Test Report

FCC ID: 2ACYT-BNL15X7

Test Report

Download: PDF
FCCID_2803695

                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch

No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Nanshan
District Shenzhen, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                     Report No.: SZEM150700425801
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                Page:        1 of 21
Email:                ee.shenzhen@sgs.com



                                                                   TEST REPORT
Application No.:           SZEM1507004258CR
Applicant:                 SHENZHEN Hitevision Technology Co., Ltd.
Address of Applicant:      No. 8, Qinglan 1st Road, Pingshan, Shenzhen, Guangdong 518118, P. R. China.
Manufacturer:              Newline Interactive Inc.
Address of Manufacturer:   101 East Park Blvd. Suite 807 Plano, TX 75074, USA
Factory:                   SHENZHEN Hitevision Technology Co., Ltd.
Address of Factory:        No. 8, Qinglan 1st Road, Pingshan, Shenzhen, Guangdong 518118, P. R. China.
Equipment Under Test (EUT):
EUT Name:                  Collaboration Touch Screen
Model No.:                 X7, X7-x, X7-xx, X7-xxx (x =0-9, a-z or A-Z) ♣
♣                          Please refer to section 2 of this report which indicates which model was actually
                           tested and which were electrically identical
FCC ID:                                                    2ACYT-BNL15X7
Standards:                                                 47 CFR PART 15,Subpart B:2014
Date of Receipt:                                           2015-07-20
Date of Test:                                              2015-08-10 to 2015-08-18
Date of Issue:                                             2015-09-29
 Test Result :                     Pass*
* In the configuration tested, the EUT complied with the standards specified above.




                  Jack Zhang
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.
The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the
federal government. All test results in this report can be traceable to National or International Standards.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      2 of 21

2          Test Summary
                             Item                                  Standard                                      Method                                     Class                       Result
                  Conducted
            Disturbance at Mains                           47 CFR PART
                                                                                                              ANSI C63.4                                  Class B                         Pass
                  Terminals                               15,Subpart B:2014
              (150kHz-30MHz)
            Radiated Disturbance                           47 CFR PART
                                                                                                              ANSI C63.4                                  Class B                         Pass
               (30MHz-1GHz)                               15,Subpart B:2014
            Radiated Disturbance                           47 CFR PART
                                                                                                              ANSI C63.4                                  Class B                         Pass
                (above 1GHz)                              15,Subpart B:2014

              The highest frequency of the                                            Upper frequency of measurement Range
               internal sources of the EUT
              Below 1.705MHz                                                          30MHz
              1.705MHz to 108MHz                                                      1GHz
              108MHz to 500MHz                                                        2GHz
              500MHz to 1GHz                                                          5GHz
              Above 1GHz                                                              5th harmonic of the highest frequency or 40GHz, whichever is
                                                                                      lower
            Remark:
            Model No.: X7, X7-x, X7-xx, X7-xxx (x =0-9, a-z or A-Z)
            Only the model X7 was tested, since the electrical circuit design, layout, components used and internal
            wiring were identical for the above models, only different on outlook silkprint, color and model number.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      3 of 21

3          Contents
                                                                                                                                                                                                 Page
1         COVER PAGE ............................................................................................................................................1

2         TEST SUMMARY .................................................................................................................................................... 2

3         CONTENTS .............................................................................................................................................................. 3

4         GENERAL INFORMATION .................................................................................................................................... 4
     4.1       DETAILS OF E.U.T. ................................................................................................................................................. 4
     4.2       DESCRIPTION OF SUPPORT UNITS ............................................................................................................................ 4
     4.3       STANDARDS APPLICABLE FOR TESTING .................................................................................................................. 5
     4.4       TEST LOCATION ...................................................................................................................................................... 6
     4.5       TEST FACILITY ........................................................................................................................................................ 6
     4.6       DEVIATION FROM STANDARDS................................................................................................................................ 6
     4.7       ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................... 6
5         EQUIPMENT LIST ................................................................................................................................................... 7

