                     FCC Test Report

                          Report No.: AGC02724191002FE03




 FCC ID                         : 2ADK3-XO-9757

 APPLICATION PURPOSE            : Original Equipment

 PRODUCT DESIGNATION            : Wireless charging with clock

 BRAND NAME                     : N/A

 MODEL NAME                     : XO-9757

 APPLICANT                      : XING DA INTERNATIONAL ELECTRONICS LIMITED

 DATE OF ISSUE                  : Oct. 28, 2019
 STANDARD(S)
                                : FCC Part 15 Rules
 TEST PROCEDURE(S)
 REPORT VERSION                 : V1.0




       Attestation of Global Compliance (Shenzhen) Co., Ltd

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.


                                                               Report No.: AGC02724191002FE03
                                                                                   Page 2 of 31


                                 REPORT REVISE RECORD

Report Version   Revise Time   Issued Date     Valid Version              Notes

    V1.0              /        Oct. 28, 2019       Valid              Initial Release


                                                                                                                   Report No.: AGC02724191002FE03
                                                                                                                                       Page 3 of 31


                                                               TABLE OF CONTENTS

1. VERIFICATION OF CONFORMITY ........................................................................................................................ 4


2. GENERAL INFORMATION ..................................................................................................................................... 5

   2.1. PRODUCT DESCRIPTION .............................................................................................................................. 5

3. MEASUREMENT UNCERTAINTY .......................................................................................................................... 6


4. DESCRIPTION OF TEST MODES .......................................................................................................................... 7


5. SYSTEM TEST CONFIGURATION ......................................................................................................................... 8

   5.1. CONFIGURATION OF EUT SYSTEM .............................................................................................................. 8
   5.2. EQUIPMENT USED IN EUT SYSTEM .............................................................................................................. 8
   5.3. SUMMARY OF TEST RESULTS ....................................................................................................................... 8

6. TEST FACILITY ...................................................................................................................................................... 9


7. RADIATED EMISSION .......................................................................................................................................... 10

   7.1TEST LIMIT ...................................................................................................................................................... 10
   7.2. MEASUREMENT PROCEDURE .................................................................................................................... 11
   7.3. TEST SETUP.................................................................................................................................................. 12
   7.4. TEST RESULT ................................................................................................................................................ 13

8. 20DB BANDWIDTH .............................................................................................................................................. 16

   8.1. MEASUREMENT PROCEDURE .................................................................................................................... 16
   8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ............................................................................ 16
   8.3. MEASUREMENT RESULTS........................................................................................................................... 17

9. FCC LINE CONDUCTED EMISSION TEST ......................................................................................................... 18

   9.1. LIMITS OF LINE CONDUCTED EMISSION TEST.......................................................................................... 18
   9.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST ....................................................................... 18
   9.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST ..................................................... 19
   9.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST ................................................................... 19
   9.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST.............................................................................. 20

APPENDIX A: PHOTOGRAPHS OF TEST SETUP.................................................................................................. 22


APPENDIX B: PHOTOGRAPHS OF EUT ................................................................................................................ 24


                                                                         Report No.: AGC02724191002FE03
                                                                                             Page 4 of 31


1. VERIFICATION OF CONFORMITY
Applicant                    XING DA INTERNATIONAL ELECTRONICS LIMITED
                             #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong,
Address
                             China
Manufacturer                 XING DA INTERNATIONAL ELECTRONICS LIMITED
                             #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong,
Address
                             China
Factory                      XING DA INTERNATIONAL ELECTRONICS LIMITED
                             #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong,
Address
                             China
Product Designation          Wireless charging with clock
Brand Name                   N/A
Test Model                   XO-9757
Date of test                 Oct. 15, 2019 to Oct. 28, 2019
Deviation                    None
Condition of Test Sample     Normal
Test Result                  Pass
Report Template              AGCRT-US-BR/RF
We hereby certify that:
The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were made in accordance with
the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described
in this report is in compliance with Section 15.207, 15.209, 15.203 of the FCC Part 15, Subpart C Rules.
The results of testing in this report apply to the product/system which was tested only.


                    Prepared By

                                              Jeast Zhan
                                                                         Oct. 28, 2019
                                           (Project Engineer)

                   Reviewed By

                                               Max Zhang
                                                                         Oct. 28, 2019
                                               (Reviewer)

                   Approved By

                                               Forrest Lei
                                                                         Oct. 28, 2019
                                          ( Authorized Officer )


                                                                        Report No.: AGC02724191002FE03
                                                                                            Page 5 of 31


2. GENERAL INFORMATION
2.1. PRODUCT DESCRIPTION
A major technical description of EUT is described as following
Operation Frequency                          110-205 kHz
Test Frequency                               123.6kHz
Maximum field strength                       55.65dBuV/m(PK)@3m
Modulation                                   FSK
Number of channels                           1
Antenna Gain                                 0dBi
Antenna Designation                          Integrated Antenna (Met 15.203 Antenna requirement)
Hardware Version                             XO9757-1 V0

Software Version                             V1.0

Power Supply                                 DC 5V 2A by adapter


                                                                          Report No.: AGC02724191002FE03
                                                                                              Page 6 of 31


3. MEASUREMENT UNCERTAINTY
The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in
measurement” (GUM) published by CISPR and ANSI.
- Uncertainty of Conducted Emission, Uc = ±3.2 dB
- Uncertainty of Radiated Emission below 1GHz, Uc = ±3.9 dB
- Uncertainty of Radiated Emission above 1GHz, Uc = ±4.8 dB


                                                                          Report No.: AGC02724191002FE03
                                                                                              Page 7 of 31


4. DESCRIPTION OF TEST MODES
      NO.                                         TEST MODE DESCRIPTION
        1                                      Wireless charging Mode(Full load)
        2                                      Wireless charging Mode(half load)
        3                                      Wireless charging Mode(Null load)

Note:
1. The mode 1 was the worst case and only the data of the worst case record in this report.


                                                                  Report No.: AGC02724191002FE03
                                                                                      Page 8 of 31


5. SYSTEM TEST CONFIGURATION
5.1. CONFIGURATION OF EUT SYSTEM
Configure :



                EUT             Accessory




5.2. EQUIPMENT USED IN EUT SYSTEM
Item        Equipment        Model No.           ID or Specification               Remark

         Wireless charging
  1                          XO-9757              2ADK3-XO-9757                      EUT
            with clock


  2              Load          N/A                       5W                       Accessory


  3             Adapter        N/A                     DC 5V 2A                   Accessory


  4         USB Cable          N/A                1.0m, Unshielded                Accessory



5.3. SUMMARY OF TEST RESULTS

  FCC RULES                     DESCRIPTION OF TEST                               RESULT
      §15.209                      Radiated Emission                              Compliant
      §15.215                        20dB bandwidth                               Compliant
      §15.207                     Conducted Emission                              Compliant


                                                                      Report No.: AGC02724191002FE03
                                                                                          Page 9 of 31


6. TEST FACILITY
     Test Site         Attestation of Global Compliance (Shenzhen) Co., Ltd
                       1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community,
     Location
                       Fuhai Street, Bao'an District, Shenzhen, Guangdong, China
Designation Number     CN1259
  FCC Test Firm
                       975832
Registration Number
  A2LA Cert. No.       5054.02
    Description        Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by A2LA


TEST EQUIPMENT OF CONDUCTED EMISSION TEST
    Equipment          Manufacturer        Model             S/N              Cal. Date     Cal. Due
 TEST RECEIVER             R&S              ESPI            101206       Jun.12, 2019      Jun.11, 2020
      LISN                 R&S            ESH2-Z5          100086        Aug. 26, 2019    Aug. 25, 2020


TEST EQUIPMENT OF RADIATED EMISSION TEST
  Equipment           Manufacturer        Model             S/N           Cal. Date         Cal. Due
TEST RECEIVER             R&S              ESCI           10096         Jun.12, 2019      Jun.11, 2020
   EXA Signal
                         Aglient         N9010A        MY53470504       Dec. 20, 2018     Dec. 19, 2019
    Analyzer
   Active loop
    antenna             ZHINAN          ZN30900C          18051         Jun.12, 2019      Jun.11, 2020
  (9K-30MHz)
   ANTENNA         SCHWARZBECK          VULB9168            494         Jan. 09, 2019     Jan. 08, 2021


AGC                                                                                      Report No.: AGC02724191002FEO3
                                                                                                                     Page 10 of 31


7. RADIATED EMISSION
7ATEST LIMIT
Standard FCC 15.209

Frequency                     Distance                                               Field Strengths Limit
(MHz)                         Meters                             4 V/m                                dB(pV)/m
0.009 ~ 0.490                 300                                2400/F(kHz)
0.490 ~ 1.705                 30                                 24000/F (kHz)
1.705 ~ 30                    30                                 30
30 ~ 88                       3                                  100                                  40.0
88 ~ 216                      3                                  150                                  43.5
216 ~ 960                     3                                  200                                  46.0
960 ~ 1000                    3                                  500                                  54.0
Above      1000               3                                  Other:74.0 dB(uV)/m (Peak) 54.0 dB(uV)/m (Average)
Remark:       (1) Emission level dBuV = 20 log Emission level uV/m
              (2) The smaller limit shall apply at the cross point between two frequency bands.
              (3) Distance is the distance in meters between the measuring instrument, antenna and the closest
                  point of any part of the device or system.




                                         Attestation of Global Compliance(Shenzhen)Co.,Ltd.
                                         Add: 2/F., Building 2,Sanwei Chaxi Industrial Park, Sanwei Community,
                                              Hangcheng Street, Bao‘an District, Shenzhen, Guangdong, China
                                         Tel: +86—755 2523 4088        E—mail: agc@age—cert.com         Service Hotline:400 089 2118


                                                                          Report No.: AGC02724191002FE03
                                                                                             Page 11 of 31


7.2. MEASUREMENT PROCEDURE
  1. The EUT was placed on the top of the turntable 0.8 or 1.5 meter above ground. The phase center of the
     receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away
     from the turntable.
  2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
     the position of the highest radiation.
  3. The height of the broadband receiving antenna was varied between one meter and four meters above
     ground to find the maximum emissions field strength of both horizontal and vertical polarization.
  4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
     rotated (from 0 degree to 360 degrees) to find the maximum reading.
  5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
     under Maximum Hold Mode.
  6. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
       recorded data should be QP measured by receiver. High - Low scan is not required in this case.



The following table is the setting of spectrum analyzer and receiver.
                Spectrum Parameter                                            Setting
                Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                Receiver    Parameter                                         Setting
                Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                                                           Report No.: AGC02724191002FE03
                                                                              Page 12 of 31


7.3. TEST SETUP
                  Radiated Emission Test-Setup Frequency Below 30MHz




                   RADIATED EMISSION TEST SETUP 30MHz-1000MHz


                                                                               Report No.: AGC02724191002FE03
                                                                                                  Page 13 of 31


7.4. TEST RESULT
                                     RADIATED EMISSION BELOW 30MHZ

                                 Reading          Factor          Level          Limit
Frequency                                                                                      Margin
               Polarization      dB(uV)            dB           dB(uV/m)       dB(uV/m)                   Pass/Fail
   MHz                                                                                          dB
                                   PK             (1/m)            PK             PK
  0.1236           Face           45.25           10.40           55.65          105.76        -50.11        Pass
  0.1236           Side           35.18           10.40           45.58          105.76        -60.18        Pass

Note1: No other emissions found between lowest internal used/generated frequencies to 30MHz. The peak
level of the emission is less than the average limit, so the average level shall be less than the limit without test.
Note 2: Level(dBuV/m)=Reading(dBuV)+Factor(dB/m)
Factor(dB/m)=Antenna Factor(dB/m)+Cable loss(dB)+Attenuation(dB)for Attenuator
Margin=Level-Limit
Limit(dBuV/m)=20log(2400/F(kHz))+40log(300/3)=105.76dBuV/m.


                             ®
A\GC                                                                                                             Report No.: AGC02724191002FEO3
                                                                                                                                                 Page 14 of 31


                                                          RADIATED EMISSION 30MHz— 1GHz
EUT :                            Wireless charging with clock                           Model Name. :                      XO—9757
Temperature :                    23 C                                                   Relative Humidity:                 58%
Pressure :                       1010 hPa                                               Test Voltage :                     DC 5V
Test Mode         :              Mode 1                                                 Polarization :                     Horizontal
 66.9        dBu¥/m
                                                                                                                                        Limit:        ——
                                                                                                                                        Margin:       ——




                                                                                                                                                    xon
                                                                                                                                   ui
                                                 m




                                                                                                                                      olM
  27                                        1:    |




                                                                  |        3                            %M




13
     30.000      127.00          224.00           321.00       418.00          515.00        612.00          709.00         806. 00               1000.00 MHz




 No. Iyl k        Freq.          Reading|        Factor     |Measurement|       Limit      Over Detector Agteei;fi? DLZELEE                   Comment

         f            M Hz        ddouy           do‘m          dBuyim         ddouyim      dB                        cm      degree

  1             266.0333          10.59          18.80          29.39           46.00 |—16.61|        peak
  4             296.7500          11.80          18.55          31.35           46.00 |—14.65|        peak
  3             4794333            1.86          24 .58         26.44           46.00 |—19.56)|       peak
  4             660.5000           1.78          27 6B          28 .46          46.00 |—16.54|        peak
  §      *      B27.0167          2.01           30.76          42.77           46.00 |—134.23|       peak
  6             962.8167          2.83           32 .24         35.07           54.00 |—18.93|        peak




RESULT: PASS




                                                           Attestation of Global Compliance(Shenzhen)Co.,Ltd.
                                                           Add: 2/F., Building 2,Sanwei Chaxi Industrial Park, Sanwei Community,
                                                                Hangcheng Street, Bao‘an District, Shenzhen, Guangdong, China
                                                           Tel: +86—755 2523 4088        E—mail: agc@age—cert.com         Service Hotline:400 089 2118


AGC                                                                                                  Report No.: AGCO02724191002FEO3
                                                                                                                                Page 15 of 31




EUT :                        Wireless charging with clock                  Model Name. :                    XO—9757
Temperature :                23 C                                          Relative Humidity:               58%
Pressure :                   1010 hPa                                      Test Voltage                     DC 5V
Test Mode                    Mode 1                                        Polarization :                   Vertical

 66.9           dBu¥/m
                                                                                                                           Limat:       ——
                                                                                                                           Margin:      _——




       ]a         |—I                                                                                             ?Wm
                                                                                                                                       §
                              3 4M
                                w

  *                          2WW




13
      30.000        127.00    224.00     321.00        418.00       515.00        612.00          709.00       806.00                100000 MHz


                                  .                                    2222                        Antenna|     Table
 No . Iyl k         Freq.
                        o    Readin d   Factor    |Measurement|      Limit    Cver                     .
                                                                                       Detector      Height    Degree          Comment
                     MHz      dBuy‘      cBim          dBu‘¥im      dBu¥im|     dB                     cm       degree

  1         *      30.0000    16 .87    18.17          35.04        40.00     |—4.96    peak
  2               170.6500    7.24      18.08          25.33        43.50 |—18.17|—     peak
  3               299.9833    8.56      19 47          28.03        46.00 |—17.97|      peak
  4               808.7667    2 .38     27.06          29.47        486.00 |—16.58|     peak
  §               809.2333    2.34      30.53          32.87        46.00 |—13.13)]     peak
  6               9644333     3 .22     32.25          35§.47        §4.00 |—18.53)|       peak




RESULT: PASS
Note:           Factor=Antenna Factor + Cable loss, Margin=Limit—Level.

            The "Factor" value can be calculated automatically by software of measurement system.




                                                  Attestation of Global Compliance(Shenzhen)Co.,Ltd.
                                                  Add: 2/F., Building 2,Sanwei Chaxi Industrial Park, Sanwei Community,
                                                       Hangcheng Street, Bao‘an District, Shenzhen, Guangdong, China
                                                  Tel: +86—755 2523 4088        E—mail: agc@agec—cert.com         Service Hotline:400 089 2118


                                                                      Report No.: AGC02724191002FE03
                                                                                         Page 16 of 31


8. 20DB BANDWIDTH
8.1. MEASUREMENT PROCEDURE
 1. The EUT was placed on the top of the turntable 0.8 meter above ground. The phase center of the
    receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away
    from the turntable.
 2, Set the EUT Work on operation frequency.
 3. Set Span = approximately 2 to 5 times the 20 dB bandwidth, centered on a channel
    The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video
    bandwidth (VBW) shall be approximately three times RBW; Sweep = auto; Detector function = peak
 4. Set SPA Trace 1 Max hold, then View.


8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)


                                                        Report No.: AGC02724191002FE03
                                                                           Page 17 of 31


8.3. MEASUREMENT RESULTS
TEST ITEM                20DB BANDWIDTH

TEST MODULATION          FSK


                        Test Data (Hz)                                 Criteria
             Operate Channel                     249                    PASS


                               TEST PLOT OF BANDWIDTH


                                                                             Report No.: AGC02724191002FE03
                                                                                                Page 18 of 31


9. FCC LINE CONDUCTED EMISSION TEST
9.1. LIMITS OF LINE CONDUCTED EMISSION TEST

                                                               Maximum RF Line Voltage
             Frequency
                                                    Q.P.( dBuV)                        Average( dBuV)
          150kHz~500kHz                                66-56                                 56-46
           500kHz~5MHz                                   56                                    46
           5MHz~30MHz                                    60                                    50
Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50MHz.


9.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST



                  EUT & Support
                  Units


                                                                          Report No.: AGC02724191002FE03
                                                                                             Page 19 of 31


9.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST
1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
   manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
   placed on the ground plane as per ANSI C63.10 (see Test Facility for the dimensions of the ground plane
   used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
   mm non-conductive covering to insulate the EUT from the ground plane.
2. Support equipment, if needed, was placed as per ANSI C63.10.
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
4. All support equipments received AC120V/60Hz power from a LISN, if any.
5. The EUT received charging voltage by adapter which received 120V/60Hzpower by a LISN..
6. The test program was started. Emissions were measured on each current carrying line of the EUT using a
   spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring
   points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to
   Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a
   50 ohm load and Line 2 connected to the Analyzer / Receiver.
7. Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.
9. The test mode(s) were scanned during the preliminary test.

Then, the EUT configuration and cable configuration of the above highest emission level were recorded for
reference of final testing.


9.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST
1.   EUT and support equipment was set up on the test bench as per step 2 of the preliminary test.
2.    A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
     Emission frequency and amplitude were recorded into a computer in which correction factors were used
     to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
     less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
     detector.
3.    The test data of the worst case condition(s) was reported on the Summary Data page.


                                                        Report No.: AGC02724191002FE03
                                                                           Page 20 of 31


9.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST
                           LINE CONDUCTED EMISSION TEST-L




RESULT: PASS


                                            Report No.: AGC02724191002FE03
                                                               Page 21 of 31


               LINE CONDUCTED EMISSION TEST-N




RESULT: PASS


                                    Report No.: AGC02724191002FE03
                                                       Page 22 of 31


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
FCC RADIATED EMISSION TEST SETUP BELOW 1GHZ


                                 Report No.: AGC02724191002FE03
                                                    Page 23 of 31


FCC LINE CONDUCTED EMISSION TEST SETUP


                           Report No.: AGC02724191002FE03
                                              Page 24 of 31


APPENDIX B: PHOTOGRAPHS OF EUT
        ALL VIEW OF EUT




        TOP VIEW OF EUT


                     Report No.: AGC02724191002FE03
                                        Page 25 of 31


BOTTOM VIEW OF EUT




FRONT VIEW OF EUT


                   Report No.: AGC02724191002FE03
                                      Page 26 of 31


BACK VIEW OF EUT




LEFT VIEW OF EUT


                     Report No.: AGC02724191002FE03
                                        Page 27 of 31


RIGHT VIEW OF EUT




OPEN VIEW OF EUT-1


                     Report No.: AGC02724191002FE03
                                        Page 28 of 31


OPEN VIEW OF EUT-2




OPEN VIEW OF EUT-3


                         Report No.: AGC02724191002FE03
                                            Page 29 of 31


 OPEN VIEW OF EUT-4




INTERNAL VIEW-1 OF EUT




      Antenna


                         Report No.: AGC02724191002FE03
                                            Page 30 of 31


INTERNAL VIEW-2 OF EUT




INTERNAL VIEW-3 OF EUT


                         Report No.: AGC02724191002FE03
                                            Page 31 of 31


INTERNAL VIEW-4 OF EUT




----END OF REPORT----