14_100501 TestRpt DCD r1

FCC ID: 2ADXG-SHOCK

Test Report

Download: PDF
FCCID_4237347

Report No.: SZAWW181224002-02             FCC ID: 2ADXG-SHOCK                 Page 1 of 31




                     FCC TEST REPORT

    Client Name         : VELVETWIRE LLC


                            1200 Pacific Ave, Suite 350, Santa Cruz, California,
    Address             :
                            United States 95060


    Product Name        : Stickershock


    Date                : Apr. 01, 2019




    Shenzhen Anbotek Compliance Laboratory Limited




                                                                        Code:AB-RF-05-a


Report No.: SZAWW181224002-02                                                    FCC ID: 2ADXG-SHOCK                                              Page 2 of 31

                                                                   Contents
1. General Information...............................................................................................................................................4
     1.1. Client Information....................................................................................................................................... 4
     1.2. Description of Device (EUT).....................................................................................................................4
     1.3. Auxiliary Equipment Used During Test................................................................................................... 4
     1.4. Description of Test Modes........................................................................................................................ 5
     1.5. Description Of Test Setup......................................................................................................................... 6
     1.6. Test Equipment List....................................................................................................................................7
     1.7. Measurement Uncertainty.........................................................................................................................8
     1.8. Description of Test Facility........................................................................................................................ 8
2. Summary of Test Results..................................................................................................................................... 9
3. Conducted Emission Test...................................................................................................................................10
     3.1. Test Standard and Limit.......................................................................................................................... 10
     3.2. Test Setup..................................................................................................................................................10
     3.3. Test Procedure..........................................................................................................................................10
     3.4. Test Data....................................................................................................................................................10
4. Radiation Spurious Emission and Band Edge................................................................................................15
     4.1. Test Standard and Limit.......................................................................................................................... 15
     4.2. Test Setup..................................................................................................................................................15
     4.3. Test Procedure..........................................................................................................................................16
     4.4. Test Data....................................................................................................................................................17
5. Antenna Requirement......................................................................................................................................... 23
     5.1. Test Standard and Requirement............................................................................................................23
     5.2. Antenna Connected Construction..........................................................................................................23
APPENDIX I -- TEST SETUP PHOTOGRAPH...................................................................................................24
APPENDIX II -- EXTERNAL PHOTOGRAPH..................................................................................................... 26
APPENDIX III -- INTERNAL PHOTOGRAPH..................................................................................................... 29




                                                                                                                                        Code:AB-RF-05-a


Anbotek EYJET .\
Product Safety      Anbotek Testing

     Report No.: SZAWW181224002—02                                  FCC ID: 2ADXG—SHOCK                              Page 3 of 31




     Applicant                    : VELVETWIRELLC
     Manufacturer                 ‘_ShenZhen Tailhoo Technology Co., Ltd.

     Product Name                 ‘_ Stickershock

     Model No.                    *    100501

     Trade Mark                   :    Velvetwire®

     Rating(s)                    _ Input: DC 5V, 225mA(with DC 3.75V, 180mAh battery inside)



     Test Standard(s)             :    FCC Part15 Subpart C 2018, Paragraph 15.209
     Test Method(s)               *‘   ANSIC63.10: 2013


     The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to
     determine the maximum emission levels emanating from the device and the severe levels of the device
     can endure and its performance criterion. The measurement results are contained in this test report and
     Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy
     and completeness of these measurements. Also, this report shows that the EUT (Equipment Under
     Test) is technically compliant with the FCC Part 15 Subpart C requirements.

     This report applies to above tested sample only and shall not be reproduced in part without written
     approval of Shenzhen Anbotek Compliance Laboratory Limited.

     Date of Receipt                                                                   Dec. 25, 2018
     Date of Test                                                          Dec. 25, 2018~Apr. 01, 2019
                                                                                         )     *

                                                                                     dflfl           @4
     Prepared By                                                                         DJ        \
                                                                              (Engineer / Oliay Yang)


                                                                                       5:%1/?) Me‘}
     Reviewer
                                                                            (Supervisor / Snowy Meng)

                                                                                        |
                                                                                 :5%1{ Z4
     Approved & Authorized Signer
                                                                              (Manager / Sally Zhang)


Shenzhen Anbotek Compliance Laboratory Limited                                                           Code:AB—RF—05—a
Address: 1/F, Building:—D, Sogood Science and ' echnology F—"'r‘/i"m SanweiCommunity                    {/} ‘ri—i':;).r‘lm"?:   ks
          a St          an   Di             hen.   G:t   dong. China.                                     J’/ 400—003—0500

                                                         Email:service@anbotek.com                      www.anbotek.com


Report No.: SZAWW181224002-02                     FCC ID: 2ADXG-SHOCK                    Page 4 of 31

1. General Information
1.1. Client Information

Applicant             :   VELVETWIRE LLC

Address               :   1200 Pacific Ave, Suite 350, Santa Cruz, California, United States 95060

Manufacturer          :   ShenZhen Tailhoo Technology Co., Ltd.

                          Floor 1&2, Building 5, Tang East, Honggang industrial area, Baoan,
Address               :
                          Shenzhen
Factory               :   ShenZhen Tailhoo Technology Co., Ltd.

                          Floor 1&2, Building 5, Tang East, Honggang industrial area, Baoan,
Address               :
                          Shenzhen


1.2. Description of Device (EUT)
Product Name          :   Stickershock
Model No.             :   100501
Trade Mark            :   Velvetwire®
Test Power Supply     :   AC 240V, 60Hz for adapter/ AC 120V, 60Hz for adapter
Test Sample No.       :   S1(Normal Sample), S2(Engineering Sample)
                          Operation Frequency:           111~205KHz

Product                   Modulation Type:               MSK
                      :
Description               Antenna Type:                  Inductive loop coil Antenna
                          Antenna Gain(Peak):            0 dBi
Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications
           or the User’s Manual.


1.3. Auxiliary Equipment Used During Test
                      Manufacturer: ZTE
                      M/N: STC-A2050I1000USBA-C
Adapter           :   S/N: 201202102100876
                      Input: 100-240V~ 50/60Hz, 0.3A
                      Output: DC 5V, 1000mA




                                                                                   Code:AB-RF-05-a


Report No.: SZAWW181224002-02                       FCC ID: 2ADXG-SHOCK                      Page 5 of 31
1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was
pre-scanning tested base on the consideration of following EUT operation mode or test configuration
mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test
configuration mode(s) mentioned above was evaluated respectively.


             Pretest Mode                                      Description
                Mode 1                             Full load, wireless charger module


                                         For Conducted Emission
            Final Test Mode                                    Description
                Mode 1                             Full load, wireless charger module


                                          For Radiated Emission
            Final Test Mode                                    Description
                Mode 1                             Full load, wireless charger module



Note: (1)Test channel is 0.1360MHz.
     (2) All the situation(full load, half load and empty load) has been tested,only the worst situation
        (full load) was recorded in the report.




                                                                                        Code:AB-RF-05-a


Report No.: SZAWW181224002-02            FCC ID: 2ADXG-SHOCK             Page 6 of 31
1.5. Description Of Test Setup



  CE
                                                   USB


                                                                   AC Line
                                         E-1               E-2
                                         EUT             Adapter             LISN


0.8m




         Table
        Table

                                 1.5m




  RE

                                   USB


                                                                   AC Line
                           E-1                   E-2
                           EUT                 Adapter

 0.8m




         Table
        Table

                                 1.5m




                                                                    Code:AB-RF-05-a


Report No.: SZAWW181224002-02                  FCC ID: 2ADXG-SHOCK                    Page 7 of 31
1.6. Test Equipment List
                                                                                             Cal.
Item       Equipment         Manufacturer      Model No.      Serial No.      Last Cal.
                                                                                            Interval
            L.I.S.N.
 1.      Artificial Mains   Rohde & Schwarz     ENV216         100055       Nov. 05, 2018   1 Year
            Network
 2.    EMI Test Receiver    Rohde & Schwarz     ESPI3          101604       Nov. 05, 2018   1 Year
                              Compliance
 3.     RF Switching Unit                      RSU-M2          38303        Nov. 05, 2018   1 Year
                               Direction
 4.    Spectrum Analysis        Agilent         E4407B       US39390582     Nov. 05, 2018   1 Year
         MAX Spectrum
 5.                             Agilent         N9020A       MY51170037     Nov. 05, 2018   1 Year
            Analysis
                                              BK1G18G30
 6.       Preamplifier      SKET Electronic                   KD17503       Nov. 05, 2018   1 Year
                                                  D
       Double Ridged Horn     Instruments
 7.                                            GTH-0118        351600       Nov. 19, 2018   1 Year
            Antenna           corporation
        Bilog Broadband
 8.                          Schwarzbeck      VULB9163      VULB 9163-289   Nov. 19, 2018   1 Year
            Antenna
 9.      Loop Antenna        Schwarzbeck      FMZB1519B        00053        Nov. 19, 2018   1 Year
                                              LB-180400-K
 10.     Horn Antenna           A-INFO                       J211060628     Nov. 20, 2018   1 Year
                                                  F
 11.      Pre-amplifier        SONOMA            310N          186860       Nov. 05, 2018   1 Year
       EMI Test Software
 12.                           SHURPLE           N/A             N/A            N/A          N/A
            EZ-EMC
         RF Test Control
 13.                           YIHENG           YH3000        2017430       Nov. 05, 2018   1 Year
            System
 14.     Power Sensor           DAER          RPR3006W      15I00041SN045   Nov. 05, 2018   1 Year

 15.     Power Sensor           DAER          RPR3006W      15I00041SN046   Nov. 05, 2018   1 Year
         MXA Spectrum
 16.                            Agilent         N9020A       MY51170037     Nov. 05, 2018   1 Year
            Analysis
         MXG RF Vector
 17.                            Agilent         N5182A       MY48180656     Nov. 05, 2018   1 Year
        Signal Generator
 18.    Signal Generator        Agilent         E4421B       MY41000743     Nov. 05, 2018   1 Year

 19.    DC Power Supply        IVYTECH          IV3605      1804D360510     Apr. 02, 2018   1 Year
            Constant
                                              ZJ-KHWS80
 20.      Temperature         ZHONGJIAN                          N/A        Nov. 01, 2018   1 Year
                                                  B
       Humidity Chamber



                                                                              Code:AB-RF-05-a


Report No.: SZAWW181224002-02                        FCC ID: 2ADXG-SHOCK                         Page 8 of 31
1.7. Measurement Uncertainty
 Radiation Uncertainty             :   Ur = 3.9 dB (Horizontal)
                                       Ur = 3.8 dB (Vertical)


 Conduction Uncertainty            :   Uc = 3.4 dB



1.8. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
from the FCC is maintained in our files. Registration No. 184111, July 31, 2017.

ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully
described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The
acceptance letter from the ISED is maintained in our files. Registration 8058A-1, June 13, 2016.



Test Location
Shenzhen Anbotek Compliance Laboratory Limited.
1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an
District, Shenzhen, Guangdong, China.518102




                                                                                            Code:AB-RF-05-a


Report No.: SZAWW181224002-02        FCC ID: 2ADXG-SHOCK          Page 9 of 31

2. Summary of Test Results
         Standard Section                Test Item              Result

   FCC Part 15, Paragraph 15.207   Conducted Emission Test      PASS
      FCC Part 15, Paragraph
                                      Spurious Emission         PASS
           15.209(a)(f)
             Part 15.203             Antenna Requirement        PASS




                                                             Code:AB-RF-05-a


Report No.: SZAWW181224002-02                            FCC ID: 2ADXG-SHOCK                     Page 10 of 31

3. Conducted Emission Test
3.1. Test Standard and Limit
 Test Standard           FCC Part15 Section 15.207
                                                                  Maximum RF Line Voltage (dBuV)
                                Frequency
                                                          Quasi-peak Level             Average Level
 Test Limit                  150kHz~500kHz                    66 ~ 56 *                  56 ~ 46 *
                              500kHz~5MHz                         56                        46
                              5MHz~30MHz                          60                        50

 Remark: (1) *Decreasing linearly with logarithm of the frequency.
              (2) The lower limit shall apply at the transition frequency.



3.2. Test Setup




3.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network
(L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block
diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum
conducted emission. In order to find the maximum emission levels, the relative positions of equipment
and all of the interface cables shall be changed according to FCC ANSI C63.10-2013 on Conducted
Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.

3.4. Test Data
Please to see the following pages


                                                                                         Code:AB-RF-05-a


Report No.: SZAWW181224002-02               FCC ID: 2ADXG-SHOCK        Page 11 of 31
Conducted Emission Test Data
Test Site:               1# Shielded Room
Operating Condition:     Mode 1
Test Specification:      AC 240V, 60Hz for adapter
Comment:                 Live Line
                         Tem.: 24.3℃ Hum.: 58%




                                                                  Code:AB-RF-05-a


Report No.: SZAWW181224002-02               FCC ID: 2ADXG-SHOCK        Page 12 of 31
Conducted Emission Test Data
Test Site:               1# Shielded Room
Operating Condition:     Mode 1
Test Specification:      AC 240V, 60Hz for adapter
Comment:                 Neutral Line
                         Tem.: 24.3℃ Hum.: 58%




                                                                  Code:AB-RF-05-a


Report No.: SZAWW181224002-02               FCC ID: 2ADXG-SHOCK        Page 13 of 31
Conducted Emission Test Data
Test Site:               1# Shielded Room
Operating Condition:     Mode 1
Test Specification:      AC 120V, 60Hz for adapter
Comment:                 Live Line
                         Tem.: 24.3℃ Hum.: 58%




                                                                  Code:AB-RF-05-a


Report No.: SZAWW181224002-02               FCC ID: 2ADXG-SHOCK        Page 14 of 31
Conducted Emission Test Data
Test Site:               1# Shielded Room
Operating Condition:     Mode 1
Test Specification:      AC 120V, 60Hz for adapter
Comment:                 Neutral Line
                         Tem.: 24.3℃ Hum.: 58%




                                                                  Code:AB-RF-05-a


Report No.: SZAWW181224002-02                             FCC ID: 2ADXG-SHOCK                 Page 15 of 31

4. Radiation Spurious Emission and Band Edge
4.1. Test Standard and Limit
Test Standard FCC Part15 C Section 15.209 and 15.205
                        Frequency              Field strength        Limit                    Measurement
                                                                                 Remark
                          (MHz)              (microvolt/meter)     (dBuV/m)                   distance (m)
                  0.009MHz~0.490MHz             2400/F(kHz)            -             -            300

                  0.490MHz-1.705MHz            24000/F(kHz)            -             -             30

                    1.705MHz-30MHz                   30                -            -              30

Test Limit           30MHz~88MHz                    100              40.0       Quasi-peak         3

                     88MHz~216MHz                   150              43.5       Quasi-peak         3

                    216MHz~960MHz                   200              46.0       Quasi-peak         3

                   960MHz~1000MHz                   500              54.0       Quasi-peak         3

                                                    500              54.0        Average           3
                     Above 1000MHz
                                                      -              74.0         Peak             3
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the
maximum permitted average emission limit applicable to the equipment under test. This peak limit applies to
the total peak emission level radiated by the device.


4.2. Test Setup




                                            Figure 1. Below 30MHz


                                                                                         Code:AB-RF-05-a


Report No.: SZAWW181224002-02                    FCC ID: 2ADXG-SHOCK                    Page 16 of 31




                                      Figure 2. 30MHz to 1GHz




                                       Figure 3. Above 1 GHz


4.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The
EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The
antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Rotated
the EUT through three orthogonal axes to determine the maximum emissions, both horizontal and
vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6 Chamber. The device is
evaluated in xyz orientation.

                                                                                  Code:AB-RF-05-a


Report No.: SZAWW181224002-02                  FCC ID: 2ADXG-SHOCK             Page 17 of 31
For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.


4.4. Test Data
PASS

Note: The data is in TX mode, and this is the worst mode.




                                                                          Code:AB-RF-05-a


Report No.: SZAWW181224002-02                   FCC ID: 2ADXG-SHOCK                     Page 18 of 31
Test Results
(Between 9KHz – 30MHz)
Job No.:            SZAWW181224002-02
Standard:           FCC PART15 C _3m        Power Source:              AC 120V, 60Hz for adapter
Test item:          Radiation Test          Temp.(C)/Hum.(%RH):        24.7℃/51%RH
Test Mode:          Mode 1                  Distance:                  3m




Remark:According to FCC PART 15.209 (d), the emission limits for the frequency bands 9–90 kHz, 110–490
kHz and above 1000 MHz, Radiated emission limits in these three bands are based on measurements
employing an average detector.




                                                                                 Code:AB-RF-05-a


Report No.: SZAWW181224002-02       FCC ID: 2ADXG-SHOCK             Page 19 of 31
(Between 30MHz –1000 MHz)


Job No.:        SZAWW181224002-02   Polarization:         Horizontal
Standard:       FCC PART15 C _3m    Power Source:         AC 120V, 60Hz for adapter
Test item:      Radiation Test      Temp.(C)/Hum.(%RH):   24.3℃/55%RH
Test Mode:      Mode 1              Distance:             3m




                                                               Code:AB-RF-05-a


Report No.: SZAWW181224002-02       FCC ID: 2ADXG-SHOCK                Page 20 of 31



Job No.:        SZAWW181224002-02     Polarization:         Vertical
Standard:       FCC PART15 C _3m      Power Source:         AC 120V, 60Hz for adapter
Test item:      Radiation Test        Temp.(C)/Hum.(%RH):   24.3℃/55%RH
Test Mode:      Mode 1                Distance:             3m




                                                                 Code:AB-RF-05-a


Report No.: SZAWW181224002-02       FCC ID: 2ADXG-SHOCK             Page 21 of 31

Job No.:        SZAWW181224002-02   Polarization:         Horizontal
Standard:       FCC PART15 C _3m    Power Source:         AC 240V, 60Hz for adapter
Test item:      Radiation Test      Temp.(C)/Hum.(%RH):   24.3℃/55%RH
Test Mode:      Mode 1              Distance:             3m




                                                               Code:AB-RF-05-a


Report No.: SZAWW181224002-02       FCC ID: 2ADXG-SHOCK                Page 22 of 31



Job No.:        SZAWW181224002-02     Polarization:         Vertical
Standard:       FCC PART15 C _3m      Power Source:         AC 240V, 60Hz for adapter
Test item:      Radiation Test        Temp.(C)/Hum.(%RH):   24.3℃/55%RH
Test Mode:      Mode 1                Distance:             3m




                                                                 Code:AB-RF-05-a


Report No.: SZAWW181224002-02                      FCC ID: 2ADXG-SHOCK                        Page 23 of 31

5. Antenna Requirement
5.1. Test Standard and Requirement
Test Standard     FCC Part15 Section 15.203
                  An intentional radiator shall be designed to ensure that no antenna other than that
                  furnished by the responsible party shall be used with the device. The use of a
                  permanently attached antenna or of an antenna that uses a unique coupling to the
Requirement
                  intentional radiator, the manufacturer may design the unit so that a broken antenna can
                  be replaced by the user, but the use of a standard antenna jack or electrical connector is
                  prohibited.


5.2. Antenna Connected Construction
The antenna is a Inductive loop coil Antenna which permanently attached, and the best case gain of the
antenna is 0 dBi. It complies with the standard requirement.



                                                                                Antenna




                                                                                       Code:AB-RF-05-a


Report No.: SZAWW181224002-02                 FCC ID: 2ADXG-SHOCK        Page 24 of 31

APPENDIX I -- TEST SETUP PHOTOGRAPH
                        Photo of Conducted Emission Measurement




                                Photo of Radiation Emission Test




                                                                    Code:AB-RF-05-a


Anbotek K=qHTtp]]
Product Safety       Anbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building—D, Sogood—Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street; Bac‘an District, Shenzhen, Guangdong, China.                   2
                                                                                   400—003—0500
Tel:(86)755—26066440.—~—   Fax:(86)755—26014772   Email:service@anbotek.com      www.anbotek.com


Report No.: SZAWW181224002-02   FCC ID: 2ADXG-SHOCK        Page 26 of 31

APPENDIX II -- EXTERNAL PHOTOGRAPH




                                                      Code:AB-RF-05-a


Anbotek B2 ET F¢]]
eb eELG4)          Anbotek Testing




                            0O 1 2 3 4                                    5 6 17    2




                                                      \
                                 0           1 2 3 4A 5 G

Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,    @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                      °/ 400—003—0500
Tel:(86)755—26066440        Fax:(86)755—26014772    Email:service @anbotek.com     www.anbotek.com


Anbotek B2 ET F¢]]
eb eELG4)          Anbotek Testing




                                                                                      \




                                                                                  \       Y\        S

                  Ww               )           j        2         3          4    5       G

Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                  °/ 400—003—0500
Tel:(86)755—26066440        Fax:(86)755—26014772    Email:service @anbotek.com                 www.anbotek.com


Report No.: SZAWW181224002-02   FCC ID: 2ADXG-SHOCK        Page 29 of 31

APPENDIX III -- INTERNAL PHOTOGRAPH




                                                      Code:AB-RF-05-a


Anbotek B2 ET F¢]]
eb e ELG4)           Anbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street; Bac‘an District, Shenzhen, Guangdong, China.                   °/ 400—003—0500
Tel:(86)755—26066440.—~—   Fax:(86)755—26014772   Email:service@anbotek.com      www.anbotek.com


Anbotek B2 ET F¢]]
AooratseiiP        Anbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                     °/ 400—003—0500
Tel:(86)755—26066440        Fax:(86)755—26014772    Email:service @anbotek.com    www.anbotek.com



Document Created: 2019-04-13 01:26:40
Document Modified: 2019-04-13 01:26:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC