MPE Report

FCC ID: 2ADZC-HLWH005

RF Exposure Info

Download: PDF
FCCID_3012640

                                                                              Shenzhen CTL Testing Technology Co., Ltd.
                                                                              Tel: +86-755-89486194 Fax: +86-755-26636041

                                                           MPE TEST REPORT
                                                  FCC Per 47 CFR 2.1091(b)
Report Reference No. ..................... :               CTL1602250473-WM
Compiled by
( position+printed name+signature) .. :                    File administrators Jennifer NI
Name of the organization performing
the tests                                                  Test Engineer Jacky Chen
( position+printed name+signature) .. :
Approved by
( position+printed name+signature) .. :                    Manager Tracy Qi
Date of issue ..................................... :      Mar.12, 2016
Test Firm.......................................... :      Shenzhen CTL Testing Technology Co., Ltd.
Address............................................. :     Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road,
                                                           Nanshan District, Shenzhen, China 518055
Applicant’s name ............................ :            Shenzhen Hollyland Technology Co.,Ltd
Address............................................. :     6/F, 3rd Bldg., 2nd South Zone, Honghualing Industrial Park,
                                                           No.1213 Liuxian Avenue, Xili Town, Nanshan District, Shenzhen,
                                                           China P.C.518055
Test specification:
Standard ........................................... :     FCC Per 47 CFR 2.1091(b)
TRF Originator .................................. :        Shenzhen CTL Testing Technology Co., Ltd.
Master TRF ....................................... :       Dated 2011-01
Shenzhen CTL Testing Technology Co., Ltd.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader’s interpretation of the reproduced material due to its
placement and context.
Test item description .................... :                   Wireless Video Transmission System
FCC ID…………………………….…..:                                         2ADZC-HLWH005
Trade Mark ....................................... :           N/A
Model/Type reference....................... :                  HLWH005
Modulation ....................................... :           OFDM 16QAM
Work Frequency Range.................... :                     5190MHz~5230MHz
                                                               5745MHz~5825MHz
Antenna Type ................................... :             External
Antenna Gain .................................... :            2.5dBi
Result................................................ :       Pass


V1.0                                 Page 2 of 7                   Report No.: CTL1602250473-WM


                                Test Report
                                                                                         Mar. 12, 2016
 Test Report No. :                CTL1602250473-WM              ______________________________________________________________________________________________


                                                                                         Date of issue


   Equipment under Test    :    Wireless Video Transmission System


   Type / Model(s)         :    HLWH005


   Applicant               :    Shenzhen Hollyland Technology Co.,Ltd


   Address                 :    6/F, 3rd Bldg., 2nd South Zone, Honghualing Industrial Park, No.1213
                                Liuxian Avenue, Xili Town, Nanshan District, Shenzhen, China
                                P.C.518055


   Manufacturer            :    Shenzhen Hollyland Technology Co.,Ltd


   Address                 :    6/F, 3rd Bldg., 2nd South Zone, Honghualing Industrial Park, No.1213
                                Liuxian Avenue, Xili Town, Nanshan District, Shenzhen, China
                                P.C.518055




 Test Result according to the                                   Pass
 standards on page 4:



   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test
   laboratory.


 V1.0                                  Page 3 of 7           Report No.: CTL1602250473-WM

                                            Content


1.      SUMMARY ............................................................................. 4

1.1.    EUT configuration                                                                   4
1.2.    Equipment Under Test                                                                4
1.3.    Description of the test mode                                                        4
1.4.    NOTE                                                                                4

2.      TEST ENVIRONMENT ............................................................... 4

2.1.    Address of the test laboratory                                                      5
2.2.    Environmental conditions                                                            5
2.3.    Statement of the measurement uncertainty                                            5

3.      METHOD OF MEASUREMENT ..................................................... 6


 V1.0                                       Page 4 of 7                 Report No.: CTL1602250473-WM

1. SUMMARY

1.1. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:

● - supplied by the manufacturer

o - supplied by the lab

● Battery                                    Manufacturer:    RUIBO
                                             Model:           NP- F960/F970
● AC adapter                                 Manufacturer:    winna
                                             Model:           YN12W-1200100UZ


1.2. Equipment Under Test

Power supply system utilised
  Power supply voltage                  :      120V / 60 Hz                  o 115V / 60Hz
                                              o 12 V DC                       o 24 V DC
                                               Other (specified in blank below)


                                             DC 7.4V from battery


1.3. Description of the test mode
Test Mode:

Test program used to control the EUT for staying in continuous transmitting mode is programmed.
Below Channels with highest data rate are chosen for full testing.
                 Test Mode(TM)          Description                    Remark
                        1              Transmitting                  5190 MHz
                        2              Transmitting                  5230 MHz
                        3              Transmitting                  5745 MHz
                        4              Transmitting                  5785 MHz
                        5              Transmitting                  5825 MHz


1.4. NOTE
  The EUT is a Wireless Video Transmission System,The functions of the EUT listed as below:

                                                   Test Standards                    Reference Report
                                               FCC Part 15 Subpart C
                                                                                   CTL1602250473-WF
                                                 (Section15.407)
 Wireless Video Transmission System
                                             FCC Per 47 CFR 2.1091(b)              CTL1602250473-WM


 V1.0                                     Page 5 of 7                  Report No.: CTL1602250473-WM

2. TEST ENVIRONMENT

2.1. Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055

The sites are constructed in conformance with the requirements of ANSI C6230, ANSI C63.10 (2013) and
CISPR Publication 22.


2.2. Environmental conditions

  During the measurement the environmental conditions were within the listed ranges:

                          Temperature:                               15-35 ° C

                          Humidity:                                   30-60 %

                          Atmospheric pressure:                    950-1050mbar



2.3. Statement of the measurement uncertainty

The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen CTL Testing Technology Co., Ltd. quality system acc.
to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested
may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
the device.

Hereafter the best measurement capability for CTL laboratory is reported:


                       Test                        Range               Measurement        Notes
                                                                        Uncertainty
            Radiated Emission                  30~1000MHz                 4.10dB            (1)
            Radiated Emission                  1~12.75GHz                 4.32dB            (1)
            Conducted Disturbance              0.15~30MHz                 3.22dB            (1)

          (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
              confidence level using a coverage factor of k=2.


 V1.0                                     Page 6 of 7                   Report No.: CTL1602250473-WM

3. Method of measurement

3.1. Applicable Standard
According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.


3.2. Limit
Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure




Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure




F=frequency in MHz
*=Plane-wave equivalent power density


3.3. MPE Calculation Method
Predication of MPE limit at a given distance
Equation from page 18 of OET Bulletin 65, Edition 97-01
S=PG/4πR²
Where: S=power density
P=power input to antenna
G=power gain of the antenna in the direction of interest relative to an isotropic radiator
R=distance to the center of radiation of the antenna
From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of
the used antenna is 2.5 dBi, the RF power density can be obtained.


 V1.0                                  Page 7 of 7                 Report No.: CTL1602250473-WM

TEST RESULTS
             Minimum                                                Power           Power
   Test                     Output       Output       Antenna
            Separation                                             Density         Density      Test
Frequency                   Power        Power         Gain
             Distance                                                Limit         At 20 cm    Results
  (MHz)                     (dBm)        (mW)        (Nemeric)
               (cm)                                               (mW/cm2)        (mW/cm2)
  5190        20.00         17.34         54.20       1.7783        1.000           0.0192      Pass
  5230        20.00         17.34         54.20       1.7783        1.000           0.0192      Pass
  5745        20.00         19.08         80.91       1.7783        1.000           0.0286      Pass
  5785        20.00         18.80         75.86       1.7783        1.000           0.0268      Pass
  5825        20.00         18.47         70.31       1.7783        1.000           0.0249      Pass


4.Conclusion
The measurement results comply with the FCC Limit per 47 CFR 2.1091 (b) for the controlled RF Exposure.



                      .....................End of Report.......................



Document Created: 2016-05-24 11:21:28
Document Modified: 2016-05-24 11:21:28

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC