  1       Cover Page

                    RF Exposure Evaluation Report
  Application No.:                       SHEM1903011461CR
  FCC ID:                                2ADTD-K1T607TMFW
  Applicant:                             Hangzhou Hikvision Digital Technology Co., Ltd.
  Address of Applicant:                  No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
  Manufacturer:                          Hangzhou Hikvision Digital Technology Co., Ltd.
  Address of Manufacturer:               No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
  Factory:                               1. Hangzhou Hikvision Technology Co., Ltd.
                                         2. Hangzhou Hikvision Electronics Co., Ltd.
                                         3, Hangzhou Hikvision Digital Technology Co., Ltd.
  Address of Factory:                    1. No.700, Dongliu Road, Binjiang District, Hangzhou City, Zhejiang,
                                         310052, China
                                         2. No.299, Qiushi Road, Tonglu Economic Development Zone, Tonglu
                                         County, Hangzhou, Zhejiang, 310052, China.
                                         3, No. 555 Qianmo Road, Binjiang District, Hangzhou 310052, China
  Equipment Under Test (EUT):
  EUT Name:                 Face Recognition Terminal
  Model No.:                             DS-K1T607TMFW, DS-K1T607MFW
  Add Model No.:                         Refer to Page 2
  Standard(s) :                          FCC Rules 47 CFR §2.1091
                                         KDB447498 D01 General RF Exposure Guidance v06
  Date of Receipt:                       2019-03-12
  Date of Test:                          2019-03-15 to 2019-03-18
  Date of Issue:                         2019-04-18

  Test Result:                     Pass*
  * In the configuration tested, the EUT complied with the standards specified above.




               Parlam Zhan
            E&E Section Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by
SGS International Electrical Approvals in writing.


                 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                 Branch
                                                  Report No.: SHEM190301146103
                                                  Page:       2 of 8




Add Model No.:
DS-K1T607TMW,DS-K1T607TMF,DS-K1T607TM,DS-K1T607PMFW,DS-K1T607PMW,DS-
K1T607ATMFW,DS-K1T607ATMW,DS-K1T607ATMF,DS-K1T607ATM,DS-K1T607APMFW,DS-
K1T607APMW,DS-K1T607TMUHK,DS-K1T607TMCKV,DS-K1T607TMUVS,DS-K1T607TMKVO,DS-
K1T607TMHUN,DS-K1T607TMFUHK,DS-K1T607TMFCKV,DS-K1T607TMFUVS,DS-K1T607TMFKVO,DS-
K1T607TMFHUN,DS-K1T607MW,DS-K1T607MF,DS-K1T607M,DS-K1T607AMFW,DS-K1T607AMW,DS-
K1T607AMF,DS-K1T607AM,DS-K1T607MUHK,DS-K1T607MCKV,DS-K1T607MUVS,DS-K1T607MKVO,DS-
K1T607MHUN,DS-K1T607MFUHK,DS-K1T607MFCKV,DS-K1T607MFUVS,DS-K1T607MFKVO,DS-
K1T607MFHUN


               SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
               Branch
                                                         Report No.: SHEM190301146103
                                                         Page:       3 of 8




                                   Revision Record
  Version        Description                   Date                    Remark

      00           Original                 2019-04-18                     /




Authorized for issue
by:




                              Vincent Zhu /Project Engineer




                              Parlam Zhan /Reviewer


                                     SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                     Branch
                                                                                                            Report No.: SHEM190301146103
                                                                                                            Page:       4 of 8




2         Contents
                                                                                                                                                               Page
1     COVER PAGE................................................................................................................................................. 1
2     CONTENTS ..................................................................................................................................................... 4
3     GENERAL INFORMATION ......................................................................................................................... 5
    3.1    GENERAL DESCRIPTION OF E.U.T.................................................................................................................. 5
    3.2    TEST LOCATION ............................................................................................................................................. 6
    3.3    TEST FACILITY............................................................................................................................................... 6
4     TEST STANDARDS AND LIMITS .............................................................................................................. 7
    4.1    FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS: ................................................................................ 7
5     MEASUREMENT AND CALCULATION ................................................................................................... 7
    5.1    MAXIMUM TRANSMIT POWER ........................................................................................................................ 7
    5.2    MPE CALCULATION ...................................................................................................................................... 8


                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                      Branch
                                                        Report No.: SHEM190301146103
                                                        Page:       5 of 8




3    General Information

3.1 General Description of E.U.T.
     Power supply:         DC 12V by AC Adapter
     Test voltage:         AC 120V 60Hz




2.4GWiFi:
    Antenna Gain           3.05 dBi
    Antenna Type           PCB Antenna
    Channel Spacing        5MHz
    Modulation Type        802.11b: DSSS (CCK, DQPSK, DBPSK)
                           802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK)
     Number of Channels    802.11b/g/n(HT20):11
                           802.11n(HT40):7
     Operation Frequency   802.11b/g/n(HT20): 2412MHz to 2462MHz
                           802.11n(HT40): 2422MHz to 2452MHz

13.56MHz:
     Antenna Type          Loop Antenna
     Modulation Type       ASK
     Number of Channels    1
     Operation Frequency   13.56MHz


                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                      Branch
                                                                     Report No.: SHEM190301146103
                                                                     Page:       6 of 8




3.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch
    588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China.
    Tel: +86 21 6191 5666
    Fax: +86 21 6191 5678

3.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
     • CNAS (No. CNAS L0599)
    CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC
    17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
    (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for
    the competence in the field of testing.
     • NVLAP (Certificate No. 201034-0)
    SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National Voluntary
    Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0.
     • FCC –Designation Number: CN5033
    SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an accredited
    testing laboratory.
    Designation Number: CN5033. Test Firm Registration Number: 479755.
     • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    IC Registration No.: 8617A-1. CAB identifier: CN0020.
     • VCCI (Member No.: 3061)
    The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
    (Shanghai) Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control
    Measures with Registration No.: R-13868, C-14336, T-12221, G-10830 respectively.


                         SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                         Branch
                                                                   Report No.: SHEM190301146103
                                                                   Page:       7 of 8



4     Test Standards and Limits

4.1 FCC Radiofrequency radiation exposure limits:
 According to§1.1310, the limit for general population/uncontrolled exposures

            Frequency             Power density(mW/cm2)      Averaging time(minutes)

     1.34 MHz -30 MHz                    *180/f2                       30
     30 MHz -300 MHz                       0.2                         30
      300MHz~1.5GHz                      f/1500                        30

      1.5GHz~100GHz                        1.0                         30

 Note: f = frequency in MHz * = Plane-wave equivalent power density
 For 13.56MHz band, the limit of worse case is 0.98mW/cm2
 For 2.4GHz band, the limit is 1.0 mW/cm2

5     Measurement and Calculation

5.1 Maximum transmit power
 The Power Data is based on the RF Test Report SHEM190301146101& SHEM190301146102
2.4GWiFi:
    2Test          Test                  Level       Power        Power
                                Ant
    Mode          Channel                            [dBm]        [mW]
                                        [dBm]
     11B           2412         Ant1    16.13        16.13         41.02
     11B           2437         Ant1    16.72        16.72         46.99
     11B           2462         Ant1    16.92        16.92         49.20
     11G           2412         Ant1    14.87        14.87         30.69
     11G           2437         Ant1    15.54        15.54         35.81
     11G           2462         Ant1    15.72        15.72         37.33
 11N20SISO         2412         Ant1    14.33        14.33         27.10
 11N20SISO         2437         Ant1    14.98        14.98         31.48
 11N20SISO         2462         Ant1    15.18        15.18         32.96
 11N40SISO         2422         Ant1    12.95        12.95         19.72
 11N40SISO         2437         Ant1    13.34        13.34         21.58
 11N40SISO         2452         Ant1    13.51        13.51         22.44

13.56MHz:
 Frequency                                                      Output Power           Output Power
                        Model            Level (dBuV/m)
   (MHz)                                                           (dBm)                  (mW)
                 DS-K1T607TMFW               57.98                 -37.32                0.00019
    13.56
                  DS-K1T607MFW               61.25                 -34.05                0.00039


                           SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                           Branch
                                                                    Report No.: SHEM190301146103
                                                                    Page:       8 of 8




5.2 MPE Calculation
For FCC:
                                PG
 According to the formula S=           , we can calculate S which is MPE.
                               4R 2π
 Note:
 1) P (Watts)
 2) G (Antenna gain in numeric)
 3) R = distance to the center of radiation of antenna (in meter) = 20cm
 4) MPE limit = 1mW/cm²
 The max conducted output power is s 49.2 mW .
 The best case gain of the antenna is3.05 dBi. 3.05dB logarithmic terms convert to numeri
                                                                                       c
 result is nearly 2.02 .
              PG
 So, S=                  = 0.02 mW/cm2 <1mW/cm²
            4R   2
                     π

 For 13.56MHz: The Max E.I.R.P is 0.00039 mW.
       PG
 S=           =0.00039/(4*400*3.14)=7.76*10-8mW/cm2
      4R 2π
 13.56MHz and WiFi modules can simultaneous transmitting, so the maximum rate of MPE is
 (0.02/1)+( 7.76*10-8/0.98)=0.02<=1.0. according to the KDB447498 section 7.2 determine the device is