1903RSU036-U1-FCC-DXX-Test-Report

FCC ID: 2ADI8-SL032

Test Report

Download: PDF
FCCID_4266111

                                       MRT Technology (Suzhou) Co., Ltd          Report No.: 1903RSU036-U1
                                       Phone: +86-512-66308358                   Report Version:        V01
                                       Web:    www.mrt-cert.com                  Issue Date:     04-30-2019




                         MEASUREMENT REPORT
                               FCC PART 15.225 RFID

FCC ID:                       2ADI8-SL032

Applicant:                    BEIJING STRONGLINK TECHNOLOGY CO,. LTD.


Application Type:             Certification

Product:                      MIFARE MODULE

Model No.:                    SL032_V3.1

FCC Classification: Part 15 Low Power Communication Device Transmitter
                              (DXX)
FCC Rule Part(s):             Part 15 Subpart C (Section 15.225)

Test Procedure(s): ANSI C63.10-2013

Test Date:                    April 11 ~ 19, 2019




Reviewed By:
                                  ( Sunny Sun )
Approved By:
                                   (Robin Wu)



The test results relate only to the samples tested.
This equipment has been shown to be capable of compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures specified
in ANSI C63.10. Test results reported herein relate only to the item(s) tested.
The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou)
Co., Ltd.
 FCC ID: 2ADI8-SL032                                                                       Page Number: 1 of 32


                                                      Report No.: 1903RSU036-U1


                                Revision History

   Report No.         Version      Description      Issue Date         Note

1903RSU036-U1         Rev. 01      Initial Report   04-30-2019         Valid




FCC ID: 2ADI8-SL032                                          Page Number: 2 of 32


                                                                                                            Report No.: 1903RSU036-U1


                                                            CONTENTS
Description                                                                                                                                  Page
§2.1033 General Information ............................................................................................................ 5

1.     INTRODUCTION ........................................................................................................................ 6

      1.1.       Scope .............................................................................................................................. 6
      1.2.       MRT Test Location .......................................................................................................... 6

2.     PRODUCT INFORMATION ........................................................................................................ 7

      2.1.       Equipment Description .................................................................................................... 7
      2.2.       Test Mode ....................................................................................................................... 7
      2.3.       Test Configuration ........................................................................................................... 7
      2.4.       EMI Suppression Device(s)/Modifications ....................................................................... 7
      2.5.       Labeling Requirements ................................................................................................... 7

3.     DESCRIPTION OF TEST ........................................................................................................... 8

      3.1.       Evaluation Procedure ...................................................................................................... 8
      3.2.       AC Line Conducted Emissions ........................................................................................ 8
      3.3.       Radiated Emissions......................................................................................................... 9

4.     ANTENNA REQUIREMENTS .................................................................................................. 10

5.     TEST EQUIPMENT CALIBRATION DATE .............................................................................. 11

6.     MEASUREMENT UNCERTAINTY ........................................................................................... 13

7.     TEST RESULT ......................................................................................................................... 14

      7.1.       Summary ....................................................................................................................... 14
      7.2.       In-band Emission........................................................................................................... 15
      7.2.1.        Test Limit ................................................................................................................... 15
      7.2.2.        Test Procedure Used ................................................................................................. 15
      7.2.3.        Test Setting................................................................................................................ 15
      7.2.4.        Test Setup ................................................................................................................. 16
      7.2.5.        Test Result ................................................................................................................. 17
      7.3.       Out-band Emission ........................................................................................................ 18
      7.3.1.        Test Limit ................................................................................................................... 18
      7.3.2.        Test Procedure Used ................................................................................................. 18
      7.3.3.        Test Setting................................................................................................................ 18
      7.3.4.        Test Setup ................................................................................................................. 19
      7.3.5.        Test Result ................................................................................................................. 20
      7.4.       20dB Bandwidth ............................................................................................................ 21
      7.4.1.        Test Limit ................................................................................................................... 21

FCC ID: 2ADI8-SL032                                                                                                    Page Number: 3 of 32


                                                                                                          Report No.: 1903RSU036-U1


      7.4.2.       Test Procedure Used ................................................................................................. 21
      7.4.3.       Test Setting ................................................................................................................ 21
      7.4.4.       Test Setup ................................................................................................................. 21
      7.4.5.       Test Result ................................................................................................................. 22
      7.5.      Frequency Tolerence .................................................................................................... 23
      7.5.1.       Test Limit ................................................................................................................... 23
      7.5.2.       Test Procedure Used ................................................................................................. 23
      7.5.3.       Test Setting ................................................................................................................ 23
      7.5.4.       Test Setup ................................................................................................................. 24
      7.5.5.       Test Result ................................................................................................................. 25
      7.6.      AC Conducted Emissions Measurement....................................................................... 26
      7.6.1.       Test Limit ................................................................................................................... 26
      7.6.2.       Test Setup ................................................................................................................. 26
      7.6.3.       Test Result ................................................................................................................. 27

