1905TW0106-U3 RF Exposure Report.pdf

FCC ID: 2AD8UAHFIH01

RF Exposure Info

Download: PDF
FCCID_4349451

                                     MRT Technology (Taiwan) Co., Ltd         Report No.: 1905TW0106-U3
                                     Phone: +886-3-3288388                    Report Version:        V01
                                     Web: www.mrt-cert.com                    Issue Date:     06-24-2019




            RF Exposure Evaluation Declaration


FCC ID:                        2AD8UAHFIH01

Applicant:                     Nokia Solutions and Networks, OY



Application Type:              Certification

Product:                       AirScale Indoor Radio ASiR-pRRH

Model No.:                     AHFIH

Brand Name:                    Nokia

Test Procedure(s):             KDB 447498 D01v06




Reviewed By:
                                 ( Paddy Chen )
Approved By:
                                   (Chenz Ker)




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standards through the
calibration of the equipment and evaluated measurement uncertainty herein.
The test report shall not be reproduced except in full without the written approval of MRT Technology (Taiwan)
Co., Ltd.
FCC ID: 2AD8UAHFIH01                                                                       Page Number: 1 of 7


                                                       Report No.: 1905TW0106-U3


                                 Revision History

   Report No.          Version        Description      Issue Date       Note

 1905TW0106-U3         Rev. 01        Initial Report   06-24-2019       Valid




FCC ID: 2AD8UAHFIH01                                           Page Number: 2 of 7


                                                                       Report No.: 1905TW0106-U3



§2.1033 General Information
Applicant:                       Nokia Solutions and Networks, OY
Applicant Address:               2000 W. Lucent Lane, Naperville, Illinois, United States, 60563
Manufacturer:                    Nokia Solutions and Networks, OY
Manufacturer Address:            2000 W. Lucent Lane, Naperville, Illinois, United States, 60563
Test Site:                       MRT Technology (Taiwan) Co., Ltd
Test Site Address:               No. 38, Fuxing Second Rd., Guishan Dist., Taoyuan City 333,
                                 Taiwan (R.O.C)


Test Facility / Accreditations
Measurements were performed at MRT Laboratory located in Fuxing Rd., Taoyuan, Taiwan
( R.O.C )
MRT facility is a FCC registered (Reg. No. 153292) test facility with the site description
  report on file and is designated by the FCC as an Accredited Test Film.
 MRT facility is an IC registered (MRT Reg. No. 21723-1) test laboratory with the site
  description on file at Industry Canada.
 MRT Lab is accredited to ISO 17025 by the American Association for Laboratory
  Accreditation (TAF) under the American Association for Laboratory Accreditation
  Program (TAF Cert. No. 3261) in EMC, Telecommunications and Radio testing for FCC,
  Industry Taiwan, EU and TELEC Rules.




FCC ID: 2AD8UAHFIH01                                                             Page Number: 3 of 7


                                                               Report No.: 1905TW0106-U3



1.     PRODUCT INFORMATION
1.1. Equipment Description
Product Name:             AirScale Indoor Radio ASiR-pRRH
Model No.:                AHFIH
Brand Name:               Nokia
Test Device Serial No.:   NH191702680
Hardware Version:         X12
Software Version:         FL18A
LTE Specification
LTE Operating Band (s):   Band 2 / 66
Modulation Type:          QPSK, 16QAM, 64QAM, 256QAM
TX Frequency Range        Band 2: 1930 ~ 1990 MHz; Band 66: 2110 ~ 2200 MHz
RX Frequency Range        Band 2: 1850 ~ 1910 MHz; Band 66: 1710 ~ 1780 MHz
WCDMA Specification
WCDMA Operating Band (s): Band 2 / 66
Modulation Type:          QPSK, 16QAM
TX Frequency Range        Band 2: 1930 ~ 1990 MHz; Band 66: 2110 ~ 2200 MHz
RX Frequency Range        Band 2: 1850 ~ 1910 MHz; Band 66: 1710 ~ 1780 MHz



1.2. Antenna Information
      Band Support         Antenna Type             Model              Antenna Gain
      LTE Band 2,
                                                                          5.7dBi
     WCDMA Band 2
                          Omni-Directional       CMQ69273P
      LTE Band 66,
                                                                          5.7dBi
     WCDMA Band 66




FCC ID: 2AD8UAHFIH01                                                   Page Number: 4 of 7


                                                                          Report No.: 1905TW0106-U3



 2.     RF Exposure Evaluation
 2.1. Limits
According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b)


LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Frequency Range        Electric Field      Magnetic Field       Power Density        Average Time
                                                                             2
      (MHz)           Strength (V/m)       Strength (A/m)         (mW/cm )             (Minutes)
                           (A) Limits for Occupational/ Control Exposures
300-1500                     --                   --                 f/300                 6
1500-100,000                 --                   --                  5                    6
                     (B) Limits for General Population/ Uncontrolled Exposures
300-1500                     --                   --                f/1500                 6
1500-100,000                 --                   --                  1                    30
f= Frequency in MHz


Calculation Formula: Pd = (Pout*G)/(4*pi*r2)


Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
r = distance between observation point and center of the radiator in cm


Pd is the limit of MPE, 1mW/cm². If we know the maximum gain of the antenna and the total power
input to the antenna, through the calculation, we will know the distance r where the MPE limit is
reached.




FCC ID: 2AD8UAHFIH01                                                              Page Number: 5 of 7


                                                                Report No.: 1905TW0106-U3



2.2. Test Result of RF Exposure Evaluation
Product            AirScale Indoor Radio ASiR-pRRH
Test Item          RF Exposure Evaluation (For General Population)


     Test Mode         Frequency     Maximum       Safety        Power          Limit of Power
                          Band        EIRP     Distance (cm)    Density            Density
                                                                         2
                         (MHz)        (dBm)                    (mW/cm )           (mW/cm2)
    LTE Band 2         1930 ~ 1990    31.59          0.20        0.2869               1
    LTE Band 66        2110 ~ 2200    32.63          0.20        0.3645               1
  WCDMA Band 2         1930 ~ 1990    30.69          0.20        0.2332               1
  WCDMA Band 66        2110 ~ 2200    31.66          0.20        0.2916               1




Product            AirScale Indoor Radio ASiR-pRRH
Test Item          RF Exposure Evaluation (For Occupational)


     Test Mode         Frequency     Maximum       Safety        Power          Limit of Power
                          Band        EIRP     Distance (cm)    Density            Density
                         (MHz)        (dBm)                    (mW/cm2)           (mW/cm2)
    LTE Band 2         1930 ~ 1990    31.59          0.20        0.2869               5
    LTE Band 66        2110 ~ 2200    32.63          0.20        0.3645               5
  WCDMA Band 2         1930 ~ 1990    30.69          0.20        0.2332               5
  WCDMA Band 66        2110 ~ 2200    31.66          0.20        0.2916               5




FCC ID: 2AD8UAHFIH01                                                         Page Number: 6 of 7


                                                                       Report No.: 1905TW0106-U3



2.3. Summary of Test Result
The maximum calculations of above situations
      Model             Configuration          The formula of     Calculation      Limit    Result
                                           calculated the MPE    Power Density
                                                           2
                                                 (mW/cm )          (mW/cm2)
General Population    WCDMA Band 2             0.2869 + 0.3645      0.6514           1       Pass
   Occupational        & Band 66               0.2869 + 0.3645      0.6514           5       Pass


The wireless device described within this report has been shown to be capable of compliance with
basic restrictions related to human exposure to electromagnetic fields for both General public and
Occupational. The calculations shown in this report were made in accordance the procedures
specified in the applied test specifications
                                Required Compliance Boundary (cm)
               General Population                                   Occupational
                        20                                               20




                                                 The End
FCC ID: 2AD8UAHFIH01                                                             Page Number: 7 of 7



Document Created: 2019-07-09 20:54:55
Document Modified: 2019-07-09 20:54:55

© 2024 FCC.report