14_XO-9757 TestRpt

FCC ID: 2ADK3-XO-9757

Test Report

Download: PDF
FCCID_4499142

                                                                                      Page 1 of 13




              RF Exposure Report

                         Report No.: AGC02724191002FH03




 FCC ID                         : 2ADK3-XO-9757

 APPLICATION PURPOSE            : Original Equipment

 PRODUCT DESIGNATION            : Wireless charging with clock

 BRAND NAME                     : N/A

 MODEL NAME                     : XO-9757

 APPLICANT                      : XING DA INTERNATIONAL ELECTRONICS LIMITED

 DATE OF ISSUE                  : Oct. 28, 2019
                                    KDB 680106 D01 RF Exposure Wireless Charging Base
 STANDARD(S)                    :
                                    App v03
 REPORT VERSION                 : V1.0




      Attestation of Global Compliance (Shenzhen) Co., Ltd

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.


                                                               Report No.: AGC02724191002FH03
                                                                                   Page 2 of 13


                               REPORT REVISE RECORD

Report Version   Revise Time   Issued Date     Valid Version                  Notes

    V1.0              /        Oct. 28, 2019       Valid                  Initial Release


                                                                                                             Report No.: AGC02724191002FH03
                                                                                                                                 Page 3 of 13



                                                            TABLE OF CONTENTS

1. VERIFICATION OF CONFORMITY .........................................................................................4

2. GENERAL INFORMATION......................................................................................................5

   2.1. PRODUCT DESCRIPTION ....................................................................................................................5

3. DESCRIPTION OF TEST MODES ..........................................................................................6

4. SYSTEM TEST CONFIGURATION .........................................................................................6

5. TEST FACILITY .......................................................................................................................7

6. RADIO FREQUENCY (RF) EXPOSURE TEST .......................................................................8

   6.1. LIMITS...................................................................................................................................................8
   6.2. TEST SETUP.........................................................................................................................................8

APPENDIX A: PHOTOGRAPHS OF TEST SETUP................................................................... 11


                                                                          Report No.: AGC02724191002FH03
                                                                                              Page 4 of 13


  1. VERIFICATION OF CONFORMITY
Applicant                  XING DA INTERNATIONAL ELECTRONICS LIMITED

Address                    #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong, China

Manufacturer               XING DA INTERNATIONAL ELECTRONICS LIMITED

Address                    #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong, China

Factory                    XING DA INTERNATIONAL ELECTRONICS LIMITED

Address                    #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong, China

Product Designation        Wireless charging with clock

Brand Name                 N/A

Test Model:                XO-9757

Date of test               Oct. 15, 2019 to Oct. 28, 2019

Deviation                  None

Condition of Test Sample Normal

Report Template            AGCRT-US-BR/RF

  We hereby certify that:
  The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data, data
  evaluation, test procedures, and equipment configurations shown in this report were made in accordance with
  the procedures given in KDB 680106 D01.
  The results of testing in this report apply to the product/system which was tested only.


                      Prepared By

                                                Jeast Zhan
                                                                           Oct. 28, 2019
                                             (Project Engineer)

                      Reviewed By

                                                 Max Zhang
                                                                           Oct. 28, 2019
                                                 (Reviewer)

                      Approved By

                                                 Forrest Lei
                                                                           Oct. 28, 2019
                                            ( Authorized Officer )


                                                                        Report No.: AGC02724191002FH03
                                                                                            Page 5 of 13


2. GENERAL INFORMATION
2.1. PRODUCT DESCRIPTION
A major technical description of EUT is described as following
Operation Frequency                          123.6kHz
Maximum field strength                       55.65dBuV/m(PK)@3m
Number of channels                           1
Antenna Designation                          Integrated Antenna (Met 15.203 Antenna requirement)
Hardware Version                             XO9757-1 V0
Software Version                             V1.0
Power Supply                                 DC 5V 2A by adapter


                                                                         Report No.: AGC02724191002FH03
                                                                                             Page 6 of 13


3. DESCRIPTION OF TEST MODES
NO.                                         TEST MODE DESCRIPTION
 1                                       Wireless charging Mode(Full load)
 2                                       Wireless charging Mode(half load)
 3                                      Wireless charging Mode(Null load)
Note:
1. The mode 1 was the worst case and only the data of the worst case record in this report.
2. Both adaptors are tested and reported the worst-case data.


4. SYSTEM TEST CONFIGURATION
 Item        Equipment            Model No.              ID or Specification                  Remark

        portfolio with wireless
  1                                 0911-07                2ADK3-XO-9757                        EUT
                charge


  2             Load                  N/A                        5W                           Accessory


  3            Adapter                N/A                     DC 5V 2A                        Accessory


  4          USB Cable                N/A                 1.0m, Unshielded                    Accessory


                                                                      Report No.: AGC02724191002FH03
                                                                                          Page 7 of 13


5. TEST FACILITY
     Test Site        Attestation of Global Compliance (Shenzhen) Co., Ltd
                      1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping Community,
     Location
                      Fuhai Street, Bao'an District, Shenzhen, Guangdong, China
Designation Number    CN1259
  FCC Test Firm
                      975832
Registration Number
  A2LA Cert. No.      5054.02
    Description       Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by A2LA

TEST EQUIPMENT LIST
    Description        Manufacturer           Model           S/N             Cal. Date      Cal. Due
  Broadband Field     Narda Safety Test
                                            NBM-550          J-0004          Jun.12, 2019   Jun.11, 2020
       Meter          Solutions GmbH
                      Narda Safety Test
    Probe FHP                               EHP-50F          J-0015          Jun.12, 2019   Jun.11, 2020
                      Solutions GmbH


                                                                             Report No.: AGC02724191002FH03
                                                                                                 Page 8 of 13


6. RADIO FREQUENCY (RF) EXPOSURE TEST
6.1. LIMITS
For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation
should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or
numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides
and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the
device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of
Section 1.1310: 614 V/m and 1.63 A/m.


6.2. TEST SETUP




Note: Position A: Front of EUT; Position B: Left of EUT; Position C: back of EUT; Position D: Right of EUT;
Position E: Top of EUT(20 cm measure distance);


                                                                              Report No.: AGC02724191002FH03
                                                                                                  Page 9 of 13


6.3. TEST PROCEDURE
The EUT was placed on a non-conductive table top and the ancillary equipment (e.g. mobile phone) was
placed on the EUT for charging.
Maximum E-field and H-field measurements were tested 15cm from each side of the EUT. For top side the
measure distance is 20cm.
Along the side of the EUT to center of E-field probe and H-field probe were positioned at the location to search
maximum field strength.


6.4. TEST RESULT
Test condition: Mode 1
E-field strength test result:

                       Probe          Probe           Probe            Probe             Probe
Frequency                                                                                                Limit
                       Position A     Position B      Position C       Position D        Position E
Range                                                                                                    (V/m)
                       (V/m)          (V/m)           (V/m)            (V/m)             (V/m)
123.6kHz               0.16           0.16            0.16             0.16              2.45            614


H-field strength test result:

                       Probe          Probe           Probe            Probe             Probe
Frequency                                                                                                Limit
                       Position A     Position B      Position C       Position D        Position E
Range                                                                                                    (A/m)
                       (A/m)          (A/m)           (A/m)            (A/m)             (A/m)
123.6kHz               0.08           0.08            0.08             0.08              0.52            1.63


Test condition: Mode 2
E-field strength test result:

Frequency              Probe          Probe           Probe            Probe             Probe           Limit
Range                  Position A     Position B      Position C       Position D        Position E      (V/m)
                       (V/m)          (V/m)           (V/m)            (V/m)             (V/m)
164.3kHz               0.16           0.16            0.16             0.16              1.69            614


H-field strength test result:

Frequency              Probe          Probe           Probe            Probe             Probe           Limit
Range                  Position A     Position B      Position C       Position D        Position E      (A/m)
                       (A/m)          (A/m)           (A/m)            (A/m)             (A/m)
164.3kHz               0.08           0.08            0.08             0.08              0.29            1.63


                                                                     Report No.: AGC02724191002FH03
                                                                                        Page 10 of 13


Test condition: Mode 3
E-field strength test result:

Frequency              Probe        Probe        Probe        Probe             Probe          Limit
Range                  Position A   Position B   Position C   Position D        Position E     (V/m)
                       (V/m)        (V/m)        (V/m)        (V/m)             (V/m)
203.0kHz               0.16         0.16         0.16         0.16              1.42           614


H-field strength test result:

Frequency              Probe        Probe        Probe        Probe             Probe          Limit
Range                  Position A   Position B   Position C   Position D        Position E     (A/m)
                       (A/m)        (A/m)        (A/m)        (A/m)             (A/m)
203.0kHz               0.13         0.13         0.13         0.13              0.33           1.63


                              Report No.: AGC02724191002FH03
                                                 Page 11 of 13


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
               Position E




               Position A


             Report No.: AGC02724191002FH03
                                Page 12 of 13


Position B




Position C


                        Report No.: AGC02724191002FH03
                                           Page 13 of 13


      Position D




----END OF REPORT----



Document Created: 2019-11-04 16:27:40
Document Modified: 2019-11-04 16:27:40

© 2025 FCC.report