8.    CONCLUSION.......................................................................................................................... 30

Appendix A - Test Setup Photograph ............................................................................................ 31

Appendix B - EUT Photograph ...................................................................................................... 32




FCC ID: 2ADI8-SL032                                                                                                 Page Number: 4 of 32


                                                                        Report No.: 1903RSU036-U1



§2.1033 General Information
Applicant:                    BEIJING STRONGLINK TECHNOLOGY CO,. LTD.
Applicant Address:            Building C No.39 Xi'erqi street Haidian district, Beijing, 100085
                              China
Manufacturer:                 BEIJING STRONGLINK TECHNOLOGY CO,. LTD.
                              Building C No.39 Xi'erqi street Haidian district, Beijing, 100085
Manufacturer Address:
                              China
Test Site:                    MRT Technology (Suzhou) Co., Ltd
Test Site Address:            D8 Building, No.2 Tian’edang Rd., Wuzhong Economic
                              Development Zone, Suzhou, China


Test Facility / Accreditations
Measurements were performed at MRT Laboratory located in Tian’edang Rd., Suzhou, China.
 MRT facility is a FCC registered (MRT Reg. No. 893164) test facility with the site description
  report on file and has met all the requirements specified in Section 2.948 of the FCC Rules.
 MRT facility is an IC registered (MRT Reg. No. 11384A-1) test laboratory with the site
  description on file at Industry Canada.
 MRT facility is a VCCI registered (R-20025, G-20034,
  C-20020, T-20020) test laboratory with the site
  description on file at VCCI Council.
 MRT Lab is accredited to ISO 17025 by the American
  Association for Laboratory Accreditation (A2LA) under
  the American Association for Laboratory Accreditation
  Program (A2LA Cert. No. 3628.01) in EMC,
  Telecommunications and Radio testing for FCC,
  Industry Canada, EU and TELEC Rules.




FCC ID: 2ADI8-SL032                                                            Page Number: 5 of 32


                                                                          Report No.: 1903RSU036-U1



1.    INTRODUCTION
1.1. Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices
including intentional and/or unintentional radiators for compliance with the technical rules and
regulations of the Federal Communications Commission and the Industry Canada Certification and
Engineering Bureau.



1.2. MRT Test Location
The map below shows the location of the MRT LABORATORY, its proximity to the Taihu Lake.
These measurement tests were conducted at the MRT Technology (Suzhou) Co., Ltd. Facility
located at D8 Building, No.2 Tian’edang Rd., Wuzhong Economic Development Zone, Suzhou,
China. The measurement facility compliant with the test site requirements specified in ANSI
C63.4-2014.




FCC ID: 2ADI8-SL032                                                              Page Number: 6 of 32


                                                                         Report No.: 1903RSU036-U1



2.       PRODUCT INFORMATION
2.1. Equipment Description
Product Name:                 MIFARE MODULE
Model No.:                    SL032_V3.1
RF ID:                        13.56MHz



2.2. Test Mode
Test Mode
Mode 1: Transmit by RFID



2.3. Test Configuration
The device was set to continuous transmission. This was performance using manufacturer software
loaded on the MIFARE MODULE to allow for continuous transmission. This device was tested in
accordance with the guidance of ANSI C63.10-2013. ANSI C63.10-2013 was used to reference the
appropriate EUT setup for radiated spurious emissions testing and AC line conducted testing.



2.4. EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and/or no modifications were made during testing.



2.5. Labeling Requirements
Per 2.1074 & 15.19; Docket 95-19
The label shall be permanently affixed at a conspicuous location on the device; instruction manual or
pamphlet supplied to the user and be readily visible to the purchaser at the time of purchase.
However, when the device is so small wherein placement of the label with specified statement is not
practical, only the FCC ID must be displayed on the device per Section 15.19(a)(5). Please see
attachment for FCC ID label and label location.




FCC ID: 2ADI8-SL032                                                             Page Number: 7 of 32


                                                                           Report No.: 1903RSU036-U1



3.      DESCRIPTION OF TEST
3.1. Evaluation Procedure
The measurement procedures described in the American National Standard for Testing Unlicensed
Wireless Devices (ANSI C63.10-2013) was used in the measurement.
Deviation from measurement procedure…………………………….....................................None



3.2. AC Line Conducted Emissions
The line-conducted facility is located inside an 8'x4'x4' shielded enclosure. A 1m x 2m wooden table
80cm high is placed 40cm away from the vertical wall and 80cm away from the sidewall of the
shielded room. Two 10kHz-30MHz, 50Ω/50uH Line-Impedance Stabilization Networks (LISNs) are
bonded to the shielded room floor. Power to the LISNs is filtered by external high-current
high-insertion loss power line filters. These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.
The EUT is powered from one LISN and the support equipment is powered from the second LISN.
All interconnecting cables more than 1 meter were shortened to a 1 meter length by non-inductive
bundling (serpentine fashion) and draped over the back edge of the test table. All cables were at
least 40cm above the horizontal reference ground-plane. Power cables for support equipment were
routed down to the second LISN while ensuring that that cables were not draped over the second
LISN.
Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to
warm up to their normal operating condition. The RF output of the LISN was connected to the
receiver and exploratory measurements were made to determine the frequencies producing the
maximum emission from the EUT. The receiver was scanned from 150kHz to 30MHz. The detector
function was set to peak mode for exploratory measurements while the bandwidth of the analyzer
was set to 9kHz. The EUT, support equipment, and interconnecting cables were arranged and
manipulated to maximize each emission. Each emission was also maximized by varying: power lines,
the mode of operation or data exchange speed, or support equipment whichever determined the
worst-case emission. Once the worst case emissions have been identified, the one EUT cable
configuration/arrangement and mode of operation that produced these emissions are used for final
measurements on the same test site. The analyzer is set to CISPR quasi-peak and average
detectors with a 9kHz resolution bandwidth for final measurements.
An extension cord was used to connect to a single LISN which powered by EUT. The extension cord
was calibrated with LISN, the impedance and insertion loss are compliance with the requirements as
stated in ANSI C63.10-2013.




FCC ID: 2ADI8-SL032                                                               Page Number: 8 of 32


                                                                            Report No.: 1903RSU036-U1



3.3. Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final
measurements and exploratory measurements, when necessary. The measurement area is
contained within the semi-anechoic chamber which is shielded from any ambient interference. For
measurements above 1GHz absorbers are arranged on the floor between the turn table and the
antenna mast in such a way so as to maximize the reduction of reflections. For measurements below
1GHz, the absorbers are removed. A MF Model 210SS turntable is used for radiated measurement.
It is a continuously rotatable, remote controlled, metallic turntable and 2 meters (6.56 ft.) in diameter.
The turn table is flush with the raised floor of the chamber in order to maintain its function as a
ground plane. An 80cm high PVC support structure is placed on top of the turntable.
For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter
receive antenna height using a broadband antenna from 30MHz up to the upper frequency shown in
15.33(b)(1) depending on the highest frequency generated or used in the device or on which the
device operates or tunes. For frequencies above 1GHz, linearly polarized double ridge horn
antennas were used. For frequencies below 30MHz, a calibrated loop antenna was used. When
exploratory measurements were necessary, they were performed at 1 meter test distance inside the
semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers
to determine the frequencies and modes producing the maximum emissions. Sufficient time for the
EUT, support equipment, and test equipment was allowed in order for them to warm up to their
normal operating condition. The test set-up was placed on top of the 0.8 meter high, 1 x 1.5 meter
table. The EUT, support equipment, and interconnecting cables were arranged and manipulated to
maximize each emission. Appropriate precaution was taken to ensure that all emissions from the
EUT were maximized and investigated. The system configuration, clock speed, mode of operation or
video resolution, if applicable, turntable azimuth, and receive antenna height was noted for each
frequency found.
Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized
broadband and horn antennas. The test setup was configured to the setup that produced the worst
case emissions. The spectrum analyzer was set to investigate all frequencies required for testing to
compare the highest radiated disturbances with respect to the specified limits. The turntable
containing the EUT was rotated through 360 degrees and the height of the receive antenna was
varied 1 to 4 meters and stopped at the azimuth and height producing the maximum emission. Each
emission was maximized by changing the orientation of the EUT through three orthogonal planes
and changing the polarity of the receive antenna, whichever produced the worst-case emissions.
According to 3dB Beam-Width of horn antenna, the horn antenna should be always directed to the
EUT when rising height.




FCC ID: 2ADI8-SL032                                                                 Page Number: 9 of 32


                                                                        Report No.: 1903RSU036-U1



4.    ANTENNA REQUIREMENTS
Excerpt from §15.203 of the FCC Rules/Regulations:
“An intentional radiator antenna shall be designed to ensure that no antenna other than that
furnished by the responsible party can be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section.”


    The antenna of the MIFARE MODULE is permanently attached.
    There are no provisions for connection to an external antenna.


Conclusion:
The unit complies with the requirement of §15.203.




FCC ID: 2ADI8-SL032                                                             Page Number: 10 of 32


                                                                      Report No.: 1903RSU036-U1



5.     TEST EQUIPMENT CALIBRATION DATE
Conducted Emissions - SR2

Instrument                  Manufacturer   Type No.     Asset No.     Cali. Interval Cali. Due Date
                                                                      1 year         2019/04/20
EMI Test Receiver           R&S            ESR3         MRTSUE06185
                                                                      1 year         2020/04/15
Two-Line V-Network          R&S            ENV 216      MRTSUE06002 1 year           2019/06/14
Two-Line V-Network          R&S            ENV 216      MRTSUE06003 1 year           2019/06/14
Thermohygrometer            Testo          608-H1       MRTSUE06404 1 year           2019/08/14
Shielding Chamber           MIX-BEP        Chamber-SR2 MRTSUE06214 N/A               N/A

Radiated Emissions - AC1

Instrument                  Manufacturer   Type No.     Asset No.     Cali. Interval Cali. Due Date
EMI Test Receiver           R&S            ESR7         MRTSUE06001 1 year           2019/08/13
PXA Signal Analyzer         Keysight       9030B        MRTSUE06395 1 year           2019/09/25
Loop Antenna                Schwarzbeck    FMZB 1519    MRTSUE06025 1 year           2019/11/09
Bilog Period Antenna        Schwarzbeck    VULB 9168    MRTSUE06172 1 year           2020/03/31
Broad Band Horn Antenna     Schwarzbeck    BBHA 9120D   MRTSUE06023 1 year           2019/10/19
Broad Band Horn Antenna     Schwarzbeck    BBHA 9170    MRTSUE06024 1 year           2019/12/17
Microwave System Amplifier Agilent         83017A       MRTSUE06076 1 year           2019/11/16
Preamplifier                Schwarzbeck    BBV 9721     MRTSUE06121 1 year           2019/06/12
Thermohygrometer            Testo          608-H1       MRTSUE06403 1 year           2019/08/14
Anechoic Chamber            TDK            Chamber-AC1 MRTSUE06213 1 year            2019/05/01


Radiated Emission - AC2

Instrument                  Manufacturer   Type No.     Asset No.     Cali. Interval Cali. Due Date
Spectrum Analyzer           Keysight       N9038A       MRTSUE06125 1 year           2019/08/13
Loop Antenna                Schwarzbeck    FMZB 1519    MRTSUE06025 1 year           2019/11/09
Bilog Period Antenna        Schwarzbeck    VULB 9162    MRTSUE06022 1 year           2019/10/19
Horn Antenna                Schwarzbeck    BBHA9120D    MRTSUE06171 1 year           2019/11/09
Broad Band Horn Antenna     Schwarzbeck    BBHA 9170    MRTSUE06024 1 year           2019/12/17
Broadband Coaxial
                            Schwarzbeck    BBV 9718     MRTSUE06176 1 year           2019/11/16
Preamplifier
Preamplifier                Schwarzbeck    BBV 9721     MRTSUE06121 1 year           2019/06/12
Temperature/Humidity Meter Minggao         ETH529       MRTSUE06170 1 year           2019/12/13
Anechoic Chamber            RIKEN          Chamber-AC2 MRTSUE06213 1 year            2019/05/01




FCC ID: 2ADI8-SL032                                                            Page Number: 11 of 32


                                                                          Report No.: 1903RSU036-U1


Frequency Tolerance - TR3

Instrument                  Manufacturer      Type No.    Asset No.        Cali. Interval Cali. Due Date
EXA Signal Analyzer         Keysight          N9010B      MRTSUE06452 1 year              2019/07/19
Temperature & Humidity
                            BAOYT             BYH-150CL   MRTSUE06051 1 year              2019/11/16
Chamber
Thermohygrometer            testo             608-H1      MRTSUE06401 1 year              2019/08/14


Software                            Version                           Function
EMI Software                        V3                                EMI Test Software




FCC ID: 2ADI8-SL032                                                              Page Number: 12 of 32


                                                                        Report No.: 1903RSU036-U1



6.    MEASUREMENT UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed
at approximately the 95% confidence level using a coverage factor of k = 2.


AC Conducted Emission Measurement - SR2
     The maximum measurement uncertainty is evaluated as:
     9kHz~150kHz: 3.84dB
     150kHz~30MHz: 3.46dB
Radiated Emission Measurement - AC1
     The maximum measurement uncertainty is evaluated as:
     Horizontal: 30MHz~300MHz: 4.07dB
                 300MHz~1GHz: 3.63dB
                 1GHz~18GHz: 4.16dB
     Vertical:   30MHz~300MHz: 4.18dB
                 300MHz~1GHz: 3.60dB
                 1GHz~18GHz: 4.76dB
Radiated Emission Measurement - AC2
     The maximum measurement uncertainty is evaluated as:
     Horizontal: 30MHz~300MHz: 3.75dB
                 300MHz~1GHz: 3.53dB
                 1GHz~18GHz: 4.28dB
     Vertical:   30MHz~300MHz: 3.86dB
                 300MHz~1GHz: 3.53dB
                 1GHz~18GHz: 4.33dB




FCC ID: 2ADI8-SL032                                                            Page Number: 13 of 32


                                                                                 Report No.: 1903RSU036-U1



7.     TEST RESULT
7.1. Summary

  FCC Part       Test Description               Test Limit                Test         Test       Reference
  Section(s)                                                           Condition      Result
                                     For 13.553 ~ 13.567 MHz:
                                     15.848uV/m @ 30m
                                     For 13.410 ~ 13.553 MHz &
15.225(a),                           13.567 ~ 13.710 MHz:
                In-Band Emission                                                       Pass      Section 7.2
(b), (c)                             334uV/m @ 30m
                                     For 13.110 ~ 13.410 MHz &
                                     13.710 ~ 14.010 MHz:
                                     106uV/m @ 30m
                                                                       Radiated
                                     Emissions outside of the
                                     13.110~14.010 MHz band
                Out-Band
15.225(d)                            shall not exceed the general                      Pass      Section 7.3
                Emission
                                     radiated emission limits in
                                     §15.209.
2.1049          20dB Bandwidth       N/A                                               Pass      Section 7.4
                Frequency            ±0.01% of operating
15.225(e)                                                                              Pass      Section 7.5
                Tolerance            frequency
                AC Conducted
                                                                          Line
15.207          Emissions            < §15.207 limits                                  Pass      Section 7.6
                                                                      Conducted
                150kHz - 30MHz
Notes: All modes of operation and data rates were investigated. For radiated emission test, every axis (X, Y, Z)
was also verified. The test results shown in the following sections represent the worst case emissions.




FCC ID: 2ADI8-SL032                                                                     Page Number: 14 of 32


                                                                       Report No.: 1903RSU036-U1



7.2. In-band Emission

7.2.1.Test Limit

                             FCC Part 15 Subpart C Paragraph 15.225
           Frequency                           Distance                         Level
             (MHz)                                  (m)                         (uV/m)
        13.553 ~13.567                              30                          15,848
        13.410 ~13.553
                                                    30                          334.5
        13.567 ~13.710
        13.110 ~13.410
                                                    30                           106
        13.710 ~14.010
Note 1: The lower limit shall apply at the transition frequency.
Note 2: Distance refers to the distance in meters between the measuring instrument antenna and the
closed point of any part of the device or system.
Note 3: E field strength (dBuV/m) = 20 log E field strength (uV/m)

7.2.2.Test Procedure Used

ANSI C63.10 Section 6.3 (General Requirements)

ANSI C63.10 Section 6.4 (Standard test method below 30MHz)

7.2.3.Test Setting

1. Analyzer center frequency was set to the frequency of the radiated spurious emission of interest

2. Set the spectrum analyzer frequency span to capture fully the emission that is to be measured.

3. RBW = 9kHz

4. Detector = CISPR quasi-peak

5. Sweep time = auto couple

6. Trace was allowed to stabilize




FCC ID: 2ADI8-SL032                                                           Page Number: 15 of 32


   EUT



(Turntable)


              Test Receiver


                                                                         Report No.: 1903RSU036-U1



7.2.5.Test Result

Product                  MIFARE MODULE                   Temperature          25°C
Test Engineer            Flag Yang                       Relative Humidity    52%
Test Site                AC1                             Test Time            2019/04/11


Frequency    Reading Level      Factor   Measure Level      Limit (3m)       Margin        Detector
                (dBuV/m)         (dB)       (dBuV/m)        (dBuV/m)          [dB]
 Face On
   13.34         20.30          19.85         40.15              80.51       -40.36          QP
   13.42         28.39          19.86         48.25              90.47       -42.22          QP
   13.56         47.28          19.87         67.15          124.00          -56.85          QP
   13.63         27.92          19.86         47.78              90.47       -42.69          QP
   13.72         23.20          19.87         43.07              80.51       -37.44          QP
 Face Off
   13.34         24.43          19.85         44.28              80.51       -36.23          QP
   13.42         24.09          19.86         43.95              90.47       -46.52          QP
   13.56         44.13          19.87         64.00          124.00          -60.00          QP
   13.63         21.11          19.86         40.97              90.47       -49.50          QP
   13.72         17.89          19.87         37.76              80.51       -42.75          QP
Note:
1. All measurements were performed using a loop antenna. The antenna was positioned in two
    orthogonal (face on and face off) and the position with the highest emission level was recorded.
2. For below 30MHz, the limits were calculated as below:
    E field strength (dBuV/m) = 20 log E field strength (uV/m)
    Limit (dBuV/m)@3m = Limit (dBuV/m)@30m + 40*Log10 (30/3).
    For example, the limits of frequency range (13.553 ~ 13.567MHz) are calculated as below:
    Limit (dBuV/m)@3m = [20*log(15,848) + 40*Log10(30/3)] (dBuV/m) ≈ 124.00 (dBuV/m).
3. Measure Level (dBuV/m) = Reading Level (dBuV) + Factor (dB)
    Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: 2ADI8-SL032                                                             Page Number: 17 of 32


                                                                       Report No.: 1903RSU036-U1



7.3. Out-band Emission

7.3.1.Test Limit

                             FCC Part 15 Subpart C Paragraph 15.209
       Frequency [MHz]                   Field Strength [uV/m]       Measured Distance [Meters]
         0.009 ~ 0.490                       2400/F (kHz)                        300
         0.490 ~ 1.705                      24000/F (kHz)                         30
           1.705 ~ 30                               30                            30
            30 ~ 88                                 100                           3
            88 ~ 216                                150                           3
           216 ~ 960                                200                           3
           Above 960                                500                           3
Note 1: The lower limit shall apply at the transition frequency.
Note 2: Distance refers to the distance in meters between the measuring instrument antenna and the
closed point of any part of the device or system.
Note 3: E field strength (dBuV/m) = 20 log E field strength (uV/m)

7.3.2.Test Procedure Used

ANSI C63.10 Section 6.3 (General Requirements)

ANSI C63.10 Section 6.4 (Standard test method below 30MHz)

ANSI C63.10 Section 6.5 (Standard test method above 30MHz to 1GHz)

7.3.3.Test Setting

1. Analyzer center frequency was set to the frequency of the radiated spurious emission of interest

2. Set the spectrum analyzer frequency span to capture fully the emission that is to be measured.

3. RBW = as specified in Table 1

4. Detector = CISPR quasi-peak or average

5. Sweep time = auto couple

6. Trace was allowed to stabilize




FCC ID: 2ADI8-SL032                                                           Page Number: 18 of 32


                                                                     Report No.: 1903RSU036-U1



                               Table 1 - RBW as a function of frequency

                   Frequency                                          RBW
                   9 ~ 150 kHz                                    200 ~ 300 Hz
                0.15 ~ 30 MHz                                      9 ~ 10 kHz
                30 ~ 1000 MHz                                     100 ~ 120 kHz

7.3.4.Test Setup
9kHz ~ 30MHz Test Setup:




30MHz ~ 1GHz Test Setup:




FCC ID: 2ADI8-SL032                                                         Page Number: 19 of 32


                                                                            Report No.: 1903RSU036-U1



7.3.5.Test Result

Product                  MIFARE MODULE                  Temperature            25°C
Test Engineer            Flag Yang                      Relative Humidity      52%
Test Site                AC1                            Test Time              2019/04/11


Frequency     Reading          Factor   Measure       Limit         Margin      Detector    Polarization
  (MHz)         Level          (dB)      Level      (dBuV/m)         (dB)
              (dBuV/m)                  (dBuV/m)
 Below 30MHz
   27.12        5.43           19.51     24.94        69.54         -44.60         QP        Face On
   27.12        7.33           19.51     26.84        69.54         -42.70         QP        Face Off
 Above 30MHz
   74.14        15.24          11.06     26.30        40.00         -13.70         QP       Horizontal
  100.33        15.86          11.20     27.06        43.50         -16.44         QP       Horizontal
  126.52        21.13          13.73     34.86        43.50         -8.64          QP       Horizontal
  162.41        20.12          15.19     35.31        43.50         -8.19          QP       Horizontal
  325.37        17.52          15.21     32.73        46.00         -13.27         QP       Horizontal
  379.69        20.12          16.34     36.46        46.00         -9.54          QP       Horizontal
   30.00        21.26          13.77     35.03        40.00         -4.97          QP         Vertical
   38.25        18.13          14.47     32.60        40.00         -7.40          QP         Vertical
   73.17        24.10          11.20     35.30        40.00         -4.70          QP         Vertical
  121.18        16.46          13.41     29.87        43.50         -13.63         QP         Vertical
  162.41        11.21          15.19     26.40        43.50         -17.10         QP         Vertical
  379.69        7.05           16.34     23.39        46.00         -22.61         QP         Vertical
1. The measurements were performed using a loop antenna for below 30MHz. The antenna was
    positioned in two orthogonal (face on and face off) and the position with the highest emission
    level was recorded.
2. For below 30MHz, the limits were calculated as below:
    E field strength (dBuV/m) = 20 log E field strength (uV/m) = 20*log(30) dBuV/m = 29.54 dBuV/m
    Limit (dBuV/m)@3m = Limit (dBuV/m)@30m + 40*Log10 (30/3) = (29.54 + 40) dBuV/m = 69.54
    dBuV/m.
3. Measure Level (dBuV/m) = Reading Level (dBuV) + Factor (dB)
    Factor (dB) = Cable Loss (dB) + Antenna Factor (dB/m).




FCC ID: 2ADI8-SL032                                                               Page Number: 20 of 32


                                                                           Report No.: 1903RSU036-U1



7.4. 20dB Bandwidth

7.4.1.Test Limit
N/A

7.4.2.Test Procedure Used

ANSI C63.10 Clause 6.9.2

7.4.3.Test Setting

1.    The span range shall be two times and five times the OBW
2.    Set RBW = 1% to 5% of the OBW

3.    VBW shall be approximately three times RBW
4.    Detector = Peak
5.    Trace mode = max hold
6.    Sweep = auto couple
7.    Allow the trace was allowed to stabilize and marker the highest level.
8.    Determine the display level (the highest level - 20dB) and place two markers, one at the lowest
      frequency and the other at the highest frequency.

7.4.4.Test Setup




FCC ID: 2ADI8-SL032                                                              Page Number: 21 of 32


                                                                    Report No.: 1903RSU036-U1



7.4.5.Test Result

Product               MIFARE MODULE                Temperature         25°C
Test Engineer         Flag Yang                    Relative Humidity   52%
Test Site             AC1                          Test Time           2019/04/16


                            Bandwidth                                         Limit
                FL                       13.537 MHz                    >13.110 MHz
                FH                       13.586 MHz                    <14.010 MHz
       20dB Bandwidth                                   0.049 MHz
            Result                                           Pass


                                   20dB Spectrum Bandwidth




FCC ID: 2ADI8-SL032                                                       Page Number: 22 of 32


                                                                         Report No.: 1903RSU036-U1



7.5. Frequency Tolerence

7.5.1.Test Limit
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating
frequency.

7.5.2.Test Procedure Used

ANSI C63.10 Clause 6.8

7.5.3.Test Setting

Frequency stability with respect to ambient temperature
a)   Supply the EUT with a nominal ac voltage (120 V)

b)   Couple the EUT output to the measuring instrument by connecting an antenna to the measuring
     instrument with a suitable length of coaxial cable and placing the measuring antenna near the
     EUT (e.g., 15 cm away).
c)   Adjust the location of the measurement antenna and the controls on the measurement
     instrument to obtain a suitable signal level.
d)   Turn the EUT OFF and place it inside the environmental temperature chamber.
e)   Set the temperature control on the chamber to the highest (50 °C) and allow the oscillator heater
     and the chamber temperature to stabilize.
f)   While maintaining a constant temperature inside the environmental chamber, turn the EUT ON

     and record the operating frequency at startup, and at 2 minutes, 5 minutes, and 10 minutes after
     the EUT is energized. Four measurements in total are made.
g)   Switch OFF the EUT but do not switch OFF the oscillator heater.

h)   Lower the chamber temperature by not more that 10 °C, and allow the temperature inside the
     chamber to stabilize.
i)   Repeat step f) through step h) down to the lowest specified temperature (-20 °C).


Frequency stability when varying supply voltage
Unless otherwise specified, these tests shall be made at ambient room temperature (+15 °C to

+25 °C)
a)   Supply the EUT with nominal voltage (120 V). Turn ON the EUT and couple its output to a
     frequency counter or other frequency-measuring instrument.


FCC ID: 2ADI8-SL032                                                              Page Number: 23 of 32


                                                                     Report No.: 1903RSU036-U1



b)   Adjust the location of the measurement antenna and the controls on the measurement
     instrument to obtain a suitable signal level.
c)   Repeat the above procedure at 85% and 115% of the nominal supply voltage.

7.5.4.Test Setup




FCC ID: 2ADI8-SL032                                                         Page Number: 24 of 32


                                                                        Report No.: 1903RSU036-U1


7.5.5.Test Result

Product                 MIFARE MODULE                  Temperature          -20°C ~ 50°C
Test Engineer           Flag Yang                      Relative Humidity    52%
Test Site               TR3                            Test Time            2019/04/19


   Voltage          Power           Temp                   Frequency Tolerance (%)
     (%)            (VAC)           (°C)     0 minutes      2 minutes      5 minutes     10 minutes
                                    - 20      0.0055         0.0051         0.0059         0.0054
                                    - 10      0.0049         0.0053         0.0051         0.0047
                                     0        0.0044         0.0049         0.0041         0.0051
                                    + 10      0.0050         0.0047         0.0053         0.0044
    100%              120
                                + 20 (Ref)    0.0053         0.0051         0.0056         0.0055
                                    + 30      0.0063         0.0062         0.0059         0.0067
                                    + 40      0.0068         0.0064         0.0066         0.0071
                                    + 50      0.0069         0.0063         0.0072         0.0078
    115%              138           + 20      0.0054         0.0052         0.0059         0.0050
    85%               102           + 20      0.0057         0.0054         0.0059         0.0051
Frequency Tolerance (%) = {[Measured Frequency (Hz) - Declared Frequency (Hz)] / Declared
Frequency (Hz)} *100.




FCC ID: 2ADI8-SL032                                                           Page Number: 25 of 32


                                                                        Report No.: 1903RSU036-U1



7.6. AC Conducted Emissions Measurement

7.6.1.Test Limit

                                          FCC 15.207 Limits
       Frequency (MHz)                        QP (dBuV)                        AV (dBuV)
          0.15 ~ 0.50                           66 ~ 56                         56 ~ 46
           0.50 ~ 5.0                              56                              46
            5.0 ~ 30                               60                              50
Note 1: The lower limit shall apply at the transition frequencies.
Note 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to
0.5MHz.

7.6.2.Test Setup




FCC ID: 2ADI8-SL032                                                            Page Number: 26 of 32


                                                                                 Report No.: 1903RSU036-U1



 7.6.3.Test Result
Site: SR2                                              Time: 2019/04/19 - 17:03
Limit: FCC_Part15.207_CE_AC Power                      Engineer: David Lv
Probe: ENV216_101683_Filter On                         Polarity: Line
EUT: MIFARE MODULE                                     Power: AC 120V/60Hz
Test Mode 1




No    Flag   Mark   Frequency   Measure      Reading     Over Limit     Limit        Factor     Type
                    (MHz)       Level        Level       (dB)           (dBuV)       (dB)
                                (dBuV)       (dBuV)
1                   0.154       43.481       32.741      -22.301        65.781       10.740     QP
2                   0.154       17.737       6.997       -38.044        55.781       10.740     AV
3                   0.174       40.872       30.805      -23.895        64.767       10.068     QP
4                   0.174       13.692       3.624       -41.075        54.767       10.068     AV
5                   0.190       35.281       25.252      -28.756        64.037       10.029     QP
6                   0.190       11.461       1.432       -42.575        54.037       10.029     AV
7                   0.250       34.783       24.819      -26.974        61.757       9.964      QP
8                   0.250       15.341       5.377       -36.416        51.757       9.964      AV
9                   0.422       20.000       9.896       -37.409        57.409       10.104     QP
10                  0.422       6.465        -3.638      -40.943        47.409       10.104     AV
11                  0.514       20.757       10.600      -35.243        56.000       10.156     QP
12                  0.514       7.122        -3.034      -38.878        46.000       10.156     AV
13                  13.562      45.760       35.702      N/A            N/A          10.058     QP
14           *      13.562      42.961       32.903      N/A            N/A          10.058     AV
Note 1: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
 Factor (dB) = Cable Loss (dB) + LISN Factor (dB).
FCC ID: 2ADI8-SL032                                                                    Page Number: 27 of 32




                                                                               Report No.: 1903RSU036-U1


Site: SR2                                             Time: 2019/04/19 - 17:12
Limit: FCC_Part15.207_CE_AC Power                     Engineer: David Lv
Probe: ENV216_101683_Filter On                        Polarity: Neutral
EUT: MIFARE MODULE                                    Power: AC 120V/60Hz
Test Mode 1




No   Flag   Mark   Frequency   Measure      Reading      Over Limit   Limit        Factor     Type
                   (MHz)       Level        Level        (dB)         (dBuV)       (dB)
                               (dBuV)       (dBuV)
1                  0.154       38.071       27.355       -27.711      65.781       10.716     QP
2                  0.154       24.048       13.332       -31.734      55.781       10.716     AV
3                  0.182       34.576       24.534       -29.818      64.394       10.042     QP
4                  0.182       19.355       9.312        -35.039      54.394       10.042     AV
5                  0.194       31.464       21.443       -32.400      63.864       10.021     QP
6                  0.194       15.879       5.857        -37.985      53.864       10.021     AV
7                  0.230       33.426       23.440       -29.024      62.450       9.985      QP
8                  0.230       25.781       15.796       -26.668      52.450       9.985      AV
9                  0.298       35.464       25.427       -24.835      60.298       10.036     QP
10                 0.298       29.934       19.897       -20.365      50.298       10.036     AV
11                 5.058       31.383       21.333       -28.617      60.000       10.050     QP
12                 5.058       21.144       11.094       -28.856      50.000       10.050     AV
13                 13.562      50.524       40.424       N/A          N/A          10.100     QP
14          *      13.562      46.708       36.609       N/A          N/A          10.100     AV
Note 1: Measure Level (dBμV) = Reading Level (dBμV) + Factor (dB)
Factor (dB) = Cable Loss (dB) + LISN Factor (dB).
Note 2: 13.56MHz (Point 13 & 14) is the RFID fundamental signal.

FCC ID: 2ADI8-SL032                                                                  Page Number: 29 of 32


                                                                     Report No.: 1903RSU036-U1



8.    CONCLUSION
The data collected relate only the item(s) tested and show that the MIFARE MODULE is in

compliance with Part 15C of the FCC Rules.




                                             The End

FCC ID: 2ADI8-SL032                                                         Page Number: 30 of 32


                                     Report No.: 1903RSU036-U1



Appendix A - Test Setup Photograph
Refer to “1903RSU036-UT” file.




FCC ID: 2ADI8-SL032                        Page Number: 31 of 32


                                 Report No.: 1903RSU036-U1



Appendix B - EUT Photograph
Refer to “1903RSU036-UE” file.




FCC ID: 2ADI8-SL032                    Page Number: 32 of 32



Document Created: 2019-05-08 16:06:06
Document Modified: 2019-05-08 16:06:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC