TunePro

FCC ID: 2ADLJZR1

Parts List/Tune Up Info

Download: PDF
FCCID_2457415

                               Tune up procedure
Tune up procedure shall be over the power range or at specific operating power levels.

1. It must provide an operational voltage (3.4 ~ 4.2V DC) to turn on the device and on one certain

  channel in service mode by means of company proprietary software.

2. Base station simulator (CMU 200) measures the mobile phone device specific RF characteristics.

3. The maximum gains of each individual device are adjusted until the target value met.

                                            Tune‐up Power
             Mode                           Frequency Bands                    Tune‐up Power
                                                GSM850                         31.0dBm±1dB
             GSM
                                               GSM1900                         28.5dBm±1dB
                                            GPRS850(1 slots)                   31.0dBm±1dB
                                            GPRS850(2 slots)                   30.0dBm±1dB
                                            GPRS850(3 slots)                   28.0dBm±1dB
                                            GPRS850(4 slots)                   27.0dBm±1dB
             GPRS
                                           GPRS1900(1 slots)                   28.5dBm±1dB
                                           GPRS1900(2 slots)                   27.5dBm±1dB
                                           GPRS1900(3 slots)                   25.5dBm±1dB
                                           GPRS1900(4 slots)                   24.0dBm±1dB
              BT                                 2.4GHz                        3.0dBm±1dB

Then these appropriate gain settings are stored in each device individually.

The user has no possibility to change these settings later on, and during manufacturing each device

will be individual calibrated. The measurement is done in fully calibrated setup, which is based on a

CMU 200 base station simulator. Furthermore, the highest power level is verified afterwards in a call

measurement on three channels (low, middle and high).



Document Created: 2014-11-22 16:57:01
Document Modified: 2014-11-22 16:57:01

© 2024 FCC.report