RF Exposure Evaluation 8CC

FCC ID: 2ADK3XO-9672

RF Exposure Info

Download: PDF
FCCID_4427068

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA


                                        RF Exposure Evaluation Report

    1. Product Information

      FCC ID:                                           2ADK3XO-9672
      Product Name                                      Bluetooth Speaker with Wireless Charging
      Model Number                                      XO-9672
      Power Supply                                      Input: DC 5V
      Modulation Type                                   WPT: CW (Continuous Wave)
      Frequency Range                                   WPT: 110 – 205 KHz
      WPC Operation Frequency                           150.0 KHz
      Antenna Type                                      WPT: Coil Antenna
      Hardware version                                  /
      Software version                                  /
      Accessories                                       iPhone X
      Exposure category                                 General population/uncontrolled environment
      EUT Type                                          Production Unit
      Device Type                                       Mobile device


    2. Evaluation Method

                According to KDB447498 D01 General RF Exposure Guidance v06Section 4.3.1 Standalone SAR
          test exclusion considerations: “Unless specifically required by the published RF exposure KDB
          procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population
          exposure conditions, by measurement or numerical simulation, is not required when the
          corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion
          conditions are based on source-based time-averaged maximum conducted output power of the RF
          channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation
          distance required for the exposure conditions. The minimum test separation distance is determined
          by the smallest distance from the antenna and radiating structures or outer surface of the device,
          according to the host form factor, exposure conditions and platform requirements, to any part of the
          body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the
          test separation distances applied must be fully explained and justified by the operating configurations
          and exposure conditions of the transmitter and applicable host platform requirements, typically in
          the SAR measurement or SAR analysis report, according to the required published RF exposure KDB
          procedures. When no other RF exposure testing or reporting is required, a statement of justification
          and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for
          the SAR test exclusion. When required, the device specific conditions described in the other
          published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion
          provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.“
          [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] · [√f
          (GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where:
          • f (GHz) is the RF channel transmit frequency in GHz
          • Power and distance are rounded to the nearest mW and mm before calculation
          • The result is rounded to one decimal place for comparison
          • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
           The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
           for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation

___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 1 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA

            distance is < 5 mm, a distance of 5 mm according to f) in section 4.1 is applied to determine SAR test
            exclusion.

            When one of the following test exclusion conditions is satisfied for all combinations of simultaneous
            transmission configurations, further equipment approval is not required to incorporate transmitter
            modules in host devices that operate in the mixed mobile and portable host platform exposure
            conditions. The grantee is responsible for documenting this according to Class I permissive change
            requirements. Antennas that qualify for standalone SAR test exclusion must apply the estimated
            standalone SAR to determine simultaneous transmission test exclusion.
            a) The [∑ of (the highest measured or estimated SAR for each standalone antenna configuration,
                adjusted for maximum tune-up tolerance) / 1.6 W/kg] + [∑ of MPE ratios] is ≤ 1.0.
            b) The SAR to peak location separation ratios of all simultaneously transmitting antenna pairs
                operating in portable device exposure conditions are all ≤ 0.04, and the [∑ of MPE ratios] is ≤
                1.0.

    3. Evaluation Limit

    3.1 Refer evaluation method

             ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
             Electromagnetic Fields, 3 kHz to 300 GHz.
             FCC KDB publication 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Devices RF
             Exposure Procedures and Equipment Authorization Policies.
             FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
             FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices
    3.2 Limit

          Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                                Limits for Occupational/Controlled Exposure
                   0.3-3.0                     614                      1.63                      *100                        6
                   3.0-30                    1842/f                    4.89/f                   *900/f2                       6
                   30-300                     61.4                      0.163                      1.0                        6
                 300-1,500                      /                         /                      f/300                        6
               1,500-100,000                    /                         /                         5                         6




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672          Report No.: LCS190812001AEA

          Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                 Frequency               Electric Field           Magnetic Field            Power Density            Averaging Time
                Range(MHz)              Strength(V/m)             Strength(A/m)               (mW/cm²)                  (minute)
                                           Limits for General Population/Uncontrolled Exposure
                  0.3-1.34                     614                      1.63                      *100                         30
                   1.34-30                    824/f                    2.19/f                    *180/f   2
                                                                                                                               30
                   30-300                     27.5                      0.073                      0.2                         30
                 300-1,500                      /                         /                      f/1500                        30
               1,500-100,000                    /                         /                        1.0                         30

