SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833


                                        RF Exposure Evaluation Report

   1. Product Information

      FCC ID:                                           2ADK3XO-9833
      Product Name                                      Bluetooth Speaker with Wireless Charging Powerbank
      Model Number                                      XO-9833
                                                        DC 3.7V by battery(8000mAh)
      Power Supply
                                                        Recharged by DC 5V/0.5A
      Modulation Type                                   Continuous Wave
      Frequency Range                                   110.0 - 205 KHz
      Operation Frequency                               168.0 KHz
      Maximum Rated Power of WPT                        5W
      Antenna Type                                      Coil Antenna
      Hardware version                                  9833-BK3266-V1.1
      Software version                                  V1.0
      Accessories                                       iPhone X
      Exposure category                                 General population/uncontrolled environment
      EUT Type                                          Production Unit
      Device Type                                       Mobile Device


   2. Evaluation Method

      Per KDB 680106 D01 Section 3. RF Exposure Requirements;
   1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate
      compliance with RF exposure requirements. The potential for exposure must be assessed according to
      the operating configurations of the wireless system and the exposure conditions of users and
      bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at
      maximum output power. The RF exposure requirements must be determined in conjunction with the
      device operating characteristics, according to the mobile and portable exposure requirements in
      Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range
      for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively;
      therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the
      FCC rules.
   2) Based on the design and implementation of the power transfer application, it must be clearly identified
      if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of
      at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some
      conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of
      the rules may apply.
   3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure
      evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength
      measurements or numerical modeling may be used to demonstrate compliance. Measurements should
      be made from all sides and the top of the primary/client pair, with the 15 cm measured from the
      center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be
      assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB
      inquiry is required to determine the applicable exposure limits below 100 kHz.
   4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements.


___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 1 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                          FCC ID: 2ADK3XO-9833

        Existing SAR systems and test procedures are generally intended for measurements above 100 MHz.
        While numerical modeling can be an alternative, the constraints of substantial computational
        resources at low frequencies could introduce further limitations. Under these circumstances, including
        operations below 100 kHz, the Commission may consider a combination of analytical analysis, field
        strength, radiated and conducted power measurements, in conjunction with some limited numerical
        modeling to assess compliance.
   5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be
      adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable
      exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation
      they should contact the FCC Laboratory with sufficient system operating configuration details to
      determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures.
      Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons,
      information on device design, implementation, operating configurations, exposure conditions of users
      and bystanders are needed to determine the evaluation and testing requirements. In addition, the
      influence of nearby objects may also need consideration according to the wireless power transfer
      system implementation; for example, the effects of placing the device, its coils or radiating elements
      on or near metallic surfaces
   6) According to April 2018 TCB Workshop, No need to report E-field measurements. Only H-field required.


   3. Evaluation Limit

   3.1 Refer Evaluation Method

        ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
        Electromagnetic Fields, 3 kHz to 300 GHz.
        FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations
        for Low Power Consumer Wireless Power Transfer Applications
        FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
        FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices
        FCC CFR 47 part 18.107:Indusial, Scientific, and Medical Equipment


   3.2 Limit

          Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                                Limits for Occupational/Controlled Exposure
                   0.3-3.0                     614                      1.63                      *100                        6
                                                                                                         2
                   3.0-30                    1842/f                    4.89/f                   *900/f                        6
                   30-300                     61.4                      0.163                      1.0                        6
                 300-1,500                      /                         /                      f/300                        6
               1,500-100,000                    /                         /                         5                         6




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                          FCC ID: 2ADK3XO-9833

          Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                           Limits for General Population/Uncontrolled Exposure
                  0.3-1.34                     614                      1.63                      *100                         30
                                                                                                         2
                   1.34-30                    824/f                    2.19/f                   *180/f                         30
                   30-300                     27.5                      0.073                      0.2                         30
                 300-1,500                      /                         /                      f/1500                        30
               1,500-100,000                    /                         /                        1.0                         30

          F=frequency in MHz
          *=Plane-wave equivalent power density


          According to FCC KDB 680106 D01 Section 3. RF Exposure Requirements clause 3 the Emission-Limits
          in the frequency range from 100 KHz to 300 KHz should be assessed versus the limits at 300 KHz in
          Table 1 of CFR 47 – Section1.310 as following (measured distance shall be 15cm from the center of
          the probe to the edge of the device):
                                                      E-Field                            */*                           B-Field
                   Frequency                           V/m                              A/m                               uT
              0.3 MHz – 3.0 MHz                         614                            1.613                             2.0
              3.0 MHz – 30 MHz                 824/f (=27.530MHz)               2.19/f (=0.07330MHz)                      --

          A KDB inquire was required to determine/confirm the applicable limits below 100 KHz.


   4. Test Block Diagram of Picture of Two Modes

                                                         Picture of Two Models




                           Supine mode                                                           Pad mode




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 3 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833

   5. Test Setup Diagram




          For mobile RF exposure condition, due to installation limitations no tests from the underside of the
          charging device are required.


   6. Test Equipment

              Equipment              Manufacturer          Model        Serial no.      Calibrated date        Calibrated Due
       Exposure Level Tester              Narda           ELT-400         N-0713          2019-06-17             2020-06-16
            B-Field Probe                 Narda           ELT-400        M-1154           2019-06-17             2020-06-16


   7. Measurement Procedure

          a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
          b) The measurement probe was placed at test distance (15cm and 20cm) which is between the edge
          of the charger and the geometric center of probe.
          c) The turn table was rotated 360d degree to search of highest strength.
          d) The highest emission level was recorded and compared with limit as soon as measurement of each
          points (A, B, C, D, E) were completed.
          e) The EUT were measured according to the dictates of KDB 680106D01v03.




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 4 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833

   8. Equipment Approval Considerations

          The EUT does comply with item 5.2 of KDB 680106 D01v03 as follows table;
    Requirements of KDB 680106 D01                              Yes / No      Description
                                                                              The device operate in the frequency range
    Power transfer frequency is less than 1 MHz                 Yes
                                                                              110.0 KHz - 205 KHz
    Output power from each primary coil is less                               The maximum output power of the primary
                                                                Yes
    than 15 watts                                                             coil is 5W.
    The transfer system includes only single
    primary and secondary coils. This includes
    charging systems that may have multiple
                                                                Yes           The transfer system includes only single coil.
    primary coils and clients that are able to detect
    and allow coupling only between individual
    pairs of coils.
    Client device is placed directly in contact with                          Client device is placed directly in contact
                                                                Yes
    the transmitter.                                                          with the transmitter.
    Mobile exposure conditions only (portable
    exposure conditions are not covered by this                 Yes           Mobile exposure conditions only
    exclusion).
    The aggregate H-field strengths at 15 cm                                  The EUT H-field strengths at 15 cm
    surrounding the device and 20 cm above the                                surrounding the device and 20 cm above the
    top surface from all simultaneous transmitting              Yes           top surface from all simultaneous
    coils are demonstrated to be less than 50% of                             transmitting coils are demonstrated to be
    the MPE limit.                                                            less than 50% of the MPE limit.

          In all other cases, unless excluded above, an RF exposure evaluation report must be reviewed and
          accepted through a KDB or PBA inquiry to enable authorization of the equipment. When evaluation is
          required to show compliance; for example, using field strength, power density, SAR measurements or
          computational modeling etc., the specific authorization requirements will be determined based on
          the results of the RF exposure evaluation




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 5 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833

    9. H field Strength

   Test Modes
   TM1          AC/DC Adapter (5V/2A) + EUT + Mobile Phone (Pad mode) (Battery Status: <1%)                            Pre-tested
   TM2          AC/DC Adapter (5V/2A) + EUT + Mobile Phone (Pad mode) (Battery Status: <50%)                           Pre-tested
   TM3          AC/DC Adapter (5V/2A) + EUT + Mobile Phone (Pad mode) (Battery Status: 100%)                           Pre-tested
   TM4          PC Charger + EUT + Mobile Phone (Pad mode) (Battery Status: <1%)                                       Pre-tested
   TM5          PC Charger + EUT + Mobile Phone (Pad mode) (Battery Status: <50%)                                      Pre-tested
   TM6          PC Charger + EUT + Mobile Phone (Pad mode) (Battery Status: 100%)                                      Pre-tested
    Note: All test modes were pre-tested, but we only recorded the worst case in this report.

E-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT
                                            Measured E-Field Strength Values (V/m)                                            FCC
                                                                                                        FCC E-Field
   Charging     Frequency                                                                                                   E-Field
                                   Test          Test           Test           Test         Test         Strength
    Battery       Range                                                                                                    Strength
                                 Position      Position       Position       Position     Position      50% Limits
     Level        (MHz)                                                                                                     Limits
                                    A             B              C              D            E            (V/m)
                                                                                                                            (V/m)
       1%         0.1650           5.447         5.558         5.914          5.767         6.125           307.0            614.0
     50%          0.1650           5.369         5.632         6.028          5.896         6.238           307.0            614.0
     99%          0.1650           5.284         5.774         6.115          5.884         6.225           307.0            614.0

H-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT
                                           Measured H-Field Strength Values (A/m)                         FCC H-Field       FCC H-Field
Charging     Frequency
                                                                            Test                           Strength          Strength
 Battery       Range           Test           Test          Test                            Test
                                                                          Position                        50% Limits          Limits
  Level        (MHz)        Position A      Position B    Position C                      Position E
                                                                             D                              (A/m)             (A/m)
  1%          0.1680           0.145          0.187          0.250           0.217          0.275             0.815             1.63
  50%         0.1680           0.151          0.212          0.205           0.239          0.258             0.815             1.63
  99%         0.1680           0.157          0.206          0.238           0.238          0.263             0.815             1.63

H-Field Strength at 20cm from the top surface of the EUT
  Charging                                         Measured H-Field Strength                  FCC H-Field               FCC H-Field
                    Frequency Range
   Battery                                              Values (A/m)                         Strength 50%             Strength Limits
                         (MHz)
    Level                                                  Test Position E                   Limits (A/m)                 (A/m)
    1%                    0.1680                                0.170                             0.815                    1.63
    50%                   0.1680                                0.164                             0.815                    1.63
    99%                   0.1680                                0.166                             0.815                    1.63




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 6 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833


                                           WPT RF Exposure_Mobile
                  0.9

                  0.8

                  0.7

                  0.6                                                                                   Test Position A_15cm
  H-Field (A/m)




                                                                                                        Test Position B_15cm
                  0.5
                                                                                                        Test Position C_15cm
                  0.4
                                                                                                        Test Position D_15cm
                  0.3                                                                                   Test Position E_15cm
                  0.2                                                                                   50% Limit

                  0.1                                                                                   Test Position E_20cm

                   0
                        1.00%                    50.00%                     99.00%
                                        Charging Battery Level



      10. Test Setup Photos

      10.1 Pad mode




                                                     20cm




                                  Test Position E - Exposure photo from top surface (20cm)
                                                            (TM1)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833




                                                                           15cm




                                  Test Position E - Exposure photo from top surface (15cm)
                                                            (TM1)




                                                            15cm




                                  Test Position A - Exposure photo from side edge surface-Rear
                                                            (TM1)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 8 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833




                                                            15cm




                                  Test Position B - Exposure photo from side edge surface-Left
                                                           (TM1)




                                            15cm




                                 Test Position C - Exposure photo from side edge surface-Front
                                                           (TM1)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 9 of 10


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                         FCC ID: 2ADK3XO-9833




                                                                      15cm




                                 Test Position D - Exposure photo from side edge surface-Right
                                                           (TM1)




   11. Conclusion

          A minimum safety distance of at 15 cm surrounding the device and 20 cm above the top surface of
          the device is required when the device is charging a smart phone. The detected emissions with a
          distance of 15 cm surrounding the device and 20 cm above the top surface of the device are below
          the limitations according to FCC KDB 680106 D01 Section 3. RF Exposure Requirement Clause 3.


                                                       Revision History

               Revision                    Issue Date                          Revisions                     Revised By
                 000                      March 05, 2019                      Initial Issue                  Gavin Liang




                              .........................END OF REPORT.........................




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 10



Document Created: 2019-09-12 13:56:49
Document Modified: 2019-09-12 13:56:49

© 2025 FCC.report