RF Exposure

FCC ID: 2ADX6-7320

RF Exposure Info

Download: PDF
FCCID_2562419

                                                            FCC ID: 2ADX6-7320


                              MPE Calculation Method

E (V/m) = (30*P*G) 0.5/d
Power Density: Pd (W/m2) = E2/377
E = Electric Field (V/m)
P = Peak RF output Power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd = (30*P*G) / (377*d2)
From the peak EUT RF output power, the minimum mobile separation distance,
d=0.2m, as well
as the gain of the used antenna, the RF power density can be obtained.
Calculated Result and Limit(WORSE CASE IS AS BELOW)
  Antenna       Peak Output        Power Density         Limit of Power        Test
   Gain         Power (mW)         (S) (mW/cm2)            Density (S)        Result
 (Numeric)                                                 (mW/cm2)


    0dBi         0.06471              0.01287                  1             Compiles
               (18.11dBm)



Document Created: 2015-03-22 14:14:21
Document Modified: 2015-03-22 14:14:21