          F=frequency in MHz
          *=Plane-wave equivalent power density


          According to FCC KDB 680106 D01 Section 3. RF Exposure Requirements clause 3 the Emission-Limits
          in the frequency range from 100 KHz to 300 KHz should be assessed versus the limits at 300 KHz in
          Table 1 of CFR 47 – Section1.310 as following (measured distance shall be 15cm from the center of
          the probe to the edge of the device):
                                                      E-Field                            */*                           B-Field
                   Frequency                           V/m                              A/m                               uT
              0.3 MHz – 3.0 MHz                         614                            1.613                             2.0
              3.0 MHz – 30 MHz                 824/f (=27.530MHz)               2.19/f (=0.07330MHz)                      --

          A KDB inquire was required to determine/confirm the applicable limits below 100 KHz.




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 3 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA



    4. Test Setup Diagram




    5. Test Equipment

           Equipment              Manufacturer          Model           Serial no.       Calibrated date         Calibrated Due
    Exposure Level Tester             Narda            ELT-400           N-0713             2019-04-02             2020-04-01
         B-Field Probe                Narda            ELT-400           M-1154             2019-04-11             2020-04-10


    6. RF Exposure Evaluation

    6.1 Standalone WPC Evaluation

    6.1.1 Measurement Procedure

          a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
          b) The measurement probe was placed at test distance (15cm) which is between the edge of the
          charger and the geometric center of probe.
          c) The turn table was rotated 360d degree to search of highest strength.
          d) The highest emission level was recorded and compared with limit as soon as measurement of each
          points (A, B, C, D, E) were completed.
          e) The EUT were measured according to the dictates of KDB 680106D01v03.




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 4 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA

    6.1.2 Equipment Approval Considerations

   The EUT does comply with item 5.2 of KDB 680106 D01v02 as follows table;
    Requirements of KDB 680106 D01                               Yes / No       Description
                                                                                The device operate in the frequency range
    Power transfer frequency is less than 1 MHz                  Yes
                                                                                110.0 KHz - 205.0 KHz
    Output power from each primary coil is less                                 The maximum output power of the
                                                                 Yes
    than 15 watts                                                               primary coil is less than 15W.
    The transfer system includes only single primary
                                                                                The transfer system includes one primary
    and secondary coils. This includes charging
                                                                                coils and clients that are able to detect and
    systems that may have multiple primary coils                 Yes
                                                                                allow coupling only between individual
    and clients that are able to detect and allow
                                                                                pairs of coils.
    coupling only between individual pairs of coils.
    Client device is placed directly in contact with                            Client device is placed directly in contact
                                                                 Yes
    the transmitter.                                                            with the transmitter.
    Mobile exposure conditions only (portable
    exposure conditions are not covered by this                  Yes            Mobile exposure conditions only
    exclusion).
    The aggregate H-field strengths at 15 cm                                    The aggregate H-field strengths at 15 cm
    surrounding the device and 20 cm above the top                              surrounding the device and 20 cm above
    surface from all simultaneous transmitting coils             Yes            the top surface from all simultaneous
    are demonstrated to be less than 50% of the                                 transmitting coils are less than 50% the
    MPE limit.                                                                  MPE limit.

        In all other cases, unless excluded above, an RF exposure evaluation report must be reviewed and
        accepted through a KDB or PBA inquiry to enable authorization of the equipment. When evaluation is
        required to show compliance; for example, using field strength, power density, SAR measurements or
        computational modeling etc., the specific authorization requirements will be determined based on the
        results of the RF exposure evaluation.


    6.1.3 E and H field Strength

        Operate mode:
    Test Modes:
    TM1          AC/DC Adapter + EUT + Electric Silicone Cleansing Instrument (Battery Status: <1%)                      Record
    TM2          AC/DC Adapter + EUT + Electric Silicone Cleansing Instrument (Battery Status: <50%) Pre-tested
    TM3          AC/DC Adapter + EUT + Electric Silicone Cleansing Instrument (Battery Status: 100%) Pre-tested
    TM4          EUT + Electric Silicone Cleansing Instrument (Battery Status: <1%)                                      Record
    TM5          EUT + Electric Silicone Cleansing Instrument (Battery Status: <50%)                                   Pre-tested
    TM6          EUT + Electric Silicone Cleansing Instrument (Battery Status: 100%)                                   Pre-tested
    Note: All test modes were pre-tested, but we only recorded the worst case in this report.




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 5 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672           Report No.: LCS190812001AEA

E-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT
                                                  Measured E-Field Strength Values (V/m)                      FCC E-Field
           Charging      Frequency                                                                                            FCC E-Field
Operate                                   Test          Test          Test         Test           Test         Strength
            Battery        Range                                                                                                Strength
 mode                                   Position      Position      Position     Position       Position      50% Limits
             Level         (MHz)                                                                                              Limits(V/m)
                                           A             B             C            D              E            (V/m)
              1%           0.150           5.83          5.17         5.52         5.33           6.42           307.0          614.0
 TM1         50%           0.150           5.48          5.25         5.46         4.67           5.65           307.0          614.0
             99%           0.150           5.37          4.61         5.38         4.59           5.72           307.0          614.0
              1%           0.150           5.57          5.38         5.74         5.42           6.62           307.0          614.0
 TM4         50%           0.150           5.48          5.29         5.61         5.14           5.78           307.0          614.0
             99%           0.150           5.27          5.67         5.15         4.96           5.54           307.0          614.0

H-Field Strength at 15 cm from the edges surrounding the EUT and 15cm from the top surface of the EUT
                                                    Measured H-Field Strength Values (A/m)                           FCC          FCC
            Charging      Frequency                                                                                H-Field      H-Field
 Operate                                    Test          Test          Test           Test          Test
             Battery        Range                                                                                 Strength     Strength
  mode                                    Position      Position      Position       Position      Position
              Level         (MHz)                                                                                50% Limits     Limits
                                             A             B             C              D             E
                                                                                                                   (A/m)        (A/m)
               1%            0.150          0.107        0.092         0.106          0.114         0.123          0.815         1.63
  TM1          50%           0.150          0.096        0.094         0.103          0.096         0.128          0.815         1.63
               99%           0.150          0.081        0.085         0.074          0.078         0.113          0.815         1.63
               1%            0.150          0.109        0.092         0.112          0.113         0.155          0.815         1.63
  TM4          50%           0.150          0.104        0.089         0.104          0.103         0.164          0.815         1.63
               99%           0.150          0.092        0.079         0.076          0.084         0.132          0.815         1.63

H-Field Strength at 20cm from the top surface of the EUT
                                                           Measured H-Field Strength                FCC H-Field            FCC H-Field
 Operate       Charging          Frequency Range
                                                                Values (A/m)                       Strength 50%          Strength Limits
  mode       Battery Level            (MHz)
                                                                   Test Position E                  Limits (A/m)             (A/m)
                   1%                   0.150                           0.097                            0.815                1.63
  TM1              50%                  0.150                           0.092                            0.815                1.63
                   99%                  0.150                           0.088                            0.815                1.63
                   1%                   0.150                           0.097                            0.815                1.63
  TM4              50%                  0.150                           0.112                            0.815                1.63
                   99%                  0.150                           0.083                            0.815                1.63




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 6 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA

    6.1.4 Test Setup Photos

    6.1.4.1 Test Position E-Exposure photo from top surface(20cm)




                                                   20cm




                                                                (TM1)




                                                   20cm




                                                                (TM4)

___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 7 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA




    6.1.4.2    Test Position E-Exposure photo from top surface (15cm)




                                                           15cm




                                                                   (TM1)




                                                15cm




                                                                (TM4)


___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 8 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA




    6.1.4.3    Test Position A-Exposure photo from side edge surface-Rear




                                                           15cm




                                                                   (TM1)




                                                   15cm




                                                                   (TM4)


___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 9 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA




                                                                              15cm




                                                                   (TM1)




    6.1.4.4 Test Position C-Exposure photo from side edge surface-Front




                                                                                   15cm




                                                                   (TM4)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA




                                                            15cm




                                                                   (TM1)




                                                                15cm




                                                                   (TM4)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 11 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672        Report No.: LCS190812001AEA

    6.1.4.5 Test Position D-Exposure photo from side edge surface-Right




                                            15cm




                                                                   (TM1)




                                                          15cm




                                                                   (TM4)




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 13


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                  FCC ID: 2ADK3XO-9672          Report No.: LCS190812001AEA




                                                       Revision History

           Revision                         Issue Date                          Revisions                        Revised By
             000                           Aug 27, 2019                        Initial Issue                     Gavin Liang




                              .........................END OF REPORT.........................




___________________________________________________________________________
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 13 of 13



Document Created: 2019-09-03 15:48:02
Document Modified: 2019-09-03 15:48:02

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC