. Sweep the whole
frequency band through the range from 30MHz to the 5th harmonic of the carrier. During the test, the
height of receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed
under horizontal and vertical polarization. The turn table shall be rotated from 0 to 360 degrees for
detecting the maximum of radiated signal level.
The data of cable loss and antenna factor has been calibrated in full testing frequency range before
the testing. During the test, the EUT is worked at maximum output power.
Set the spectrum analyzer in the following:
Below 1GHz:
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO
Above 1GHz:
(a) PEAK Detector: RBW=1MHz / VBW=3MHz/ Sweep=AUTO
(b) AVERAGE Detector: RBW=1MHz / VBW=3MHz / Sweep=AUTO

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the
worst case was recorded.

During the test, The basic functional test in normal room conditions consists of the traffic test and
POTs connection test. G-240W-J runs 4 traffics on each line with DE48E0, the each upstream of 3
GE is 250Mbps, and downstream is 750Mbps. The POTs keep connecting though OFLT program.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 10 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1

Test Setup



Below 1GHz




     Above 1GHz




Note: Area side:2.4mX3.6m

Antenna Tower meets ANSI C63.4 requirements for measurements above 1 GHz by keeping the
antenna aimed at the EUT during the antenna’s ascent/ descent along the antenna mast.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 11 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1
Limits

                  Frequency                               Field Strength
                                                                                                   Detector
                    (MHz)                                   (dBμV/m)
                     30 -88                                     40.0                              Quasi-peak
                    88-216                                      43.5                              Quasi-peak
                   216 – 960                                    46.0                              Quasi-peak
                   960-1000                                     54.0                              Quasi-peak
     1000-5th harmonic of the highest                             54                                Average
   frequency or 40GHz,which is lower                              74                                  Peak



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.


                              Frequency                                           Uncertainty
                         30MHz~200MHz                                               4.02 dB
                        200MHz~1000MHz                                              3.28 dB
                           1GHz~18GHz                                               3.70 dB
                         18GHz~26.5GHz                                              5.78 dB
                         26.5GHz~40GHz                                              5.82 dB




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 12 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                                         Report No.: Y1906B0084-E3V1
Test Results

Sweep the whole frequency band through the range from 30MHz to the 5th harmonic of the carrier,
the Emissions in the frequency band 18GHz- 40GHz is more than 20dB below the limit are not
reported.

The following graphs display the maximum values of horizontal and vertical by software.
For above 1GHz, Blue trace uses the peak detection, Green trace uses the average detection.
                                                             FCC RE 0.03-1GHz QP Class B

                             80

                             70

                             60
                                                                                                                FCC RE QP
                             50
            Level in dBμV/




                             40

                             30

                             20

                             10

                              0
                              30M          50   60      80    100M                200      300    400   500          800   1G

                                                                         Frequency in Hz


                                                Radiated Emission from 30MHz to 1GHz
Frequency                     Quasi-Peak Height              Azimuth                         Correct          Margin   Limit
                                                Polarization
  (MHz)                        (dBuV/m)   (cm)                (deg)                         Factor (dB)        (dB)  (dBuV/m)
34.927500                           32.9        100.0                V           258.0           16.3          7.1          40.0
75.953750                           28.6        125.0                V            22.0           10.2          11.4         40.0
160.305000                          30.4        100.0                V             0.0           10.1          13.1         43.5
300.023750                          22.0        175.0                V             6.0           15.3          24.0         46.0
479.920000                          19.2        125.0                V            22.0           20.8          26.8         46.0
797.631250                          39.2        100.0                H            31.0           24.9          6.8          46.0
Remark: 1. Correction Factor = Antenna factor+ Insertion loss(cable loss+amplifier gain)
        2. Margin = Limit – Quasi-Peak




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 13 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                                 Report No.: Y1906B0084-E3V1


                                                        FCC RE 1G-18GHz PK+AV Class B

                               120


                               100


                               80                                                                          FCC RE PK
              Level in dBμV/




                               60                                                                          FCC RE AV

                               40


                               20


                                0
                                 1G               2G          3G       4G    5G      6     8      10G              18G

                                                                   Frequency in Hz


                                               Radiated Emission from 1GHz to 18GHz
                                                                                         Correct
                                        Peak   Height              Azimuth                              Margin   Limit
    Frequency                                         Polarization                       Factor
                                      (dBuV/m) (cm)                 (deg)                                (dB)  (dBuV/m)
      (MHz)                                                                               (dB)
   1197.625000                          54.6    100.0          V            230.0         -11.2          19.4          74.0
   1788.375000                          49.2    100.0          V            186.0         -9.4           24.8          74.0
   1864.875000                          55.1    100.0          V            186.0         -9.2           18.9          74.0
   2487.500000                          50.0    100.0          V            186.0         -6.4           24.0          74.0
   3998.375000                          48.6    100.0          H            138.0         -2.7           25.4          74.0
   6631.250000                          48.9    200.0          H            327.0          5.0           25.1          74.0


                                                                                         Correct
    Frequency                          Average Height              Azimuth                              Margin   Limit
                                                      Polarization                       Factor
      (MHz)                           (dBuV/m) (cm)                 (deg)                                (dB)  (dBuV/m)
                                                                                          (dB)
   1108.375000                          34.6    100.0          H            184.0         -11.4          19.4          54.0
   1469.625000                          32.8    100.0          H            194.0         -10.5          21.2          54.0
   1945.625000                          33.5    100.0          V            198.0         -9.0           20.5          54.0
   2487.500000                          45.1    100.0          V            186.0         -6.4           8.9           54.0
   3998.375000                          39.7    100.0          H            138.0         -2.7           14.3          54.0
   6699.250000                          37.7    100.0          V            326.0          5.0           16.3          54.0




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 14 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                            Report No.: Y1906B0084-E3V1




3.2 Conducted Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C ~26°C                    50%~55%                               102.5kPa

Methods of Measurement

The EUT is placed on a non-metallic table of 80cm height above the horizontal metal reference
ground plane. During the test, the EUT was operating in its typical mode. The test method is
according to ANSI C63.4-2014. Connect the AC power line of the EUT to the L.I.S.N. Use EMI
receiver to detect the average and Quasi-peak value. RBW is set to 9 kHz, VBW is set to 30kHz. The
measurement result should include both L line and N line.

During the test, The basic functional test in normal room conditions consists of the traffic test and
POTs connection test. G-240W-J runs 4 traffics on each line with DE48E0, the each upstream of 3
GE is 250Mbps, and downstream is 750Mbps. The POTs keep connecting though OFLT program.

Test Setup




Note: Power Supply is AC Power source and it is used to change the voltage 120V/60Hz.

Limits

           Frequency                                            Conducted Limits(dBμV)
             (MHz)                              Quasi-peak                                      Average
                                                            *                                            *
            0.15 - 0.5                           66 to 56                                      56 to 46
              0.5 - 5                                56                                            46
              5 - 30                                 60                                            50
   *:
        Decreases with the logarithm of the frequency.

Measurement Uncertainty


TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 15 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.




           EMC Test Report                                                              Report No.: Y1906B0084-E3V1
Test Results

Following plots, Blue trace uses the peak detection; Green trace uses the average detection.




                                                                          Meas.
Frequency        QuasiPeak         Average        Limit      Margin                  Bandwidth                           Corr.
                                                                          Time                        Line     Filter
  (MHz)           (dBµV)           (dBµV)        (dBµV)       (dB)                     (kHz)                             (dB)
                                                                          (ms)
    0.15            48.39              ---        65.88       17.49      1000.0          9.000          L1      ON       19.05
    0.31               ---           31.24        49.92       18.68      1000.0          9.000          L1      ON       19.18
    0.72            27.74              ---        56.00       28.26      1000.0          9.000          L1      ON       19.25
    0.73               ---           22.32        46.00       23.68      1000.0          9.000          L1      ON       19.24
    1.49               ---           25.13        46.00       20.87      1000.0          9.000          L1      ON       19.18
    1.50            30.91              ---        56.00       25.09      1000.0          9.000          L1      ON       19.18
    3.63            35.27              ---        56.00       20.73      1000.0          9.000          L1      ON       19.08
    5.00               ---           23.99        46.00       22.01      1000.0          9.000          L1      ON       19.08
    8.83            38.94              ---        60.00       21.06      1000.0          9.000          L1      ON       19.27
   10.85               ---           35.77        50.00       14.23      1000.0          9.000          L1      ON       19.36
   12.41               ---           28.44        50.00       21.56      1000.0          9.000          L1      ON       19.43
   12.48            31.99              ---        60.00       28.01      1000.0          9.000          L1      ON       19.44
Remark: Correct factor=cable loss + LISN factor
                                           L line
                        Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 17 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




                                                                          Meas.
Frequency        QuasiPeak         Average        Limit      Margin                  Bandwidth                           Corr.
                                                                          Time                        Line     Filter
  (MHz)           (dBµV)           (dBµV)        (dBµV)       (dB)                     (kHz)                             (dB)
                                                                          (ms)
    0.17            45.93              ---        65.17       19.24      1000.0          9.000          N       ON       19.15
    0.33               ---           31.54        49.34       17.80      1000.0          9.000          N       ON       19.19
    0.67               ---           27.43        46.00       18.57      1000.0          9.000          N       ON       19.28
    0.80            27.55              ---        56.00       28.45      1000.0          9.000          N       ON       19.24
    1.20               ---           28.72        46.00       17.28      1000.0          9.000          N       ON       19.23
    1.75            33.53              ---        56.00       22.47      1000.0          9.000          N       ON       19.16
    3.62            34.98              ---        56.00       21.02      1000.0          9.000          N       ON       19.08
    4.99               ---           27.36        46.00       18.64      1000.0          9.000          N       ON       19.08
   10.54            40.14              ---        60.00       19.86      1000.0          9.000          N       ON       19.38
   10.83               ---           36.38        50.00       13.62      1000.0          9.000          N       ON       19.36
   12.42               ---           29.52        50.00       20.48      1000.0          9.000          N       ON       19.41
   12.42            33.97              ---        60.00       26.03      1000.0          9.000          N       ON       19.41
Remark: Correct factor=cable loss + LISN factor
                                           N line
                        Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 18 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




4 Main Test Instrument

                                                                            Serial        Calibration        Expiration
         Name                 Manufacturer                 Type
                                                                           Number            Date              Time
       Spectrum                                                           15195-01-
                                    R&S                   FSV40                            2019-05-19        2020-05-18
       Analyzer                                                              00
       EMI Test
                                    R&S                    ESCI             100948        2019-05-19         2020-05-18
       Receiver
    Trilog Antenna          SCHWARZBECK                VULB 9163          9163-201         2017-11-18        2019-11-17
    Horn Antenna                    R&S                   HF907             100126        2018-07-07         2020-07-06
    Standard Gain
                              ETS-Lindgren               3160-09          00102643        2018-06-20         2020-06-19
        Horn
    Standard Gain                                      QSH-SL-26-
                                STEATITE                                     16779        2017-07-20         2019-07-19
        Horn                                            40-K-15
       EMI Test
                                    R&S                    ESR              101667        2019-05-19         2020-05-18
       Receiver
          LISN                      R&S                  ENV216             101171        2016-12-16        2019-12-15
     Bore Sight
                                    ETS                   2171B           00058752               /                 /
    Antenna mast
    Test software                 EMC32                    R&S               9.26.0              /                 /




                                             *****END OF REPORT *****




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 19 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1


ANNEX A: The EUT Appearance and Test Configuration

A.1 EUT Appearance




                                                        Front Side




                                                        Back Side
                                                         a: EUT




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 20 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: Y1906B0084-E3V1




                                                        Adapter 1




                                                        Adapter 2
                                                        b: Adapter
                                           Picture 1 EUT and Accessory


TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 21 of 21
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-10-25 14:03:28
Document Modified: 2019-10-25 14:03:28

© 2024 FCC.report