Test Report

FCC ID: 2AD5KMWB300

Test Report

Download: PDF
FCCID_4349593

    KNJ
   EJ U tJP

 Report Number:             F690501/RF—RTLO13989—1                                            Page:     1      of      23




                              TEST REPORT
                                                           of

                            FCC Part 15 Subpart C §15.209, §15.231
                              IC RSS—210 Issue 9, RSS—Gen Issue 5

                                         FCC ID: 2AD5SKMWB300
                                  IC Certification: 22232—MWB300


Equipment Under Test                : SMARTKEY BAND
Model Name                          : MWB—300A7
Variant Model Name                  _: MWB—300A3
Applicant                           : PARTRON CO., LTD.
Manufacturer                        : PARTRON CO., LTD.

Date of Receipt                     : 2019.05.22
Date of Test(s)                     : 2019.05.27 ~2019.06.18
Date of Issue                       : 2019.07.04


In the configuration tested, the EUT complied with the standards specified above.




  Tested By:                                       —                 Date:                      2019.07.04

                                Jinhyoung Cho


   Technical
   m anager:7                 ~L n
                              /                                      Date:                      2019.07.04

                                 Jungmin Yang



The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807    hfto/www.sqsgroup.kr
RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 /Fax. +82 31 427 2370           A4(210 mm x 297 mm)


Report Number:           F690501/RF—RTLO13989—1                                            Page:       2       of        23




                                         TABLE OF CONTENTS

   1. G@NErAl INfOMMAtION ——————————————————<oonncnccmncnnnc enc en ncon nncnnn ce n ce n cce ce                    3

   2. Field Strength of Fundamental and Spurious EMISSIQM———————————————————————————                                7

   3. Bandwidth Of ODErAtiON FF@QU@MGy—————————————onnonn cceeeee>                                                  15

   4. OCCUPI@Q BAMUWiGtA————————————o———onnooneonnoennoonnonnnoenn en nonn on nnnnn en n cce                        17

   5. TYANSMISSION TIM@————————————onmononoonnoononnoonnonnnonnnonnnen onnnonnn en n cce ooo es                     19


   6. DUty CYCI@ GOFY@CtION FAGLON~———————————o—oonmoenoennoonnonnnnnnnn enc enc                                    21

   7. Antenna Requirement—                                                                                          23




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:                F690501/RF—RTLO13989—1                                        Page:       3       of      23


1. General Information

1.1. Testing Laboratory
SGS Korea Co., Ltd. (Gunpo Laboratory)
     — 10—2, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807
     — 4, LS—ro 182beon—gil. Gunpo—si, Gyeonggi—do, Korea, 15807
     — Designation number: KRO150
All SGS services are rendered in accordance with the applicable SGS conditions of service available on
request and accessible at http//www.sgs.com/en/Terms—and—Conditions.aspx.
Telephone            :         +82 31 688 0901
FAX                  :1        +82 31 688 0921

1.2. Details of Applicant
Applicant                 :    PARTRON CO., LTD.
Address                   :    22, Samsungi—ro 2—gil, Hwaseong—si, Gyeonggi—do, Korea
Contact Person            _:   Byun, Jae—beom
Phone No.                 :    482 31 201 7906

1.3. Details of Manufacturer
Company                   :    Same as applicant
Address                   :    Same as applicant

1.4. Description of EUT

Kind of Product                      SMARTKEY BAND

Model Name                           MWB—300A7

Variant Model Name                   MWB—300A3

Power Supply                         DC 3.7 V

Frequency Range                      Tx: 433.92 Ik, Rx: 125.00 i

Modulation Type                      FSK

Number of Channel                    1

Antenna Type                         PCB Antenna




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                                Page:        4       of      23


1.5. Test Equipment List

          i                                                                                                Cal.
       Equipment       Manufacturer                Model                     S/N           Cal. Date     Interval     Cal. Due


Signal Generator             R&S               SMBV100A                     255834       Jun. 10, 2019   Annual     Jun. 10, 2020

Spectrum Analyzer            R&S                  FSV3O                     103210       Dec. 05, 2018   Annual     Dec. 05, 2019

Spectrum Analyzer           Agilent               N3020A                 MY53421758      Sep. 21, 2018   Annual Sep. 21, 2019

       Preamplifier          H.P.                  8447F                 2944A03909      Aug. 07, 2018   Annual Aug. 07, 2019

       Preamplifier         Agilent                8449B                 3008A01982      Feb. 22, 2019   Annual     Feb. 22, 2020

 High Pass Filter       Mini—Circuits           NHP—800+                 V8207600724     Mar. 08, 2019   Annual     Mar. 08, 2020

   :
 High Pass Filter
                 :      Wainwright
                      Instrument GmbH
                                          WHKX10—200—1000—
                                             18000—403s                       7          Mar. 12, 2019   Annual     Mar. 12, 2020

                       Schwarzbeck                                                                        200.
  Loop Antenna        Mess—Elektronik          FMzZB 1519                  1519—039      Aug. 23, 2017   |Biennial] Aug. 23, 2019

    .                  Schwarzbeck                                                                         202
  Bilog Antenna       Mess—Elektronik           VULB3163                    01126        Mar. 26, 2018   |Biennial| Mar. 26, 2020

  Horn Antenna               R&S                   HF3O7                    100145       Jan. 31, 2019   |Biennial] Jan. 31, 2021

  Test Receiver              R&S                  ESU26                     100109       Jan. 31, 2019   Annual     Jan. 31, 2020

                       Innco systems         CONTROLLER                  ©O3000/963/3
       Controller          GmbH               C03000—4P                    8330516/L        N.C.R.         N/A         N.C.R.


       Turn Table      InncoGmbH
                             systems            Ds 1200 s                    N/A            N.CR.          N/A         N.CR.
                       Innco systems                                     MA4640/5367/3
 Antenna Master            GmbH              MA4G40—XP—ET                  83305 16/.       N.C.R.         N/A         N.C.R.


Anechoic" Chamber|     SY Corporation
                              POr@uON    [1g.6 m Lx x6.4Woxm Hx 6.6 m}       N/A            NCR            N/A         NCR

  Coaxial Cable         SUCOFLEX                 104 (3 m)                MY3258414      Jan. 04, 2019   ;ean;      Jul. 04, 2019

  Coaxial Cable         SUCOFLEX                104 (10 m)                MY3145814      Jan. 04, 2019   ;ean;      Jul. 04, 2019




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807         hitp:/worw.sascroup ks
RTT5041—19(2019.04.24)(1)                           Tel. +82 31 428 5700 / Fax. +82 31 427 2370            A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO13989—1                                                Page:      5       of      23


1.6. Summary of Test Results
The EUT has been tested according to the following specifications:

                Applied standard: FCC Part15 Subpart C, IC RSS—210 Issue 9, RSS—Gen Issue 5

    Section in FCC            Section in IC                             Test Item                             Result

                            RSS—210 Issue 9,                      Radiated emission,
        1223?%2;            F!SAS.jélibllsesfi; 5                Spurious Emission and                      Complied
          '                          89          ‘          Field Strength of Fundamental


        15.231(c)                     —                  Bandwidth of Operation Frequency                  Complied


        15.231(a)           HSS-2L01IS1$ue 9.                     Transmission Time                        Complied

                            RSS—210 Issue 9,
                                 A1.3                                  .        ;                                :
            —               RSS—Gen Issue 5,                     Occupied Bandwidth                        Complied
                                     6.7


         15.207             RSS—Gen Issue 5             AC Power Line Conducted Emission                      N/A"
                                     8.8


Note;

1) The AC power line test was not performed because the EUT does not operate while charging.

1.7. Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the apparatus:

                      Parameter                                                      Uncertainty (dB)

                  Occupied Bandwidth                                                     + 9.66 t

        Radiated Disturbance, 9 ki to 30 Ift                                             +3.59 dB

         Radiated Disturbance, below 1 6t                                                +5.88 dB

         Radiated Disturbance, above 1 6t                                                +5.94 dB

Uncertainty figures are valid to a confidence level of 95 %.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)     4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                            Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO13989—1                                            Page:           6       of      23


1.8. Test Report Revision

 Revision             Report Number                Date of Issue                          Description

     0           F690501/RF—RTLO13989                2019.06.24                                Initial

     1          F69050 1/RF—RTLO13989—1              2019.07.04                       Revised test report


1.9. Description of Variant Model

                                              Basic Model                                  Variant Model
                                              MWB—300A7                                     MWB—300A3
         Immolnterface                            3D                                             3D
         Transponder                 HT—2, HT—3, HT—AES, HT—Pro                    HT—2, HT—3, HT—AES, HT—Pro
            EROM                         16 KB / 24 KB / 32 KB                         16 KB /24 KB / 32 KB
           EEPROM                                 2048B                                         2048B
           Package                       HVQFN32, HVQFN40                                      HVQFN32
          LF cap tune                               No                                             No
           LF polling                               yes                                            No
   LF 3D Boost Mode                                 No                                             No
    (0.1mVpp, 14p A)
   Mechanical Motion
                                                    yes                                            No
       Sensor IF




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807       Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                            Page:          7     of      23


2. Field Strength of Fundamental and Spurious Emission
2.1. Test Setup

The diagram below shows the test setup that is utilized to make the measurements for emission below 30
Mz.


                                               Tumn Table



                                   EUT
                            fi                                 f                                            Coaxial
         Power Cable                                        0.8 m                               f€——Cable

                                              |
                                            E_ . ——3
                                                                                                     Ground Plane
                       Power

                                                                                       EMI Receiver


The diagram below shows the test setup that is utilized to make the measurements for emission from 30 M
to 1 (z.




                                               Turn Table



                                 _| EUT            l
                                                              T
                                                                                                       Coaxial
           Power Cable                                  0.8 m                                          Cable

                                                1
                                            o——<<mr_——]                                                T
                                                                                                Ground Plane
                         Power

                                                                                    EMI         er




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370          A4(210 mm x 297 mm)


 Report Number:           F69050 1/RF—RTLO13989—1                                                   Page:    8       of      23


The diagram below shows the test setup that is utilized to make the measurements for emission. The
spurious emissions were investigated form 1 (k to the 10harmonic of the highest fundamental frequency
or 40 (ik, whichever is lower.



                                                                                             Antenna Tower




                X heserp:i3 mosplessusses                                                  Horn Antenna
                                          v
                  L_             .                              i Te                     Spectrum

                                          :                     L
                            )    i                    —f               x                 Analyzer



                 Table
                                ||    I       |||           f                       §     ~—{Amplifier




 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)        4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807     hilp/www. sgsgroup.kr
RTT5041—19(2019.04.24)(1)                             Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                           Page:        9       of      23


2.2. Limit

2.2.1.FCC

2.2.1.1. Radiated Emission Limits; general requirements.

According to §15.209(a), except as provided elsewhere in this subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

             Frequency                             Field Strength                         Measurement Distance
                (Me)                             (microvolts/meter)                             (meter)

            0.009—0.490                               2 400/F(Ktt)                                   300
            0.490—1.705                              24 000/F (kih)                                   30
             1.705—30.0                                    30                                         30
               30—88                                     100**                                         3
              88—216                                     150**                                         3
              216—960                                    200**                                         3
             Above 960                                    500                                          3
** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
section shall not be located in the frequency bands 54—72 M, 76—88 Mé, 174—216 M or 470—806 Mt.
However, operation within these frequency bands is permitted under other sections of this part, e.g.,
§§15.231 and 15.241.

2.2.1.2. Periodic operation in the band 40.66—40.70 Mt and above 70 Mt

According to §15.231(b), in addition to the provisions of §15.205, the field strength of emissions from
intentional radiators operated under this section shall not exceed the following:


    Fundamental Frequency                 Field Strength of Fundamental                 Field StlE:‘gij;rs\igLspurious
             (Me)                                (microvolts/meter)                         (microvolts/meter)
            40.66—40.70                                  2,250                                       225
              70—130                                     1,250                                       125
              130—174                              1,250 to 3,750                               125 to 375
              174—260                                    3,750                                       375
              260—470                              ‘3,750 to 12,500                            ‘375 to 1,250
             Above 470                                  12,500                                       1,250
 ‘linear interpolations
Where F is the frequency in M, the formulas for calculating the maximum permitted fundamental field
strengths are as follows: for the band 130—174 Mk, aV/m at 3 meters = 56.81818(F) — 6136.3636; for the band
260—470 M4, w¥/m at 3 meters = 41.6667(F) — 7083.3333. The maximum permitted unwanted emission level
is 20 dB below the maximum permitted fundamentallevel.

mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370          A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                           Page:       10       of      23


2.2.2. IC

2.2.2.1. Transmitter Emission Limits

According to RSS—Gen Issue 5, 8.9.
Except where otherwise indicated in the applicable RSS, radiated emissions shall comply with the field
strength limits shown in table 5 and table 6. Additionally, the level of any transmitter unwanted emission shall
not exceed the level of the transmitter‘s fundamental emission.

                     Table 5 — General field strength limits at frequencies above 30 MZ


                 Frequency (Mt)                                     Field Strength (@¥/m at 3 m)

                         30—88                                                     100

                        88—216                                                     150

                        216—960                                                    200

                    Above 960                                                      500


                     Table 6 — General field strength limits at frequencies below 30 Mz


            Frequency             Magnetic Field Strength (H—Field) (aA/m)           Measurement Distance (m)

            9—490 ki‘                         6.37/F (F in ki                                        300

        490—1 705 ki                          63.7/F (F in kit)                                      30

         1.705—30 It                                 0.08                                            30


Note 1: The emission limits for the ranges 9—90 i and 110—490 ki are based on measurements
        employing a linear average detector.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807    Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                             Page:    11        of      23


2.2.2.2. Momentarily Operated Devices

According to A.1 of RSS—210 Issue 9.
The frequency bands and field strength limits in tables A1 and A2 of this annex are reserved exclusively for
the transmission of a control signal, such as that used with alarm systems, door openers, remote switches,
etc. Data may be sent with a control signal. Radio control of toys or model aireraft, as well as continuous
transmissions, such as voice or video, are not permitted, except as provided in Section A.1.4 below.

             Table A1 — Permissible Field Strength Limits for Momentarily Operated Devices


              Fundamental Frequency (Mk),                                        Field Strength of
         Excluding Restricted Frequency Bands                              the Fundamental Emissions
                    Specified in RSS—Gen                                             (wN¥/m at 3 m)

                              70—130                                                      1,250

                              130—174                                               1,250 to 3,750°

                         174—260%°°"                                                     3,750
                         260—470%°%°"                                              3,750 to 12,500*
                             Above 470                                                   12,500
     * Linear interpolation with frequency, f, in M:

     For 130—174. Mik: Frequency Strength (@¥/m) = (56.82 x 1) — 6136
     For 260—470 Mik: Frequency Strength (@¥/m) = (41.67 x ) — 7083


Note 1: Frequency bands 225—328.6 Ift and 395.4—399.9 M are designated for the exclusive use of the
        Government of Canada. Manufacturers should be aware of possible harmful interference and
        degradation of their licence—exempt radio equipmentin these frequency bands.




 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO13989—1                                            Page:     12        of      23


2.3. Test Procedures
Radiated emissions from the EUT were measured according to the dictates of ANSI €63.10—2013

2.3.1. Test Procedures for emission below 30 Mt
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter anechoic
   chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
b. Then antenna is a loop antenna is fixed at one meter above the ground to determine the maximum value
   of the field strength. Both parallel and perpendicular of the antenna are set to make the measurement.
c. For each suspected emission, the EUT was arranged to its worst case and then the table was turned from
   0 degrees to 360 degrees to find the maximum reading.
d. The test—receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold
  Mode.

2.3.2. Test Procedures for emission from 30 M to 1 000 M
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter anechoic
   chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
b. During performing radiated emission below 1 (, the EUT was set 3 meters away from the interference
   receiving antenna, which was mounted on the top of a variable—height antenna tower. During performing
   radiated emission above 1. (%, the EUT was set 3 meter away from the interference—receiving antenna.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
   ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
  the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the table was turned from 0 degrees to 360 degrees to find the
   maximum reading.

2.3.3. Test Procedures for emission above 1 (
a. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter anechoic
   chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 1 Ms for Peak
  detection at frequency above 1 (t.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                                                            Page:          13        of      23


2.4. Test Result

Ambient temperature                :i       (23 £ 1) °C
Relative humidity                  :    47        % R.H.

2.4.1. Field Strength of Fundamental

The following table shows the highest levels of radiated emissions on both polarizations of horizontal and
vertical.

 Frequency        Detect           Ant.            Reading                          AF                   CL           Result                Limit         Margin
    (MZ)          Mode             Pol.             {dBwW)                        {dB/m)                 (dB)        {dBaV/m)             (dBaV/m)         (dB)
      433.96       Peak                 V             48.22                       2218                   5.37          75.77              100.83          25.06

      433.96      Average               V             40.48                       22.18                  5.37          68.03               80.83          12.80

Remark;

 1.     To get a maximum emission level from the EUT, the EUT is manipulated through three orthogonal
        planes (X, Y, Z). Worst orthogonal plan of EUT is Y — axis.
        Definition of DUT for three orthogonal planes is described in the test setup photos.
 2.     3 m Limit (dBmV/m)    _= 20l0g[41.67(Fy) — 7083] = 80.83
 3.     Result                =         Reading + Antenna Factor + Cable Loss
 4.     Average Reading       =         Peak Reading + Duty Cycle Correction Factor
 5.     Duty Cycle Correction Factor: 20l0g(T,,, / 100 ms) = 20log(41.01 / 100) = —7.74
        — Ton =41.01 ms.
        — Tonsof = 100 ms (pulse train is 100 ms instead of 168 ms).

— Test plot


                              Ee                                                             auoviro       |eesizenowoo     [emeneranrt
                     Span 2.00000000 MHz                            .               #Avg Type: RMS
                                                              C27 Trig: FreeRun     AvalHiold:>100/100                      e
                                                 iGainstigh       #Atten: 0 dB


                             Eoc c




                     oo enc e                                                                              Span 2.000 MHz
                     Eoo GH                            uds ur                                Sweep 1.000 ms (1001 pts)
                     use



 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)           4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807                                 hittoy/www.sqsgroup.kr
RTT5041—19(2019.04.24)(1)                                       Tel. +82 31 428 5700 / Fax. +82 31 427 2370                                A4(210 mm x 297 mm)


 Report Number:              F690501/RF—RTLO13989—1                                              Page:    14        of          23


2.4.2. Spurious Emission

The following table shows the highest levels of radiated emissions.
The frequency spectrum from 9 ki to 4 400 Mk was investigated.

              Radiated Emissions               Ant.       Correction Factors               Total                  Limit
Frequency          Reading       Detect        Pol           AF        AMP + CL           Actual          Limit           Margin
       (We)         (dBav)         Mode              ‘     (dBim)          (dB)          (dBaNim)        (dBa¥im)          (dB)
      Above           Not           .            .            .              .               .               .              .
      0.009        detected

Remark;

 1.     To get a maximum emission level from the EUT, the EUT is manipulated through three orthogonal
        planes (X, Y, Z). Worst orthogonal plan of EUT is X — axis.
        Definition of DUT for three orthogonal planes is described in the test setup photos.
 2.     3 m Limit (dBa¥/m)      = 20l0g[(41.67(F) — 7083] — 20 dBa¥/m = 60.83 dBaV/m
 3.     Correction Factors      = AF + AMP + CL
 4.     Actual                  = Reading + AF + AMP + CL
 5.     Average Reading         = Peak Reading + Duty Cycle Correction Factor
 6.     Duty Cycle Correction   Factor: 20log(T,,, / 100 ms) = 20log(41.01 / 100) = —7.74
        ~Toa =41.01 ms.
        =Tomat =100 ms (pulse train is 100 ms instead of 168 ms).
 7..**" means the restricted band.
 8.     According to § 15.31(0), Emission levels are not reported much lower than the limits by over 20 dB.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807       Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                            Tel. +82 31 428 5700 / Fax. +82 31 427 2370          A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO13989—1                                            Page:     15        of      23


3. Bandwidth of Operation Frequency
3.1. Test Setup



                                                                       Spectrum
                                         EUT                           Analyzer



3.2. Limit

According to §15.231(c), the bandwidth of the emission shall be no wider than 0.25 % of the center
frequency for devices operating above 70 Mk and below 900 Mt. For devices operating above 900 M, the
emission shall be no wider than 0.5 % of the center frequency. Bandwidth is determined at the points 20 dB
down from the modulated carrier.

3.3. Test Procedure

1. The transmitter output is connected to the spectrum analyzer.
2. The resolution bandwidth (RBW) shall be in the range of 1 % to 5 % of the occupied bandwidth (OBW) and
 video bandwidth (VBW) shall be approximately 3 x RBW.
3. The bandwidth of fundamental frequency was measured and recorded.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:              F690501/RF—RTLO13989—1                                                                          Page:            16     of      23


3.4. Test Result

Ambient temperature                         (23 £ 1) C
Relative humidity                           47          % R.H.

                                          Bandwidth of                                        mans

          (e)
      Frequency
                                                       (i)
                                      Operation Frequency
                                                                                              )
                                                                                             Limit                                     Remark


        433.92                                      97.680                                 1 084.80                   The point 20 dB downl from the
                                                                                                                                 modulated carrier

— Test plot

                    Spectrum                                                                                                             =>
                                                                                                                                          y
                     Ref Level —20.00 dam                      e Rew 3inz
                     aue              o as          SWT 5.6 ms @ VBW 10 iz        Mode Sweei
                    Come
                                                                                           malx]                                ~16.97 dbm
                                                                                                                            490.079000 mel
                    —40dam                                                                 mitil                                —68.02 deml
                                                                                                                            499.004200 miel
                    —50 dam
                    —60 dam
                                    1 —60.070 dn
                    70 dam
                    —20 dam
                    —20 dam
                    —100 dn
                    +110 dn
                    —120 dom

                    or fesse une                                             so1 pts                                        Span 500.0 kiie
                    Marker
                     Type | Ret | Te |             Xcvalue          |   Y—value       |__Eunction                  Function Result
                       m            3              «33.escce ie         ~6a.02 dam
                       nel     i)       i               97.00 inz           0.c0 as
                       ms               f          «2Geraceie           ~6.97 com
                                                                                                    Neasuring...




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)                4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807                           hitptwurm.sqsqgroup.la
RTTS041—19(2019.04.24)(1)                                           Tel. +82 31 428 5700 / Fax. +82 31 427 2370                               A4(210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO13989—1                                            Page:     17        of      23


4. Occupied Bandwidth
4.1. Test Setup



                                                                       Spectrum
                                         EUT                           Analyzer



4.2. Limit

According to A.1.3 of RSS—210 Issue 9, the 99 % bandwidth of momentarily operated devices shall be less or
equal to 0.25 % of the centre frequency for devices operating between 70 Mz and 900 i. For devices
operating above 900 ift, the 99 % bandwidth shall be less or equal to 0.5 % of the centre frequency.

4.3. Test Procedure

1. The transmitter output is connected to the spectrum analyzer.
2. The resolution bandwidth (RBW) shall be in the range of 1 % to 5 % of the occupied bandwidth (OBW) and
 video bandwidth (VBW) shall be approximately 3 x RBW.
3. The bandwidth of fundamental frequency was measured and recorded.




mmz
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:            F69050 1/RF—RTLO13989—1                                                          Page:            18     of      23


4.4. Test Result

Ambient temperature                     (23 4 1) C
Relative humidity                       47      % RH.


      Frequency                   Occupied Bandwidth                               Limit
                                                                                                                      Remark
          (Me)                                  (i2)                               (t)

        433.92                                95.514                          1 084.80                  99 % Occupied bandwidth


— Test plot

                     Spectrum       ]                                                                                 [@]
                      Ref Level —30.00 dim               ® Rew  5 iz
                    l att              0 d_   SWT 5.5 ms @ VBW 10 kiz   mMade Sweep
                    Comen
                                                                               mibl                            ~16.99 db
                                                                                                          499,78600 Ne
                     —40 dom                                                   oce Bw                   95.5 19740101 kite

                     —50 dam

                                                                             J\
                                                                               &
                     —60 dom

                     70 dem

                     —20 dam

                     —20 dem

                     —100 dom

                     110 dam

                     +120 dom

                     or 109.92 ue                                  so1 pts                                Span 5oo.0 iz
                    1 JP                                                              Weasurings.   O
                                                                                                             Wt         /




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)         4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807                  hitpyhyww.sqsgroup.hr
RTT5041—19(2019.04.24}(1)                                Tel. +82 31 428 5700 /Fax. 182 31 427 2370                          A4{210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                            Page:     19        of      23


5. Transmission Time

5.1. Test Setup



                                                                        Spectrum
                                         EUT
                                                                        Analyzer



5.2. Limit

5.2.1. FCC

According to §15.231(a)(1), a manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.

5.2.2. IC

According to A1.1 (a) of RSS—210 Issue 9, a manually operated transmitter shall be equipped with a
push—to—operate switch and be under manual control at all times during transmission. When released, the
transmitter shall cease transmission within no more than 5 seconds of being released.


5.3. Test Procedure

1. The transmitter output is connected to the spectrum analyzer.
2. The bandwidth of the fundamental frequency was measured with the spectrum analyzer using RBW = 1. If%,
  VBW = 1 Mt, Span =0 Hz, Sweep Time =10 sec.
3. The bandwidth of fundamental frequency was measured and recorded.




mmz
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:            F690501/RF—RTLO13989—1                                                   Page:   20       of      23


5.4. Test Result

Ambient temperature                 (23 4 1) C
Relative humidity                   47       % RH.


        Frequency                   Transmission Time                              Limit
           (Mh)                           (sec)                                    (sec)                         Remark


          433.92                               0.39                       Same or less than 5                     Pass


— Test plot

                    Spectrum
                      Ref Level —5.00 dom            e rew 1 me
                      ae             10 ds e swr 10s o vaw 1 ncz
                     En
                     Tok ciw
                    10

                    «2o

                    o

                    so

                    so

                    «o



                    «o

                    —so

                    —100
                    or 109.92 ue




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)      4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807       Aftp:/www.sqsgroup.kr
RTT5041—19(2019.04.24(1)                               Tel. +82 31 428 5700 /Fax. 182 31 427 2370           A4{210 mm x 297 mm)


 Report Number:          F690501/RF—RTLO13989—1                                            Page:     21        of      23


6. Duty Cycle Correction Factor
6.1. Test Setup



                                                                     Spectrum
                                         EUT
                                                                     Analyzer



6.2. Limit

None (No dedicated Limit specified in the Rules)


6.3. Test Procedure

1. The transmitter output is connected to the spectrum analyzer.
2. Set center frequency of spectrum analyzer = operating frequency.
3. Set the spectrum analyzer as RBW = 1 Ift, VBW = Auto, Span = 0 Hz, Sweep Time = 0.5 sec.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)


 Report Number:                 F690501/RF—RTLO13989—1                                                                 Page:             22        of      23


6.4. Test Result

Ambient temperature                 :10       (23 + 1) C
Relative humidity                   :0        47      % RH.

CALCULATION:

Average Reading = Peak Reading (dBaV/m) + 20log (Duty Cycle)

In order to determine possible Maximum Modulation percentage, alternations are made to the EUT.
We measured;

         Tanott                                     T on                       M %= (Ton / Tomot) * 100 %                      Duty Correction Factor

        100 ms                                 41.01 ms                                        41.01                                       —7.74 dB

Tonow = 100 ms
Ton =41.01    ms
Duty Cycle = 20l0g(Ton / Tonm:ar) = 20l0g(0.4101) = —7.74. dB

Remark;

= Ton =41.01 ms.
= Tomot = 100 ms (pulse train is 100 ms instead of 168 ms).

— Test plot

                     Spectrum
                     Ref Level ~10.00 dom                         e rew 1 mz
                     w                    10 do @ SWT 500 ms @ VBw 1 iie
                     Trevio
                    e 16. Cw

                     —20 dam
                     —30 dam
                                o —10.000 «s




                     2
                     —20 dam
                     —20 dam
                     —100 dem

                     CF 430.99 mz                                          691      pts                                       50.0 ms/
                    Marker
                     Type | Ref | Tre |            X—value   |        Y—value     |_Eunction    _|          Function Result
                       m             1                 Ecvom           —2i.48 dam
                         be|    i         $           41.014 ms          —0.20 d8
                         o3     i         t          167.820 ms          —1.21 08

                                                                                          Wait for triover... OM




 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)               4, LS—ro 182beon—gil, Gunpo—si, Gyeong gi—do, Korea, 15807                          Affp:/inww.sqegroup.kr
RTT5041—19(2019.04.24)(1)                                         Tel. +82 31 428 5700 / Fax. 182 31 427 2370                            A4(210 mm x 297 mm)


 Report Number:           F690501/RF—RTLO13989—1                                            Page:     23        of      23


7. Antenna Requirement
7.1. Standard Applicable

For intentional device, according to FCC 47 CFR Section §15.203, an intentional radiator shall be designed
to ensure that no antenna other than that furnished by the responsible party shall be used with the device.

7.2. Antenna Connected Construction

Antenna used in this product is PCB Antenna with gain of —11.48 dBi.




                                           — End of the Test Report —
 The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
 the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
 withoutprior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)    4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807   Affp:s/fivwwsasoroup kr

 RTT5041—19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mm x 297 mm)



Document Created: 2019-07-09 20:57:24
Document Modified: 2019-07-09 20:57:24

© 2024 FCC.report