Test Report

FCC ID: 2ADM5-ET-0096

Test Report

Download: PDF
FCCID_4137026

                                             FCC PART 15.227
                   MEASUREMENT AND TEST REPORT
                                                                 For

                                Zeeva International Limited
    Suite 1007B,10th Floor, Exchange Tower, 33 Wang Chiu Road, Kowloon Bay, Hong Kong



                                         FCC ID: 2ADM5-ET-0096


              Report Type:                                        Product Type:
              Original Report                                     RC SPEEDBOAT REMOTE
                                                                  (27 mhz)


                   Report Number:            RSZ181220832-00


                        Report Date:         2019-01-02

                                             Rocky Kang

                       Reviewed By:          RF Engineer

                  Test Laboratory:           Bay Area Compliance Laboratories Corp. (Shenzhen)
                                             6/F., West Wing, Third Phase of Wanli Industrial
                                             Building, Shihua Road, Futian Free Trade Zone,
                                             Shenzhen, Guangdong, China
                                             Tel: +86-755-33320018
                                             Fax: +86-755-33320008
                                             www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of
the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk
“*”.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ181220832-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION ..........................................................................................................................4
  JUSTIFICATION .............................................................................................................................................................4
  EUT EXERCISE SOFTWARE ..........................................................................................................................................4
  EQUIPMENT MODIFICATIONS .......................................................................................................................................4
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................4
SUMMARY OF TEST RESULTS ...............................................................................................................................5
TEST EQUIPMENT LIST ...........................................................................................................................................6

FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
  ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................7
FCC§15.205, §15.209, §15.227(A), §15.227 (B) – FIELD STRENGTH AND RESTRICTED BAND
EMISSIONS ...................................................................................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC§15.215(C) - 20DB EMISSION BANDWIDTH ................................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  TEST DATA ................................................................................................................................................................12




FCC Part 15.227                                                                                                                                         Page 2 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181220832-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Zeeva International Limited’s product, model number: FB36031 (FCC ID: 2ADM5-ET-0096, UPC
Number: 192234018804, SKU Number: 3104882) in this report is a RC SPEEDBOAT REMOTE (27mhz),
which was measured approximately: 24.5 cm (L) *9.5 cm (W) * 2.3 cm (H), rated with input voltage: DC
1.5V*3 from battery.

* All measurement and test data in this report was gathered from production sample serial number: 20181220.
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-12-20.


Objective
This report is prepared on behalf of Zeeva International Limited in accordance with Part 2-Subpart J, and
Part 15-Subparts A and C of the Federal Communication Commission’s rules.

The objective is to determine the compliance of EUT with FCC rules, section 15.203, 15.205, 15.209,
15.215 and 15.227.


Related Submittal(s)/Grant(s)
No related submittal(s).


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.

Measurement uncertainty with radiated emission is 5.81 dB for 30MHz-1GHz, and 4.88 dB for above
1GHz, 1.95dB for conducted measurement.


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 342867, the FCC Designation No. : CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15.227                                                                                    Page 3 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)          Report No.: RSZ181220832-00


SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a typical mode.


EUT Exercise Software
No exercise software was used.


Equipment Modifications
No modifications.


Block Diagram of Test Setup




                                                                   1.0 Meter
                                              EUT




             Non-Conductive Table
             80 cm above Ground Plane


                                             1.5 Meters




FCC Part 15.227                                                                Page 4 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                     Report No.: RSZ181220832-00

SUMMARY OF TEST RESULTS

                  FCC Rules               Description of Test            Result

                   §15.203                Antenna requirement          Compliance

                   §15.207               Conducted Emissions          Not Applicable
            §15.205, §15.209,         Field Strength and Restricted
                                                                       Compliance
          §15.227(a), §15.227(b)             Band Emissions
                  §15.215(c)           20dB Emission Bandwidth         Compliance

      Not Applicable: The EUT is powered by battery.




FCC Part 15.227                                                                        Page 5 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181220832-00

TEST EQUIPMENT LIST

                                                                     Serial        Calibration    Calibration
     Manufacturer              Description            Model
                                                                    Number            Date         Due Date

   Sonoma instrument            Amplifier             310N           186238        2018-11-12      2019-11-12
    Rohde & Schwarz         EMI Test Receiver          ESCI          101120        2018-01-11      2019-01-11
     Sunol Sciences        Broadband Antenna           JB1         A040904-1       2017-12-22      2020-12-21
          ETS             Passive Loop Antenna         6512           29604        2018-07-14      2021-07-13
          TDK                   Chamber             Chamber A           2#         2016-12-05      2019-12-05
       Ducommun                                     UFA147A-       MFR64639
                                RF Cable                                           2018-07-11      2021-07-10
      technologies                                 2362-100100     231029-003
       Ducommun
                                RF Cable             104PEA        218124002       2018-11-12      2019-11-12
      technologies

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
 been performed in accordance to requirements that traceable to National Primary Standards and International
 System of Units (SI).




FCC Part 15.227                                                                                     Page 6 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ181220832-00

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connector Construction
The EUT has an integral antenna arrangement, which was permanently attached and the antenna gain is
0 dBi; fulfill the requirement of this section. Please refer to EUT photos.

Result: Compliant.




FCC Part 15.227                                                                                Page 7 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ181220832-00

FCC§15.205, §15.209, §15.227(a), §15.227 (b) – FIELD STRENGTH AND
RESTRICTED BAND EMISSIONS
Applicable Standard
According to FCC §15.227 (a), the field strength if any emission within this band shall not exceed 10,000
microvolts/meter at 3 meters.

(b) The field strength of any emissions which appear outside of this band shall not exceed the general
radiated emission limits in §15.209.


Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16-4-4, The Treatment of Uncertainty in EMC Measurements, the best estimate of the
uncertainty of a radiation emissions measurement at Bay Area Compliance Laboratories Corp. (Shenzhen)
is 4.0 dB.(k=2, 95% level of confidence), and the uncertainty will not be taken into consideration for all
the test data recorded in the report.


EUT Setup




The radiated emission tests were performed in the 3 meters, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC Part 15.205 and 15.209 and 15.227 limits.



FCC Part 15.227                                                                                Page 8 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181220832-00

EMI Test Receiver Setup
The system was investigated from 9 kHz to 1000 MHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the
Amplifier Gain from the Meter reading. The basic equation is as follows:

          Corrected Amplitude = Meter Reading + Correction Factor
          Correction Factor = Antenna Loss + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

          Margin = Limit – Corrected Amplitude

Test Data
     Environmental Conditions

              Temperature:            25 ℃
          Relative Humidity:          52 %
             ATM Pressure:          101.5 kPa

    Testing was performed by Shawn Xiao on 2018-12-24.

    Test mode: Transmitting (Scan with X-AXIS, Y-AXIS, Z-AXIS, the worst case was recorded)

                                                                    FCC Part
Frequency Corrected            Turntable Rx Antenna Corrected
                                                              15.227&15.205&15.209
          Amplitude PK/QP/Ave.                         Factor                      Remark
                                        Height Polar            Limit     Margin
  (MHz) (dBμV/m)                Degree                 (dB/m)
                                         (m)   (H / V)        (dBμV/m)     (dB)
  27.145       65.78           PK     125       1.0       H        30.3       100        34.22
                                                                                                  Fundamental
  27.145       62.42       Ave.       125       1.0       H        30.3       80         17.58
  0.0093       56.14       Ave.       125       1.0       H        66.7     128.23       72.09
   0.15        49.28       Ave.       125       1.0       H        65.7     104.08       54.80      Spurious
  26.96        39.45           QP     125       1.0       H        30.3      69.54       30.09      Emission

  27.28        38.13           QP     125       1.0       H        30.3      69.54       31.41




FCC Part 15.227                                                                                  Page 9 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                            Report No.: RSZ181220832-00

     30 MHz~1 GHz



                            80



                            70



                            60
                                                                                 Electric Field Strength QP-3m

                            50
          Level in dB¦ÌV/




                            40



                            30



                            20



                            10



                             0
                             30M             50   60      80   100M                200         300      400      500           800     1G
                                                                          Frequency in Hz



                                   Corrected       Antenna                     Turntable       Correction
     Frequency                                                  Antenna                                              Limit            Margin
                                   Amplitude        height                      position        Factor
       (MHz)                                                    Polarity                                           (dBμV/m)            (dB)
                                   (dBμV/m)          (cm)                       (degree)        (dB/m)
     54.294625                       33.89             376.0          H           277.0              -19.9             40.00           6.11
     144.402625                      14.24             100.0          V           22.0               -14.2             43.50           29.26
     585.010875                      20.79             336.0          H           217.0              -2.7              46.00           25.21
     704.247875                      21.24             165.0          V            0.0               -1.1              46.00           24.76
     826.272000                      29.99             173.0          V            0.0                4.5              46.00           16.01
     951.339625                      31.15             155.0          H           288.0               9.9              46.00           14.85

Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor(RX)+cable loss – amplifier factor
Margin = Limit- Corr. Amplitude

Result: Compliance




FCC Part 15.227                                                                                                                      Page 10 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                   Report No.: RSZ181220832-00

                                                             9 KHz-150 KHz
                                                                   * RBW 300 Hz   Marker 1 [T1 ]
                                                                    VBW 1 kHz               56.14 dBµV
                         Ref       130 dBµV       * Att   50 dB     SWT 1.6 s          9.282000000 kHz
                             130
                             9K-150K
                                                                                                          A
                             120

                  1 PK
                  MAXH
                             110


                                                                                                         TDF
                             100


                                                                                                         PS
                             90



                             80

                                                                                                         3DB
                             70                                                                          AC




                         160


                             50



                             40


                             30

                         Start 9 kHz                          14.1 kHz/                   Stop 150 kHz




                  EUT
                  Date: 24.DEC.2018           14:52:10




                                                            150 KHz-30MHz
                                                                   * RBW 10 kHz   Marker 1 [T1 ]
                                                                    VBW 30 kHz              49.28 dBµV
                         Ref       102 dBµV       * Att   20 dB     SWT 300 ms       150.000000000 kHz
                             100
                             150K-30M
                                                                                                          A
                             90
                  1 PK
                  MAXH
                             80

                                                                                                         TDF
                             70



                             60
                                                                                                         PS
                                                                                                               Fundamental
                         1
                             50
                                                                                                         3DB
                                                                                                         AC
                             40



                             30



                             20



                             10



                         Start 150 kHz                       2.985 MHz/                    Stop 30 MHz




                  EUT
                  Date: 24.DEC.2018           15:00:49




FCC Part 15.227                                                                                                        Page 11 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ181220832-00


FCC§15.215(c) - 20dB EMISSION BANDWIDTH
Applicable Standard
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in § 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB
bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section
under which the equipment operates, is contained within the frequency band designated in the rule section
under which the equipment is operated.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.

2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to
   measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
   reference level on the measuring instrument equal to the highest peak value.

3. Measure the frequency difference of two frequencies that indicated 20dB bandwidth.

4. Repeat above procedures until all frequencies measured were complete.


Test Data
     Environmental Conditions

             Temperature:                   25 ℃
       Relative Humidity:                   52 %
           ATM Pressure:                101.0 kPa

    Testing was performed by Shawn Xiao on 2018-12-24.

    Test Mode: Transmitting

     Please refer to the following plots.




FCC Part 15.227                                                                                 Page 12 of 13


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                     Report No.: RSZ181220832-00


                                                                    * RBW 3 kHz    Marker 1 [T1 ]
                                                                     VBW 10 kHz              45.51 dBµV
                         Ref   87 dBµV          * Att   10 dB        SWT 15 ms         27.136600000 MHz

                                                                                   Delta 1 [T1 ]
                         80                                                                   -0.17 dB
                                                                                       17.000000000 kHz     A

                  1 PK
                         70
                  MAXH
                                 D1 65.4 dBµV

                         60                                                                                TDF


                         50                                                                                PS
                                                          1               1
                                    D2 45.4 dBµV

                         40



                         30                                                                                3DB
                                                                                                           AC


                         20



                         10



                         0



                         -10

                         Center 27.145 MHz                      10 kHz/                     Span 100 kHz




                  EUT
                  Date: 24.DEC.2018       14:58:18




              Fl(MHz)                Fh (MHz)                 Permitted frequency range(MHz)                      Result

           27.136600000            27.153600000                               26.96-27.28                        Compliant




                                             ****END OF REPORT****




FCC Part 15.227                                                                                                            Page 13 of 13



Document Created: 2019-03-25 10:01:29
Document Modified: 2019-03-25 10:01:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC