Test Report

FCC ID: 2ADJKJMA-610

Test Report

Download: PDF
FCCID_2719138

                                            849 NW STATE ROAD 45
                                            NEWBERRY, FL 32669 USA
                                            PH: 888.472.2424 OR
                                            352.472.5500
                                            FAX: 352.472.2030
                                            EMAIL: INFO@TIMCOENGR.COM
                                            HTTP://WWW.TIMCOENGR.COM




                          FCC PART 80
           CLASS II PERMISSIVE CHANGE
                   RADAR TEST REPORT
             APPLICANT             ALPHATRON MARINE USA, INC.
                                       1205 BUTLER ROAD
                                   LEAGUE CITY TX 77573 USA
                 FCC ID                   2ADJKJMA-610
         MODEL NUMBER                        JMA-610
  PRODUCT DESCRIPTION                     MARINE RADAR
  DATE SAMPLE RECEIVED                      7/21/2015
           DATE TESTED                      8/10/2015
             TESTED BY                     Sid Sanders
           APPROVED BY                    Cory Leverett
          TEST RESULTS                     PASS           FAIL



Report                   Version          Description            Issue Date
Number                   Number
1461AUT15TestReport.docx Rev.1            Initial Issue          8/14/2015


 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL
  WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC.


                                     TABLE OF CONTENTS

GENERAL REMARKS ...................................................................................... 3

EUT SPECIFICATION ..................................................................................... 4

TEST SETUP INFORMATION ............................................................................ 4

TEST REPORT SUMMARY ................................................................................ 5

SPURIOUS EMISSIONS AT ANTENNA TERMINALS (CONDUCTED) ......................... 6

EQUIPMENT LIST .......................................................................................... 8




Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKJMA-610
Report:    a\Alphatron\1461AUT15\1461AUT15TestReport.docx
                                                                                              Page 2 of 8


GENERAL REMARKS

The attached report shall not be reproduced except in full without the written
permission of Timco Engineering Inc.

The test results relate only to the items tested.

Summary

The device under test does:
   Fulfill the general approval requirements as identified in this test report
   Not fulfill the general approval requirements as identified in this test report

Attestations

This equipment has been tested in accordance with the standards identified in this
test report. To the best of my knowledge and belief, these tests were performed
using the measurement procedures described in this report.

All instrumentation and accessories used to test products for compliance to the
indicated standards are calibrated regularly in accordance with ISO 17025:2005
requirements.


I attest that the necessary measurements were made, under my supervision, at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, FL 32669

Authorized Signatory Name:




Sid Sanders
Engineering Project Manager

Date: 14 August 2015

TABLE OF CONTENTS




Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKJMA-610
Report:    a\Alphatron\1461AUT15\1461AUT15TestReport.docx
                                                                            Page 3 of 8


EUT SPECIFICATION

          EUT Description     MARINE RADARMARINE RADAR
                   FCC ID     2ADJKJMA-610
           Model Number       JMA-610
           Serial Number      N/A
     Operating Frequency      9400 MHz
          No. of Channels     1
         Type of Emission     9300-9500 MHz
              Modulation      P0N
                                  110–120Vac/50– 60Hz
        EUT Power Source          DC Power (24 VDC)
                                  Battery Operated Exclusively
                                  Prototype
                Test Item         Pre-Production
                                  Production
                                  Fixed
       Type of Equipment          Mobile
                                  Portable


TEST SETUP INFORMATION

                              Timco Engineering, Inc. 849 NW State Road 45,
              Test facility
                              Newberry, FL 32669
                              The EUT was tested under normal temperature and
           Test Condition     humidity. The temperature was 26ºC with a relative
                              humidity of 50%.
            Modifications     Tested with Magnetron MAF1562R
            Test Exercise     The EUT was operated in a normal mode.
     Applicable Standards     ANSI/TIA 603-C;2004 , FCC CFR 47 Part 80/90


TABLE OF CONTENTS




Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKJMA-610
Report:    a\Alphatron\1461AUT15\1461AUT15TestReport.docx
                                                                               Page 4 of 8


TEST REPORT SUMMARY



    Rule Part No.                  Scope of Work               Status
                                                            Pass/Fail/NA
2.1051(a)                  Antenna Conducted Emissions          Pass


Table of Contents




Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKJMA-610
Report:    a\Alphatron\1461AUT15\1461AUT15TestReport.docx
                                                                 Page 5 of 8


SPURIOUS EMISSIONS AT ANTENNA TERMINALS (CONDUCTED)

Rule Part No.:      Part 2.1051(a) & 80.217

Requirements:       43+10log (mean power)
                    43 + 10log (5.7) = 50.55 dB

Method of Measurement:             The spectrum was scanned from 0.4 to at least
the 10th harmonic of the fundamental or 40 GHz. The measurements were made
in accordance with standard ANSI/TIA 603 or ANSI 63.4:2009.

The mean power was calculated based on the standard formula for radar systems:
Pa= Pm* Td * fr. Where Td is pulse duration, Pm is peak power, and fr is pulse rep
rate.

                     transmitter     attenuator      Spectrum
                     under test                      Analyzer




Test Data: Worst case: single pulse mode setting Range 32 (longest pulse)


                                                    dBm       Watts    Margin
                                   Power Output   Frequency     5.7
                                      LIMIT         MHz       43dBc
                                                                dBc     dB
                                                    9400         0
                                                   18300      69.04    18.49
                                                   28200      101.20   50.65
                                                   37600      97.37    46.82
                                                   47000      132.96   82.41
                                                   56400      131.06   80.51
                                                   65800      132.77   82.22
                                                   75200      131.04   80.49
                                                   84600      134.76   84.21
                                                   $4000      135.19   84.64



Table of Contents



Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKIMA—610
Report:   a\ Alphatron\1 461 AUT15\1461AUT15TestReport.docx
                                                                                Page 6 of 8


SPURIOUS EMISSIONS AT ANTENNA TERMINALS

Test Data: Worst case: Range 16


                                                  dBm       Watts    Margin
                                Power Output   Frequency     5.7
                                   LIMIT          MHz       43dBc
                                                             dBc      dB
                                                  9400        0
                                                 18800      72.85    22.30
                                                 28200      82.03    31.48
                                                 37600      109.23   58.68
                                                 47000      145.91   95.36
                                                 56400      144.01   93.46
                                                 65800      145.72   95.17
                                                 75200      143.99   93.44
                                                 84600      147.71   97.16
                                                 94000      148.14   97.59




Various modes and center frequencies were tested and the worst case presented
above. Harmonics were checked to the 10th harmonic.




TABLE OF CONTENTS




Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKJMA-610
Report:    a\Alphatron\1461AUT15\1461AUT15TestReport.docx
                                                                              Page 7 of 8


EQUIPMENT LIST

       Device              Manufacturer          Model         Serial      Cal/Char   Due Date
                                                              Number         Date
   24 Volt Power               Astron           VLS-25M       9510040      12/12/99   12/12/99
       Supply
   Antenna: Log-                Eaton            96005          1243       05/31/13   11/30/15
 Periodic Chamber
  LISN (Primary)          Electro-Metrics       EM-7820        2682        05/08/15   05/08/17
    Temperature               Tenney             TTRC         11717-7      08/19/14   08/19/16
  Chamber LARGE             Engineering
 DC Power Supply                HP               6286A       2411A09414    12/12/99   12/12/99
Frequency Counter               HP               5352B       2632A00165    07/01/15   07/01/17
  Large Chamber
Frequency Counter                HP              5385A       3242A07460    07/01/15   07/01/17
  Small Chamber
   3-Meter Semi-            Panashield            N/A           N/A        12/31/13   12/31/15
Anechoic Chamber
   Sweep/Signal                Anritsu          68369B         985112      08/29/13   08/29/15
     Generator
    Oscilloscope               LeCroy            LT364         00414       08/22/13   08/22/15
EMI Test Receiver             Rohde &           ESIB 40        100274      08/12/14   08/12/16
   R & S ESIB 40              Schwarz
    Screen Room
  Software: Field              Timco              N/A        Version 4.0   12/12/99   12/12/99
Strength Program
 USB Peak Power               Boonton            55318          9224       11/06/14   11/06/16
 Sensor 50 MHz to
       18 GHz
  RF Power Meter              Boonton             4531         11793       02/17/15   02/17/17
EMI Test Receiver             Rohde &            ESU 40        100320      03/11/14   03/11/16
   R & S ESU 40               Schwarz
      Chamber
   Bi-Directional                HP               778D       1144A08107    05/06/13   05/06/15
      Coupler



*EMI RECEIVER SOFTWARE VERSION

The receiver firmware used was version 4.43 Service Pack 3


TABLE OF CONTENTS




Applicant: ALPHATRON MARINE USA, INC.
FCC ID:    2ADJKJMA-610
Report:    a\Alphatron\1461AUT15\1461AUT15TestReport.docx
                                                                                      Page 8 of 8



Document Created: 2019-11-01 14:25:17
Document Modified: 2019-11-01 14:25:17

© 2024 FCC.report