                                                              TEST REPORT

                                        Etherstack Inc. SFFR615WUH1
                                        UHF Small Form Factor Repeater

                                                                                  tested to

                                               47 Code of Federal Regulations

                                           Part 15 - Radio Frequency Devices

                                                                      Subpart A + B

                                                                                       for


                                                                      Etherstack Inc.




This Test Report is issued with the authority of:
                                                                                                           _______________________________
                                                                                                                   Andrew Cutler - General Manager




____________________________________________________________________________________________________________________________________________________________________________

Page 1 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


                                                            Table of Contents



1.       STATEMENT OF COMPLIANCE                                                                                                                                               3

2.       RESULTS SUMMARY                                                                                                                                                        3

3.       INTRODUCTION                                                                                                                                                           3

4.       CLIENT INFORMATION                                                                                                                                                    4

5.       TEST SAMPLE DESCRIPTION                                                                                                                                                4

6.       RESULTS                                                                                                                                                                5

7.       TEST EQUIPMENT USED                                                                                                                                                   13

8.       ACCREDITATIONS                                                                                                                                                        13

9.       PHOTOGRAPHS                                                                                                                                                           14




____________________________________________________________________________________________________________________________________________________________________________

Page 2 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


1.            STATEMENT OF COMPLIANCE
The Etherstack Inc. SFFR615WUH1 UHF Small Form Factor Repeater complies as a
FCC Part 15 Class B Computer Peripheral device when the Class B limits contained within
Subparts A + B are applied and when the methods described in ANSI C63.4 - 2003 are
applied.


2.            RESULTS SUMMARY
The results of testing, carried out between 12th and the 27th November 2014, are summarised
below.

 Clause Parameter                                                                   Result
 15.101 Equipment authorisation                                                     This device would be classed as a Class B
        requirement.                                                                computer peripheral and would be subject to
                                                                                    certification.

                                                                                    The device also contains a receiver that would
                                                                                    be subject to the verification process.
 15.103 Exempted devices.                                                           Device is not exempt as it contains a receiver
                                                                                    and a digital device.

 15.107             Conducted Emissions                                             Complies.
                    0.15 - 30 MHz

 15.109             Radiated Emissions                                              Complies.
                    30 - 2000 MHz

 15.111             Antenna Terminal Disturbance                                    Complies.
                    30 – 950 MHz


3.            INTRODUCTION
This report describes the tests and measurements performed for the purpose of determining
compliance with the specification.

The client selected the test sample.

This report relates only to the sample tested.

This report contains no corrections or erasures.

Measurement uncertainties with statistical confidence intervals of 95% are shown below test
results. Both Class A and Class B uncertainties have been accounted for, as well as influence
uncertainties where appropriate.

All compliance statements have been made with respect of the specification limit with no
reference to the measurement uncertainty.

____________________________________________________________________________________________________________________________________________________________________________

Page 3 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


4.            CLIENT INFORMATION

Company Name                               Etherstack Inc.

Address                                    1115 Broadway, Suite 1276,
                                           New York, NY 10010

Country                                    United States of America

Contact                                    Mr Doug Chapman


5.            TEST SAMPLE DESCRIPTION
Brand Name                                 Etherstack Inc.

Model Number                               SFFR615WUH1

Product                                    UHF Small Form Factor Repeater

Manufacturer                               Etherstack London Ltd

Country of Origin                          Australia

Serial Number                              1200018

FCC ID                                     2ADAKSFFR615WUH1

The SFFR615WUH1 is a small form factor portable repeater that is self-powered and can
operate as an APCO P25 standalone repeater.

Power Supply:

          DC Supply 12 Vdc 10.8 – 15.6 volt dc Max 10 amps

          AC Supply: 100 - 240 Vdc (47-63 Hz)

          Internal Batteries 11.25 Vdc Li-ION rechargeable x 2

Receiver test frequencies

               Frequency                                             Spacing
                 (MHz)                                                (kHz)
                380.000                                                12.5
                450.000                                                12.5
                520.000                                                12.5



____________________________________________________________________________________________________________________________________________________________________________

Page 4 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


6.            RESULTS
Standard

The sample was tested in accordance with 47 CFR Part 15 Subpart A and B with the Class B
limits being applied.

Standard

The sample was tested in accordance with 47 CFR Part 15 Subpart A and B.

Methods and Procedures

The following measurement methods and procedures have been applied:

-             ANSI C63.4 – 2003


Section 15.101: Equipment authorisation requirement

This device would be classed as a Class B Computer Peripheral to which the Certification
process has been applied.

The device also contains a Receiver contained within a Transceiver which would be subjected
to the Verification process.

This test report contains test results for both devices and both processes with the process being
indicated in brackets with regard the results being presented.




____________________________________________________________________________________________________________________________________________________________________________

Page 5 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Section 15.107: Conducted limits (Certification and Verification)

Conducted emission testing has been carried out when the device was powered at 120 Vac 60
Hz using a representative AC power supply.

Conducted emission testing was carried out over the frequency range of 150 kHz to 30 MHz
at the Laboratory’s MacKelvie Street premises in a 2.4 m x 2.4 m x 2.4 m screened room.

Testing was carried out in accordance with section 15.107(a) using a measuring receiver and a
50 uH / 50 ohm artificial mains network which is also known as a line impedance stabilisation
network (LISN).

Measurements on both the phase and neutral lines were made using either a Quasi Peak or an
Average detector with a 9 kHz bandwidth.

The supplied conducted emission plot is a combined plot showing the worst case of the Peak,
Quasi Peak and Average levels for both phase and neutral.

The Class B conducted limits have been applied.

Result: Complies.
Measurement uncertainty with a confidence interval of 95% is:
Conducted emissions tests (0.15 - 30 MHz)  2.2 dB




____________________________________________________________________________________________________________________________________________________________________________

Page 6 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Conducted Emissions – AC Input Power Port

  Setup:           Device transmitting continuously into a dummy load with the digital device active when powered
                   by 120 Vac 60 Hz
                                                                                         Peak ---            Average --            Quasi Peak       X          Average +


      Level [dBµV]
     80




     60

                                         x
                                                                                            xx
                                                                                                     x
     40                                                                                                                   +
                                      +                   +



     20




        0




  -20
            150k           300k              500k                 1M         2M                      3M              5M        7M 10M                                 30M
                                                                  Frequency [Hz]


Final Quasi-Peak Measurements
    Frequency          Level                                          Limit                       Margin                          Phase                     Rechecks
       MHz             dBV                                           dBV                          dB                                                       dBV
    0.399000           51.20                                          57.9                         6.7                             L1
    2.103500           49.20                                          56.0                         6.8                             L1
    2.346500           49.20                                          56.0                         6.8                             L1
    2.814500           44.50                                          56.0                        11.5                             L1

Final Average Measurements
    Frequency         Level                                           Limit                       Margin                          Phase                     Rechecks
       MHz            dBV                                            dBV                          dB                                                       dBV
    0.372000          38.20                                           48.5                        10.3                             L1
    0.705000          38.50                                           46.0                         7.5                             L1
    5.604500          40.70                                           50.0                         9.3                             L1




____________________________________________________________________________________________________________________________________________________________________________

Page 7 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Conducted Emissions – AC Input Power Port

  Setup:           Device in Receive / Standby mode with the digital device active when powered at 120 Vac 60 Hz.
                                                                                         Peak ---            Average --            Quasi Peak       X          Average +


      Level [dBµV]
     80




     60

                                                                                               x
                                                                                              x
     40                                                   +
                                                                                +      x



     20




        0




  -20
            150k           300k            500k                   1M         2M                      3M              5M        7M 10M                                 30M
                                                                  Frequency [Hz]


Final Quasi-Peak Measurements
    Frequency          Level                                          Limit                        Margin                         Phase                     Rechecks
       MHz             dBV                                           dBV                           dB                                                      dBV
    1.806000           35.50                                          56.0                         20.5                            L1
    2.247500           46.70                                          56.0                          9.3                            L1
    2.351000           50.30                                          56.0                          5.7                            L1
    2.360000           50.90                                          56.0                          5.1                            L1

Final Average Measurements
    Frequency         Level                                           Limit                        Margin                         Phase                     Rechecks
       MHz            dBV                                            dBV                           dB                                                      dBV
    0.708000          38.30                                           46.0                          7.7                            L1
    1.413000          36.40                                           46.0                          9.6                            L1




____________________________________________________________________________________________________________________________________________________________________________

Page 8 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Section 15.109: Radiated spurious emissions

Radiated emission testing was carried out over the frequency range of 30 to 2000 MHz as the
highest frequency in use in the digital device is less than 500 MHz.

The 2nd harmonic of the highest receiver local oscillator frequency is less than 2000 MHz
(1220 MHz).

Testing was carried out at the laboratory’s open area test site - located at 670 Kawakawa Orere
Rd, RD3, Papakura, New Zealand.

Before testing was carried out, a receiver Self Test and Internal Calibration was undertaken
along with a check of all connecting cables and programmed antenna factors.

The device was placed on the test tabletop, which was a total of 0.8 m above the test site
ground plane.

Measurements below 1000 MHz were made using a Quasi Peak Detector with a bandwidth of
120 kHz.

Above 1000 MHz measurements were made using a Peak Detector and an Average Detector
with a bandwidth of 1 MHz

When an emission is located, it is positively identified and its maximum level is found by
rotating the automated turntable, and by varying the antenna height with an automated antenna
tower.

All emissions were measured in both vertical and horizontal antenna polarisations.

The emission level is determined in field strength by taking the following into consideration:

Level (dBV/m) = Receiver Reading (dBV) + Antenna Factor (dB/m) + Coax Loss (dB) –
Amplifier Gain (dB)

The Class B limits have been applied.

The receiver was tested when a dummy load was attached to the antenna port and the receiver
was tuned to 380.00, 480.525 and 520.000 MHz.

The receiver has an intermediate frequency of +90.0 MHz.

The digital device was tested when an Ethernet cable was attached to the Ethernet port and the
receiver was operating when tuned to 520.000 MHz.




____________________________________________________________________________________________________________________________________________________________________________

Page 9 of 16                                                           Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Field strength of the receiver spurious emissions (Verification)

The receiver was tested when a dummy load was attached to the antenna port and an Ethernet
cable was attached to the Ethernet port.

Testing of the receiver was carried out when it was receiving on 380.00, 450.525 and 520
MHz.

The receiver has an intermediate frequency of +90.0 MHz

No specific receiver emissions were detected with emissions observed to have a margin to the
limit that exceeded 20 dB.

Result: Complies.
Measurement Uncertainty:  4.1 dB




____________________________________________________________________________________________________________________________________________________________________________

Page 10 of 16                                                          Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Digital device spurious emissions 30-2000 MHz (Certification)

The device was tested when a dummy load was attached to the antenna port and an Ethernet
cable was attached to the Ethernet port.

All other emissions observed had a margin to the limit that exceeded 20 dB.

Device was tested on an open area test site at a distance of 3 metres.

Below 1000 MHz a quasi-peak detector was used with a bandwidth of 120 kHz

Above 1000 MHz an average detector and a peak detector were used with a bandwidth of 1
MHz.

Frequency Vertical Horizontal Limit  Margin                                                                             Result                  Antenna
  (MHz)   (dBμV/m) (dBμV/m) (dBμV/m) (dB)
  30.000     24.2     25.1     40.0   14.9                                                                                 Pass               Horizontal
  31.000     24.5     24.9     40.0   15.1                                                                                 Pass               Horizontal
  32.000     24.0     24.4     40.0   15.6                                                                                 Pass               Horizontal
  33.000     21.0     24.1     40.0   15.9                                                                                 Pass               Horizontal
  35.000     26.3     23.6     40.0   13.7                                                                                 Pass                Vertical
  36.000     25.5     23.3     40.0   14.5                                                                                 Pass                Vertical
  39.000     28.3     22.5     40.0   11.7                                                                                 Pass                Vertical
  43.000     25.1     21.0     40.0   14.9                                                                                 Pass                Vertical
  56.000     28.5     18.8     40.0   11.5                                                                                 Pass                Vertical
  63.000     24.2      -       40.0   15.8                                                                                 Pass                Vertical
  76.000     22.0      -       40.0   18.0                                                                                 Pass                Vertical
  78.000     25.0      -       40.0   15.0                                                                                 Pass                Vertical
  82.000     22.7      -       40.0   17.3                                                                                 Pass                Vertical
 208.000     22.9     28.8     43.5   14.7                                                                                 Pass               Horizontal
 340.000     20.7     16.5     46.0   25.3                                                                                 Pass                Vertical
 396.000     20.0     16.5     46.0   26.0                                                                                 Pass                Vertical
 400.000     24.6     21.6     46.0   21.4                                                                                 Pass                Vertical
 402.000     21.0     19.0     46.0   25.0                                                                                 Pass                Vertical
 416.000     22.5     18.2     46.0   23.5                                                                                 Pass                Vertical
 420.000     35.1     22.5     46.0   10.9                                                                                 Pass                Vertical

Result: Complies.
Measurement Uncertainty:  4.1 dB




____________________________________________________________________________________________________________________________________________________________________________

Page 11 of 16                                                          Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


Section 15.111: Receiver spurious emissions at antenna terminals (Verification)

Testing was carried out at the antenna port.

The receiver has an intermediate frequency of +90.0 MHz

Testing was performed on receive channels 380.000, 480.525 and 520 MHz.

Frequency: 380.000 MHz
        Frequency                                                                      Level                                                         Limit
           (MHz)                                                                       (dBm)                                                         (dBm)
          470.000                                                                       -91.0                                                         -57.0
         1880.000                                                                       -92.5                                                         -47.0

Frequency: 450.525 MHz
                    Frequency                                                          Level                                                         Limit
                      (MHz)                                                            (dBm)                                                         (dBm)
                     540.525                                                            -97.3                                                         -57.0

Frequency: 520.000 MHz
                    Frequency                                                          Level                                                         Limit
                      (MHz)                                                            (dBm)                                                         (dBm)
                     610.000                                                            -95.2                                                         -57.0

No other emissions observed.

Limit:

In accordance with CFR 47 Part 15, section 15.111 the power of any emission at the antenna
terminal should not exceed 2 nW (–57.0 dBm).


Result: Complies
Measurement Uncertainty: 3.3 dB




____________________________________________________________________________________________________________________________________________________________________________

Page 12 of 16                                                          Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


7.         TEST EQUIPMENT USED
     Instrument                        Manufacturer       Model                                Serial No                Asset Ref              Cal Due                 Interval
   Aerial Controller                      EMCO             1090                                9112-1062                RFS 3710              Not applic                   -
     Aerial Mast                          EMCO            1070-1                               9203-1661                RFS 3708              Not applic                   -
  Biconical Antenna                     Schwarzbeck     BBA 9106                                   -                    RFS 3612              7 Feb 2015                1 year
    Horn Antenna                          EMCO             3115                                9511-4629                 E1526               4 June 2017                3 year
    Log Periodic                        Schwarzbeck    VUSLP 9111                              9111-228                   3785                7 Feb 2015                1 year
   Mains Network                           R&S           ESH2-Z5                              881362/032                  3628               23 Oct 2016                2 year
       Receiver                            R&S           ESHS 10                              828404/005                  3728               27 June 2015               2 year
       Receiver                            R&S           ESIB 40                                100171                   R-27-1              29 Jan 2015                1 year
  Spectrum Analyser                    Hewlett Packard   E7405A                               US39150142                  3771                7 July 2015               1 year
      Turntable                           EMCO          1080-1-2.1                             9109-1578                RFS 3709              Not applic                   -
     VHF Balun                          Schwarzbeck     VHA 9103                                   -                    RFS 3603              7 Feb 2015                1 year

At the time of testing all test equipment was within calibration.

8.            ACCREDITATIONS
Testing was carried out in accordance with EMC Technologies Ltd registration with the
Federal Communications Commission as a listed facility, registration number: 90838, which
was updated in June 2014.

All testing was carried out in accordance with the terms of EMC Technologies (NZ) Ltd
International Accreditation New Zealand (IANZ) Accreditation to NZS/ISO/IEC 17025.

All measurement equipment has been calibrated in accordance with the terms of the EMC
Technologies (NZ) Ltd International Accreditation New Zealand (IANZ) Accreditation to
NZS/ISO/IEC 17025.

International Accreditation New Zealand has Mutual Recognition Arrangements for testing
and calibration with various accreditation bodies in a number of economies. This includes
NATA (Australia), UKAS (UK), SANAS (South Africa), NVLAP (USA), A2LA (USA),
SWEDAC (Sweden). Further details can be supplied on request.




____________________________________________________________________________________________________________________________________________________________________________

Page 13 of 16                                                          Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


9.            PHOTOGRAPHS




____________________________________________________________________________________________________________________________________________________________________________

Page 14 of 16                                                          Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


                                                                  Radiated emissions setup




____________________________________________________________________________________________________________________________________________________________________________

Page 15 of 16                                                          Test Report No 141017.3                                                  23rd December 2014
                                                         This report may not be reproduced except in full.


____________________________________________________________________________________________________________________________________________________________________________

Page 16 of 16                                                          Test Report No 141017.3                                                  23rd December 2014