LCS190812001AEB_WPT 18 Report

FCC ID: 2ADK3XO-9672

Test Report

Download: PDF
FCCID_4427081

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB




                                                FCC TEST REPORT
                                                              FOR
                   XING DA INTERNATIONAL ELECTRONICS LIMITED
                              Bluetooth Speaker with Wireless Charging
                                                Test Model: XO-9672



  Prepared for                              :   XING DA INTERNATIONAL ELECTRONICS LIMITED
                                                #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan,
  Address                                   :
                                                Guang Dong, China

  Prepared by                               :   Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
  Address                                   :
                                                Bao’an District, Shenzhen, Guangdong, China
  Tel                                       :   (+86)755-82591330
  Fax                                       :   (+86)755-82591332
  Web                                       :   www.LCS-cert.com
  Mail                                      :   webmaster@LCS-cert.com

  Date of receipt of test sample            :   August 09, 2019
  Number of tested samples                  :   1
  Serial number                             :   Prototype
  Date of Test                              :   August 09, 2019 ~ August 15, 2019
  Date of Report                            :   August 21,2019




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 1 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2ADK3XO-9672          ReportNo.:LCS190812001AEB


                                                     FCC TEST REPORT
                                                  FCC CFR 47 PART 18: 2017
Report Reference No. .................. : LCS190812001AEB

Date of Issue .................................. : August 21,2019

Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                       1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
Address .......................................... :
                                                       Bao'an District, Shenzhen, Guangdong, China
                                                       Full application of Harmonised standards ■
                                                   :
Testing Location/ Procedure ..........                 Partial application of Harmonised standards □
                                                       Other standard testing method □
Applicant’s Name ......................... : XING DA INTERNATIONAL ELECTRONICS LIMITED
                                                       #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan,
Address .......................................... :
                                                       Guang Dong, China
Test Specification
Standard ......................................... : FCC CFR 47 PART 18: 2017
Test Report Form No...................... : LCSEMC-1.0
TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.
Master TRF..................................... : Dated 2011-03

Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes noresponsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
Test Item Description................... : Bluetooth Speaker with Wireless Charging
Trade Mark ..................................... : N/A
Test Model ...................................... : XO-9672

Ratings ........................................... : Input:DC 5V
Result ........................................... : Positive

              Compiled by:                                      Supervised by:                            Approved by:




    Jack Liu / File administrators                       Aking Jin/ Technique principal              Gavin Liang/ Manager




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 2 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB


                                               FCC -- TEST REPORT

                                                                                                July 03, 2019
     Test Report No. :                        LCS190812001AEB
                                                                                                Date of issue



   Test Model........................           : XO-9672

   EUT....................................      : Bluetooth Speaker with Wireless Charging


   Applicant...........................         : XING DA INTERNATIONAL ELECTRONICS LIMITED
                                                  #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan,
   Address..............................        :
                                                  Guang Dong, China
   Telephone..........................          : /
   Fax.....................................     : /


   Manufacturer.....................            : Dongguan Xing Yue Electronic co., Ltd
                                                  #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan City,
   Address..............................        :
                                                  Guang Dong, China
   Telephone..........................          : /
   Fax.....................................     : /



   Factory..............................        : Dongguan Xing Yue Electronic co., Ltd
                                                  #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan City,
   Address..............................        :
                                                  Guang Dong, China
   Telephone..........................          : /
   Fax.....................................     : /




                               Test Result                                                       Positive


  The test report merely corresponds to the test sample.
  It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 3 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB


                                                 Revision History
         Revision                        Issue Date                          Revisions                        Revised By
           000                         August 21,2019                       Initial Issue                     Gavin Liang




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 4 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                     FCC ID: 2ADK3XO-9672                     ReportNo.:LCS190812001AEB


                                                  TABLE OF CONTENTS
   1. GENERAL INFORMATION........................................................................................................... 6
      1.1 Description of Device (EUT)................................................................................................................. 6
      1.2 Support equipment List ......................................................................................................................... 6
      1.3 External I/O Cable ................................................................................................................................. 6
      1.4 Description of Test Facility ................................................................................................................... 6
      1.5 Statement of the Measurement Uncertainty ...................................................................................... 7
      1.6 Measurement Uncertainty .................................................................................................................... 7
      1.7 Description of Test Modes .................................................................................................................... 7
   2. TEST METHODOLOGY ................................................................................................................ 8
      2.1 EUT Configuration ................................................................................................................................. 8
      2.2 EUT Exercise .......................................................................................................................................... 8
      2.3 General Test Procedures...................................................................................................................... 8
      2.3.1 Conducted Emissions ........................................................................................................................ 8
      2.3.2 Radiated Emissions ........................................................................................................................... 8
   3. SYSTEM TEST CONFIGURATION ............................................................................................. 9
      3.1 Justification ............................................................................................................................................. 9
      3.2 EUT Exercise Software ......................................................................................................................... 9
      3.3 Special Accessories .............................................................................................................................. 9
      3.4 Block Diagram/Schematics .................................................................................................................. 9
      3.5 Equipment Modifications....................................................................................................................... 9
      3.6 Test Setup ............................................................................................................................................... 9
   4. SUMMARY OF TEST EQUIPMENT .......................................................................................... 10
   5. SUMMARY OF TEST RESULT.................................................................................................. 11
   6. POWER LINE CONDUCTED MEASUREMENT ..................................................................... 12
   7. RADIATED EMISSION MEASUREMENT ................................................................................ 14
      7.1. Block Diagram of Test Setup ............................................................................................................ 14
      7.2. Radiated Emission Limit .................................................................................................................... 14
      7.3. EUT Configuration on Measurement ............................................................................................... 15
      7.4. Operating Condition of EUT .............................................................................................................. 15
      7.5. Measuring Setting ............................................................................................................................... 15
      7.6. Test Procedure .................................................................................................................................... 15
      7.7. Test Results ......................................................................................................................................... 16
   8. PHOTOGRAPHS OF TEST SETUP.......................................................................................... 19
   9. EXTERNAL PHOTOGRAPHS OF THE EUT........................................................................... 19
   10. INTERNAL PHOTOGRAPHS OF THE EUT.......................................................................... 19




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                        Page 5 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB


1. GENERAL INFORMATION
  1.1 Description of Device (EUT)

   EUT                                     : Bluetooth Speaker with Wireless Charging
   Test Model                              : XO-9672
   Power Supply                            : Input: DC 5V
   Hardware version                        :/
   Software version                        :/
   Bluetooth
   Bluetooth Operation frequency : 2402MHz-2480MHz
   Bluetooth Version                       : V5.0
   Bluetooth Channel Number                : 79 Channels for Bluetooth V5.0 (BDR/EDR)
   Bluetooth Channel Spacing               : 1MHz for Bluetooth V5.0 (BDR/EDR)
   Bluetooth Modulation Type               : GFSK, π/4-DQPSK 8-DPSK for Bluetooth V5.0(BDR/EDR)
   Antenna Description                     : PCB Antenna, 0dBi
   Wireless Charging
   Operating Frequency                     : 110.0~205.0KHz
   Modulation Type                         : Continuous Wave
   Antenna Type                            : Coil Antenna


  1.2 Support equipment List

          Manufacturer              Description                 Model                  Serial Number           Certificate
            Apple                  iPhone 8 plus             iPhone 8 plus                    --                FCC ID
           Bushnell                  ADAPTOR                SJB0501000PU                      --                 SDOC
   Note: product sales without adapter


  1.3 External I/O Cable

              I/O Port Description                          Quantity                                 Cable
                   USB Port                                   1                                       N/A



  1.4 Description of Test Facility
   FCCRegistrationNumber is254912.
   IndustryCanadaRegistrationNumberis9642A-1.
   EMSDRegistrationNumberisARCB0108.
   ULRegistrationNumberis100571-492.
   TUVSUDRegistrationNumberisSCN1081.
   TUVRHRegistrationNumberisUA50296516-001.
   NVLAPAccreditationCodeis600167-0.
   FCCDesignationNumberisCN5024
   CAB identifier: CN0071
   The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR

 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 6 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB

   16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.
  1.5 Statement of the Measurement Uncertainty
   The data and results referenced in this document are true and accurate. The reader is cautioned that
   there may be errors within the calibration limits of the equipment and facilities. The measurement
   uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
   “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
   Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN
   ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
   result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
   the device.


  1.6 Measurement Uncertainty

                   Test Item                       FrequencyRange                       Uncertainty                Note
                                                    9KHz~30MHz                           3.10dB                     (1)
                                                   30MHz~200MHz                          2.96dB                     (1)
           Radiation Uncertainty           :      200MHz~1000MHz                         3.10dB                     (1)
                                                   1GHz~26.5GHz                          3.80dB                     (1)
                                                   26.5GHz~40GHz                         3.90dB                     (1)
          Conduction Uncertainty :                 150kHz~30MHz                          1.63dB                     (1)
            Power disturbance    :                 30MHz~300MHz                          1.60dB                     (1)

   (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95%
   confidence level using a coverage factor of k=2.

  1.7 Description of Test Modes

   Equipment under test was operated during the measurement under the following conditions:
        Charging mode
   Modulation Type: CW (Continuous Wave)

  Test Modes:
              AC/DC Adapter (5V) + EUT(BT+ Wireless Charging) + MobilePhone (Battery
  Mode 1                                                                                    Record
              Status: <1%)
              AC/DC Adapter (5V) + EUT(BT+ Wireless Charging) + MobilePhone (Battery
  Mode 2                                                                                    Pre-tested
              Status: <50%)
              AC/DC Adapter (5V) + EUT(BT+ Wireless Charging) + MobilePhone (Battery
  Mode 3                                                                                    Pre-tested
              Status: 100%)
  Mode 4 AC/DC Adapter (5V) + EUT+ MobilePhone (Battery Status: <1%)                        Pre-tested
  Mode 5 AC/DC Adapter (5V) + EUT + MobilePhone (Battery Status: <50%)                      Pre-tested
  Mode 6 AC/DC Adapter (5V) + EUT + MobilePhone (Battery Status: 100%)                      Pre-tested
  Mode 7 AC/DC Adapter (5V) + EUT(BT)
  Note: All test modes were pre-tested, but we only recorded the worst case in this report.


   For AC conducted emission, pre-test at both AC 120V/60Hz and AC 240V/50Hz, recorded worst case;
   For AC conducted emission, pre-test at both AC charge from power adapter and PC modes, recorded
   worst case.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 7 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB




2. TEST METHODOLOGY
   The tests documented in this report were performed in accordance with MP-5, and FCC CFR PART 18.

  2.1 EUT Configuration
   The EUT configuration for testing is installed on RF field strength measurement to meet the
   Commissions requirement and operating in a manner that intends to maximize its emission
   characteristics in a continuous normal application.

  2.2 EUT Exercise
   The EUT was operated in the charging and compunction mode to fix the TX frequency that was for the
   purpose of the measurements.
   According to its specifications, the EUT must comply with the requirements of the Section 18.305 and
   18.307under the FCC Rules Part 18.

  2.3 General Test Procedures

  2.3.1Conducted Emissions
   The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements
   in FCC MP-5 forConducted emissions from the EUT measured in the frequency range between 0.15
   MHz and 30MHz using Quasi-peak and average detector modes.

  2.3.2Radiated Emissions
   The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
   degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
   antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to
   be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to
   find out the maximum emissions, exploratory radiated emission measurements were made according to
   the requirements in FCC MP-5 for radiated emission.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 8 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB



3. SYSTEM TEST CONFIGURATION

  3.1 Justification
   The system was configured for testing in a normal condition.

  3.2 EUT Exercise Software
   N/A.

  3.3 Special Accessories


                                                                                                          shielded/
 No.        Equipment           Manufacturer         Model No.             Serial No.      Length                          Notes
                                                                                                         unshielded
  1               --                    --                 --                  --              --             --              --
  2               --                    --                 --                  --              --             --              --

  3.4 Block Diagram/Schematics
   Please refer to the related document.

  3.5 Equipment Modifications
   Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6 Test Setup
   Please refer to the test setup photo.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 9 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB


4. SUMMARY OF TEST EQUIPMENT

Item            Equipment                   Manufacturer         Model No.         Serial No.          Cal Date           Due Date
                                                                                  MY4910004
 1        MXA Signal Analyzer                   Agilent           N9020A                              2019-06-11         2020-06-10
                                                                                       0
 2     SPECTRUM ANALYZER                       R&S                 FSP40            100503            2018-11-15         2019-11-14
         3m Semi Anechoic                      SIDT
 3                                                                SAC-3M          03CH03-HY           2019-06-12         2020-06-11
              Chamber                      FRANKONIA
 4      Positioning Controller                  MF MF-7082       /     2019-06-12 2020-06-11
 5       EMI Test Software                    AUDIX   E3         /        N/A         N/A
 6       EMI Test Receiver                     R&S  ESR 7     101181   2019-06-12 2020-06-11
                                           SCHWARZBEFMZB
 7        Active Loop Antenna                                 00005    2019-07-25 2020-07-24
                                                CK  1519B
                                           SCHWARZBE
                                                  VULB916
 8          By-log Antenna                                   9163-470  2019-07-25 2020-07-24
                                                CK    3
                                           SCHWARZBEBBHA
 9           Horn Antenna                                   9120D-1925 2019-07-01 2020-06-30
                                                CK  9120D
 10         RF Cable-R03m                    Jye BaoRG142     CB021    2019-06-12 2020-06-11
                                                  SUCOFLE
 11         RF Cable-HIGH             SUHNER                03CH03-HY 2019-06-12 2020-06-11
                                                    X 106
 12        EMI Test Receiver            R&S          ESPI     101840   2019-06-11 2020-06-10
 13          Artificial Mains           R&S        ENV216     101288   2019-06-12 2020-06-11
                                    SCHWARZBE MTS-IMP- 261115-001-
 14         10dB Attenuator                                            2019-06-11 2020-06-10
                                         CK          136       0032
Note: All equipment is calibrated through CHINA CEPREI LABORATORY and GUANGZHOU LISAI
CALIBRATION AND TEST CO., LTD.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 10 of 19


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB


5. SUMMARY OF TEST RESULT

                         FCC Rule         Temperature          Power source
   Test Item                                                                         C        NC          NA         NP        Remark
                           No.             conditions           conditions
   Radiated
                        §18.305 (b)          Nominal              Nominal                                                         -/-
   Emission
 AC conducted
                        §18.307 (b)          Nominal              Nominal                                                         -/-
   emission

Remark: The measurement uncertainty is not included in the test result.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 11 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB


6. POWER LINE CONDUCTED MEASUREMENT

  6.1. Block Diagram of Test Setup


                                                       Vert. reference
                                                          plane
                                                                                                 EMI receiver




                                           EUT




                   LISN                                              Reference ground plane




  6.2.Standard Applicable

  According to §18.307 (b): For all other part 18 consumer deviceswhich is designed to be connected to the
  public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line
  on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The
  limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits
  at specific frequency range are listed as follows:

         Frequency Range                                                    Limits (dBμV)
               (MHz)                                   Quasi-peak                                      Average
            0.15 to 0.50                                66 to 56                                       56 to 46
             0.50 to 5                                     56                                             46
              5 to 30                                      60                                             50

  * Decreasing linearly with the logarithm of the frequency


  6.3 Test Results
   PASS.
   The test data please refer to following page.




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 12 of 19


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 13 of 19


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB



7. RADIATED EMISSION MEASUREMENT

   7.1. Block Diagram of Test Setup




   7.2. Radiated Emission Limit

     Except as provided elsewhere in this Subpart 18.305 (b), the field strength levels of emissions which lie
     outside the bands specified in §18.301, unless otherwise indicated, shall not exceed the following table:


                     Frequency                         Distance                       Field Strengths Limit
                         MHz                            Meters                    dBµV/m              Remark
                   0.009~30MHz                             3                       103.5            Quasi-peak
                       30~88                               3                        40.0            Quasi-peak
                      88~216                               3                        43.5            Quasi-peak
                       216~960                             3                        46.0            Quasi-peak
                      960~1000                             3                        54.0            Quasi-peak

Remark:
(1) Emission level dBµV/m for 0.009~30MHz = 20log (15)+ 40log (300/3) dBµV/m;
(2) Calculated according FCC 18.305.
(3) The smaller limit shall apply at the cross point between two frequency bands.
(4) Distance is the distance in meters between the measuring instrument, antenna and the closest point of
any part of the device or system.


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 14 of 19


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB

   7.3. EUT Configuration on Measurement

The following equipment are installed on Radiated Emission Measurement to meet the commission
requirements and operating regulations in a manner which tends to maximize its emission characteristics in
normal application.

   7.4. Operating Condition of EUT

(1) Setup the EUT as shown in Section 4.1.
(2) Let the EUT work in worst test mode (Mode 1) and measure it.

   7.5. Measuring Setting
     The following table is the setting of spectrumanalyzer and receiver.

          Receiver Parameter                                     Setting
          Attenuation                                            Auto
          Start ~ Stop Frequency                                 9kHz~150kHz / RB 120Hz for QP/Average
          Start ~ Stop Frequency                                 150kHz~30MHz / RB 9kHz for QP/Average
          Start ~ Stop Frequency                                 30MHz~1000MHz / RB 100kHz for QP


   7.6. Test Procedure
     1) Sequence of testing 9 kHz to 30 MHz
     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or described
     by manufacturer.
     --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
     --- If the EUT is a floor standing device, it is placed on the ground.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.
     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna height is 0.8 meter.
     --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
     emissions
     Final measurement:
     --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
     position (0° to 360°) and by rotating the elevation axes (0° to 360°).
     --- The final measurement will be done in the position (turntable and elevation) causing the highest
     emissions with QP detector.
     --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin
     to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will
     be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 15 of 19


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB




     2) Sequence of testing 30 MHz to 1 GHz
     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or described
     by manufacturer.
     --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
     plane.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.
     Premeasurement:
     --- The turntable rotates from 0° to 315° using 45° steps.
     --- The antenna is polarized vertical and horizontal.
     --- The antenna height changes from 1 to 3 meter.
     --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak
     to find the maximum of all emissions.
     Final measurement:
     --- The final measurement will be performed with minimum the six highest peaks.
     --- According to the maximum antenna and turntable positions of premeasurement the software
     maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
     meter.
     --- The final measurement will be done with QP detector with an EMI receiver.
     --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
     turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph
     of the premeasurement with marked maximum final measurements and the limit will be stored.


   7.7. Test Results

PASS.

Only report the worst test data (Mode 1) in test report;

The test data please refer to following page:




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 16 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB

0.009 MHz – 30 MHz




Remark:

Measured at 0 degree and 90 degree, recorded worst case at 90 degree.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 17 of 19


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB

30 MHz – 1000 MHz

Horizontal




Vertical




Note:
     1). Pre-scan all modes and recorded the worst case results in this report.
     2). Emission level (dBuV/m) = 20 log Emission level (uV/m).
     3). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 18 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2ADK3XO-9672              ReportNo.:LCS190812001AEB



8. PHOTOGRAPHS OF TEST SETUP

   Please refer to separated files for Test Setup Photos of the EUT.


9. EXTERNALPHOTOGRAPHS OF THE EUT

   Please refer to separated files for External Photos of the EUT.


10. INTERNALPHOTOGRAPHS OF THE EUT

   Please refer to separated files for Internal Photos of the EUT.




                             -------------THE END OF REPORT-------------




 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                            Page 19 of 19



Document Created: 2019-09-03 15:50:26
Document Modified: 2019-09-03 15:50:26

© 2025 FCC.report