MPE

FCC ID: 2ADHKATWINC1500

RF Exposure Info

Download: PDF
FCCID_3886292

MET Laboratories, Inc.                            Safety Certification - EMI - Telecom Environmental Simulation
914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230-3432 • PHONE (410) 354-3300 • FAX (410) 354-3313
33439 WESTERN AVENUE • UNION CITY, CALIFORNIA 94587 • PHONE (510) 489-6300 • FAX (510) 489-6372
3162 BELICK STREET • SANTA CLARA, CA 95054 • PHONE (408) 748-3585 • FAX (510) 489-6372
13501 MCCALLEN PASS • AUSTIN, TEXAS 78753 • PHONE (512) 287-2500 • FAX (512) 287-2513




May 29, 2018


Heatworks Technologies Inc
2353 Hwy 17 N
Mount Pleasant, SC 29466


Dear Michael Wieckowski,

Enclosed is the EMC Wireless test report for compliance testing of the Heatworks Technologies Inc, Heatworks
MODEL 3 Tankless Water Heater as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part
15 Subpart C for Intentional Radiators.

Thank you for using the services of MET Laboratories, Inc. If you have any questions regarding these results or
if MET can be of further service to you, please feel free to contact me.

Sincerely yours,
MET LABORATORIES, INC.




Joel Huna
Documentation Department


Reference: (\Heatworks Technologies Inc\EMC98105-MPE Rev. 1)




Certificates and reports shall not be reproduced except in full, without the written permission of MET Laboratories, Inc.




                           The Nation’s First Licensed Nationally Recognized Testing Laboratory


                                                                                              Electromagnetic Compatibility
Heatworks Technologies Inc                                                                                       Cover Page
Heatworks MODEL 3 Tankless Water Heater                                                            CFR Title 47, Part 15.247




                                Electromagnetic Compatibility Criteria
                                            Test Report

                                                           for the

                                       Heatworks Technologies Inc
                                Heatworks MODEL 3 Tankless Water Heater


                                                       Tested under
                                                 the FCC Certification Rules
                                                        contained in
                                          15.247 Subpart C for Intentional Radiators



                                    MET Report: EMC98105-MPE Rev. 1

                                                      May 29, 2018


                                                     Prepared For:

                                             Heatworks Technologies Inc
                                                  2353 Hwy 17 N
                                              Mount Pleasant, SC 29466


                                                                                                               Prepared By:
                                                                                                 MET Laboratories, Inc.
                                                                           914 West Patapsco Avenue, Baltimore, MD 21230




MET Report: EMC98105-MPE Rev. 1                   © 2018, MET Laboratories, Inc.                                   Page ii of iv

DOC-EMC702 6/18/2009


                                                                                                          Electromagnetic Compatibility
Heatworks Technologies Inc                                                                                                   Cover Page
Heatworks MODEL 3 Tankless Water Heater                                                                        CFR Title 47, Part 15.247




                                        Electromagnetic Compatibility Criteria
                                                    Test Report

                                                                for the

                                           Heatworks Technologies Inc
                                    Heatworks MODEL 3 Tankless Water Heater


                                                          Tested under
                                                    the FCC Certification Rules
                                                           contained in
                                             15.247 Subpart C for Intentional Radiators




          Arsalan Hasan, Project Engineer                                                 Joel Huna
          Electromagnetic Compatibility Lab                                               Documentation Department




Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the
emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and
completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the
measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Part 15.247
under normal use and maintenance.




                                                           John Mason,
                                           Director, Electromagnetic Compatibility Lab




MET Report: EMC98105-MPE Rev. 1                        © 2018, MET Laboratories, Inc.                                         Page iii of iv

DOC-EMC702 6/18/2009


                                                                                               Electromagnetic Compatibility
Heatworks Technologies Inc                                                                                     Report Status
Heatworks MODEL 3 Tankless Water Heater                                                             CFR Title 47, Part 15.247



                                          Report Status Sheet

  Revision               Report Date                                    Reason for Revision

                        May 14, 2018                                         Initial Issue.

      1                  May 29, 2018                                       TCB Corrections.




MET Report: EMC98105-MPE Rev. 1            © 2018, MET Laboratories, Inc.                                          Page iv of iv

DOC-EMC702 6/18/2009


                                                                           Electromagnetic Compatibility
Heatworks Technologies Inc                                                          Executive Summary
Heatworks MODEL 3 Tankless Water Heater                                         CFR Title 47, Part 15.247




    I.           Executive Summary




MET Report: EMC98105-MPE Rev. 1           © 2018, MET Laboratories, Inc.                         Page 1 of 9
DOC-EMC702 6/18/2009


                                                                                           Electromagnetic Compatibility
Heatworks Technologies Inc                                                                          Executive Summary
Heatworks MODEL 3 Tankless Water Heater                                                         CFR Title 47, Part 15.247


A.       Purpose of Test

         An EMC evaluation was performed to determine compliance of the Heatworks Technologies Inc Heatworks
         MODEL 3 Tankless Water Heater, with the requirements of Part 15, §15.247. All references are to the most
         current version of Title 47 of the Code of Federal Regulations in effect. In accordance with §2.1033, the
         following data is presented in support of the Certification of the Heatworks MODEL 3 Tankless Water Heater.
         Heatworks Technologies Inc should retain a copy of this document which should be kept on file for at least two
         years after the manufacturing of the Heatworks MODEL 3 Tankless Water Heater, has been permanently
         discontinued.

B.       Executive Summary

         The following tests were conducted on a sample of the equipment for the purpose of demonstrating compliance
         with Part 15, §15.247, in accordance with Heatworks Technologies Inc, purchase order number ISI.900453. All
         tests were conducted using measurement procedure ANSI C63.4-2014.


            FCC Reference
                                                               Description                           Compliance
        47 CFR Part 15.247:2005
  Title 47 of the CFR, Part 15 §15.247(i)        Maximum Permissible Exposure (MPE)                    Compliant
Table 1. Executive Summary of EMC Part 15.247 ComplianceTesting




MET Report: EMC98105-MPE Rev. 1                © 2018, MET Laboratories, Inc.                                    Page 2 of 9
DOC-EMC702 6/18/2009


                                                                           Electromagnetic Compatibility
Heatworks Technologies Inc                                                      Equipment Configuration
Heatworks MODEL 3 Tankless Water Heater                                         CFR Title 47, Part 15.247




    II.          Equipment Configuration




MET Report: EMC98105-MPE Rev. 1           © 2018, MET Laboratories, Inc.                         Page 3 of 9

DOC-EMC702 6/18/2009


                                                                                               Electromagnetic Compatibility
Heatworks Technologies Inc                                                                          Equipment Configuration
Heatworks MODEL 3 Tankless Water Heater                                                             CFR Title 47, Part 15.247

A.       Overview
         MET Laboratories, Inc. was contracted by Heatworks Technologies Inc to perform testing on the Heatworks
         MODEL 3 Tankless Water Heater, under Heatworks Technologies Inc’s purchase order number ISI.900453.

         This document describes the test setups, test methods, required test equipment, and the test limit criteria used to
         perform compliance testing of the Heatworks Technologies Inc, Heatworks MODEL 3 Tankless Water Heater.

         The results obtained relate only to the item(s) tested.

           Model(s) Tested:     Heatworks MODEL 3 Tankless Water Heater

          Model(s) Covered:     Heatworks MODEL 3 Tankless Water Heater




                        EUT
                                Primary Power: 100 to 240 VAC 50-60 Hz
              Specifications:




                   Analysis:    The results obtained relate only to the item(s) tested.
              Evaluated by:     Arsalan Hasan

             Report Date(s):    May 29, 2018

       Table 2. EUT Summary Table


B.       References

                                        Federal Communication Commission, Code of Federal Regulations, Title 47,
      CFR 47, Part 15, Subpart C        Part 15: General Rules and Regulations, Allocation, Assignment, and Use of
                                        Radio Frequencies
                                        Methods and Measurements of Radio-Noise Emissions from Low-Voltage
      ANSI C63.4:2014
                                        Electrical And Electronic Equipment in the Range of 9 kHz to 40 GHz
                                        General Requirements for the Competence of Testing and Calibration
      ISO/IEC 17025:2005
                                        Laboratories
      ANSI C63.10-2013                  American National Standard for Testing Unlicensed Wireless Devices

     Table 3. References


C.       Test Site
         All testing was performed at MET Laboratories, Inc., 914 West Patapsco Avenue, Baltimore, MD 21230. All
         equipment used in making physical determinations is accurate and bears recent traceability to the National
         Institute of Standards and Technology.

         Radiated Emissions measurements were performed in a 3 meter semi-anechoic chamber (equivalent to an Open
         Area Test Site). In accordance with §2.948(a)(3), a complete site description is contained at MET Laboratories.

MET Report: EMC98105-MPE Rev. 1                    © 2018, MET Laboratories, Inc.                                    Page 4 of 9

DOC-EMC702 6/18/2009


                                                                                                                      Electromagnetic Compatibility
Heatworks Technologies Inc                                                                                                 Equipment Configuration
Heatworks MODEL 3 Tankless Water Heater                                                                                    CFR Title 47, Part 15.247



D.         Description of Test Sample
           The Heatworks Technologies Inc Heatworks MODEL 3 Tankless Water Heater, Equipment Under Test (EUT), is
           a tankless electric (on demand) water heater for residential potable water systems. It can be installed for whole
           home use, or at distributed various points of use. The EUT will heat flowing water to a chosen temperature
           setpoint using electrical energy.




                                                                                       (1)



                                                         (5)

                                                   UART over USB
                                                                                                                        240 VAC, 100 A

                                                                                                        (2)                   L1

                           (6)                                        (4)                                                      Earth Ground
                                                                                                                              L2

                                                                                     (3)
                                                                 Cold Water In          Hot Water Out
                                                                  3/4” NPT                3/4” NPT

                                             Figure 1. Block Diagram of Test Configuration


E.         Equipment Configuration
           The EUT was set up as outlined in Figure 1, Block Diagram of Test Setup. All cards, racks, etc., incorporated as
           part of the EUT is included in the following list.


Ref. ID       Slot #             Name / Description                Model Number               Part Number            Serial Number            Rev. #
     1                     MODEL 3 Water Heater                       MODEL 3
  Table 4. Equipment Configuration


F.         Support Equipment
           Support equipment necessary for the operation and testing of the EUT is included in the following list.

                                                                                                                           *Customer Supplied
Ref. ID              Name / Description                        Manufacturer                  Model Number
                                                                                                                            Calibration Data
     6             Laptop with USB port
The ‘Customer Supplied Calibration Data’ column will be marked as either not applicable, not available, or will contain the calibration date supplied by
the customer.

Table 5. Support Equipment

MET Report: EMC98105-MPE Rev. 1                                © 2018, MET Laboratories, Inc.                                                  Page 5 of 9

DOC-EMC702 6/18/2009


                                                                                              Electromagnetic Compatibility
Heatworks Technologies Inc                                                                         Equipment Configuration
Heatworks MODEL 3 Tankless Water Heater                                                            CFR Title 47, Part 15.247

G.        Ports and Cabling Information

                                                                       Length      Max     Shielded
               Port name on        Cable Description or                                                  Termination Box
Ref. ID                                                       Qty     as tested   Length      ?
                   EUT              reason for no cable                                                  ID & Port Name
                                                                         (m)       (m)      (Y/N)
                                    3 conductor, 4 awg          1
     2           AC Input                                                                      N
                                          THHN
                                 Flexible hose adapted to       1
     3         Hot water out
                                      ¾” NPT fitting
                                 Flexible hose adapted to       1
     4         Cold water in
                                      ¾” NPT fitting
     5          USB Debug           USB cable (Micro)           1          5                   Y

 Table 6. Ports and Cabling Information


H.        Mode of Operation
          Normal Operation:
          With water flowing at a common rate (1 to 2 GPM) and a temperature set point around 100-110 F, the unit will
          periodically send information over WiFi and accept connections over Bluetooth LE.

I.        Method of Monitoring EUT Operation
          #1 – The unit is drawing AC current (measurable) commensurate with heating of the water. Also, data should be
          visible via the WiFi-cloud platform and Bluetooth LE connections should be possible.

          #2 – Error codes on the EUT screen, loss of visible lights on the EUT, no data from cloud platform, no BLE
          broadcast.

J.        Modifications
          a)       Modifications to EUT

                   No modifications were made to the EUT.

          b)       Modifications to Test Standard

                   No modifications were made to the test standard.

K.        Disposition of EUT
          The test sample including all support equipment submitted to the Electro-Magnetic Compatibility Lab for testing
          was returned to Heatworks Technologies Inc upon completion of testing.




MET Report: EMC98105-MPE Rev. 1                  © 2018, MET Laboratories, Inc.                                     Page 6 of 9

DOC-EMC702 6/18/2009


                                                                                             Electromagnetic Compatibility
Heatworks Technologies Inc                                                                  Maximum Permissible Exposure
Heatworks MODEL 3 Tankless Water Heater                                                           CFR Title 47, Part 15.247




Electromagnetic Compatibility Criteria for Intentional Radiators

        § 15.247(i)       Maximum Permissible Exposure


RF Exposure Requirements:          §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this
                                   section shall be operated in a manner that ensures that the public is not exposed to
                                   radio frequency energy levels in excess of the Commission’s guidelines.

RF Radiation Exposure Limit:       §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE)
                                   Limit shall be used to evaluate the environmental impact of human exposure to
                                   radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of
                                   portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of
                                   this chapter.
Note:                              Co-located transmitters are 2.4GHz BLE and 2.4GHz WiFi




                 Equation from page 18 of OET 65, Edition 97-01

                          S = PG / 4R2      or       R = √(PG / 4S)

                 where, S = Power Density (mW/cm2)
                        P = Power Input to antenna (mW)
                        G = Antenna Gain (numeric value)
                        R = Distance (cm)

                           G(dBi) = 10 log G (linear)




MET Report: EMC98105-MPE Rev. 1                   © 2018, MET Laboratories, Inc.                                   Page 7 of 9
DOC-EMC702 6/18/2009


                                                                                           Electromagnetic Compatibility
Heatworks Technologies Inc                                                                Maximum Permissible Exposure
Heatworks MODEL 3 Tankless Water Heater                                                         CFR Title 47, Part 15.247




Test Results:

Results are based on KDB 447498 [Section 7.2]. Transmitters used in mobile device exposure conditions for simultaneous
transmission operations.

MPE Result for Intentional Radiators above 1500 MHz.
Note: Tune Up Tolerance is [+/-] 1dB for WiFi and BLE radios.



MPE Result for Intentional Radiators of Frequency Range: 300 MHZ – 1500 MHz



                Conducted      Conducted       Ant                                       Limit at 20
 Frequency                                               Ant Gain       Power Density                     Percentage
                 Power          Power         Gain                                          cm
   (MHz)                                                  (dBi)          (mW/cm^2)                        of Limit (%)
                 (dBm)           (mW)         (dBi)                                     (mW/cm^2)



2440 (BLE)          1.38          1.374       -0.5         0.891            0.00024          1                0.024


2437 (WiFi)        23.03          200.9        -3          0.501            0.02003          1                2.003


BLE Module FCC-ID: WAP2011
2402 MHz – 2478 MHz



WiFi Module FCC-ID: 2ADHKATWINC1500
2412 MHz – 2462 MHz
Mode: b, g, n


The BLE and WiFi radios transmit simulateously. The combined percentage is lower than the limit of 100%.

The safe distance where Power Density is less than the MPE Limit listed above was found to be 20 cm.




MET Report: EMC98105-MPE Rev. 1                © 2018, MET Laboratories, Inc.                                    Page 8 of 9
DOC-EMC702 6/18/2009


                                                                           Electromagnetic Compatibility
Heatworks Technologies Inc                                                                 End of Report
Heatworks MODEL 3 Tankless Water Heater                                         CFR Title 47, Part 15.247




                                   End of Report




MET Report: EMC98105-MPE Rev. 1           © 2018, MET Laboratories, Inc.                         Page 9 of 9
DOC-EMC702 6/18/2009



Document Created: 2019-10-12 05:54:16
Document Modified: 2019-10-12 05:54:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC