2ADI8-SL025M_User_Manual

FCC ID: 2ADI8-SL025M

Users Manual

Download: PDF
FCCID_4266148

  RFID MODULE



Mifare Reader / Writer


    SL025M
User Manual




    Version 3.0
     Jan 2018
    StrongLink


StrongLink                                                                                  SL025M

                                        CONTENT
1. MAIN FEATURES .................................................................................3

2. PINNING INFORMATION ...................................................................4

3. BAUD RATE SETTING .........................................................................5

4. COMMUNICATION PROTOCOL.......................................................5

4-1. COMMUNICATION SETTING .....................................................................5
4-2. COMMUNICATION FORMAT .....................................................................5
4-3. COMMAND OVERVIEW ............................................................................6
4-4. COMMAND LIST ......................................................................................7
4-4-1. Select Mifare card ..............................................................................7
4-4-2. Login to a sector .................................................................................7
4-4-3. Download Key into SL025 .................................................................7
4-4-4. Login sector via stored key .................................................................8
4-4-5. Read a data block ...............................................................................8
4-4-6. Write a data block...............................................................................8
4-4-7. Read a value block .............................................................................8
4-4-8. Initialize a value block ........................................................................9
4-4-9. Write master key (key A) ...................................................................9
4-4-10. Increment value ................................................................................9
4-4-11. Decrement value ............................................................................. 10
4-4-12. Copy value ..................................................................................... 10
4-4-13. Read a data page (UltraLight) ......................................................... 10
4-4-14. Write a data Page (UltraLight) ........................................................ 11
4-4-15. Manage Red Led ............................................................................ 11
4-4-16. Get firmware version ...................................................................... 11




http://www.stronglink-rfid.com                                                                           2


StrongLink                                                       SL025M


1. MAIN FEATURES




   • Tags supported: Mifare 1k, Mifare 4k, Mifare UltraLight and NFC
       NTAG203
   • Auto-detecting tag, Built-in antenna
   • UART interface on COMS level, baud rate 9,600 ~ 115,200 bps
   • 4.4 ~ 12.0VDC power supply
   • Work current less than 80mA
   • Operating distance: Up to 70mm, depending on tag
   • Storage temperature: -40 ºC ~ +85 ºC
   • Operating temperature: -25 ºC ~ +70 ºC
   • Dimension: 80 × 55 mm
   • Two LEDs, green led is auto light when tag in detection range, red led
       is controlled by host
   • The OUT pin at low level indicates tag in detective range, and high
       level indicating tag out
   • Support IAP firmware update


http://www.stronglink-rfid.com                                             3


StrongLink                                                               SL025M

2. PINNING INFORMATION




Connector: Würth Elektronik 653 105 131 822

 PIN      SYMBOL             TYPE                  DESCRIPTION
                                      Tag detect signal
   1      TagSta         Output       Logic 0 indicating tag in detection range
                                      Logic 1 indicating tag out
   2      TXD            Output       Serial output port
   3      RXD            Input        Serial input port
   4      VCC            PWR          Power Supply
   5      GND            PWR          Ground




http://www.stronglink-rfid.com                                                    4


StrongLink                                                                 SL025M

3. BAUD RATE SETTING
   Two 820 ohm resistances R6 & R7 are used for setting baud rate as follows sheet

                                 R6               R7            Baud rate bps
                                 no               no                  9,600
                                 yes              no                 19,200
        Assembled                no               yes                57,600
                                                                   115,200
                                 yes              yes
                                                                  ( default )



4. COMMUNICATION PROTOCOL
4-1. Communication Setting
The communication protocol is byte oriented. Both sending and receiving bytes are in
hexadecimal format. The communication parameters are as follows
Baud rate:      9,600 ~ 115,200 bps
Data:           8 bits
Stop:           1 bit
Parity:         None
Flow control:   None


4-2. Communication Format
Host to SL025:
Preamble Len Command Data Checksum
Preamble: 1 byte equal to 0xBA
Len:       1 byte indicating the number of bytes from Command to Checksum
Command: 1 byte Command code, see Table 3
Data:      Variable length depends on the command type
Checksum: 1 byte XOR of all the bytes from Preamble to Data

SL025 to Host:
Preamble Len Command Status Data Checksum
Preamble: 1 byte equal to 0xBD
Len:       1 byte indicating the number of bytes from Command to Checksum
Command: 1 byte Command code, see Table 3
Status:    1 byte Command status, see Table 4
Data:      Variable length depends on the command type.
Checksum: 1 byte XOR of all the bytes from Preamble to Data




http://www.stronglink-rfid.com                                                       5


StrongLink                                              SL025M

4-3. Command Overview
Table 3
Command      Description
0x01         Select Mifare card
0x02         Login to a sector
0x03         Read a data block
0x04         Write a data block
0x05         Read a value block
0x06         Initialize a value block
0x07         Write master key (key A)
0x08         Increment value
0x09         Decrement value
0x0A         Copy value
0x10         Read a data page (UltraLight & NTAG203)
0x11         Write a data page (UltraLight & NTAG203)
0x12         Download Key
0x13         Login sector via stored Key
0x40         Manage Red Led
0xF0         Get firmware version


Status Overview
Table 4
Status      Description
0x00        Operation succeed
0x01        No tag
0x02        Login succeed
0x03        Login fail
0x04        Read fail
0x05        Write fail
0x06        Unable to read after write
0x08        Address overflow
0x09        Download Key fail
0x0D        Not authenticate
0x0E        Not a value block
0xF0        Checksum error
0xF1        Command code error




http://www.stronglink-rfid.com                               6


StrongLink                                                            SL025M

4-4. Command List
4-4-1. Select Mifare card
0xBA Len 0x01 Checksum
Response:
0xBD Len 0x01 Status             UID     Type Checksum
Status: 0x00: Operation succeed
         0x01: No tag
         0xF0: Checksum error
UID: The uniquely serial number of Mifare card,
Type: 0x01: Mifare 1k, 4 byte UID
         0x02: Mifare 1k, 7 byte UID [1]
         0x03: Mifare UltraLight or NATG203 [2], 7 byte UID
         0x04: Mifare 4k, 4 byte UID
         0x05: Mifare 4k, 7 byte UID [1]
         0x06: Mifare DesFire, 7 byte UID
         0x0A: Other


4-4-2. Login to a sector
0xBA Len 0x02 Sector Type Key Checksum
Sector: Sector need to login, 0x00 – 0x27
Type: Key type (0xAA: authenticate with KeyA, 0xBB: authenticate with KeyB)
Key:    Authenticate key, 6 bytes
Response:
0xBD Len 0x02 Status Checksum
Status: 0x02: Login succeed
        0x01: No tag
        0x03: Login fail
        0x08: Address overflow
        0xF0: Checksum error


4-4-3. Download Key into SL025
0xBA Len 0x12 Sector Type Key                  Checksum
Sector: 0x00 – 0x27
Type: Key type (0xAA: KeyA, 0xBB: KeyB)
Key:    6 bytes, stored into SL025
Response:
0xBD Len 0x12 Status Checksum
Status: 0x00: Operation succeed
        0x08: Address overflow
        0x09: Download fail
        0xF0: Checksum error



http://www.stronglink-rfid.com                                                7


StrongLink                                                    SL025M
4-4-4. Login sector via stored key
0xBA Len 0x13 Sector Type Checksum
Sector: Sector need to login, 0x00 – 0x27
Type: Key type (0xAA: KeyA, 0xBB: KeyB)
Response:
0xBD Len 0x13 Status Checksum
Status: 0x02: Login succeed
        0x03: Login fail
        0x08: Address overflow
        0xF0: Checksum error


4-4-5. Read a data block
0xBA Len 0x03 Block Checksum
Block: The absolute address of block to be read, 1 byte
Response:
0xBD Len 0x03 Status Data Checksum
Status: 0x00: Operation succeed
        0x01: No tag
        0x04: Read fail
        0x0D: Not authenticate
        0xF0: Checksum error
Data: Block data returned if operation succeeds, 16 bytes.


4-4-6. Write a data block
0xBA Len 0x04 Block Data Checksum
Block: The absolute address of block to be written, 1 byte.
Data: The data to write, 16 bytes.
Response:
0xBD Len 0x04 Status Data Checksum
Status: 0x00: Operation succeed
        0x01: No tag
        0x05: Write fail
        0x06: Unable to read after write
        0x0D: Not authenticate
        0xF0: Checksum error
Data: Block data written if operation succeeds, 16 bytes.


4-4-7. Read a value block
0xBA Len 0x05 Block Checksum
Block: The absolute address of block to be read, 1 byte.
Response:
0xBD Len 0x05 Status Value                Checksum
Status: 0x00: Operation succeed


http://www.stronglink-rfid.com                                     8


StrongLink                                                            SL025M
        0x01: No tag
        0x04: Read fail
        0x0D: Not authenticate
        0x0E: Not a value block
        0xF0: Checksum error
Value : Value returned if the operation succeeds, 4 bytes.


4-4-8. Initialize a value block
0xBA Len 0x06 Block Value                   Checksum
Block: The absolute address of block to be initialized, 1 byte.
Value: The value to be written, 4 bytes.
Response:
0xBD Len 0x06 Status Value                  Checksum
Status: 0x00: Operation succeed
         0x01: No tag
         0x05: Write fail
         0x06: Unable to read after write
         0x0D: Not authenticate
         0xF0: Checksum error
Value : Value written if the operation succeeds, 4 bytes.


4-4-9. Write master key (key A)
0xBA Len 0x07 Sector Key Checksum
Sector: The sector number to be written, 0x00 – 0x27
Key:      Authentication key, 6 bytes
Response:
0xBD Len 0x07 Status Key Checksum
Status: 0x00: Operation succeed
          0x01: No tag
          0x05: Write fail
          0x08: Address overflow
          0x0D: Not authenticate
          0xF0: Checksum error
Key:      Authentication key written if the operation succeeds, 6 bytes.
Attention: Be sure KeyB is readable, otherwise KeyB will be change to 000000000000
after this command.


4-4-10. Increment value
0xBA Len 0x08 Block Value                 Checksum
Block: The absolute address of block to be increased, 1 byte.
Value: The value to be increased by, 4 bytes.
Response:
0xBD Len 0x08 Status Value                Checksum


http://www.stronglink-rfid.com                                                   9


StrongLink                                                            SL025M
Status: 0x00: Operation succeed
        0x01: No tag
        0x05: Write fail
        0x06: Unable to read after write
        0x0D: Not authenticate
        0x0E: Not a value block
        0xF0: Checksum error
Value: The value after increment if the operation succeeds, 4 bytes


4-4-11. Decrement value
0xBA Len 0x09 Block Value                 Checksum
Block: The absolute address of block to be decreased, 1 byte
Value: The value to be decreased by, 4 bytes
Response:
0xBD Len 0x09 Status Value                Checksum
Status: 0x00: Operation succeed
         0x01: No tag
         0x05: Write fail
         0x06: Unable to read after write
         0x0D: Not authenticate
         0x0E: Not a value block
         0xF0: Checksum error
Value: The value after decrement if the operation succeeds, 4 bytes


4-4-12. Copy value
0xBA Len 0x0A Source Destination Checksum
Source:      The source block copy from, 1 byte
Destination: The destination copy to, 1 byte
Attention: The source and destination must in the same sector
Response:
0xBD Len 0x0A Status Value                  Checksum
Status: 0x00: Operation succeed
         0x01: No tag
         0x05: Write fail
         0x06: Unable to read after write
         0x0D: Not authenticate
         0x0E: Not a value block (Source)
         0xF0: Checksum error
Value: The value after copy if the operation succeeds, 4 bytes


4-4-13. Read a data page (UltraLight & NTAG203)
0xBA Len 0x10 Page              Checksum
Page: The page number to be read, 0x00 – 0x0F


http://www.stronglink-rfid.com                                             10


StrongLink                                                         SL025M
Response:
0xBD Len 0x10 Status Data Checksum
Status: 0x00: Operation succeed
        0x01: No tag
        0x04: Read fail
        0x08: Address overflow
        0xF0: Checksum error
Data: Block data returned if operation succeeds, 4 bytes.


4-4-14. Write a data Page (UltraLight & NTAG203)
0xBA Len 0x11 Page                Data Checksum
Page: The page number to be written, 0x00 – 0x0F
Data: The data to write, 4 bytes.
Response:
0xBD Len 0x11 Status Data Checksum
Status: 0x00: Operation succeed
        0x01: No tag
        0x05: Write fail
        0x06: Unable to read after write
        0x08: Address overflow
        0xF0: Checksum error
Data: Page data written if operation succeeds, 4 bytes.


4-4-15. Manage Red Led
0xBA Len 0x40 Code            Checksum
Code: 0 command red led turn off , other red led turn on, 1 byte
Return:
0xBD Len 0x40         Status Checksum
Status: 0x00: Operation succeed
        0xF0: Checksum error


4-4-16. Get firmware version
0xBA Len 0xF0 Checksum
Response: [3]
0xBD Len 0xF0 Status Data                Checksum
Status: 0x00: Operation success
        0xF0: Checksum error
Data: firmware version.




http://www.stronglink-rfid.com                                          11


StrongLink                                                                  SL025M

Remark
   [1]
       In order to support 7 byte UID Mifare class, the firmware of SL025 has been
   updated to Ver1.2 in Mar 2011.
   And older firmware version (such as Ver1.0, 1.1) only supports 4 byte UID.
   Please refer to NXP Customer Letter UID for detailed information of 4 byte & 7 byte
   UID of Mifare products.

   [2]
       To support NATG203, the firmware of SL025 has been updated to Ver1.6 in May
   2012. The older firmware version only supports reading/writing data page address less
   than 16.
   [3]
         One sample of SL025 response
              Preamble Len Command          Status   Data                    Checksum
                                                     (Firmware version)
    HEX      BD          15      F0         00       53 4C 30 32 35 2D 33    69
                                                     2E 30 2D 32 30 31 36
                                                     31 31 31 34
    ASCII                                            “SL025-3.0-20161114
                                                     ”




http://www.stronglink-rfid.com                                                        12


Federal Communications Commission (FCC) Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part15 of the FCC Rules.


These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications.


However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one of
the following measures:


   Reorient or relocate the receiving antenna.
   Increase the separation between the equipment and receiver.
   Connect the equipment into an outlet on a circuit different from that to which the receiver is
    connected.
   Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.


RF exposure warning


This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment.
This product may not be collocated or operated in conjunction with any other antenna or transmitter
This equipment must be installed and operated in accordance with provided instructions and the
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20
cm from all persons and must not be collocated or operating in conjunction with any other antenna or
transmitter.


OEM Integration Instructions:

This device is intended only for OEM integrators under the following conditions:
The module can be used to installation in other host. The antenna must be installed such that 20 cm is
maintained between the antenna and users, and the transmitter module may not be co-located with
any other transmit or antenna. The module shall be only used with the integral antenna(s) that has
been originally tested and certified with this module. As long as 3 conditions above are met, further
transmitter test will not be required. However, the OEM integrator is still responsible for testing their
end-product for any additional compliance requirement with this module installed (for example, digital
device emission, PC peripheral requirements, etc.)


IMPORTANT NOTE:

In the event that these conditions cannot be met (for example certain laptop configuration or
co-location with another transmitter), then the FCC authorization for this module in combination with
the host equipment is no longer considered valid and the FCC ID of the module cannot be used on the
final product. In these and circumstance, the OEM integrator will be responsible for re-evaluating. The
end product (including the transmitter) and obtaining a separate FCC authorization. The final end
product must be labeled in a visible area with the following:
“Contains Transmitter Module FCC ID: 2ADI8-SL025M or Contains FCC ID: 2ADI8-SL025M”.