6         EMISSION TEST RESULTS .................................................................................................................................. 9
     6.1 CONDUCTED DISTURBANCE AT MAINS TERMINALS(150KHZ-30MHZ)................................................................... 9
        6.1.1 E.U.T. Operation ........................................................................................................................................ 9
        6.1.2 Test Setup................................................................................................................................................. 10
        6.1.3 Measurement Data .................................................................................................................................. 10
     6.2 RADIATED DISTURBANCE(30MHZ-1GHZ) ........................................................................................................... 13
        6.2.1 E.U.T. Operation ...................................................................................................................................... 13
        6.2.2 Measurement Data .................................................................................................................................. 13
     6.3 RADIATED DISTURBANCE(ABOVE 1GHZ) ............................................................................................................. 16
        6.3.1 E.U.T. Operation ...................................................................................................................................... 16
        6.3.2 Measurement Data .................................................................................................................................. 16
7         PHOTOGRAPHS ................................................................................................................................................... 19
     7.1       CONDUCTED DISTURBANCE AT MAINS TERMINALS(150KHZ-30MHZ) TEST SETUP ............................................. 19
     7.2       RADIATED DISTURBANCE(30MHZ-1GHZ) TEST SETUP........................................................................................ 19
     7.3       RADIATED DISTURBANCE(ABOVE 1GHZ) TEST SETUP ......................................................................................... 20
     7.4       EUT CONSTRUCTIONAL DETAILS ......................................................................................................................... 21




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      4 of 21

4          General Information
4.1 Details of E.U.T.
           Power Supply:                                               Input voltage: AC100-240V 50/60Hz
                                                                       Test voltage: AC120V 60Hz
                                                                       DC 3V (1.5V x 2"AAA"Size batteries) for remote control
           Cable:                                                      AC cable:180cm unshielded
                                                                       USB cable:500cm shielded with two ferrite core
                                                                       HDMI cable:295cm shielded
           Internal source                                             Above 1GHz

4.2 Description of Support Units

                        Description                                                   Manufacturer                                                  Model No.
                          Laptop                                                         Lenovo                                                       T430u
                          Mouse                                                          Lenovo                                                     MO28UOA
                   MITSUBISHI Television                                               MITSUBISHI                                                     AX025
                          U-disk                                                        Color turn                                                 UL4GHKXG
                          Router                                                        NETGEAR                                                     DGN2200
                          Router                                                        NETGEAR                                                     JNR3300
                         SD Card                                                         Kingston                                                   SD-K08G
                         Earphone                                                        PHILIPS                                                    SHE6000
                       AUX IN Cable                                                     SAMZHE                                                      YPH-8310
                        HDMI Cable                                                   Supplied by SGS                                             REF. No.SEA0900
                        VGA Cable                                                    Supplied by SGS                                             REF. No.SEA3300
                       Network Cable                                                 Supplied by SGS                                             REF. No.SEA1100
                    X-PC(OPS port load)                                              Supplied by client                                              XJ-0581




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                             SGS—CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                           Report No.: SZEM150r00425e01
                                                           Page        S of21

4.3 Standards Applicable for Testing
                "Table 1 Tests Garried Out Under 47 CFR. PART 15.Subport Bra0re
     Method                          htem                                          Status
     ansicosa                        Condscted Disurbanceat Mains Terminals           /
                                     pisoute—coutHe
     ansicssa                        Rediated Disturbance(@MHe—1GHe)                 /
     Anslossa                        Redated Disturbance(cbove 1GHz                  /
     x     Incleates tratthetosis not applcable
     Y     Indeates tratthetest is appleable


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      6 of 21


4.4 Test Location
             All tests were performed at:
             SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
             No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
             518057.
             Tel: +86 755 2601 2053                                  Fax: +86 755 2671 0594


             No tests were sub-contracted.

4.5 Test Facility
           The test facility is recognized, certified, or accredited by the following organizations:
           • CNAS (No. CNAS L2929)
           CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC Lab
            to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
           Laboratories) for the competence in the field of testing.
           • A2LA (Certificate No. 3816.01)
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
           American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
           • VCCI
           The 10m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
            Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with
           Registration No.: G-823, R-4188, T-1153 and C-2383 respectively.
           • FCC – Registration No.: 556682
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been registered
            and fully described in a report filed with the (FCC) Federal Communications Commission. The
           acceptance letter from the FCC is maintained in our files. Registration No.: 556682.
           • Industry Canada (IC)
           The 3m Semi-anechoic chambers and the 10m Semi-anechoic chambers of SGS-CSTC Standards
            Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
            Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-2,
            4620C-3.

4.6 Deviation from Standards
           None

4.7 Abnormalities from Standard Conditions
           None




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      7 of 21

5          Equipment List
                  Conducted Disturbance at Mains Terminals(150kHz-30MHz)

                                                                                                                               Inventory                  Cal. date                  Cal Due
    Item                   Equipment                             Manufacturer                         Model No
                                                                                                                                  No                   (yyyy-mm-dd)                   Date

                                                                   ChangZhou
         1             Shielding Room                                                                    GB-88                  SEL0042                 2015-05-13                 2016-05-13
                                                                    ZhongYu
         2                       LISN                         Rohde & Schwarz                          ENV216                   SEL0152                 2015-10-09                 2016-10-09
         3                       LISN                          ETS-LINDGREN                              3816/2                 SEL0021                 2015-05-13                 2016-05-13
         4           EMI Test Receiver                        Rohde & Schwarz                             ESCI                  SEL0022                 2015-05-13                 2016-05-13
         5               Coaxial Cable                                    SGS                               N/A                 SEL0025                 2015-05-13                 2016-05-13


                  Radiated Disturbance
                                                                                                                               Inventory                 Cal. date                   Cal Due
    Item                   Equipment                             Manufacturer                         Model No
                                                                                                                                  No                   (yyyy-mm-dd)                   Date
                   10m Semi-Anechoic
         1                                                             SAEMC                         FSAC1018                   SEL0303                 2015-08-01                 2016-08-01
                       Chamber
         2           EMI Test Receiver                        Rohde & Schwarz                              ESR                  SEL0295                 2015-05-13                 2016-05-13
         3           EMI Test software                                  AUDIX                                E3                 SEL0050                        N/A                        N/A
         4               Coaxial cable                                    SGS                               N/A                 SEL0288                 2015-05-13                 2016-05-13
         5               Coaxial cable                                    SGS                               N/A                 SEL0275                  2015-05-13                2016-05-13
         6               Coaxial cable                                    SGS                               N/A                 SEL0274                  2015-05-13                2016-05-13
                      BiConiLog
         7                                                        Schwarzbeck                        VULB9160                   SEL0308                  2015-10-17                 2018-10-17
                  Antenna(30M-1GHz)
                      BiConiLog
         8                                                        Schwarzbeck                        VULB9160                   SEL0309                  2015-10-17                 2018-10-17
                  Antenna(30M-1GHz)
                      Horn Antenna(1-
         9                                                    Rohde & Schwarz                            HF907                  SEL0310                  2015-06-14                 2018-06-14
                          18GHz)
                                                            Sonoma Instrument
        10                Pre-amplifier                                                                   310N                  SEL0298                  2015-05-13                 2016-05-13
                                                                  Co




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      8 of 21


                  General used equipment
                                                                                                                                                            Cal. date Cal.Due date
     Item                      Equipment                            Manufacturer                    Model No                Inventory No
                                                                                                                                                          (yyyy-mm-dd) (yyyy-mm-dd)
                                              Shang Hai
                      Humidity/Temperature
          1                                 Meteorological                                             ZJ1-2B                     SEL0101                  2015-10-12 2016-10-12
                            Indicator
                                           Industry Factory
                                              Shang Hai
                      Humidity/Temperature
          2                                 Meteorological                                             ZJ1-2B                     SEL0102                  2015-10-12 2016-10-12
                            Indicator
                                           Industry Factory
                                              Shang Hai
                      Humidity/Temperature
          3                                 Meteorological                                             ZJ1-2B                     SEL0103                  2015-10-12 2016-10-12
                            Indicator
                                           Industry Factory
                                             Chang Chun
          4               Barometer         Meteorological                                               DYM3                     SEL0088                  2015-05-13 2016-05-13
                                           Industry Factory




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      9 of 21

6          Emission Test Results
6.1 Conducted Disturbance at Mains Terminals(150kHz-30MHz)
           Test Requirement:                                  47 CFR PART 15,Subpart B:2014
           Test Method:                                       ANSI C63.4
           Frequency Range:                                   150kHz to 30MHz
           Limit:
           0.15M-0.5MHz                                       66dB(µV)-56dB(µV) quasi-peak, 56dB(µV)-46dB(µV) average
           0.5M-5MHz                                          56dB(µV) quasi-peak, 46dB(µV) average
           5M-30MHz                                           60dB(µV) quasi-peak, 50dB(µV) average
           Detector:                                          Peak for pre-scan (9kHz resolution bandwidth) 0.15M to 30MHz
6.1.1 E.U.T. Operation
           Operating Environment:
             Temperature: 23.0 °C                                             Humidity:              54 % RH                          Atmospheric Pressure:                             1010 mbar
                                               a:HDMI1 mode: Keep EUT working with external HDMI source via front panel HDMI
                                               port and HDMI signal output via rear panel HDMI port.
                                               b: HDMI2 mode: Keep EUT working with external HDMI source via rear panel HDMI
                                               rear port and HDMI signal output via rear panel HDMI port.
                                               c: LAN mode: Build the connection between EUT and internet, Keep EUT working
                                               with external internet source.
           Pretest these                       d: VGA and Audio in mode: Set the brightness and contrast to the maximum. Kept
                                               displaying character "H" in all screen. Set character size and number of characters
           mode to find                        per line so that typically the greatest number of characters per screen is displayed.
                                               e:SD card mode : Keep EUT playing with SD card.
           the worst case:
                                               f:USB mode :Keep EUT working with 1-8 USB ports, pretest at each ports to find the
                                               worst case.
                                               g:Top camera mode: Keep EUT recording via top camera.
                                               h::Bottom camera mode: Keep EUT recording via bottom camera.
                                               i: MIC record mode:Keep EUT recording via micphone.
                                               j: Normally working mode, keep EUT working normally.
                                               a:HDMI1 mode: Keep EUT working with external HDMI source via front panel HDMI
           The worst case                      port and HDMI signal output via rear panel HDMI port.
             for final test:




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      10 of 21

6.1.2 Test Setup




6.1.3 Measurement Data

           An initial pre-scan was performed with peak detector.Quasi-Peak or Average measurement were
           performed at the frequencies with maximized peak emission were detected.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      11 of 21


Mode:a;Line:Live Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      12 of 21


Mode:a;Line:Neutral Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      13 of 21



6.2 Radiated Disturbance(30MHz-1GHz)
           Test Requirement:                                  47 CFR PART 15,Subpart B:2014
           Test Method:                                       ANSI C63.4
           Frequency Range:                                   30MHz to 1GHz
           Limit:
           30MHz -88MHz                                       29.5(dBµV/m) quasi-peak
           88MHz-216MHz                                       33.0(dBµV/m) quasi-peak
           216MHz-960MHz                                      35.6(dBµV/m) quasi-peak
           960MHz-1000MHz                                     44.4(dBµV/m) quasi-peak
           Detector:                                          Peak for pre-scan (120kHz resolution bandwidth) 30M to1000MHz
6.2.1 E.U.T. Operation
           Operating Environment:
             Temperature: 23.0 °C                                             Humidity:              56 % RH                          Atmospheric Pressure:                             1010 mbar
                                               a:HDMI1 mode: Keep EUT working with external HDMI source via front panel HDMI
                                               port and HDMI signal output via rear panel HDMI port.
                                               b: HDMI2 mode: Keep EUT working with external HDMI source via rear panel HDMI
                                               rear port and HDMI signal output via rear panel HDMI port.
                                               c: LAN mode: Build the connection between EUT and internet, Keep EUT working
                                               with external internet source.
           Pretest these                       d: VGA and Audio in mode: Set the brightness and contrast to the maximum. Kept
                                               displaying character "H" in all screen. Set character size and number of characters
           mode to find                        per line so that typically the greatest number of characters per screen is displayed.
                                               e:SD card mode : Keep EUT playing with SD card.
           the worst case:
                                               f:USB mode :Keep EUT working with 1-8 USB ports, pretest at each ports to find the
                                               worst case.
                                               g:Top camera mode: Keep EUT recording via top camera.
                                               h::Bottom camera mode: Keep EUT recording via bottom camera.
                                               i: MIC record mode:Keep EUT recording via micphone.
                                               j: Normally working mode, keep EUT working normally.
                                               a:HDMI1 mode: Keep EUT working with external HDMI source via front panel HDMI
           The worst case
                                               port and HDMI signal output via rear panel HDMI port.
             for final test:
6.2.2 Measurement Data

           An initial pre-scan was performed in the chamber using the spectrum analyser in peak detection mode.
           Quasi-peak measurements were conducted based on the peak sweep graph. The EUT was measured
           by BiConiLog antenna with 2 orthogonal polarities.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      14 of 21


Mode:a;Polarization:Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      15 of 21


Mode:a;Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      16 of 21



6.3 Radiated Disturbance(above 1GHz)
           Test Requirement:                                  47 CFR PART 15,Subpart B:2014
           Test Method:                                       ANSI C63.4
           Frequency Range:                                   Above 1GHz
           Limit:
           Above 1GHz                                         74(dBµV/m) peak, 54(dBµV/m) average
           Detector:                                          Peak for pre-scan (1000kHz resolution bandwidth) 1000M to18000MHz
6.3.1 E.U.T. Operation
           Operating Environment:
             Temperature: 23.0 °C                                             Humidity:              56 % RH                          Atmospheric Pressure:                             1010 mbar
                                               a:HDMI1 mode: Keep EUT working with external HDMI source via front panel HDMI
                                               port and HDMI signal output via rear panel HDMI port.
                                               b: HDMI2 mode: Keep EUT working with external HDMI source via rear panel HDMI
                                               rear port and HDMI signal output via rear panel HDMI port.
                                               c: LAN mode: Build the connection between EUT and internet, Keep EUT working
                                               with external internet source.
           Pretest these                       d: VGA and Audio in mode: Set the brightness and contrast to the maximum. Kept
                                               displaying character "H" in all screen. Set character size and number of characters
           mode to find                        per line so that typically the greatest number of characters per screen is displayed.
                                               e:SD card mode : Keep EUT playing with SD card.
           the worst case:
                                               f:USB mode :Keep EUT working with 1-8 USB ports, pretest at each ports to find the
                                               worst case.
                                               g:Top camera mode: Keep EUT recording via top camera.
                                               h::Bottom camera mode: Keep EUT recording via bottom camera.
                                               i: MIC record mode:Keep EUT recording via micphone.
                                               j: Normally working mode, keep EUT working normally.
                                               a:HDMI1 mode: Keep EUT working with external HDMI source via front panel HDMI
           The worst case
                                               port and HDMI signal output via rear panel HDMI port.
             for final test:
6.3.2 Measurement Data

           An initial pre-scan was performed in the chamber using the spectrum analyser in peak detection mode.
           Average measurements were conducted based on the peak sweep graph. The EUT was measured by
           BiConiLog antenna with 2 orthogonal polarities.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      17 of 21


Mode:a;Polarization:Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      18 of 21


Mode:a;Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      19 of 21


7         Photographs
7.1 Conducted Disturbance at Mains Terminals(150kHz-30MHz) Test Setup




7.2 Radiated Disturbance(30MHz-1GHz) Test Setup




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      20 of 21

7.3 Radiated Disturbance(above 1GHz) Test Setup




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                                                 Shenzhen Branch
                                                                                                                                Report No.: SZEM150700425801
                                                                                                                                Page:                      21 of 21

7.4 EUT Constructional Details
           Refer to Appendix A - Photographs of EUT Constructional Details for SZEM1507004258CR.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only



Document Created: 2015-11-04 01:33:41
Document Modified: 2015-11-04 01:33:41

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC