Test Result of RF Exposure Evaluation
  According to the KDB-447498 D01 V05, FCC 47CFR§2.1093, the following RF exposure
evaluation shall to demonstrate RF exposure compliance.
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance,mm)]
* [√f(GHz)]


                               maximum          Maximum         Separation
                Frequency                                                          RF
                                tune up          Output          distance
                   GHz                                                          exposure
                              power : dBm      Power: mW           mm
     GFSK         2.402           1.0              1.26             5              0.39




The Max RF exposure is 0.39.
Threshold at which no SAR required is≤ 3.0 for 1-g SAR, Separation distance is 5mm.

Conclusion: