Test Report

FCC ID: 2ADZR7577WPONAPE

Test Report

Download: PDF
FCCID_3956519

                                          FCC PART 15.255
                                              TEST REPORT
                                                             For

                              Nokia Shanghai Bell Co. Ltd.
                 No. 388, Ningqiao Rd. Pilot Free Trade Zone, Shanghai, China 201206


                                FCC ID: 2ADZR7577WPONAPE



             Report Type:                               Product Name:
             Original Report                            WPON


                  Report Number:          RSH180530050-00B


                      Report Date:        2018-06-07
                                           Jerry Zhang

                                           EMC Manager
                      Reviewed By:
                                          Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:         No.69 Pulongcun, Puxinhu Industry Area,
                                          Tangxia, Dongguan, Guangdong, China
                                          Tel: +86-769-86858888
                                          Fax: +86-769-86858891
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal Government.
* This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                         Report No.: RSH180530050-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
 TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................4
 FAR FIELD BOUNDARY CALCULATIONS ......................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................6
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8

FCC§1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ...............................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
FCC§15.203 - ANTENNA REQUIREMENT............................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................................11
FCC §15.207 (A) – AC LINE CONDUCTED EMISSIONS ....................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC§15.205, §15.209&§15.255(D)- TRANSMITTER SPURIOUS EMISSIONS .................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  TEST EQUIPMENT SETUP ............................................................................................................................................17
  TEST PROCEDURE ......................................................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  ENVIRONMENTAL CONDITIONS ..................................................................................................................................19
  TEST DATA ................................................................................................................................................................19
§15.255(A) (H)– OPERATION RESTRICTION AND GROUP INSTALLTION.................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  RESULT OF OPERATION RESTRICTION ........................................................................................................................25
  RESULT OF GROUP INSTALLATION .............................................................................................................................25




                                                                                                                                                            Page 2 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RSH180530050-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                          EUT Name:       WPON
                          EUT Model:      WPON AP-Ext
                              FCC ID:     2ADZR7577WPONAPE
                  Rated Input Voltage:    AC 100-240V
                  External Dimension:     246mm(L)* 160 mm(W)*73mm(H)
                       Serial Number:     180530050
                  EUT Received Date:      2018.05.21


Objective
This type approval report is prepared on behalf of Nokia Shanghai Bell Co. Ltd. in accordance with Part 2-
Subpart J, and Part 15-Subparts A, B and C of the Federal Communication Commissions rules.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203 15.205 15.207 15.209 and 15.255 rules.

This device is a modified version based on model: WPON AP-Pole, FCC ID: 2ADZR7577WPONAPP, granted
on 2018-07-17, the difference is the 60 GHz module 2 & 3 and related antennas of Model: WPON AP-Pole were
removed by the applicant, the enclosure, PCB boards, 60 GHz module 1 & BT with antennas are fully identical.

The change made to the device affected AC Line Conducted Emissions test, and Spurious Emissions test,
the data for the items recorded in this report, the other items please refer to the related report for FCC ID:
2ADZR7577WPONAPP


Related Submittal(s)/Grant(s)
FCC Part 15C DSS submissions with FCC ID: 2ADZR7577WPONAPE.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




                                                                                                    Page 3 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RSH180530050-00B

Test Equipment List and Details
                                                                      Serial      Calibration    Calibration
      Manufacturer            Description           Model
                                                                    Number           Date         Due Date
           R&S             EMI Test Receiver       ESCS 30         830245/006     2017-12-11     2018-12-11
           R&S            Two-line V-network       ENV 216           101614       2017-12-08     2018-12-08
           R&S              Test Software           EMC32         Version8.53.0      N/A            N/A
         Unknown            Coaxial Cable         C-NJNJ-50        C-0200-01      2017-09-05     2018-09-05
           R&S             EMI Test Receiver         ESCI            100224       2017-12-11     2018-12-11
      Sunol Sciences           Antenna               JB3           A060611-1      2017-11-10     2020-11-10
            HP                 Amplifier            8447D         2727A05902      2017-09-05     2018-09-05
           R&S            Spectrum Analyzer         8564E         3943A01781      2018-01-04     2019-01-04
          Farad             Test Software          EZ-EMC           V1.1.4.2         N/A            N/A
         Unknown            Coaxial Cable         C-NJNJ-50        C-0400-01      2017-09-05     2018-09-05
         Unknown            Coaxial Cable         C-NJNJ-50        C-0075-01      2017-09-05     2018-09-05
         Unknown            Coaxial Cable         C-NJNJ-50        C-1000-01      2017-09-05     2018-09-05
         TDK RF             Horn Antenna          HRN-0118           130 084      2016-01-05     2019-01-04
           Mini              Pre-amplifier       ZVA-183-S+       5969001149      2017-09-05     2018-09-05
           R&S            Spectrum Analyzer         FSP 38           100478       2017-12-08     2018-12-08
        Ducommun                                                   1007726-01
                             Horn Antenna       ARH-4223-02                        2016-11-18    2019-11-18
       Technolagies                                                   1304
        Ducommun                                                   1007726-01
                             Horn Antenna       ARH-2823-02                        2016-11-18    2019-11-18
       Technolagies                                                   1302
                                                    QLW-
         Quinstar              Amplifier                          15964001001      2017-06-27    2018-06-27
                                                 18405536-JO
                                                 WR19/M19H
          OML              Harmonic Mixer                           U60313-1       2016-10-14    2019-10-14
                                                     WD
          OML                Horn Antenna          M19RH            11648-01       2016-10-14    2019-10-14
                                                   Agilent
          Agilent          Harmonic Mixer                         2521A01767       2016-12-07    2019-12-07
                                                   11970V
     Flann Micowave          Horn Antenna         861V/385             736         2016-12-07    2019-12-07
                                                 WR12/M12H
          OML              Harmonic Mixer                           E60120-1       2016-10-19    2019-10-19
                                                     WD
          OML                Horn Antenna          M12RH            E60120-2       2016-10-19    2019-10-19
                                                 WR08/M08H
          OML              Harmonic Mixer                           F60313-1       2016-10-24    2019-10-24
                                                     WD
          OML                Horn Antenna          M08RH            F60313-2       2016-10-24    2019-10-24
                                                 WR05/M05H
          OML              Harmonic Mixer                           G60106-1       2016-10-27    2019-10-27
                                                     WD
          OML                Horn Antenna          M05RH            G60106-2       2016-10-27    2019-10-27
                                                   DET-15-
         millitech            RF Detector                            A18521        2017-12-15    2019-12-15
                                                   RPFW0
                           Digital Phosphor
        Tektronix                                  TDS 3054         B015264         2017-07-18 2018-07-18
                             Oscilloscope
          Agilent          Signal Generator         E8247C        MY43321350 2017-12-11 2018-12-11
                           mm-Wave Source
          Agilent                                   83557A        2735A00145        2017-08-16 2019-08-15
                               Modules
          UNI-T               Multimeter            UT39A         M130199938        2018-05-09 2019-05-09
                           High Temperature
        Dongzhixu                                   DP1000        201105083-4       2017-08-28 2018-08-28
                             Test Chamber
           OML                 Diplexer             DPL.26          EM-128          2016-10-11 2019-10-10
   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).

                                                                                                     Page 4 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RSH180530050-00B

FAR Field Boundary Calculations
The far-field boundary is given in ANSI C63.10-2013:



Where:
   D is the largest dimension of the antenna aperture in m and
       is the free-space wavelength in m at the frequency of measurement.

The minimum test distance for the frequency range 40GHz-200GHz determine as below:

                                                                    Largest Dimension
                                                                                            Minimum Test
                                              Frequency Range          of the Horn
      Manufacturer            Model                                                          Distance Rm
                                                   (GHz)                Antenna
                                                                                                 (m)
                                                                           (mm)
           OML                M19RH                  40-60                  46.3                  0.57
     Alpha Industries        861V/385                50-75                  43.7                  0.64
           OML                M12RH                  60-90                 30.02                  0.36
           OML                M08RH                 90-140                  19.7                  0.23
           OML                M05RH                140-220                  12.5                  0.30

Note: the maximum antenna dimension of the EUT was 18 mm. This length is smaller than the largest dimension of
the smallest Horn Antenna used to measure up in the frequency range 40 GHz to 140 GHz. and larger than 140GHz to
220GHz. Given that the test distances used were 1.0 m from 40 GHz to 90 GHz, and 0.5 m from 90 GHz to 200 GHz,
it can be seen that the EUT was always in the Far-field of the Receive Antenna during all Radiated Emissions Tests.




                                                                                                         Page 5 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSH180530050-00B

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in Engineering Mode, which was provided by the manufacturer.
The device built in a 60 GHz module, only supports SISO mode

The module only supports 3 channels as below:

                                  Frequency                                            Frequency
    Channel Number                                         Channel Number
                                    (MHz)                                                (MHz)
            1                          58320                      3                      62640
            2                          60480                      /                         /


EUT Exercise Software
The software “QRCT3.0” was used for testing, which was provided by manufacturer. The worst condition
(maximum power) was configured by system default setting. The worst data rate: 1Gbps.


Equipment Modifications
No modifications were made to the EUT.


Local Support Equipment List and Details

          Manufacturer                 Description             Model               Serial Number
             HUAWEI                   GPON Terminal        HG8245Q2         2102311RGB6RH1000087
                Sprient                 SmartBits              600B                   DE7885



Support Cable List and Details

          Cable           Shielding                     Length
                                         Ferrite Core                  From Port                To
        Description         Type                         (m)
        RJ45 Cable           yes               no         10             EUT           GPON Terminal
       Optical Cable         no                no         10             EUT             SmartBits




                                                                                                     Page 6 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RSH180530050-00B


Block Diagram of Test Setup




                                                                       Page 7 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RSH180530050-00B

SUMMARY OF TEST RESULTS

                 FCC Rules                    Description of Test                    Result

                                             Maximum Permissible
              §1.1310&§2.1091                                                     Compliance
                                                  Exposure
                   §15.203                   Antenna Requirement                  Compliance

                 §15.207 (a)             AC Line Conducted Emissions              Compliance

               § 15.255 (e)(1)                Occupied Bandwidth                  Compliance*

                 §15.255 (c)                      EIRP Power                      Compliance*

                 §15.255 (e)             Peak Conducted Output Power              Compliance*

                 §15.255 (d)                  Spurious Emissions                  Compliance

                 §15.255 (f)                  Frequency Stability                 Compliance*
                                           Operation Restriction And
                §15.255 (a)(h)                                                    Compliance
                                              Group Installation

Note:
Compliance*: Due to the similarity, please refer to the test report of FCC ID: 2ADZR7577WPONAPP (Test report NO.:
RSH180504050-00CM2).




                                                                                                   Page 8 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RSH180530050-00B

FCC§1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard
According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                          (B) Limits for General Population/Uncontrolled Exposure
 Frequency Range        Electric Field       Magnetic Field        Power Density            Averaging Time
      (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)                (minutes)
     0.3–1.34                614                   1.63                 *(100)                    30
     1.34–30                824/f                 2.19/f               *(180/f²)                  30
     30–300                 27.5                  0.073                   0.2                     30
    300–1500                  /                      /                  f/1500                    30
  1500–100,000                /                      /                    1.0                     30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculation Formula:

Prediction of Power Density at the distance of the applicable MPE Limit

S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);
For simultaneously transmit system, the calculated power density should comply with:




                                                                                                   Page 9 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RSH180530050-00B

Calculated Data:

                                         E.I.R.P        Evaluation     Power
                 Frequency                                                           MPE Limit
      Radio                                              Distance     Density
                   (GHz)          (dBm)        (mW)                                  (mW/cm2)
                                                          (cm)       (mW/cm2)
      60G
                 58.32-62.64       31         1258.93      25           0.16            1.0
    Module 1
    Bluetooth    2.402-2.48       2.92         1.96        25          0.0003           1.0

Note: The output power was declared by manufacturer(Bluetooth conducted power is -2dBm, antenna gain
4.92dBi)
The 60GHz radio and Bluetooth can transmit simultaneously:




= S60G1/Limit60G1 + SBT/LimitBT

= 0.16/1.0 + 0.0003/1.0

=0.1603

  Result: The device complied with the applicable MPE Limit at the 25 cm distance.




                                                                                         Page 10 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RSH180530050-00B

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
For intentional device, according to §15.203, an intentional radiator shall be designed to ensure that no
antenna other than that furnished by the responsible party shall be used.


Antenna Connector Construction
The EUT has 3 internal antennas, which can be seen in the EUT internal Photos. Therefore, the EUT
complied with the antenna requirements stated in FCC Rules Part 15 Subpart C Section 15.203.
Result: Compliant.




                                                                                                 Page 11 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RSH180530050-00B

FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.
The spacing between the peripherals was 10 cm.

The adapter was connected to a 120 VAC/60 Hz power source


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                       IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                              Page 12 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RSH180530050-00B

Test Procedure
During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation

The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207.


Test Data
     Environmental Conditions

              Temperature:             28 C
         Relative Humidity:            66 %
             ATM Pressure:           101.3 kPa

      The testing was performed by Sider Huang on 2018-06-07.




                                                                                            Page 13 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RSH180530050-00B

    Test Mode: Transmitting(antenna 1 active+BT)

     AC120 V, 60 Hz, Line:


                          80

                          70
                                                                                                        Quasi-Peak Limit
                          60

                                                                                                           Average Limit
                          50
           Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k       300   400 500      800 1M       2M     3M     4M 5M 6     8 10M          20M     30M
                                                                 Frequency in Hz



     Frequency                   QuasiPeak           Bandwidth              Corr.      Margin        Limit
                                                                   Line                                             Comment
       (MHz)                      (dBμV)               (kHz)                (dB)        (dB)        (dBμV)
      0.150000                      33.4               9.000        L1      11.2        32.6          66.0          Compliance
      0.188994                     38.2                9.000        L1       10.7       25.9           64.1         Compliance
      0.198249                     38.8                9.000        L1       10.6       24.9           63.7         Compliance
      0.288307                     30.9                9.000        L1       10.2       29.7           60.6         Compliance
      1.190776                     30.1                9.000        L1       9.8        25.9           56.0         Compliance
      1.249088                     26.7                9.000        L1       9.8        29.3           56.0         Compliance

     Frequency                    Average            Bandwidth              Corr.      Margin        Limit
                                                                   Line                                             Comment
       (MHz)                      (dBμV)               (kHz)                (dB)        (dB)        (dBμV)
      0.201433                      24.2               9.000        L1      10.6        29.4          53.6          Compliance
      0.396530                     21.3                9.000        L1       10.0       26.6           47.9         Compliance
      0.419276                     20.6                9.000        L1       10.0       26.9           47.5         Compliance
      0.443327                     21.1                9.000        L1       9.9        25.9           47.0         Compliance
      1.144267                     22.6                9.000        L1       9.8        23.4           46.0         Compliance
      1.289541                     21.5                9.000        L1       9.8        24.5           46.0         Compliance




                                                                                                                       Page 14 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RSH180530050-00B

     AC120 V, 60 Hz, Neutral:


                          80

                          70
                                                                                                        Quasi-Peak Limit
                          60

                                                                                                           Average Limit
                          50
           Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k       300   400 500      800 1M       2M     3M     4M 5M 6     8 10M          20M     30M
                                                                 Frequency in Hz



     Frequency                   QuasiPeak           Bandwidth              Corr.      Margin        Limit
                                                                   Line                                             Comment
       (MHz)                      (dBμV)               (kHz)                (dB)        (dB)        (dBμV)
      0.169044                      31.6               9.000        N       10.9        33.4          65.0          Compliance
      0.186006                     34.4                9.000        N        10.7       29.8           64.2         Compliance
      0.193566                     39.2                9.000        N        10.7       24.7           63.9         Compliance
      0.206306                     36.9                9.000        N        10.6       26.5           63.4         Compliance
      0.865782                     28.5                9.000        N        9.8        27.5           56.0         Compliance
      1.144267                     30.0                9.000        N        9.8        26.0           56.0         Compliance

     Frequency                    Average            Bandwidth              Corr.      Margin        Limit
                                                                   Line                                             Comment
       (MHz)                      (dBμV)               (kHz)                (dB)        (dB)        (dBμV)
      0.195114                      25.3               9.000        N       10.7        28.5          53.8          Compliance
      0.419276                     20.5                9.000        N        10.0       27.0           47.5         Compliance
      0.443327                     21.0                9.000        N        9.9        26.0           47.0         Compliance
      1.239175                     25.0                9.000        N        9.8        21.0           46.0         Compliance
      1.289541                     22.3                9.000        N        9.8        23.7           46.0         Compliance
     15.616430                     20.7                9.000        N        10.0       29.3           50.0         Compliance




                                                                                                                       Page 15 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSH180530050-00B

FCC§15.205, §15.209&§15.255(d)- TRANSMITTER SPURIOUS EMISSIONS
Applicable Standard
(d) Limits on spurious emissions:
(1) The power density of any emissions outside the 57-64 GHz band shall consist solely of spurious
emissions.

(2) Radiated emissions below 40 GHz shall not exceed the general limits in §15.209.

(3) Between 40 GHz and 200 GHz, the level of these emissions shall not exceed 90 pW/cm2 at a distance
of 3 meters.

(4) The levels of the spurious emissions shall not exceed the level of the fundamental emission.


EUT Setup
Below 1 GHz:




                                                                                               Page 16 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RSH180530050-00B

1-26.5 GHz:

                                  1-26.5GHz:3m




26.5-40 GHz:


                                           1m




Above 40GHz:

The antenna is scanned around the entire perimeter surface of the EUT, in both horizontal and vertical
polarizations, at the distance of 1.0 m from 40 GHz to 90 GHz, and 0.5 m from 90 GHz to 200 GHz.

The radiated emission and out of band emission tests were performed in the 3 meters chamber test site A,
using the setup accordance with the ANSI C63.10-2013 The specification used was the FCC 15.209/15.205
and FCC 15.255 limits.


Test Equipment Setup
The system was investigated from 30 MHz to 200 GHz.




                                                                                               Page 17 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSH180530050-00B

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

              Frequency Range             RBW          Video B/W        IF B/W         Detector
             30 MHz – 1000 MHz           120 kHz        300 kHz         120 kHz           QP
                                          1MHz           3 MHz             /              PK
                  1-40 GHz
                                          1MHz            10 Hz            /             Ave
              40 GHz – 200 GHz            1MHz           3 MHz             /              PK


Test Procedure
Refer to ANSI C63.10-2013 Clauses 9.9, 9.12, and 9.13.
A Maximizing procedure was performed to ensure that the highest emissions from the EUT were actually
measured in all of the Test Arrangements of the EUT and Local Support Equipment.

In accordance with FCC Rules Part 15 Subpart A Section 15.35, from 30 MHz to 1 GHz all radiated
emissions measurements were made using a Quasi-peak Detector, and from 1 GHz to 40 GHz, all radiated
emissions measurements were made using a Peak Detector and CISPR Average Detector. In accordance
with FCC Rules Part 15 Subpart C Section 15.255, from 40 GHz to 200 GHz, all radiated emissions
measurements were made using a Peak Detector.

According to C63.10, the 26.5-40GHz test result shall be extrapolated to the specified distance using an
extrapolation factor of 20dB/decade from 3m to 1m

Distance extrapolation factor =20 log (specific distance [3m]/test distance [1m]) dB= 9.54 dB

All emissions under the average limit and under the noise floor have not recorded in the report.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

Corrected = Antenna Loss + Cable Loss - Amplifier Gain

Or

Corrected Amplitude = Antenna Loss + Cable Loss - Amplifier Gain- Distance extrapolation factor

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

Result = Reading + Corrected

Margin = Limit - Result




                                                                                                   Page 18 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RSH180530050-00B

Environmental Conditions

              Temperature:              29.4 C
         Relative Humidity:              37 %
             ATM Pressure:             101.3 kPa

      The testing was performed by Steven Zuo,Vern Shen on 2018-05-21.


Test Data
Please refer to the following table:

     Test Mode: Transmitting(ANT 1 was the worst)

     30MHz-1GHz (Middle channel was the worst)

     Horizontal

        Frequency       Reading                     Corrected      Result       Limit      Margin
                                       Detector
          (MHz)         (dBuV)                       (dB/m)      (dBuV/m)     (dBuV/m)      (dB)
         67.8300          37.89           QP         -11.59        26.30        40.00       13.70
         250.1900         35.58           QP          -6.18        29.40        46.00       16.60
         375.3200         30.86           QP          -2.66        28.20        46.00       17.80
         600.3600         35.50           QP          0.90         36.40        46.00       9.60
         800.1800         36.61           QP          4.59         41.20        46.00       4.80
         875.8400         30.17           QP          5.53         35.70        46.00       10.30




                                                                                              Page 19 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSH180530050-00B

     Vertical

        Frequency      Reading                      Corrected     Result       Limit      Margin
                                    Detector
          (MHz)        (dBuV)                        (dB/m)     (dBuV/m)     (dBuV/m)      (dB)
          40.6700        40.87         QP             -6.37      34.50         40.00       5.50
          66.8600        42.96         QP            -11.66      31.30         40.00       8.70
         500.4500        37.81         QP             -0.31      37.50         46.00       8.50
         600.3600        37.20         QP             0.90       38.10         46.00       7.90
         700.2700        34.31         QP             3.19       37.50         46.00       8.50
         800.1800        31.61         QP             4.59       36.20         46.00       9.80




                                                                                             Page 20 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSH180530050-00B

     1GHz - 40GHz(Middle channel was the worst)

     Horizontal
        Frequency      Reading                      Corrected     Result       Limit      Margin
                                    Detector
          (MHz)        (dBuV)                        (dB/m)     (dBuV/m)     (dBuV/m)      (dB)
         7290.000        42.75        peak            12.44      55.19         74.00       18.81
         7290.000        38.97        AVG             12.44      51.41         54.00       2.59
        17891.026        34.85        peak            28.47      63.32         74.00       10.68
        17891.026        22.17        AVG             28.47      50.64         54.00       3.36
        25028.846        39.86        peak            10.88      50.74         74.00       23.26
        25028.846        29.66        AVG             10.88      40.54         54.00       13.46
        39433.000        48.38        peak            15.90      64.28         74.00       9.72
        39433.000        35.84        AVG             15.90      51.74         54.00       2.26




                                                                                             Page 21 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSH180530050-00B




     Vertical
        Frequency      Reading                      Corrected     Result       Limit      Margin
                                    Detector
          (MHz)        (dBuV)                        (dB/m)     (dBuV/m)     (dBuV/m)      (dB)
         7290.000        40.60        peak            12.44      53.04         74.00       20.96
         7290.000        33.33        AVG             12.44      45.77         54.00       8.23
        18000.000        35.29        peak            28.33      63.62         74.00       10.38
        18000.000        21.98        AVG             28.33      50.31         54.00       3.69
        26500.000        40.37        peak            11.11      51.48         74.00       22.52
        26500.000        30.42        AVG             11.11      41.53         54.00       12.47
        39055.000        50.15        peak            16.21      66.36         74.00       7.64
        39055.000        37.00        AVG             16.21      53.21         54.00       0.79




                                                                                             Page 22 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RSH180530050-00B




                                                                      Page 23 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RSH180530050-00B

40GHz~200GHz:


                         Receiver             Rx Antenna         Corrected     EIPR      Power
    Frequency                                                                                           Limit
                                                                 Amplitude     Power     Density
                  Reading     Detector      Polar     Factor
          GHz      dBμV      PK/QP/AV        H/V    dB(1/m)   dBμV/m            dBm     pW/cm^2      pW/cm^2
                                             Frequency: 58.32 GHz
       47.9        38.90         PK           H      40.33     79.23           -25.47       2.51         90
       47.9        39.12         PK           V      40.33     79.45           -25.25       2.64         90
       77.55       42.98         PK           H      45.87     88.85           -15.85      22.99         90
       77.55       43.10         PK           V      45.87     88.97           -15.73      23.64         90
      116.64       45.87         PK           H      53.18     99.05           -11.67       60.2         90
      116.64       44.10         PK           V      53.18     97.28           -13.44      40.05         90
                                             Frequency: 60.48GHz
       48.9        38.00         PK           H      40.52     78.52           -26.18       2.13         90
       48.9        38.67         PK           V      40.52     79.19           -25.51       2.49         90
       63.14       42.30         PK           H      43.18     85.48           -19.22      10.58         90
       63.14       43.67         PK           V      43.18     86.85           -17.85      14.51         90
      120.96       44.58         PK           H      53.98     98.56           -12.16      53.77         90
      120.96       44.90         PK           V      53.98     98.88           -11.84      57.88         90
                                             Frequency: 62.64GHz
       50.12       39.14         PK           H      40.75     79.89           -24.81       2.92         90
       50.12       39.89         PK           V      40.75     80.64           -24.06       3.47         90
       80.65       44.12         PK           H      46.45     90.57           -14.13      34.16         90
       80.65       45.32         PK           V      46.45     91.77           -12.93      45.04         90
      125.28       43.02         PK           H      54.79     97.81           -12.91      45.24         90
      125.28       45.02         PK           V      54.79     99.81           -10.91      71.71         90

Note 1:




Note 2:The test distance is 1 m. for 40-90GHz, and 0.5m for 90-200GHz
Note 3:Corrected Amplitude = Meter Reading + Antenna Factor

Note 4: The Mixers and it`s RF cables is compose a system for calibration, the conversion factor was added into the
        test Spectrum Analyzer in testing.
Note 5:




      The Specified distance is 3m.


                                                                                                      Page 24 of 25


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RSH180530050-00B


§15.255(a) (h)– OPERATION RESTRICTION AND GROUP INSTALLTION
Applicable Standard
§15.255 (a) Operation under the provisions of this section is not permitted for the following products:
(1) Equipment used on aircraft or satellites.
(2) Field disturbance sensors, including vehicle radar systems, unless the field disturbance sensors are
employed for fixed operation. For the purposes of this section, the reference to fixed operation includes
field disturbance sensors installed in fixed equipment, even if the sensor itself moves within the equipment.

§15.255 (h) Any transmitter that has received the necessary FCC equipment authorization under the rules
of this chapter may be mounted in a group installation for simultaneous operation with one or more other
transmitter(s) that have received the necessary FCC equipment authorization, without any additional
equipment authorization. However, no transmitter operating under the provisions of this section may be
equipped with external phase-locking inputs that permit beam-forming arrays to be realized.


Result of Operation Restriction
The Manufacturer declared that the EUT will not be advertised or sold for use on aircraft or satellites. The
user manual includes a statement that cautions users that it is not permitted to use the product on aircraft or
satellites.


Result of Group installation
The frequency, amplitude and phase of the transmit sign al are set within the EUT. There are no external
phase-locking inputs or any other means of combining two or more units together to realize a beam-
forming array

                                      ***** END OF REPORT *****




                                                                                                  Page 25 of 25



Document Created: 2018-08-07 16:56:22
Document Modified: 2018-08-07 16:56:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC