MPE

FCC ID: 2ADZC-9802B

RF Exposure Info

Download: PDF
FCCID_4438300

                                     Shenzhen BCTC Testing Co., Ltd.



                               FCC ID:2ADZC-9802B

RF EXPOSURE EVALUATION
1. Introduction
According to FCC 1. 1310: The criteria listed in the following table shall be used to evaluate the
environment impact of human exposure to radio frequency(RF) Radiation as specified in
§1.1307(b), a device is defined as a transmitting device designed to be used in other than fixed
locations and to generally be used in such a way that a separation distance of at least 20 cm is
normally maintained between the transmitting antenna and the body of the user or nearby
persons. In this context, the term “fixed location” means that the device is physically secured at
one location and is not able to be easily moved to another location. Transmitting devices
designed to be used by consumers or workers that can be easily re-located, such as wireless
devic es associated with a personal computer, are considered to be mobile devices if they meet
the 20 cm separation requirement. The limits to be used for MPE evaluation are specified in
§1.1310. All unlicens ed personal communications service (P CS) devices and unlicensed NII
devic es shall be subject to the limits for general population/uncontrolled exposure.

2.RF Radiation Exposure Limits
According to 47 CFR §1.1310, the criteria listed in below table shall be used to evaluate the
environmental impact of human exposure to RF radiation as specified in §1.1307(b), except in the
case of portable devices which shall be evaluated according to the provisions of §2.1093.




Notes: 1. f = frequency in MHz 2. Occupational/cont rolled limits apply in situations in which
persons are exposed as a consequenc e of their employment provided those persons are fully
aware of the potential for expos ure and can exercise control over their exposure. Limits for
occupational/controlled exposure also apply in situations when an individual is transient through a
location where occupational/controlled limits apply provided they are made aware of the pot ential
for exposure. 3. General population/uncontrolled exposures apply in situations in which t he
general public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the pot ential for ex posure or cannot exercise control over
their exposure.


                                                    Shenzhen BCTC Testing Co., Ltd.


          3.MPE Assessment Method

          Calculations can be made to predict RF field strength and power density levels around typical RF
          sources. For example, in the case of a single radiating antenna, a prediction for power density in
          the far-field of the antenna can be made by use of the general Equations bel ow. This equation is
          generally accurate in the far-field of an ant enna but will over-predict power density in the near
          field, where they could be used for making a "worst case" or conservative prediction.




          Where
          S = Power Density, unit in mW/cm2
          P = Power input to the antenna, unit in mW
          G = Power gain of the antenna in the direction of interest relative to an isotropic radiator
          R = Distance to the center of radiation of the antenna, unit in cm
          EIRP = Effective isotropically radiated power

          4. MPE Calculation for Standalone Operations
          Operation Frequency: 5180-5240MHz, 5745-5825MHz
                                           2
          Power density limited: 1mW/ cm
          Antenna Type: External antenna
          Antenna A gain: 2dBi, Antenna B gain: 2 dBi, For MIMO mode for 802.11n20, GANT=[10log(GA+
          G B)] dbi =5.01dbi, Directional gain = GANT + 10 log(NA NT/NSS) dBi=8.02dbi
          R=20cm
          mW=10^(dBm/ 10)

                                                                                                                                         Power
Channe                 conducted   conducted                       Max                  Max             Antenna
                                                  Tune-up                                                         Ev aluation result    density
l Freq.   modulation     power       power                    tune-up power        tune-up power         Gain
                                                power (dBm)                                                          (mW/cm2 )           Limits
(MHz)                    (dBm)       (mW)                         (dBm)                (mW)             Numeric
                                                                                                                                       (mW/cm2)

           802.11n
 5180        20         18.65        73.28         18±1            19                 79.43              6.34        0.100166             1
           802.11n
 5200                   18.58        72.11         18±1            19                 79.43              6.34        0.100166             1
             20
           802.11n
 5240                   17.08        51.05         18±1            19                 79.43              6.34        0.100166             1
             20




                                                                                                                                         Power
Channe                 conducted   conducted                       Max                  Max             Antenna
                                                  Tune-up                                                         Ev aluation result    density
l Freq.   modulation     power       power                    tune-up power        tune-up power         Gain
                                                power (dBm)                                                          (mW/cm2 )           Limits
(MHz)                    (dBm)       (mW)                         (dBm)                (mW)             Numeric
                                                                                                                                       (mW/cm2)

           802.11n
 5745                   18.91        77.80         18±1            19                 79.43              6.34        0.100166             1
             20
           802.11n
 5785                   18.08        64.27         18±1            19                 79.43              6.34        0.100166             1
             20
           802.11n
 5825                   18.42        69.50         18±1            19                 79.43              6.34        0.100166             1
             20




          emission

                                   Pow er density Limits       Calculate Evaluation           Pow er density
                                       (mW/cm2 )                      result                      Limits
                                           Wifi                    (mW/cm2 )                    (mW/cm2)

                                        0.100166                        0.100166                    1


          Conclusion:


                                   Shenzhen BCTC Testing Co., Ltd.

For the max res ult : 0.100166≤ 1. 0, compliance with FCC's RF Exposure.
Summary: Since the ERP (effective radiated power) operated at < 1.5 GHz is less than 1.5 watts
and > 1.5 GHz is less than 3 watts, the routine environmental evaluation is not required, and the
MPE result calculated for this device complies with the MPE limit as specified in 47 CFR §1.1310.



Document Created: 2019-09-09 10:04:46