RF Test Report

FCC ID: 2AD5YWCCH3350

Test Report

Download: PDF
FCCID_4256977

                         Test Report No.: RF190312N016



                                                                 TEST REPORT
   Applicant                        Shenzhen Orderly Electronics Co., Ltd

                                    4F, Building7, Asian Industrial Park,Bantian Street, Longgang District, Shenzhen,
   Address
                                    China

   Manufacturer or
                                    Shenzhen Orderly Electronics Co., Ltd
   Supplier
                                    4F, Building7, Asian Industrial Park,Bantian Street, Longgang District, Shenzhen,
   Address
                                    China

   Product                          Fast Wireless Charging Windshield/Dash Mount

   Brand Name                       blackweb, CRAIG, MAGNAVOX

   Model                            BWA19AV906

   Additional Model &
                                    CCH3350, MCH3350, MMH3350, see items 3.1
   Model Difference

   Date of tests                    Mar. 12, 2019 ~ Apr. 15, 2019

   The submitted sample of the above equipment has been tested for according to the requirements of the
   following standards:

        FCC Part 15, Subpart C

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Ryan Lu                                                                Approved by Glyn He
                Project Engineer / EMC Department                                                      Supervisor / EMC Department




                                                                                                               Date: Apr. 17, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report
   sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the
   quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our
   report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is
   only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused
   by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue
   you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the
   tests conducted and the correctness of the report contents.



                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 28                                                                Report Version 1


                        Test Report No.: RF190312N016


                                               TABLE OF CONTENTS
    RELEASE CONTROL RECORD ............................................................................................................ 3

    1      SUMMARY OF TEST RESULTS ..................................................................................................... 4

    2      MEASUREMENT UNCERTAINTY .................................................................................................. 4

    3      GENERAL INFORMATION .............................................................................................................. 5
        3.1      GENERAL DESCRIPTION OF EUT ......................................................................................... 5
        3.2      DESCRIPTION OF TEST MODES ........................................................................................... 6
        3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 7
        3.4      DESCRIPTION OF SUPPORT UNITS ..................................................................................... 7
    4      EMISSION TEST.............................................................................................................................. 8
        4.1    CONDUCTED EMISSION MEASUREMENT ........................................................................... 8
          4.1.1   LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................. 8
          4.1.2   TEST INSTRUMENTS ....................................................................................................... 8
          4.1.3   TEST PROCEDURE .......................................................................................................... 9
          4.1.4   DEVIATION FROM TEST STANDARD ............................................................................. 9
          4.1.5   TEST SETUP ................................................................................................................... 10
          4.1.6   EUT OPERATING CONDITIONS .................................................................................... 10
          4.1.7   TEST RESULTS ...............................................................................................................11
        4.2    RADIATED EMISSION MEASUREMENT .............................................................................. 13
          4.2.1   LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 13
          4.2.2   TEST INSTRUMENTS ..................................................................................................... 14
          4.2.3   TEST PROCEDURE ........................................................................................................ 15
          4.2.4   DEVIATION FROM TEST STANDARD ........................................................................... 15
          4.2.5   TEST SETUP ................................................................................................................... 16
          4.2.6   EUT OPERATING CONDITIONS .................................................................................... 16
          4.2.7   TEST RESULTS .............................................................................................................. 17
        4.3. 20dB BANDWIDTH MEASUREMENT .................................................................................... 23
          4.3.1   LIMITS OF 20dB BANDWIDTH MEASUREMENT .......................................................... 23
          4.3.2   TEST INSTRUMENTS ..................................................................................................... 23
          4.3.3   TEST PROCEDURE ........................................................................................................ 24
          4.3.4   DEVIATION FROM TEST STANDARD ........................................................................... 24
          4.3.5   TEST SETUP ................................................................................................................... 24
          4.3.6   EUT OPERATING CONDITION ...................................................................................... 25
          4.3.7   TEST RESULTS .............................................................................................................. 25
    5      PHOTOGRAPHS OF THE TEST CONFIGURATION ................................................................... 27

    6      APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
           BY THE LAB .................................................................................................................................. 28




                                                   No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                       Page 2 of 28                                                              Report Version 1


                    Test Report No.: RF190312N016


                                    RELEASE CONTROL RECORD

     ISSUE NO.                  REASON FOR CHANGE                                                         DATE ISSUED

     RF190312N016               Original release                                                          Apr. 17, 2019




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 3 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


    1 SUMMARY OF TEST RESULTS

    The EUT has been tested according to the following specifications:


                               APPLIED STANDARD: FCC Part 15, Subpart C
      STANDARD
                              TEST TYPE AND LIMIT                    RESULT                     REMARK
       SECTION
         §15.203                Antenna Requirement                    PASS             Coil antenna is used.

         §15.207          AC Power Conducted Emission                  PASS        Meet the requirement of limit.

         §15.209                    Radiated Emission                  PASS        Meet the requirement of limit.

       §15.215 (c)                   20dB Bandwidth                    PASS        Meet the requirement of limit.




    2 MEASUREMENT UNCERTAINTY
    Where relevant, the following measurement uncertainty levels have been estimated for
    tests performed on the EUT as specified in CISPR 16-4-2:

                    MEASUREMENT                               FREQUENCY                           UNCERTAINTY
                  Conducted emissions                          9kHz~30MHz                                2.70dB
                                                             9KHz ~ 30MHz                                2.16dB
                   Radiated emissions
                                                            30MHz ~ 1GMHz                                4.04dB


    This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 4 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

  3        GENERAL INFORMATION
      3.1 GENERAL DESCRIPTION OF EUT
      PRODUCT                             Fast Wireless Charging Windshield/Dash Mount
      MODEL NO.                           BWA19AV906
      ADDITIONAL MODELS                   CCH3350, MCH3350, MMH3350
      FCC ID                              2AD5YWCCH3350
      POWER SUPPLY                        Input: DC 5V or 9V
      MODULATION TYPE                     FSK
      OPERATING FREQUENCY                 110KHz ~ 205KHz
      ANTENNA TYPE                        Coil Antenna
      CABLE SUPPLIED                      Unshielded, Detachabel 1.0m

      NOTES:
      1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's
         manual.
      2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
         test report.
      3. Please refer to the EUT photo document (Reference No.: 190312N016) for detailed product photo.
      4.   Additional models CCH3350, MCH3350, MMH3350 are identical with the test model BWA19AV906
           except the model number and trade name for marketing purpose.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


  3.2    DESCRIPTION OF TEST MODES

    The EUT was tested under the following modes the final worst mode was marked in
    boldface and recorded in this report.

      CONDUCTED EMISSION TEST:
                TEST FREQUENCY                                           TEST MODE
                        145KHz                                       DC 5V input charging
                        145KHz                                      DC 9V input charging
                        113KHz                                       DC 5V input Standby
                        113KHz                                       DC 9V input Standby


    RADIATED EMISSION TEST (BELOW 1GHZ):
                TEST FREQUENCY                                           TEST MODE
                        145KHz                                      DC 5V input charging
                        145KHz                                       DC 9V input charging
                        113KHz                                       DC 5V input Standby
                        113KHz                                       DC 9V input Standby
    20dB BANDWIDTH TEST:
                TEST FREQUENCY                                           TEST MODE
                        145KHz                                      DC 5V input charging
                        113KHz                                      DC 5V input Standby




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 6 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

    3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS
    The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
    requirements of the following standards:


    FCC Part 15, Subpart C
    ANSI C63.10-2013

    All test items have been performed and recorded as per the above standards.

  3.4       DESCRIPTION OF SUPPORT UNITS

    The EUT has been tested as an independent unit together with other necessary
    accessories or support units. The following support units or accessories were used to form
    a representative test configuration during the tests.

     NO.   PRODUCT            BRAND            MODEL NO.                        SERIAL NO.                   FCC ID
      1      Adapter        SAMSUNG            EP-TA20JBS                              N/A                      N/A
      2      Adapter           APPLE              A1299                                N/A                      N/A
      3   Mobile Phone      SAMSUNG            SM-G950FD                               N/A                      N/A
    Remarks: worst case mode test result shown on the report.

     NO.                            DESCRIPTION OF THE ABOVE SUPPORT UNITS
        1   N/A
        2   N/A
      3 N/A
    Remarks: worst-case test result shown on the report only.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 7 of 28                                                     Report Version 1


                    Test Report No.: RF190312N016

    4     EMISSION TEST
    4.1 CONDUCTED EMISSION MEASUREMENT
    4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT


                                          Class A (dBuV)                          Class B (dBuV)
          FREQUENCY (MHz)
                                       Quasi-peak   Average                   Quasi-peak Average
                 0.15 - 0.5               79          66                        66 - 56     56 - 46
                 0.50 - 5.0               73          60                          56          46
                 5.0 - 30.0               73          60                          60          50

        NOTES: (1) The lower limit shall apply at the transition frequencies.
               (2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50
                   MHz.
               (3) All emanations from a class A/B digital device or system, including any network of
                      conductors and apparatus connected thereto, shall not exceed the level of field strengths
                      specified above.


    4.1.2 TEST INSTRUMENTS
                    Equipment          Manufacturer Model No. Serial No.                    Last Cal.         Next Cal.
           EMI Test Receiver          Rohde&Schwarz ESR7     101494                        Mar. 12,19        Mar. 11,20
           Artificial Mains Network   Rohde&Schwarz ENV216   101173                        Mar. 12,19        Mar. 11,20
           Artificial Mains Network   Rohde&Schwarz ESH3-Z5 100317                         Mar. 13,19        Mar. 12,20
                                                             TK
           Voltage probe              SCHWARZBECK TK 9421                                  Jan. 17,19        Jan. 16,20
                                                             9421-176
                                                    ADT_Cond
           Test software              ADT                    N/A                           N/A               N/A
                                                    _V7.3.7


        NOTES: 1. The calibration interval of the above test instruments is 12 months and the
                 calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
              2. The test was performed in shielding room 553.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 8 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

    4.1.3 TEST PROCEDURE

    a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with
       EUT being connected to the power mains through a line impedance stabilization
       network (LISN). Other support units were connected to the power mains through
       another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling impedance for the
       measuring instrument.

    b. Both lines of the power mains connected to the EUT were checked for maximum
       conducted interference.

    c. The frequency range from 150 kHz to 30 MHz was searched. Emission levels under
       (Limit – 20dB) were not recorded.

     NOTES:

     1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
     2. "-": The Quasi-peak reading value also meets average limit and
        measurement with the average detector is unnecessary.
     3. Margin value = Emission level - Limit value
     4. Correction factor = Insertion loss + Cable loss
     5. Emission Level = Correction Factor + Reading Value



    4.1.4 DEVIATION FROM TEST STANDARD

    No deviation.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 9 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

    4.1.5 TEST SETUP

                            V e r t ic a l G r o u n d
                            R e f e r e n c e P la n e                                              T e s t R e c e iv e r


                            EUT
          40cm




                                                             80cm

           L IS N



                                                                               H o r iz o n t a l G r o u n d
                                                                               R e f e r e n c e P la n e

        N o t e : 1 . S u p p o r t u n it s w e r e c o n n e c t e d t o s e c o n d L I S N .
                 2 .B o t h o f L I S N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t le a s t 8 0 c m
                    f r o m o t h e r u n it s a n d o t h e r m e t a l p la n e s s u p p o r t u n it s .


    4.1.6 EUT OPERATING CONDITIONS
            a. Turned on the power of all equipment.
            b. EUT was operated according to the type description in manufacturer’s
                specifications or the User's Manual.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 10 of 28                                                     Report Version 1


                    Test Report No.: RF190312N016

    4.1.7 TEST RESULTS

       TEST MODE                DC 9V input Charging             6DB BANDWIDTH 9 kHz
                                DC 9V from adapter input AC
       TEST VOLTAGE                                         PHASE                             Line (L)
                                120V 60Hz
       ENVIRONMENTAL
                                25deg. C, 52% RH                 TESTED BY                    Dragon
       CONDITIONS

                                                           Emission
                Freq.        Corr.   Reading Value                                    Limit               Margin
                                                             Level
       No.                  Factor      [dB (uV)]          [dB (uV)]           [dB (uV)]                   (dB)
                [MHz]        (dB)      Q.P.    AV.        Q.P.    AV.         Q.P.    AV.             Q.P.      AV.
         1     0.15000       9.94     27.04   1.04       36.98 10.98         66.00 56.00             -29.02 -45.02
         2     0.65175      10.12     24.58   2.21       34.70 12.33         56.00 46.00             -21.30 -33.67
         3     1.60048      10.26     21.32 -6.57        31.58   3.69        56.00 46.00             -24.42 -42.31
         4     3.34725       9.71     15.64 -3.49        25.35   6.22        56.00 46.00             -30.65 -39.78
         5     5.09325      10.17     14.27   3.98       24.44 14.15         60.00 50.00             -35.56 -35.85
         6    16.59300       9.91     21.81 13.63        31.72 23.54         60.00 50.00             -28.28 -26.46

         REMARKS:        The emission levels of other frequencies were very low against the limit.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 11 of 28                                                      Report Version 1


                    Test Report No.: RF190312N016




       TEST MODE                DC 9V input Charging              6DB BANDWIDTH 9 kHz
                                DC 9V from adapter input
       TEST VOLTAGE                                               PHASE                        Neutral (N)
                                AC 120V 60Hz
       ENVIRONMENTAL
                                25deg. C, 52% RH                  TESTED BY                    Dragon
       CONDITIONS

                                                            Emission
                Freq.        Corr.    Reading Value                                    Limit                Margin
                                                              Level
       No.                  Factor      [dB (uV)]           [dB (uV)]           [dB (uV)]                   (dB)
                [MHz]        (dB)      Q.P.    AV.         Q.P.    AV.         Q.P.    AV.             Q.P.      AV.
         1     0.15632       9.86     42.01 24.40         51.87 34.26         65.66 55.66             -13.78 -21.39
         2     0.18756      10.00     38.89 20.75         48.89 30.75         64.14 54.14             -15.26 -23.40
         3     0.21976       9.77     36.24 16.16         46.01 25.93         62.83 52.83             -16.82 -26.90
         4     0.25144       9.79     33.28 13.59         43.07 23.38         61.71 51.71             -18.64 -28.33
         5     0.44007       10.11    22.48 12.77         32.59 22.88         57.06 47.06             -24.47 -24.18
         6     0.63019       9.87     24.89 17.32         34.76 27.19         56.00 46.00             -21.24 -18.81

       REMARKS:         The emission levels of other frequencies were very low against the limit.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 12 of 28                                                      Report Version 1


                    Test Report No.: RF190312N016

    4.2 RADIATED EMISSION MEASUREMENT
    4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

      TEST STANDARD: FCC Part 15, Subpart C, Section 15.209

    Emissions radiated outside of the specified bands, shall be according to the general
    radiated limits as following:

                   FREQUENCIES                  FIELD STRENGTH                   MEASUREMENT DISTANCE
                      (MHz)                     (microvolts/meter)                     (meters)
                   0.009 – 0.490                   2400/F(kHz)                                   300
                   0.490 – 1.705                  24000/F(kHz)                                    30
                    1.705 – 30.0                       30                                         30
                       30 – 88                        100                                         3
                      88 – 216                        150                                         3
                     216 - 960                        200                                         3
                     Above 960                        500                                         3
           NOTES:
         1. The lower limit shall apply at the transition frequencies.
         2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
         3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average
             detector, however, the peak field strength of any emission shall not exceed the maximum permitted
             average limits, specified above by more than 20dB under any condition of modulation.
         4. The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of
            field strength varies as the inverse distance square (40dB per decade of distance)
             Example:
             13.56MHz = 15848uV/m                       30m
                          = 84dBuV/m                    30m
                          = 84+20log(30/3)2             3m
                         =   124dBuV/m




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 13 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

    4.2.2 TEST INSTRUMENTS
         FREQUENCY 9KHz-30MHz
          Equipment         Manufacturer                 Model No.          Serial No.      Last Cal.          Next Cal.
          EMI Test Receiver Rohde&Schwarz                ESR7               101564          Mar. 12,19         Mar. 11,20
          Active Loop
                            SCHWARZBECK                  FMZB 1519B         1519B-045 May 04,18                May 03,19
          Antenna
          Amplifier         Burgeon                      BPA-530      100210                Apr. 18,18         Apr. 18,19
                                                         ADT_Radiated
          Test Software             ADT                               N/A                   N/A                N/A
                                                         _V8.7.07
         NOTES: 1. The test was performed in 10m Chamber.
                2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                 traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                   3. The FCC Site Registration No. is 749762.


         FREQUENCY 30MHz-1GHz
         Equipment         Manufacturer                  Model No.          Serial No.            Last Cal.         Next Cal.
         EMI Test Receiver Rohde&Schwarz                 ESU26              100005                Aug. 24,18        Aug. 23,19
         EMI Test Receiver Rohde&Schwarz                 ESCI               101418                Mar. 12,19        Mar. 11,20
         Trilog-Broadband
                           SCHWARZBECK                   VULB 9168          9168-555              Nov. 10, 18 Nov. 09, 19
         Antenna
         Trilog-Broadband
                           SCHWARZBECK                   VULB 9168          9168-554              Dec. 10, 18 Dec. 09, 19
         Antenna
         Preamplifier      EMCI                          EMC1135            980378                Mar. 15,19        Mar. 14,20
         Preamplifier      EMCI                          EMC1135            980423                Mar. 15,19        Mar. 14,20
         10m Semi-anechoic                               21.4m*12.1m*
                           CHANGLING                                        NSEMC006              Feb. 10,18        Feb. 09,20
         Chamber                                         8.8m
                                                         ADT_Radiated
          Test Software             ADT                                     N/A                   N/A               N/A
                                                         _V8.7.07
         NOTES: 1. The test was performed in 10m Chamber.
                2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                   traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                3. The FCC Site Registration No. is 749762.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 14 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

    4.2.3 TEST PROCEDURE

    < Below 30MHz >
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 10 meters Semi-anechoic chamber room. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The height of antenna is varied from one meter to four meters above the ground to
         determine the maximum value of the field strength. Both horizontal and vertical
         polarizations of the antenna are set to make the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to quasi-peak detect function and specified
         bandwidth with maximum hold mode when the test frequency is below 1 GHz.
      f. For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT
         and rotated about its vertical axis for maximum response at each azimuth about the
         EUT. And the centre of the loop shall be 1m above the ground.
    <30MHz~1GHz >
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 10 meters semi-anechoic chamber. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 10 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The antenna is a broadband antenna, and its height is varied from one meter to
         four meters above the ground to determine the maximum value of the field
         strength. Both horizontal and vertical polarizations of the antenna are set to make
         the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to Peak Detect Function and Specified
         Bandwidth with Maximum Hold Mode.

      NOTES:
      1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP) at
         frequency below 1GHz.
      2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
      3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
      4. Margin value = Emission level – Limit value.

    4.2.4 DEVIATION FROM TEST STANDARD

    No deviation.
                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 15 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


    4.2.5 TEST SETUP

    Below 30MHz test setup




    Below 1GHz test setup
                                                                       Ant. Tower
                                                                                                    1-4m
                                                       10m
                               EUT

                                                Turn Table

                        0.8m


                                                     Ground Plane

                                                    Spectrum




    Note: For the actual test configuration, please refer to the attached file (Test Setup Photo).




    4.2.6 EUT OPERATING CONDITIONS
         a. Turn on the power supply of the EUT.
         b. EUT was operated according to the type description in
            manufacturer’s specifications or the User's Manual.


                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 16 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016

    4.2.7 TEST RESULTS


                                                                   FREQUENCY
        TEST MODE                   DC 5V input Charging                                      9 -150KHz
                                                                   RANGE
                                                                   DETECTOR
                                    DC 5V from adapter input       FUNCTION &
        TEST VOLTAGE                                                                          Quasi-Peak, 200Hz
                                    AC 120V 60Hz                   RESOLUTION
                                                                   BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 54% RH               TESTED BY: Vincent
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: PARALLEL AT 3M
                       Correction  Raw   Emission                  Antenna                                    Table
       No     Freq.                                  Limit  Margin
                         Factor    Value   Level                    Height                                   Angle
        .    (MHz)                                (dBuV/m)   (dB)
                         (dB/m)   (dBuV) (dBuV/m)                    (cm)                                   (Degree)
        1   0.03520      -11.08    52.78   41.70    116.67  -74.97    100                                       35
        2   0.06050      -11.41    42.85   31.44    111.97  -80.53    100                                       72
        3   0.06480      -11.40    47.76   36.36    111.37  -75.01    100                                      122
        4   0.08420      -11.37    40.13   28.76    109.10  -80.34    100                                       72
        5   0.10010      -11.33    53.21   41.88    107.59  -65.71    100                                      127
        6   0.14610      -11.20    90.17   78.97    104.31  -25.34    100                                       36

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.009-0.15MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 17 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016




                                                                 FREQUENCY
        TEST MODE                   DC 5V input Charging                                    150KHz-30MHz
                                                                 RANGE
                                                                 DETECTOR
                                    DC 5V from adapter           FUNCTION &
        TEST VOLTAGE                                                                        Quasi-Peak, 200Hz
                                    input AC 120V 60Hz           RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 54% RH             TESTED BY: Vincent
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: PARALLEL AT 3M
                       Correction  Raw   Emission                  Antenna                                    Table
       No     Freq.                                  Limit  Margin
                         Factor    Value   Level                    Height                                   Angle
        .    (MHz)                                (dBuV/m)   (dB)
                         (dB/m)   (dBuV) (dBuV/m)                    (cm)                                   (Degree)
        1   0.15000      -11.19    81.66   70.47    104.08  -33.61    100                                      325
        2   0.43810      -11.28    65.76   54.48     94.77  -40.29    100                                      172
        3   0.73060      -10.86    56.57   45.71    70.65   -24.94    100                                       73
        4   1.02170      -10.92    50.98   40.06    68.01   -27.95    100                                      128
        5   1.60680      -10.95    43.23   32.28    64.44   -32.16    100                                      267
        6   1.89930      -10.96    41.02   30.06    69.54   -39.48    100                                      207

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.15-30MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 18 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016




                                                                 FREQUENCY
        TEST MODE                   DC 5V input Charging                                    9 -150KHz
                                                                 RANGE
                                                                 DETECTOR
                                    DC 5V from adapter           FUNCTION &
        TEST VOLTAGE                                                                        Quasi-Peak, 200Hz
                                    input AC 120V 60Hz           RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 54% RH             TESTED BY: Ming Bai
        CONDITIONS

                    ANTENNA POLARITY & TEST DISTANCE: PERPENDICYLARL AT 3M
                     Correction  Raw    Emission                  Antenna                                        Table
       No     Freq.                                 Limit  Margin
                      Factor     Value    Level                    Height                                        Angle
        .    (MHz)                               (dBuV/m)   (dB)
                      (dB/m)    (dBuV)  (dBuV/m)                    (cm)                                       (Degree)
        1   0.03520   -11.08     52.94    41.86    116.67  -74.81    100                                          325
        2   0.05590   -11.42     46.35    34.93    112.65  -77.72    100                                           42
        3   0.06430   -11.40     45.37    33.97    111.44  -77.47    100                                           38
        4   0.08290   -11.38     42.79    31.41    109.23  -77.82    100                                           63
        5   0.10030   -11.33     58.43    47.10    107.58  -60.48    100                                           95
        6   0.14610   -11.20     95.77    84.57    104.31  -19.74    100                                          125

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.009-0.15MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 19 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016




                                                                 FREQUENCY
        TEST MODE                   DC 5V input Charging                                    150KHz-30MHz
                                                                 RANGE
                                                                 DETECTOR
                                    DC 5V from adapter           FUNCTION &
        TEST VOLTAGE                                                                        Quasi-Peak, 200Hz
                                    input AC 120V 60Hz           RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 54% RH             TESTED BY: Vincent
        CONDITIONS

                     ANTENNA POLARITY & TEST DISTANCE: PERPENDICYLARL AT 3M
                       Correction  Raw    Emission                 Antenna                                       Table
       No      Freq.                                 Limit  Margin
                         Factor    Value    Level                   Height                                       Angle
        .     (MHz)                                (dBuV/m)  (dB)
                         (dB/m)   (dBuV)  (dBuV/m)                   (cm)                                      (Degree)
        1    0.15000     -11.19    86.62    75.43   104.08  -28.65    100                                         325
        2    0.27980     -11.14    77.74    66.60    98.67  -32.07    100                                          25
        3    0.40960     -11.26    71.39    60.13    95.36  -35.23    100                                          72
        4    0.71240     -10.91    62.27    51.36    70.85  -19.49    100                                          35
        5    1.01520     -10.92    56.35    45.43    68.06  -22.63    100                                         135
        6    1.27480     -10.93    52.16    41.23    66.26  -25.03    100                                          83

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.15-30MHz
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 20 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016



                                                                    FREQUENCY
        TEST MODE                   DC 5V input Charging                                        30-1000MHz
                                                                    RANGE
                                                                    DETECTOR
                                    DC 5V from adapter input        FUNCTION &
        TEST VOLTAGE                                                                            Quasi-Peak, 120kHz
                                    AC 120V 60Hz                    RESOLUTION
                                                                    BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 55% RH                TESTED BY: Ming Bai
        CONDITIONS

                     ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 10M
                        Correction  Raw   Emission                 Antenna   Table
                 Freq.                               Limit  Margin
        No.              Factor     Value   Level                   Height  Angle
                (MHz)                              (dBuV/m) (dB)
                         (dB/m)    (dBuV) (dBuV/m)                   (cm)  (Degree)
         1      67.951        -19.46       38.04          18.58         30.00          -11.42         200             40
         2      94.141        -20.84       40.45          19.61         30.00          -10.39         400            225
         3     146.885        -17.39       39.30          21.91         30.00           -8.09         400             14
         4     213.936        -18.52       45.49          26.97         30.00           -3.03         400            286
         5     292.021        -15.51       39.15          23.64         37.00          -13.36         400            298
         6     347.190        -14.64       34.77          20.13         37.00          -16.87         400            324

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 21 of 28                                                     Report Version 1


                    Test Report No.: RF190312N016


                                                                    FREQUENCY
        TEST MODE                   DC 5V input Charging                                       30-1000MHz
                                                                    RANGE
                                                                    DETECTOR
                                    DC 5V from adapter input        FUNCTION &
        TEST VOLTAGE                                                                           Quasi-Peak, 120kHz
                                    AC 120V 60Hz                    RESOLUTION
                                                                    BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 55% RH                TESTED BY: Ming Bai
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 10M
                          Correction Raw    Emission                 Antenna                                      Table
                  Freq.                                Limit  Margin
        No.                Factor     Value   Level                   Height                                     Angle
                 (MHz)                               (dBuV/m) (dB)
                           (dB/m)    (dBuV) (dBuV/m)                   (cm)                                     (Degree)
         1      35.280        -17.83      43.33         25.50         30.00         -4.50          100               32
         2      70.890        -19.73      46.33         26.60         30.00         -3.40          100              325
         3      93.470        -20.96      48.46         27.50         30.00         -2.50          100               25
         4      170.170       -16.28      42.18         25.90         30.00         -4.10          100              224
         5      214.988       -18.47      45.04         26.57         30.00         -3.43          100              358
         6      289.828       -15.00      37.88         22.88         37.00        -14.12          100              351

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 22 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


    4.3. 20dB BANDWIDTH MEASUREMENT

    4.3.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT
    The field strength of any emissions appearing between the band edges and out of band
    shall be attenuated at least 20 dB below the level of the unmodulated carrier or to the
    general limits in Section 15.209.

    4.3.2 TEST INSTRUMENTS

    Equipment                   Manufacturer            Model No.         Serial No.          Last Cal.           Next Cal.
    Power Sensor                Keysight                U2021XA           MY55060016          Jun. 13,18          Jun. 12,19
    Power Sensor                Keysight                U2021XA           MY55060018          Jun. 13,18          Jun. 12,19
    Power Meter                 Anritsu                 ML2495A           1139001             Mar. 12,19          Mar. 11,20
    Power Sensor                Anritsu                 MA2411B           1531155             Mar. 12,19          Mar. 11,20
    Digital Multimeter          FLUKE                   15B               A1220010DG          Oct. 17, 18         Oct.16, 19
    Humid & Temp
                                Haida                   HD-2257           110807201           Nov.15,18           Nov. 14,19
    Programmable Tester
    Oscilloscope                Agilent                 DSO9254A          MY51260160          Nov. 09,18          Nov. 08,19
    Signal Analyzer             Rohde & Schwarz FSV7                      102331              Aug. 02,18          Aug. 01,19
    Signal Generator            Agilent                 N5183A            MY50140980          Dec. 07,18          Dec. 06,19
    Agile Signal Generator Agilent                      8645A             Agilent             Oct.27, 18          Oct.26, 19
    Spectrum Analyzer           Keysight                N9020A            MY55400499          Mar. 12,19          Mar. 11,20
    MXG-B RF Vector
                                Keysight                N5182B            MY56200288          Dec. 07, 18         Dec. 06, 19
    Signal Generator
    Attenuator                  MINI                    BW-S10W2+ S130129FGE2 N/A                                 N/A
    DC Source                   Keysight                E3642A            MY56146098          N/A                 N/A
    NOTES:
       1. The test was performed in RF Oven room.
      2. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
         CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 23 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


    4.3.3 TEST PROCEDURE
      a. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
          from an external generator.

      b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient
          frequency within its operating range. Set a reference level on the measuring instrument equal to the
          highest peak value.

      c. Measure the frequency difference of two frequencies that were attenuated 20dB from the reference level.
          Record the frequency difference as the emission bandwidth.

      d. Repeat above procedures until all frequencies measured were complete.




    4.3.4 DEVIATION FROM TEST STANDARD

    No deviation.



    4.3.5 TEST SETUP

                     EUT                                                SPECTRUM
                                                                        ANALYZER
                                             10dB ATTENUATION
                                             PAD




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 24 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016



    4.3.6 EUT OPERATING CONDITION


    a. Turn on the EUT.
    b. The EUT tested in charging mode and standby mode respectively.




    4.3.7 TEST RESULTS



                    TEST MODE                 CHANNEL FREQUENCY (KHz)                     20dB BANDWIDTH (Hz)

                 DC 5V input Standby                           113                                     820.5


                Lower & Upper Test Frequency Point                  Test Frequency
                                                                                                        P/F
                              (MHz)                                      (KHz)
                                    Lower                                113.3537                      PASS
                                    Upper                                114.1742                      PASS

    Test Data:




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 25 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016




                    TEST MODE                 CHANNEL FREQUENCY (KHz)                     20dB BANDWIDTH (Hz)

                DC 5V input Charging                           145                                    1.3198


                Lower & Upper Test Frequency Point                  Test Frequency
                                                                                                        P/F
                              (MHz)                                      (KHz)
                                    Lower                                145.2499                      PASS
                                    Upper                                146.5697                      PASS

    Test Data:




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 26 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


    5      PHOTOGRAPHS OF THE TEST CONFIGURATION


     Please refer to the attached file (Test Setup Photo).




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 27 of 28                                                    Report Version 1


                    Test Report No.: RF190312N016


   6 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
      CHANGES TO THE EUT BY THE LAB

    No any modifications were made to the EUT by the lab during the test.




    ---END---




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 28 of 28                                                    Report Version 1



Document Created: 2019-04-29 09:15:19
Document Modified: 2019-04-29 09:15:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC