FCC §1.1310 & §2.1091 –MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard

According to subpart §2.1091 and subpart §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                             (B) Limits for General Population/Uncontrolled Exposure

  Frequency Range              Electric Field           Magnetic Field        Power Density            Averaging Time
       (MHz)                  Strength (V/m)            Strength (A/m)          (mW/cm2)                 (minutes)

        0.3-1.34                    614                      1.63                 *(100)                     30
        1.34-30                    824/f                    2.19/f               *(180/f²)                   30
        30-300                     27.5                     0.073                   0.2                      30
       300-1500                      /                         /                  f/1500                     30
     1500-100,000                    /                         /                    1.0                      30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.

Calculated Formulary:
Predication of MPE limit at a given distance
S = PG/4πR² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is
normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);

For simultaneously transmit system, the calculated power density should comply with:




Calculated Data:

                                             Tune-up
            Frequency      Antenna Gain     Conducted Evaluation   Power    MPE
                                                                                                           MPE
 Mode         Range                           Power    Distance   Density   Limit
                                                                                                           ratio
              (MHz)                                      (cm)    (mW/cm2) (mW/cm2)
                          (dBi) (numeric) (dBm) (mW)
Bluetooth 2402-2480 0.00             1.00       7.00      5.01       50          0.0002          1.0      0.0002
           3652.5-
  LTE               17.00           50.12       16.50    44.67       50          0.0713          1.0      0.0713
            3697.5




FCC Part 90                                                                                                 Page 11 of 81


Bay Area Compliance Laboratories Corp.( Kunshan)                       Report No.: RSHA181115002-00C

Note: Bluetooth and LTE can transmit simultaneously; the worst condition is Bluetooth & LTE, as below:


                                 =0.0002+0.0713=0.0715 < 1.0


Result: The device meet FCC MPE at 50 cm distance.