MPE Report

FCC ID: 2ADYL-JPD300EGS

RF Exposure Info

Download: PDF
FCCID_4175484

Report No. : EED32K00171708                                                 Page 1 of 7
1      COVER PAGE
            RF Exposure Evaluation Report
                   Product                  : Fetal Monitor
                   Trade mark               : JUMPER
                   Model/Type reference     : JPD-300E
                   Serial Number            : N/A
                   Report Number            : EED32K00171708
                   FCC ID                   : 2ADYL-JPD300EGS
                   Date of Issue            : Jan. 10, 2019
                                              47 CFR Part 1.1307
                                              47 CFR Part 2.1093
                   Test Standards           : KDB447498D01 General
                                              RF Exposure Guidance v06
                   Test result              : PASS



                                         Prepared for:
                 Shenzhen Jumper Medical Equipment Co., Ltd
             D Building, No. 71, Xintian Road, Fuyong Street, Baoan,
                          Shenzhen, Guangdong, China

                                         Prepared by:
                   Centre Testing International Group Co., Ltd.
                   Hongwei Industrial Zone, Bao’an 70 District,
                         Shenzhen, Guangdong, China
                            TEL: +86-755-3368 3668
                            FAX: +86-755-3368 3385



    Tested by:                                  Compiled by:

                              Peter                                Tom chen

    Reviewed by:                                Approved by:

                            Max Liang                             Kevin yang

    Date:                Jan. 10, 2019                               Check No.:3177469070


Report No. : EED32K00171708                         Page 2 of 7
2 Version
   Version No.           Date         Description
        00            Jan. 10, 2019     Original


Report No. : EED32K00171708                                                                                                                               Page 3 of 7
3         Contents
                                                                                                                                                                            Page
1 COVER PAGE.................................................................................................................................................................... 1

2 VERSION.............................................................................................................................................................................2

3 CONTENTS.........................................................................................................................................................................3

4 GENERAL INFORMATION..............................................................................................................................................4
    4.1 CLIENT INFORMATION...................................................................................................................................................4
    4.2 GENERAL DESCRIPTION OF EUT................................................................................................................................ 4
    4.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD.......................................................................................4
    4.4 TEST LOCATION............................................................................................................................................................ 5
    4.5 DEVIATION FROM STANDARDS.....................................................................................................................................5
    4.6 ABNORMALITIES FROM STANDARD CONDITIONS.........................................................................................................5
    4.7 OTHER INFORMATION REQUESTED BY THE CUSTOMER.............................................................................................5
5 SAR EVALUATION........................................................................................................................................................... 6
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT..............................................................................................................6
       5.1.1 Standard Requirement...................................................................................................................................... 6
       5.1.2 Limits.................................................................................................................................................................... 6
       5.1.3 EUT RF Exposure.............................................................................................................................................. 6
PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS.......................................................................................... 7


Report No. : EED32K00171708                                                              Page 4 of 7
4    General Information
4.1 Client Information
    Applicant:                    Shenzhen Jumper Medical Equipment Co., Ltd
                                  D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen,
    Address of Applicant:
                                  Guangdong, China
    Manufacturer:                 Shenzhen Jumper Medical Equipment Co., Ltd
                                  D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen,
    Address of Manufacturer:
                                  Guangdong, China
    Factory:                      Shenzhen Jumper Medical Equipment Co., Ltd
                                  D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen,
    Address of Factory:
                                  Guangdong, China

4.2 General Description of EUT
    Product Name:                Fetal Monitor
    Model No.(EUT):              JPD-300E
    Trade Mark:                  JUMPER
    EUT Supports Radios          BT 4.1 Single mode, 2402MHz-2480MHz
    application:

4.3 Product Specification subjective to this standard
    Frequency Range:             2402MHz-2480MHz
    Sample Type:                 Portable production
    Test power grade:            N/A
    Test software of EUT:        nRFgo Studio.exe(manufacturer declare)
    Antenna Type:                PCB Antenna
    Antenna Gain:                0dBi
    Power Supply:                Battery: 3.7V 190mAh
                                 -3.298dBm
    Conducted Peak Output
    Power:                       The Conducted Peak Output Power data refer to the report
                                 EED32K00171704
    Firmware version:            M1_V1.0(manufacturer declare )
    Hardware version:            V1.0(manufacturer declare )
    Test power grade:            N/A
    Test software of EUT:        nRFgo Studio.exe(manufacturer declare)
    Test Voltage:                Battery: 3.7V 190mAh
    Sample Received Date:        Jul. 02, 2018
    Sample tested Date:          Aug. 13, 2018 to Jan. 08, 2019
    The tested sample(s) and the sample information are provided by the client.


Report No. : EED32K00171708                                                          Page 5 of 7
4.4 Test Location
    All tests were performed at:
    Centre Testing International Group Co., Ltd
    Building C, Hongwei Industrial Park Block 70, Bao'an District, Shenzhen, China
    Telephone: +86 (0) 755 33683668     Fax:+86 (0) 755 33683385
    No tests were sub-contracted.
    FCC Designation No.: CN1164

4.5 Deviation from Standards
  None.

4.6 Abnormalities from Standard Conditions
  None.

4.7 Other Information Requested by the Customer
  None.


Report No. : EED32K00171708                                                                Page 6 of 7
5 SAR Evaluation
5.1 RF Exposure Compliance Requirement
5.1.1 Standard Requirement
     According to KDB447498D01 General RF Exposure Guidance v06
     Standalone SAR test exclusion considerations

     Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or
     body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or
     numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed
     below, is satisfied.
5.1.2 Limits
     The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
           f(GHz) is the RF channel transmit frequency in GHz
           Power and distance are rounded to the nearest mW and mm before calculation17
           The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion
5.1.3 EUT RF Exposure
     The Max Conducted Peak Output Power is -3.298dBm in highest channel(2.402GHz);
     The best case gain of the antenna is 0dBi.
     EIRP= -3.298dBm + 0dBi =-3.298dBm
     -3.298dBm logarithmic terms convert to numeric result is nearly0.468mW
      According to the formula. calculate the EIRP test result:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
      [√f(GHz)]
     General RF Exposure =( 0.468mW / 5 mm ) x √2.402GHz = 0.1451 ①
     SAR requirement:
     S= 3.0                                                               ②;
     ① < ②.

     So the SAR report is not required.


Report No. : EED32K00171708                                                             Page 7 of 7
                  PHOTOGRAPHS OF EUT Constructional Details
        Refer to Report No. EED32K00171704 for EUT external and internal photos.

                                         *** End of Report ***

The test report is effective only with both signature and specialized stamp, The result(s) shown in this
report refer only to the sample(s) tested. Without written approval of CTI, this report can’t be reproduced
except in full.



Document Created: 2019-01-23 13:31:34
Document Modified: 2019-01-23 13:31:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC