12150954-E2V4 FCC Report Part18

FCC ID: 2ADNG-NF230

Test Report

Download: PDF
FCCID_3808027

     CERTIFICATION TEST REPORT
               Report Number. : 12150954-E2V4
      Applicant :    ENERGOUS CORPORATION
                     3590 NORTH FIRST STREET
                     SAN JOSE, CA 95134 U.S.A.

         Model :     NF-230

         FCC ID :    2ADNG-NF230

EUT Description :    WIRELESS CHARGER

Test Standard(s) :   FCC 47 CFR PART 18 SUBPART C




                            Date Of Issue:
                            March 30, 2018

                            Prepared by:
                      UL Verification Services Inc.
                         47173 Benicia Street
                      Fremont, CA 94538, U.S.A.
                         TEL: (510) 771-1000
                         FAX: (510) 661-0888




                     NVLAP LAB CODE 200065-0


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

                                                 Revision History
            Issue
Rev.        Date              Revisions                                                       Revised By
  V1         3/6/2018         Initial Issue                                                   --
                              Updated Section 5.2 & 5.4 to address TCB’s
  V2        3/13/2018                                                                         Tina Chu
                              question
  V3        3/14/2018         Updated Page 8, Section 5.2 statement                           Sol Kuwatani
  V4        3/30/2018         Added statement on Section 7.1.2                                Tina Chu




                                                    Page 2 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                              DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

                                             TABLE OF CONTENTS


1.     ATTESTATION OF TEST RESULTS ................................................................................. 4

2.     TEST METHODOLOGY ..................................................................................................... 6

3.     FACILITIES AND ACCREDITATION ................................................................................. 6

4.     CALIBRATION AND UNCERTAINTY ................................................................................ 7
     4.1.    MEASURING INSTRUMENT CALIBRATION .............................................................. 7
     4.2.    SAMPLE CALCULATION ............................................................................................ 7
     4.3.    MEASUREMENT UNCERTAINTY ............................................................................... 7

5.     EQUIPMENT UNDER TEST ............................................................................................... 8
     5.1.    DESCRIPTION OF EUT .............................................................................................. 8
     5.2.    OPERATING FREQUENCY AND POWER .................................................................. 8
     5.3.    SOFTWARE AND FIRMWARE .................................................................................... 8
     5.4.    CONFIGURATION AND INVESTIGATED ................................................................... 8
     5.5.    MODIFICATIONS ........................................................................................................ 8
     5.6.    DESCRIPTION OF TEST SETUP ................................................................................ 9

6.     TEST AND MEASUREMENT EQUIPMENT ......................................................................10

7.     APPLICABLE LIMITS AND TEST RESULTS ...................................................................11
     7.1. RADIATED EMISSIONS .............................................................................................11
       7.1.1. SPURIOUS EMISSIONS 9 kHz TO 30 MHz ........................................................12
       7.1.2. SPURIOUS EMISSIONS 30 MHz TO 1000 MHz .................................................13
       7.1.3. SPURIOUS EMISSIONS 1 GHz TO 10 GHz........................................................18
     7.2.    AC POWER LINE CONDUCTED EMISSIONS ...........................................................20

8.     SETUP PHOTOS ...............................................................................................................23




                                                          Page 3 of 24
UL VERIFICATION SERVICES INC.                                                                        FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                              TEL: (510) 771-1000           FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                       ENERGOUS CORPORATION
                                    3590 NORTH FIRST STREET
                                    SAN JOSE, CA 95134 U.S.A.

EUT DESCRIPTION:                    WIRELESS CHARGER

MODEL NUMBER:                       NF-230

SERIAL NUMBER:                      DD0172114010

DATE TESTED:                        FEBRUARY 22, 2018 – MARCH 05, 2018

                                         APPLICABLE STANDARDS
                              STANDARD                                                  TEST RESULTS
                      FCC PART 18 SUBPART C                                                 Complies


UL Verification Services Inc. tested the above equipment in accordance with the requirements
set forth in the above standards. All indications of Pass/Fail in this report are opinions
expressed by UL Verification Services Inc. based on interpretations and/or observations of test
results. Measurement Uncertainties were not taken into account and are published for
informational purposes only. The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.

Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein. This document may not be altered or
revised in any way unless done so by UL Verification Services Inc. and all revisions are duly
noted in the revisions section. Any alteration of this document not carried out by UL Verification
Services Inc. will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of U.S. government.




                                                    Page 4 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230


Approved & Released For
UL Verification Services Inc. By:                                Reviewed By:




FRANK IBRAHIM                                                   TINA CHU
OPERATIONS LEAD                                                 SENIOR PROJECT ENGINEER
UL Verification Services Inc.                                   UL Verification Services Inc.



Prepared By:
UL Verification Services Inc. By:




ERIC YU
TEST ENGINEER
UL Verification Services Inc.




                                                    Page 5 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with FCC / OST MP-5, “FCC
Methods of Measurements of Radio Noise Emissions from Industrial, Scientific, and Medical
Equipment.”


3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 and 47266
Benicia Street, Fremont, California, USA. Line conducted emissions are measured only at the
47173 address. The following table identifies which facilities were utilized for radiated emission
measurements documented in this report. Specific facilities are also identified in the test results
sections.

                 47173 Benicia Street                                  47266 Benicia Street
               ☒ Chamber A (IC:2324B-1)                           ☐    Chamber D (IC:22541-1)
               ☒ Chamber B (IC:2324B-2)                           ☐    Chamber E (IC:22541-2)
               ☐ Chamber C (IC:2324B-3)                           ☐    Chamber F (IC:22541-3)
                                                                  ☐    Chamber G (IC:22541-4)
                                                                  ☐    Chamber H (IC:22541-5)

The above test sites and facilities are covered under FCC Test Firm Registration # 208313.

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full
scope of accreditation can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm.




                                                    Page 6 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

4. CALIBRATION AND UNCERTAINTY

   4.1.          MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.

   4.2.          SAMPLE CALCULATION
Where relevant, the following sample calculation is provided:
      Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) +
      Cable Loss (dB) – Preamp Gain (dB)
      36.5 dBuV + 18.7 dB/m + 0.6 dB – 26.9 dB = 28.9 dBuV/m

   4.3.          MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

                      Parameter                              Uncertainty

      Conducted Disturbance, 9KHz to 0.15 MHz                3.84 dB

      Conducted Disturbance, 0.15 to 30 MHz                  3.65 dB

      Radiated Disturbance, 9KHz to 30 MHz                   3.15 dB

      Radiated Disturbance, 30 to 1000 MHz                   5.36 dB

      Radiated Disturbance,1000 to 18000 MHz                 4.32 dB

      Radiated Disturbance,18000 to 26000 MHz                4.45 dB

      Radiated Disturbance,26000 to 40000 MHz                5.24 dB

      Occupied Channel Bandwidth                             ±0.39 %


Uncertainty figures are valid to a confidence level of 95%.




                                                    Page 7 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

5. EQUIPMENT UNDER TEST

   5.1.          DESCRIPTION OF EUT
The EUT is a single client RF near-field, contact charger that operates when a receiving device
is placed on the charger pad’s surface. The charger pad uses BLE to pair with the receiving
device, and transmits a continuous carrier wave signal at 918 MHz frequency.

   5.2.          OPERATING FREQUENCY AND POWER
The EUT operates at 918 MHz.

The highest maximum measured conducted power is 28.8dBm for Antenna 1.
                                                           Max. Meas.
   Band                         Freq.                       Avg Pwr
                 Mode                        Antenna
   (MHz)                        (MHz)                        (dBm)
                                                            918 MHz
                                                 1            28.8
    918           CW             918
                                                 2            28.7



   5.3.          SOFTWARE AND FIRMWARE
The firmware installed in the EUT during testing was 3.0.1.64.
The software installed in the EUT during testing was WattUp app Version 3.1.13.

   5.4.          CONFIGURATION AND INVESTIGATED
The EUT supports two WPT antennas. The antennas are identical but placed at right angles to
each other. Only one of the antennas is active at a time depending upon the position of the
client device on the DUT. Investigation was performed on both antennas, it was determined that
antenna 1 was worst-case; thus, fall final testing was performed on antenna 1.

      Configuration                                         Description
                                   EUT is powered by AC/DC adapter via USB cable
                                   and a receiving device is placed on the surface of
 Charging mode
                                   the EUT and receives 918 MHz RF energy from
                                   EUT


   5.5.          MODIFICATIONS
No modifications were made during testing.




                                                     Page 8 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

   5.6.          DESCRIPTION OF TEST SETUP

SUPPORT EQUIPMENT

                                              Support Equipment List
           Description             Manufacturer          Model                          Serial Number                   FCC ID
            Receiver                Energous              N/A                               Key71                        N/A
         AC/DC Adapter               CUI INC            SMI10-S                            3517HB                        N/A



CABLES

                                                 I/O Cable List
 Cable                # of identical    Connector                         Cable
  No         Port         ports           Type      Cable Type          Length (m)                Remarks

   1         USB             1          micro USB      Unshielded            1         EUT to AC/DC adapter


TEST SETUP-CONDUCTED TEST AND RADIATED TEST

The EUT is powered by AC/DC adapter via USB cable, a receiving device is placed on the EUT
surface for wireless charging purpose.

SETUP DIAGRAM




                                                    Page 9 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


  REPORT NO: 12150954-E2V4                                                                     DATE: MARCH 30, 2018
  FCC ID: 2ADNG-NF230

  6. TEST AND MEASUREMENT EQUIPMENT
  The following test and measurement equipment was utilized for the tests documented in this
  report:

                                                TEST EQUIPMENT LIST
            Description                         Manufacturer        Model                          Asset           Cal Due
Antenna, Active Loop 9KHz to 30MHz                ETS-Lindgren                  6502                T757          09/14/2018
                                                   SONOMA
   Amplifier, 10KHz to 1GHz, 32dB                                               310N                T300          12/11/2018
                                                 INSTRUMENT
Spectrum Analyzer, PXA 3Hz to 44GHz                 Keysight                 N9030A                T1466          04/11/2018
       Antenna, Horn 1-18GHz                      ETS Lindgren                3117                 T863           06/09/2018
                                                                         AFS42-00101800-
        Amplifier, 1 to 18GHz                         Miteq                                         T493          12/16/2018
                                                                             25-S-42
                                                   SONOMA
   Amplifier, 10KHz to 1GHz, 32dB                                              8447D                 T10          02/14/2019
                                                 INSTRUMENT
Antenna, Broadband Hybrid, 30MHz to
                                                Sunol Sciences                   JB3                T899          06/15/2018
               2000MHz
Spectrum Analyzer, PXA 3Hz to 44GHz               Keysight                    N9030A               T1454          01/08/2019
      Filter, BRF 902 to 928MHz                MICRO-TRONICS                 BRC50722              T1847          07/15/2018
                                                   AC Line Conducted
  EMI Test Receiver 10Hz-26.5GHz              Rohde & Schwarz                  ESCI7            PRE0176493        02/21/2019
LISN for Conducted Emissions CISPR-
                                                    Fischer               50/250-25-2-01           T1310          06/15/2018
                 16
    Power Cable, Line Conducted
                                                      UL                        PG1                 T861          08/31/2018
             Emissions
                                             UL AUTOMATION SOFTWARE
        Radiated Software                             UL                      UL EMC                Ver 9.5, Dec 01, 2016
    AC Line Conducted Software                        UL                      UL EMC                Ver 9.5, May 26, 2015



  NOTES:

      1. Equipment listed above that calibrated during the testing period was set for test after the
         calibration.
      2. Equipment listed above that has a calibration due date during the testing period, the testing is
         completed before equipment expiration date.




                                                      Page 10 of 24
  UL VERIFICATION SERVICES INC.                                                                FORM NO: CCSUP4701I
  47173 BENICIA STREET, FREMONT, CA 94538, USA                        TEL: (510) 771-1000         FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                     DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

7. APPLICABLE LIMITS AND TEST RESULTS

    7.1.          RADIATED EMISSIONS

LIMIT

§18.301 Operating frequencies

The EUT operates at 918 MHz, within the tolerance of the ISM Frequency of 915 +/- 13MHz.

§18.305 Field Strength Limits
(b) The field strength levels of emissions which lie outside the bands specified in §18.301,
unless otherwise indicated, shall not exceed the following:

                                                       RF Power
                                   Operating                                    Field strength limit          Distance
        Equipment                                    generated by
                                   frequency                                           (μV/m)                 (meters)
                                                   equipment (watts)
Any type unless otherwise        Any ISM           Below 500                 25                             300
                                                                                                            1
specified (miscellaneous)        frequency         500 or more               25 × SQRT(power/500)            300

1
 Field strength may not exceed 10μV/m at 1600 meters. Consumer equipment operating below
1000 MHz is not permitted the increase in field strength otherwise permitted here for power over
500 watts.

The RF Power generated by the equipment is below 500 W therefore the field strength limit is
25uV/m at 300 m.

TEST PROCEDURE

FCC / OST MP-5

The frequency range was investigated from 9 kHz to 10 GHz.

For pre-scans above 1 GHz the resolution bandwidth is set to 1 MHz; the video bandwidth is set
to 30 KHz for peak measurements.

For final measurements above 1 GHz the resolution bandwidth is set to 1 MHz; the video
bandwidth is set to 3 MHz for peak measurements and as applicable for average
measurements.

KDB 414788 OATS and Chamber Correlation Justification

Base on FCC 15.31 (f) (2): measurements may be performed at a distance closer than that
specified in the regulations; however, an attempt should be made to avoid making
measurements in the near field.

OATs and chamber correlation testing had been performed and chamber measured test result
is the worst case test result.



                                                    Page 11 of 24
UL VERIFICATION SERVICES INC.                                                                FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                        TEL: (510) 771-1000         FAX: (510) 661-0888
    This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                          DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

RESULTS

          7.1.1. SPURIOUS EMISSIONS 9 kHz TO 30 MHz

ANTENNA LOOP FACE ON AND FACE OFF




DATA


Marker    Frequency     Meter    Det   Loop Antenna    Cbl (dB)   Dist Corr (dB)   Corrected     Part 18 Limit   Margin   Azimuth
            (MHz)      Reading            (dB/m)                                    Reading     300m (dBuV/m)     (dB)     (Degs)
                       (dBuV)                                                      (dBuVolts)
  1         .02715      43.16    Pk        13.2           .1           -40           16.46           28          -11.54   0-360
  3         .06116      39.63    Pk        11.1           .1           -40           10.83           28          -17.17   0-360
  2         .07823      34.98    Pk        10.9           .1           -40           5.98            28          -22.02   0-360
  4         .22961      43.24    Pk        10.8           .1           -40           14.14           28          -13.86   0-360
  6         .41536      40.48    Pk        10.7           .1           -40           11.28           28          -16.72   0-360
  5         .41536      41.6     Pk        10.7           .1           -40           12.4            28           -15.6   0-360
  7         .82999      33.6     Pk        10.6           .1           -40            4.3            28           -23.7   0-360
  8         .82999      34.84    Pk        10.6           .1           -40           5.54            28          -22.46   0-360

Pk - Peak detector

Note: Distance factor from 3m to 300m = 20log (3/300) = -40dB




                                                      Page 12 of 24
UL VERIFICATION SERVICES INC.                                                                     FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                           TEL: (510) 771-1000           FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

       7.1.2. SPURIOUS EMISSIONS 30 MHz TO 1000 MHz

Spurious Emissions 30 – 1000 MHz with a Notch Filter



30MHz – 902MHz HORIZONTAL & VERTICAL




                                                   Page 13 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230



928MHz – 1000MHz HORIZONTAL & VERTICAL




                                                   Page 14 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                                                  DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

DATA


Marker       Frequency    Meter    Det   AF T899   Amp/Cbl (dB)   Dist Corr (dB)   T1847 BRF   Corrected     Part 18    Margin   Azimuth   Height   Polarity
               (MHz)     Reading         (dB/m)                                       (dB)      Reading    Limit 300m    (dB)     (Degs)    (cm)
                         (dBuV)                                                                (dBuV/m)     (dBuV/m)
  1          72.7388     49.83     Pk     11.9        -28.3            -40            .5        -6.07         28        -34.07   0-360      100       V
  4          79.7165     47.26     Pk     11.2        -28.2            -40            .5        -9.24         28        -37.24   0-360      200       H
  5          154.2914    41.24     Pk     16.2        -27.3            -40            .5        -9.36         28        -37.36   0-360      200       H
  2          154.7275    41.37     Pk     16.1        -27.3            -40            .5        -9.33         28        -37.33   0-360      200       V
  6          889.7909    41.35     Pk     25.9        -23.5            -40            .5        4.25          28        -23.75   0-360      200       H
  3          889.7909    40.23     Pk     25.9        -23.5            -40            .5        3.13          28        -24.87   0-360      100       V



Marker       Frequency    Meter    Det   AF T899   Amp/Cbl (dB)   Dist Corr (dB)   T1847 BRF   Corrected     Part 18    Margin   Azimuth   Height   Polarity
               (MHz)     Reading         (dB/m)                                       (dB)      Reading    Limit 300m    (dB)     (Degs)    (cm)
                         (dBuV)                                                                (dBuV/m)     (dBuV/m)
  1          955.5116    41.34     Pk     26.8        -23.1            -40            .5        5.54          28        -22.46   0-360      200       H
  2          955.5296    34.35     Pk     26.8        -23.1            -40            .5        -1.45         28        -29.45   0-360      200       V


Pk - Peak detector

Note:

               Distance factor from 3m to 300m = 20log (3/300) = -40dB
               Notch filter was used to prevent system overloading.




                                                                     Page 15 of 24
UL VERIFICATION SERVICES INC.                                                                                            FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                                               TEL: (510) 771-1000              FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                                              DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

Spurious Emissions 800 – 1000 MHz without a Notch Filter


                        Horizontal




DATA
Marker      Frequency      Meter    Det   AF T899 (dB/m)   Dist Corr     Corrected   FCC PART18    Margin   Azimuth   Height   Polarity
              (MHz)       Reading                            (dB)         Reading     300m LIMIT    (dB)     (Degs)    (cm)
                          (dBuV)                                         (dBuV/m)      (dBuV/m)
  4          891.6        35.103    Pk        27.17          -40          22.27          28        -5.73     200       128        H
  5           958         34.479    Pk        27.77          -40          22.25          28        -5.75     189       157        H
Pk - Peak detector

Note: Distance factor from 3m to 300m = 20log (3/300) = -40dB




                                                                       Page 16 of 24
UL VERIFICATION SERVICES INC.                                                                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                                            TEL: (510) 771-1000              FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                                              DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230




                        Vertical




DATA
Marker      Frequency      Meter    Det   AF T899 (dB/m)   Dist Corr     Corrected   FCC PART18    Margin   Azimuth   Height   Polarity
              (MHz)       Reading                            (dB)         Reading     300m LIMIT    (dB)     (Degs)    (cm)
                          (dBuV)                                         (dBuV/m)      (dBuV/m)
  4          877.6         35.730   Pk        26.97          -40          22.70          28        -5.30     202       118        V
  5           977          35.235   Pk        27.88          -40          23.12          28        -4.88     157       129        V
Pk - Peak detector

Note: Distance factor from 3m to 300m = 20log (3/300) = -40dB




                                                                       Page 17 of 24
UL VERIFICATION SERVICES INC.                                                                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                                            TEL: (510) 771-1000              FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

       7.1.3. SPURIOUS EMISSIONS 1 GHz TO 10 GHz

HORIZONTAL & VERTICAL




                                                   Page 18 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                                     DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

DATA
 Marker    Frequency    Meter    Det   AF T863   Amp/Cbl (dB)    Fltr (dB)   Dist Corr (dB)   Corrected    Part 18 Limit   Margin   Azimuth   Height   Polarity
             (GHz)     Reading          (dB/m)                                                 Reading    300m (dBuV/m)     (dB)     (Degs)    (cm)
                       (dBuV)                                                                 (dBuV/m)
   2        * 2.754    53.17     ADR    32.3        -32.7           .5            -40          13.27           28          -14.73    168       240        H
   3        * 3.672    44.73     ADR    33.2        -31.7           .5            -40           6.73           28          -21.27    254       106        H
   4         * 4.59    57.83     ADR    34.3        -30.9           .5            -40          21.73           28           -6.27     91       108        H
  7         * 7.344    46.02     ADR    35.9        -29.1           .5            -40          13.32           28          -14.68    166       226        H
  8         * 8.262     40.6     ADR    36.1        -27.9           .5            -40           9.3            28           -18.7     41       107        H
  11         * 4.59    58.23     ADR    34.3        -30.9           .5            -40          22.13           28           -5.87    295       108        V
  14        * 7.344    54.08     ADR    35.9        -29.1           .5            -40          21.38           28           -6.62    167       115        V
  15        * 8.262     49.5     ADR    36.1        -27.9           .5            -40           18.2           28            -9.8      3       105        V
  10        * 2.754    49.95     ADR    32.3        -32.7           .5            -40          10.05           28          -17.95    194       107        V
  1          1.836     64.88     ADR    30.6        -33.6           .5            -40          22.38           28           -5.62    175       230        H
  9          1.836      61.4     ADR    30.6        -33.6           .5            -40           18.9           28            -9.1    104       307        V
  5          5.508     57.72     ADR    35.4         -31            .5            -40          22.62           28           -5.38    301       106        H
  12         5.508     60.64     ADR    35.4         -31            .5            -40          25.54           28           -2.46      5       204        V
  6          6.426     51.01     ADR    35.7        -30.1           .5            -40          17.11           28          -10.89    291       210        H
  13         6.426      55.2     ADR    35.7        -30.1           .5            -40           21.3           28            -6.7    145       102        V

* - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
ADR - AD primary method, RMS average

Distance factor from 3m to 300m = 20log (3/300) = -40dB




                                                            Page 19 of 24
UL VERIFICATION SERVICES INC.                                                                                FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                                 TEL: (510) 771-1000                FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

   7.2.          AC POWER LINE CONDUCTED EMISSIONS

LIMITS

§ 18.307 For the following equipment, when designed to be connected to the public utility (AC)
power line the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies shall not exceed the limits in the following table. Compliance with the
provisions of this paragraph shall be based on the measurements of the radio frequency voltage
between each power line and ground at the power terminal using a 50 μH/50 ohms line impedance
stabilization network (LISN).

§ 18.307 (b) All other Part 18 consumer devices:

                                                                      Conducted Limit (dBμV)
    Frequency of Emission (MHz)
                                                              Quasi-peak                 Average
               0.15-0.5                                        66 to 56 *               56 to 46 *
                 0.5-5                                             56                       46
                  5-30                                             60                       50
*Decreases with the logarithm of the frequency.

TEST PROCEDURE

FCC / OST MP-5

RESULTS




                                                   Page 20 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

LINE 1 RESULTS




WORST EMISSIONS

 Range 1: Line-L1 .15 - 30MHz
Marker   Frequency     Meter      Det     LISN       LC        Corrected    CFR 47     Margin     CFR 47      Margin
           (MHz)      Reading              L1       Cables     Reading      Part 15     (dB)      Part 15      (dB)
                      (dBuV)                        C1&C3       dBuV        Class B               Class B
                                                                              QP                    Avg
  1       .27825       38.72      Qp       0           0        38.72        60.87      -22.15       -           -
  2       .27825       23.3       Ca       0           0         23.3          -           -       50.87      -27.57
  3         .582       32.65      Qp       0           0        32.65         56        -23.35       -           -
  4        .5955       24.6       Ca       0           0         24.6          -           -        46         -21.4
  5       1.6395       21.1       Qp       0          .1         21.2         56         -34.8       -           -
  6       1.6395       10.53      Ca       0          .1        10.63          -           -        46        -35.37
  7      7.31175       39.82      Qp       0          .2        40.02         60        -19.98       -           -
  8      7.32975       24.48      Ca       0          .2        24.68          -           -        50        -25.32
  9      15.80325      27.75      Qp       0          .3        28.05         60        -31.95       -           -
 10      15.80213      16.5       Ca       0          .3         16.8          -           -        50         -33.2
 11      18.14775      26.94      Qp       0          .3        27.24         60        -32.76       -           -
 12      18.15225      21.11      Ca       0          .3        21.41          -           -        50        -28.59

Qp - Quasi-Peak detector
Ca - CISPR average detection




                                                   Page 21 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .


REPORT NO: 12150954-E2V4                                                                    DATE: MARCH 30, 2018
FCC ID: 2ADNG-NF230

LINE 2 RESULTS




WORST EMISSIONS

 Range 2: Line-L2 .15 - 30MHz
Marker   Frequency     Meter      Det     LISN       LC        Corrected    CFR 47     Margin     CFR 47      Margin
           (MHz)      Reading              L2       Cables     Reading      Part 15     (dB)      Part 15      (dB)
                      (dBuV)                        C2&C3       dBuV        Class B               Class B
                                                                              QP                    Avg
 13       .27938       37.83      Qp       0           0        37.83        60.83        -23        -           -
 14       .27825       24.83      Ca       0           0        24.83          -           -       50.87      -26.04
 15       .58425       36.05      Qp       0           0        36.05         56        -19.95       -           -
 16        .5865       29.69      Ca       0           0        29.69          -           -        46        -16.31
 17       1.6485       25.61      Qp       0          .1        25.71         56        -30.29       -           -
 18      1.64963       19.55      Ca       0          .1        19.65          -           -        46        -26.35
 19       7.3365       40.9       Qp       0          .2         41.1         60         -18.9       -           -
 20       7.3455       27.84      Ca       0          .2        28.04          -           -        50        -21.96
 21      16.00125      24.33      Qp       0          .3        24.63         60        -35.37       -           -
 22      16.00575      17.71      Ca       0          .3        18.01          -           -        50        -31.99
 23      17.7585       24.73      Qp       0          .3        25.03         60        -34.97       -           -
 24      17.75063      19.92      Ca       0          .3        20.22          -           -        50        -29.78

Qp - Quasi-Peak detector
Ca - CISPR average detection




                                                   Page 22 of 24
UL VERIFICATION SERVICES INC.                                                               FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA                       TEL: (510) 771-1000         FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc .



Document Created: 2019-09-21 08:37:41
Document Modified: 2019-09-21 08:37:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC