Test Report

FCC ID: 2ADXC18IR388

Test Report

Download: PDF
FCCID_4086172

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA




                                                 FCC TEST REPORT
                                                               FOR
                                Shenzhen Lenkeng Technology Co., Ltd
                                            IR signal wireless extender
                                               Test Model: LKV388IR-915
                      Additional Model No.: LKV388IR-909, LKV388IR-921




 Prepared for                              : Shenzhen Lenkeng Technology Co., Ltd
 Address                                   : West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
                                             Shenzhen 518049, China

 Prepared by                               : Shenzhen LCS Compliance Testing Laboratory Ltd.
                                             1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
 Address                                   :
                                             Bao'an District, Shenzhen, Guangdong, China
 Tel                                       : (+86)755-82591330
 Fax                                       : (+86)755-82591332
 Web                                       : www.LCS-cert.com
 Mail                                      : webmaster@LCS-cert.com

 Date of receipt of test sample            :   May 25, 2018
 Number of tested samples                  :   1
 Sample number                             :   Prototype
Date of Test                               :   May 25, 2018~November 20, 2018
 Date of Report                            :   November 21, 2018




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 1 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2ADXC18IR388          Report No.: LCS180525011AEA


                                                      FCC TEST REPORT
                                                 FCC CFR 47 PART 15 C(15.249)
Report Reference No. ................. : LCS180525011AEA

Date of Issue ................................... : November 21, 2018

Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                        1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
Address ........................................... :
                                                        Bao'an District, Shenzhen, Guangdong, China
                                                        Full application of Harmonised standards ■
                                                    :
Testing Location/ Procedure...........                  Partial application of Harmonised standards □
                                                        Other standard testing method □
Applicant’s Name.......................... : Shenzhen Lenkeng Technology Co., Ltd
                                                        West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
Address ........................................... :
                                                        Shenzhen 518049, China

Test Specification

Standard ......................................... : FCC CFR 47 PART 15 C(15.249) / ANSI C63.10: 2013

Test Report Form No. ..................... : LCSEMC-1.0

TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF ..................................... : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
Test Item Description. .................. : IR signal wireless extender

Trade Mark...................................... : LENKENG

Test Model ...................................... : LKV388IR-915
Ratings ............................................ : DC 5V/100mA by Power adapter or PC USB port
Result ........................................... : Positive



             Compiled by:                                       Supervised by:                             Approved by:




   Calvin Weng/ Administrators                            Leo Lee/ Technique principal                Gavin Liang/ Manager




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2ADXC18IR388           Report No.: LCS180525011AEA


                                                      FCC -- TEST REPORT


                                                                                               November 21, 2018
       Test Report No. :                            LCS180525011AEA                              Date of issue




    Test Model..............................         : LKV388IR-915

    EUT.........................................     : IR signal wireless extender

    Applicant...............................         : Shenzhen Lenkeng Technology Co., Ltd
                                                       West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
    Address..................................        :
                                                       Shenzhen 518049, China
    Telephone...............................         : /
    Fax..........................................    : /

    Manufacturer........................             : Shenzhen Lenkeng Technology Co., Ltd
                                                       West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
    Address...................................       :
                                                       Shenzhen 518049, China
    Telephone...............................         : /
    Fax..........................................    : /

    Factory...................................       : Shenzhen Lenkeng Technology Co., Ltd
                                                       West 4F,Jinguangxia Culture&Tech Park, 3 Guangxia Road,
    Address...................................       :
                                                       Shenzhen 518049, China
    Telephone...............................         : /
    Fax..........................................    : /




                             Test Result                                                     Positive


   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test
   laboratory.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 3 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


                                                    Revision History
        Revision                       Issue Date                            Revisions                        Revised By
          000                       November 21, 2018                       Initial Issue                     Gavin Liang




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 4 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                              FCC ID: 2ADXC18IR388                Report No.: LCS180525011AEA


                                                  TABLE OF CONTENTS

    1. GENERAL INFORMATION .................................................................................................... 6
        1.1 Description of Device (EUT) ......................................................................................................... 6
        1.2 Support equipment List................................................................................................................. 6
        1.3 External I/O .................................................................................................................................. 6
        1.4 Description of Test Facility ........................................................................................................... 6
        1.5. Statement of the measurement uncertainty ................................................................................. 7
        1.6. Measurement Uncertainty ........................................................................................................... 7
        1.7 Description of Test Modes ............................................................................................................ 7
    2. TEST METHODOLOGY ......................................................................................................... 8
        2.1. EUT Configuration ....................................................................................................................... 8
        2.2. EUT Exercise .............................................................................................................................. 8
        2.3. General Test Procedures ............................................................................................................ 8
    3. CONNECTION DIAGRAM OF TEST SYSTEM ...................................................................... 9
        3.1. Justification ................................................................................................................................. 9
        3.2. EUT Exercise Software ............................................................................................................... 9
        3.3. Special Accessories .................................................................................................................... 9
        3.4. Block Diagram/Schematics .......................................................................................................... 9
        3.5. Equipment Modifications ............................................................................................................. 9
        3.6. Test Setup ................................................................................................................................... 9
    4. SUMMARY OF TEST RESULTS .......................................................................................... 10
    5. ANTENNA REQUIREMENT ................................................................................................. 11
    6. POWER LINE CONDUCTED EMISSIONS........................................................................... 12
    7. RADIATED EMISSION MEASUREMENT ............................................................................ 14
    8. RESULTS FOR BAND EDGE TESTING .............................................................................. 24
    9. 99% OCCUPIED BANDWIDTH AND 20 DB BANDWIDTH MEASUREMENT .................... 28
    10. LIST OF MEASURING EQUIPMENT ................................................................................. 30
    11. TEST SETUP PHOTOGRAPHS OF THE EUT ................................................................... 31
    12. EXTERIOR PHOTOGRAPHS OF THE EUT ...................................................................... 31
    13. INTERIOR PHOTOGRAPHS OF THE EUT........................................................................ 31




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 5 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


     1. GENERAL INFORMATION

   1.1 Description of Device (EUT)

       EUT                               : IR signal wireless extender
       Model Number                      : LKV388IR-915

       Additional Model Number : LKV388IR-909, LKV388IR-921

                                           All the PCB and PCB components are identical with each other,
       Model Declaration                 : except the model name is different, so no additional models are
                                           tested.
       Power Supply                      : DC 5V/100mA by Power adapter or PC USB port
       Frequency Range                   : 909MHz-921MHz(909MHz, 915 MHz, 921MHz)
       Modulation Technology             : ASK
       Channel Number                    : 3 channels
       Antenna Gain                      : External antenna, 0dBi (Max.)


   1.2 Support equipment List

            Manufacturer               Description                    Model               Serial Number        Certificate
           MASS POWER                Power Adapter           NBS05B050100VU                       --           FCC VOC


   1.3 External I/O

               I/O Port Description                          Quantity                              Cable
                    DC in port                                 1                            1.6m unshielded cable
                    IR in port                                 1                             1m unshielded cable


   1.4 Description of Test Facility

     FCC Registration Number. is 254912.
     Industry Canada Registration Number. is 9642A-1.
     ESMD Registration Number. is ARCB0108.
     UL Registration Number. is 100571-492.
     TUV SUD Registration Number. is SCN1081.
     TUV RH Registration Number. is UA 50296516-001
     The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and CISPR
     16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 6 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


   1.5. Statement of the measurement uncertainty

     The data and results referenced in this document are true and accurate. The reader is cautioned that
     there may be errors within the calibration limits of the equipment and facilities. The measurement
     uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
     “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
     Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN
     ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
     result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
     the device.

   1.6. Measurement Uncertainty

                    Test Item                       Frequency Range                      Uncertainty                Note
                                                      9KHz~30MHz                          ±3.10dB                    (1)
                                                    30MHz~200MHz                          ±2.96dB                    (1)
            Radiation Uncertainty           :      200MHz~1000MHz                         ±3.10dB                    (1)
                                                     1GHz~26.5GHz                         ±3.80dB                    (1)
                                                    26.5GHz~40GHz                         ±3.90dB                    (1)
           Conduction Uncertainty :                  150kHz~30MHz                         ±1.63dB                    (1)
             Power disturbance    :                 30MHz~300MHz                          ±1.60dB                    (1)
     (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95%
     confidence level using a coverage factor of k=2.

   1.7 Description of Test Modes

     The following operating modes were applied for the related test items.
     All test modes were tested, only the result of the worst case was recorded in the report.

                         Mode of Operations                             Frequency Range (MHz)
                               ASK                                           909, 915, 921
                                                   For Conducted Emission
                               Test Mode                                                  TX Mode
                                                    For Radiated Emission
                               Test Mode                                                  TX Mode


     Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was the
     mode and channel with the highest output power that was determined to be TX-915MHz.
     Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was determined to be
     TX-915MHz.
     ***Note: Using a temporary antenna connector for the EUT when conducted measurements are
     performed.
     Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worst
     case.
     Pre-test AC conducted emission at both power adapter and charge from PC mode, recorded worst
     case.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA



2. TEST METHODOLOGY
     All measurements contained in this report were conducted with ANSI C63.10: 2013, American
     National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
     The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
     conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory
     Ltd.

   2.1. EUT Configuration
     The EUT configuration for testing is installed on RF field strength measurement to meet the
     Commissions requirement and operating in a manner that intends to maximize its emission
     characteristics in a continuous normal application.

   2.2. EUT Exercise
     The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of
     the measurements.
     According to its specifications, the EUT must comply with the requirements of the Section 15.203,
     15.205, 15.207, 15.209 and 15.249 under the FCC Rules Part 15 Subpart C.

   2.3. General Test Procedures

   1.1.1.2.3.1 Conducted Emissions

     The EUT is directly placed on the ground. According to the requirements in Section 6.2.1 of ANSI
     C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15
     MHz and 30MHz using Quasi-peak and average detector modes.

   1.1.2.2.3.2 Radiated Emissions

     The EUT is placed on a turntable, which is directly placed on the ground. The turntable shall rotate
     360 degrees to determine the position of maximum emission level. EUT is set 3m away from the
     receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each
     emission was to be maximized by changing the polarization of receiving antenna both horizontal and
     vertical. In order to find out the maximum emissions, exploratory radiated emission measurements
     were made according to the requirements in Section 6.3 of ANSI C63.10-2013




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 8 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA



3. CONNECTION DIAGRAM OF TEST SYSTEM

   3.1. Justification
      The system was configured for testing in a continuous transmit condition. Continuous transmitting was
      pre-programmed. It’ll keep transmitting with modulated signal at the lowest channel when powered
      on. When press the "Lock ID" button, it'll move to the middle channel. Repeat press it again, it'll trans
      mitting at the high channel used.

   3.2. EUT Exercise Software
      It'll move to the middle channel. Repeat press it again, it'll transmitting at the high channel used.

   3.3. Special Accessories

                                                                                                          shielded/
  No.     Equipment              Manufacturer         Model No.          Serial No.          Length                        Notes
                                                                                                          unshielded
  1       PC                     Lenovo               Ideapad            A131101550          /            /                DOC
  2       Power adapter          Lenovo               CPA-A090           36200414            1.00m        unshielded       DOC

   3.4. Block Diagram/Schematics
      Please refer to the related document

   3.5. Equipment Modifications
      Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

   3.6. Test Setup
      Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 9 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA



4. SUMMARY OF TEST RESULTS

                                 Applied Standard: FCC Part 15 Subpart C §15.249
                          FCC Rules                                           Description Of Test                      Result
                           §15.203                                           Antenna Requirement                      Compliant
                          §15.207(a)                                 Power Line Conducted Emissions                   Compliant
   §15.205(a), §15.209(a), §15.249(a), §15.249(c)                    Radiated Emissions Measurement                   Compliant
                          §15.249 (d)                                     Band Edges Measurement                      Compliant
                            §2.1049                                       99% and 20 dB Bandwidth                     Compliant




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 10 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


5. ANTENNA REQUIREMENT

5.1. Standard Applicable
     According to § 15.203 and RSS-Gen, an intentional radiator shall be designed to ensure that no
     antenna other than that furnished by the responsible party shall be used with the device. The use of a
     permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator
     shall be considered sufficient to comply with the provisions of this section. The manufacturer may
     design the unit so that a broken antenna can be replaced by the user, but the use of a standard
     antenna jack or electrical connector is prohibited.

5.2. Antenna Connected Construction
     The EUT use external R-SMA antenna and maximum antenna gain is 0dBi, meets FCC Part §15.203
     antenna requirement. Please see EUT photo for details.

5.3. Results
     Compliance




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 11 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


6. POWER LINE CONDUCTED EMISSIONS

6.1. Standard Applicable
       According to §15.207 (a) & RSS-Gen § 8.8: For an intentional radiator which is designed to be
       connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto
       the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not
       exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range
       0.15 MHz to 0.50 MHz). The limits at specific frequency range are listed as follows:

                         Frequency Range                                      Limits (dBμV)
                               (MHz)                          Quasi-peak                        Average
                            0.15 to 0.50                       66 to 56                         56 to 46
                             0.50 to 5                            56                               46
                              5 to 30                             60                               50

                 * Decreasing linearly with the logarithm of the frequency

6.2. Block Diagram of Test Setup

                                                               Vert. reference
                                                                  plane
                                                                                                         EMI receiver




                                                   EUT




                            LISN                                             Reference ground plane




6.3. Test Results

PASS

Please refer to following pages for test plots;
.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 12 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


AC Conducted Emission of power adapter @ AC 120V/60Hz @ TX (worst case)

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report.


  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 13 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


7. RADIATED EMISSION MEASUREMENT

7.1. Standard Applicable
     According to FCC § 15.249: Emissions radiated outside of the specified frequency bands, except for
     harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general
     radiated emission limits in §15.209, whichever is the lesser attenuation.
     20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall
     within the restricted band specified on 15.205(a), then the 15.209(a) and 15.249 limit in the table
     below has to be followed.

           Fundamental                    Field Strength of fundamental                   Field Strength of harmonics
            Frequency                            (millivolts/meter)                            (microvolts/meter)
           902-928MHz                                    50                                           500
         2400-2483.5MHz                                  50                                           500
          5725-5875MHz                                   50                                           500
          24.0-24.25GHz                                 250                                          2500

               Frequencies                               Field Strength                         Measurement Distance
                   (MHz)                               (microvolts/meter)                             (meters)
               0.009~0.490                                2400/F(KHz)                                   300
               0.490~1.705                               24000/F(KHz)                                   30
                1.705~30.0                                     30                                       30
                  30~88                                       100                                        3
                  88~216                                      150                                        3
                 216~960                                      200                                        3
                Above 960                                     500                                        3


     According to RSS-210 B.10:
     The field strength of fundamental and harmonic emissions, measured at 3 m, shall not exceed 50
     mV/m and 0.5 mV/m respectively.
     The field strength limits shall be measured using an average detector, except for the fundamental
     emission in the frequency band 902-928 MHz, which is based on measurements using an
     International Special Committee on Radio Interference (CISPR) quasi-peak detector.
     Emissions radiated outside of the specified frequency bands, except for harmonic emissions, shall be
     attenuated by at least 50 dB below the level of the fundamental emissions or to the general field
     strength limits listed in RSS-Gen, whichever is less stringent.

7.2. Instruments Setting
     Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and
     receiver.

   Spectrum Parameter                                        Setting
   Attenuation                                               Auto
   Start Frequency                                           1000 MHz
   Stop Frequency                                            10th carrier harmonic
   RB / VB (Emission in restricted band)                     1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average
   RB / VB (Emission in non-restricted band)                 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 14 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


   Receiver Parameter                                           Setting
   Attenuation                                                  Auto
   Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
   Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
   Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

7.3. Test Procedure

     1) Sequence of testing 9 kHz to 30 MHz


     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
     --- If the EUT is a floor standing device, it is placed on the ground.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.

     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna height is 0.8 meter.
     --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
     emissions

     Final measurement:
     --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
     position (0° to 360°) and by rotating the elevation axes (0° to 360°).
     --- The final measurement will be done in the position (turntable and elevation) causing the highest
     emissions with QPK detector.
     --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin
     to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit
     will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 15 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA




     2) Sequence of testing 30 MHz to 1 GHz

     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
     plane.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.

     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna is polarized vertical and horizontal.
     --- The antenna height changes from 1 to 3 meter.
     --- At each turntable position, antenna polarization and height the analyzer sweeps three times in
     peak to find the maximum of all emissions.

     Final measurement:
     --- The final measurement will be performed with minimum the six highest peaks.
     --- According to the maximum antenna and turntable positions of premeasurement the software
     maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
     meter.
     --- The final measurement will be done with QP detector with an EMI receiver.
     --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
     turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
     graph of the premeasurement with marked maximum final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 16 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA




     3) Sequence of testing 1 GHz to 18 GHz

     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.

     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna is polarized vertical and horizontal.
     --- The antenna height scan range is 1 meter to 2.5 meter.
     --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find
     the maximum of all emissions.

     Final measurement:
     --- The final measurement will be performed with minimum the six highest peaks.
     --- According to the maximum antenna and turntable positions of premeasurement the software
     maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
     meter. This procedure is repeated for both antenna polarizations.
     --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
     causing the highest emissions with Peak and Average detector.
     --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position,
     antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with
     the graph of the premeasurement with marked maximum final measurements and the limit will be
     stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 17 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA




     4) Sequence of testing above 18 GHz

     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 1 meter.
     --- The EUT was set into operation.

     Premeasurement:
     --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

     Final measurement:
     --- The final measurement will be performed at the position and antenna orientation for all detected
     emissions that were found during the premeasurements with Peak and Average detector.
     --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and
     limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 18 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


7.4. Block Diagram of Test Setup




     Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
     dB/decade form 3m to 1m.
     Distance extrapolation factor = 20 log (specific distance [3m] / test distance [1.5m]) (dB);
     Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

7.5 EUT Operation during Test
     The EUT was programmed to be in continuously transmitting mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 19 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


7.6. Test Results of Radiated Emissions (9 KHz~30 MHz)

            Temperature                          23.6℃                     Humidity                         52.8%
            Test Engineer                     Diamond Lu                 Configurations                    915 MHz

               Freq.                    Level               Over Limit               Over Limit
                                                                                                               Remark
              (MHz)                    (dBuV)                 (dB)                    (dBuV)
                 -                        -                       -                        -                  See Note


Note:
The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value
has no need to be reported.
Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
Limit line = specific limits (dBuV) + distance extrapolation factor.

7.7. Test Results of Radiated Emissions (30 MHz – 1000 MHz)

            Temperature                        23.9℃                     Humidity                         54.2%
            Test Engineer                      Tom Liu

                                               Field Strength of Fundamental
        Frequency                              Measure Result        QP Limit                   Margin
                                 Pol.                                                                                Result
          (MHz)                                (QP, dBuV/m)         (dBuV/m)                   (dBuV/m)
           909                     H                91.28             94.00                      -2.72                PASS
           909                     V                89.11             94.00                      -4.89                PASS
           915                     H                91.40             94.00                      -2.60                PASS
           915                     V                92.26             94.00                      -2.74                PASS
           921                     H                91.44             94.00                      -2.56                PASS
           921                     V                91.33             94.00                      -2.67                PASS




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 20 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


Horizontal




Vertical




***Note:
1). Emission level (dBuV/m) = 20 log Emission level (uV/m).
2). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.
3). Measured with 910-930 MHz filter in order to avoid spectrum overload.

  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 21 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


7.8. Results for Radiated Emissions (1 – 10 GHz)

TX @ 909 MHz
            Reading         Ant.         Pre.         Cab.
 Freq.                                                            Measured         Limit        Margin
             Level          Fac.         Fac.         Loss                                                  Remark            Pol.
 MHz                                                               dBuV/m         dBuV/m         dB
             dBuV          dB/m           dB           dB
1818.00      53.11         33.06        35.04         2.14           53.27          74.00       -20.73       Peak         Horizontal
1818.00      34.13         33.06        35.04         2.14           34.29          54.00       -19.71      Average       Horizontal
1818.00      54.34         33.06        35.04         2.14           54.50          74.00       -19.50       Peak          Vertical
1818.00      36.30         33.06        35.04         2.14           36.46          54.00       -17.54      Average        Vertical
2727.00      53.99         33.11        35.09         2.72           54.73          74.00       -19.27       Peak         Horizontal
2727.00      35.69         33.11        35.09         2.72           36.43          54.00       -17.57      Average       Horizontal
2727.00      55.76         33.11        35.09         2.72           56.50          74.00       -17.50       Peak          Vertical
2727.00      36.62         33.11        35.09         2.72           37.36          54.00       -16.64      Average        Vertical
3636.00      52.92         33.03        35.07         3.12           54.00          74.00       -20.00       Peak         Horizontal
3636.00      35.26         33.03        35.07         3.12           36.34          54.00       -17.66      Average       Horizontal
3636.00      55.01         33.03        35.07         3.12           56.09          74.00       -17.91       Peak          Vertical
3636.00      37.88         33.03        35.07         3.12           38.96          54.00       -15.04      Average        Vertical
4545.00      52.18         33.26        35.14         3.98           54.28          74.00       -19.72       Peak         Horizontal
4545.00      35.99         33.26        35.14         3.98           38.09          54.00       -15.91      Average       Horizontal
4545.00      54.20         33.26        35.14         3.98           56.30          74.00       -17.70       Peak          Vertical
4545.00      37.13         33.26        35.14         3.98           39.23          54.00       -14.77      Average        Vertical

TX @ 915 MHz
            Reading         Ant.         Pre.         Cab.
 Freq.                                                            Measured         Limit        Margin
             Level          Fac.         Fac.         Loss                                                  Remark            Pol.
 MHz                                                               dBuV/m         dBuV/m         dB
             dBuV          dB/m           dB           dB
1830.00      53.78         33.06        35.04         2.14           53.94          74.00       -20.06       Peak         Horizontal
1830.00      34.20         33.06        35.04         2.14           34.36          54.00       -19.64      Average       Horizontal
1830.00      54.89         33.06        35.04         2.14           55.05          74.00       -18.95       Peak          Vertical
1830.00      37.70         33.06        35.04         2.14           37.86          54.00       -16.14      Average        Vertical
2745.00      53.05         33.11        35.09         2.72           53.79          74.00       -20.21       Peak         Horizontal
2745.00      34.93         33.11        35.09         2.72           35.67          54.00       -18.33      Average       Horizontal
2745.00      55.18         33.11        35.09         2.72           55.92          74.00       -18.08       Peak          Vertical
2745.00      37.96         33.11        35.09         2.72           38.70          54.00       -15.30      Average        Vertical
3660.00      53.13         33.03        35.07         3.12           54.21          74.00       -19.79       Peak         Horizontal
3660.00      35.50         33.03        35.07         3.12           36.58          54.00       -17.42      Average       Horizontal
3660.00      55.06         33.03        35.07         3.12           56.14          74.00       -17.86       Peak          Vertical
3660.00      36.36         33.03        35.07         3.12           37.44          54.00       -16.56      Average        Vertical
4575.00      53.87         33.26        35.14         3.98           55.97          74.00       -18.03       Peak         Horizontal
4575.00      34.97         33.26        35.14         3.98           37.07          54.00       -16.93      Average       Horizontal
4575.00      54.81         33.26        35.14         3.98           56.91          74.00       -17.09       Peak          Vertical
4575.00      37.73         33.26        35.14         3.98           39.83          54.00       -14.17      Average        Vertical




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 22 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


TX @ 921MHz
            Reading         Ant.         Pre.         Cab.
 Freq.                                                            Measured         Limit        Margin
             Level          Fac.         Fac.         Loss                                                  Remark            Pol.
 MHz                                                               dBuV/m         dBuV/m         dB
             dBuV          dB/m           dB           dB
1842.00      53.99         33.06        35.04         2.14           54.15          74.00       -19.85       Peak         Horizontal
1842.00      35.99         33.06        35.04         2.14           36.15          54.00       -17.85      Average       Horizontal
1842.00      55.94         33.06        35.04         2.14           56.10          74.00       -17.90       Peak          Vertical
1842.00      37.08         33.06        35.04         2.14           37.24          54.00       -16.76      Average        Vertical
2763.00      53.49         33.11        35.09         2.72           54.23          74.00       -19.77       Peak         Horizontal
2763.00      35.61         33.11        35.09         2.72           36.35          54.00       -17.65      Average       Horizontal
2763.00      54.33         33.11        35.09         2.72           55.07          74.00       -18.93       Peak          Vertical
2763.00      37.29         33.11        35.09         2.72           38.03          54.00       -15.97      Average        Vertical
3684.00      52.74         33.03        35.07         3.12           53.82          74.00       -20.18       Peak         Horizontal
3684.00      34.61         33.03        35.07         3.12           35.69          54.00       -18.31      Average       Horizontal
3684.00      54.03         33.03        35.07         3.12           55.11          74.00       -18.89       Peak          Vertical
3684.00      37.66         33.03        35.07         3.12           38.74          54.00       -15.26      Average        Vertical
4605.00      53.78         33.26        35.14         3.98           55.88          74.00       -18.12       Peak         Horizontal
4605.00      34.45         33.26        35.14         3.98           36.55          54.00       -17.45      Average       Horizontal
4605.00      55.69         33.26        35.14         3.98           57.79          74.00       -16.21       Peak          Vertical
4605.00      37.18         33.26        35.14         3.98           39.28          54.00       -14.72      Average        Vertical


Notes:
1). Measuring frequencies from 9 KHz - 10th harmonic (ex. 26GHz), No emission found between lowest
internal used/generated frequency to 30 MHz.
2). Radiated emissions measured in frequency range from 9 KHz - 10th harmonic (ex. 26GHz) were made
with an instrument using Peak detector mode.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 23 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


8. RESULTS FOR BAND EDGE TESTING

8.1. Standard Applicable

     According to FCC §15.249 (d): Emissions radiated outside of the specified frequency bands, except
     for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the
     general radiated emission limits in §15.209, whichever is the lesser attenuation.
     According to RSS-210 B.10 (b): Emissions radiated outside of the specified frequency bands, except
     for harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental
     emissions or to the general field strength limits listed in RSS-Gen, whichever is less stringent.

8.2. Test Setup Layout




8.3. Measuring Instruments and Setting

   Receiver Parameter                                           Setting
   Attenuation                                                  Auto
   Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
   Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
   Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 24 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


8.4. Test Procedures

     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
     plane.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.

     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna is polarized vertical and horizontal.
     --- The antenna height changes from 1 to 3 meter.
     --- At each turntable position, antenna polarization and height the analyzer sweeps three times in
     peak to find the maximum of all emissions.

     Final measurement:
     --- The final measurement will be performed with minimum the six highest peaks.
     --- According to the maximum antenna and turntable positions of premeasurement the software
     maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
     meter.
     --- The final measurement will be done with QP detector with an EMI receiver.
     --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
     turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
     graph of the premeasurement with marked maximum final measurements and the limit will be stored.

8.5. Measuring Instruments and Setting




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 25 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


Horizontal




Vertical




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 26 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


Horizontal




Vertical




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 27 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


9. 99% OCCUPIED BANDWIDTH AND 20 DB BANDWIDTH MEASUREMENT

9.1. Standard Applicable
     According to § 2.1049 and RSS-Gen section 6.7 “The occupied bandwidth or the “99% emission
     bandwidth” is defined as the frequency range between two points, one above and the other below the
     carrier frequency, within which 99% of the total transmitted power of the fundamental transmitted
     emission is contained. The occupied bandwidth shall be reported for all equipment in addition to the
     specified bandwidth required in the applicable RSSs.”
     In some cases, the “x dB bandwidth” is required, which is defined as the frequency range between
     two points, one at the lowest frequency below and one at the highest frequency above the carrier
     frequency, at which the maximum power level of the transmitted emission is attenuated x dB below
     the maximum in band power level of the modulated signal, where the two points are on the outskirts
     of the in-band emission.

9.2. Block Diagram of Test Setup




9.3. Test Procedure

     Use the following spectrum analyzer settings:
     Span = 500 KHz
     RBW = 3 KHz
     VBW = 10 KHz
     Sweep = auto
     Detector function = peak
     Trace = max hold
     The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
     marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function
     to measure 20 dB down one side of the emission. Reset the marker-delta function, and move the
     marker to the other side of the emission, until it is (as close as possible to) even with the reference
     marker level. The marker-delta reading at this point is the 20 dB bandwidth of the emission. If this
     value varies with different modes of operation (e.g., data rate, modulation format, etc.), repeat this test
     for each variation. The limit is specified in one of the subparagraphs of this Section. Submit this
     plot(s).

9.4. Test Results

                                Test Result of 99% and 20dB Bandwidth Measurement
           Test Frequency             20dB Bandwidth        99% Bandwidth             Limit
                (MHz)                       (MHz)               (MHz)                (MHz)
                 909                        189.00              190.41            Non-Specified
                 915                        156.30              196.87            Non-Specified
                 921                        120.50              158.21            Non-Specified


  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 28 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


Remark:
1. Test results including cable loss;
2. Please refer following test plots;

                                           20dB Bandwidth and 99% Bandwidth
                             ASK                                                                   ASK




                          909 MHz                                                               915 MHz




                          921 MHz




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 29 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA



10. LIST OF MEASURING EQUIPMENT
Item Equipment                      Manufacturer             Model No.               Serial No.           Last Cal.         Next Cal.
1     Power Meter                   R&S                      NRVS                    100444               2018-06-16        2019-06-15
2     Power Sensor                  R&S                      NRV-Z81                 100458               2018-06-16        2019-06-15
3     Power Sensor                  R&S                      NRV-Z32                 10057                2018-06-16        2019-06-15
      ESA-E SERIES
4                       Agilent                              E4407B                  MY41440754           2018-11-16        2019-11-15
      SPECTRUM ANALYZER
5     MXA Signal Analyzer           Agilent                  N9020A                  MY49100040           2018-06-16        2019-06-15
6     SPECTRUM ANALYZER R&S                                  FSP                     100503               2018-06-16        2019-06-15
      3m Semi Anechoic
7                                   SIDT FRANKONIA           SAC-3M                  03CH03-HY            2018-06-16        2019-06-15
      Chamber
8     Positioning Controller        MF                       MF-7082                 /                    2018-06-16        2019-06-15
9     EMI Test Software             AUDIX                    E3                      N/A                  N/A               N/A
10    EMI Test Receiver             R&S                      ESR 7                   101181               2018-06-16        2019-06-15
11    AMPLIFIER                     QuieTek                  QTK-A2525G              CHM10809065          2018-11-16        2019-11-15
12    Active Loop Antenna           SCHWARZBECK              FMZB 1519B              00005                2018-06-22        2019-06-21
13    By-log Antenna                SCHWARZBECK              VULB9163                9163-470             2018-05-02        2019-05-01
14    Horn Antenna                  SCHWARZBECK              BBHA 9120 D             9120D-1925           2018-07-02        2019-07-01
15    Broadband Horn Antenna SCHWARZBECK                     BBHA 9170               791                  2018-09-20        2019-09-19
16    Broadband Preamplifier        SCHWARZBECK              BBV 9719                9719-025             2018-09-20        2019-09-19
17    RF Cable-R03m                 Jye Bao                  RG142                   CB021                2018-06-16        2019-06-15
18    RF Cable-HIGH                 SUHNER                   SUCOFLEX 106            03CH03-HY            2018-06-16        2019-06-15
19    TEST RECEIVER                 R&S                      ESCI                    101142               2018-06-16        2019-06-15
20    RF Cable-CON                  UTIFLEX                  3102-26886-4            CB049                2018-06-16        2019-06-15
21    10dB Attenuator               SCHWARZBECK              MTS-IMP136              261115-001-0032 2018-06-16             2019-06-15
22    Artificial Mains              R&S                      ENV216                  101288               2018-06-16        2019-06-15
                                    JS Tonscend
23    RF Control Unit                                        JS0806-2                178060073            2018-10-27        2019-10-26
                                    Corporation
      JS1120-3 BT/WIFI Test         JS Tonscend
24                                                           JS1120-3                /                    N/A               N/A
      Software                      Corporation
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 30 of 31


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADXC18IR388            Report No.: LCS180525011AEA


11. TEST SETUP PHOTOGRAPHS OF THE EUT

     Please refer to separated files for Test Setup Photos of the EUT.


12. EXTERIOR PHOTOGRAPHS OF THE EUT

     Please refer to separated files for External Photos of the EUT.


13. INTERIOR PHOTOGRAPHS OF THE EUT

     Please refer to separated files for Internal Photos of the EUT.




                                ------------THE END OF REPORT----------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 31 of 31



Document Created: 2018-11-27 17:22:53
Document Modified: 2018-11-27 17:22:53

© 2024 FCC.report