Users Manual

FCC ID: 2ACVD05601045

Users Manual

Download: PDF
FCCID_2679699

                                     testo 104-IR BT
   Combined infrared and penetration thermometer with
                                          Bluetooth®




                    n a r y
    pre        limi
Instruction manual                                en


              2                                                        1. General information 3




                  1. General information




                                                                                                    de
                  Please read this document through carefully and familiarize
                  yourself with the operation of the product before putting it to use.




                                                                                                    en
                  Keep this document to hand so that you can refer to it when
                  necessary.




                                                                                                    fr
                  2. Safety information




                                                                                                    es
preliminary



                      Avoid electrical hazards:




                                                                                                    it
                     Do not conduct measurements on or near live parts!




                                                                                                    pt
                       Adhere to the product safety/warranty requirements:
                     Always operate the instrument properly and according to its




                                                                                                    sv
                     intended purpose and within the parameters specified. Do not
                     use force.




                                                                                                    nl
                     Do not store with solvents (e.g. acetone).
                     Only open the instrument if this is expressly described in the




                                                                                                    ??
                     documentation for the purpose of maintenance or repair work.




                                                                                                    ??
                       Ensure correct disposal:
                     Dispose of defective rechargeable batteries and spent
                     batteries at the collection points provided.
                     Send the instrument directly to us at the end of its life cycle.
                     We will ensure that it is disposed of in an environmentally
                     friendly manner.

                  3. Intended use
                  The testo 104-IR BT is a robust food thermometer.
                  The product is designed for the following tasks/areas:
                  · Food sector: production, food service, spot check
                    measurement, incoming goods.
                  · Measuring liquids, pastes and semi-solid materials
                              The following product components are designed for continuous
                              contact with foodstuffs in accordance with Regulation (EC)
                              1935/2004:
                              The immersion/penetration probe from the tip up to 2 cm before the
                              probe handle or the plastic housing. If provided, information about
                              penetration depths in the instruction manual or the mark(s) on the
                              immersion/penetration probe should be observed.
                  The product should not be used in the following areas:
                  · Potentially explosive areas
                  · For diagnostic measurements in the medical sector


              4 4. Technical data                                                                                                                                  5. Product description 5




               4. Technical data                                                                    4.2 General Technical data




                                                                                                                                                                                                  de
                                                                                                    Feature                          Values
               4.1 Bluetooth Modul                                                                  Penetration probe




                                                                                                                                                                                                  en
                                                                                                    Sensor type                      NTC
                   The Bluetooth® option may only be operated in countries in
                                                                                                    Measuring range                  -50 to +250 °C / -58 to +482 °F
                   which it is type approved.                                                       Resolution                       0.1 °C/°F/°R




                                                                                                                                                                                                  fr
preliminary


                Feature                 Values                                                      Accuracy (±1 digit)              ±1.0 °C / ±1.8 °F (-50,0 to-30,1°C / -58.0 to -22.1 °F)
                Bluetooth               Range >20 m (free field)                                                                     ±0.5 °C / ±0.9 °F (-30,0 to +99,9°C / -22.0 to +211.9 °F)
                                                                                                                                     ±1 % of the measuring range (+100.0 to +250.0 °C / +212.0




                                                                                                                                                                                                  es
                luetooth type           LSD Science & Technology Co., Ltd
                                        L Series BLE Module (08 Mai 2013) based on TI CC254X chip                                    to +482.0 °F)
                Qualified Design ID     B016552                                                     Response time t99                10 s (measured in moving liquid)
                Bluetooth radio class   Class 3                                                     Measuring rate                   0.5 s




                                                                                                                                                                                                  it
                Bluetooth company       10274                                                       Infrared measurement
                                                                                                    Lens                             10:1 + opening diameter of the sensor (12 mm / 0.47”)




                                                                                                                                                                                                  pt
               Certification                                                                        Spectral range                   8 to 14 μm
               Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE),                             Laser type                       2-point laser
                                                                                                    Output / wavelength              < 1 mW / 650nm




                                                                                                                                                                                                  sv
               Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland (IE),                  Class / standard                 2 / DIN EN 60825-1:2007
               Italy (IT), Latvia (LV), Lithuania (LT), Luxembourg (LU), Malta                      Measuring range                  -30 - +250 °C / -22 - +482 °F
               (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT),                    Resolution                       0.1 °C/°F/°R




                                                                                                                                                                                                  nl
               Romania (RO), Sweden (SE), Slovakia (SK), Slovenia (SI), Spain                       Accuracy (at 23°C, ±1 digit)     ±2.5 °C / ±4.5 °F (-30.0 to -20.1 °C / -22.0 to -4.2 °F)
                                                                                                                                     ±2.0 °C / ±3.6 °F (-20.0 to -0.1 °C / -4.1 to 31.9 °F)
               (ES), Czech Republic (CZ), Hungary (HU), United Kingdom (GB),




                                                                                                                                                                                                  ??
                                                                                                                                     ±1.5 °C / ±2.7 °F or ±1.5 % of the measuring value (0.0 to
               Republic of Cyprus (CY).                                                                                              +250.0 °C / +32.0 to +482.0 °F)
                                                                                                    Measuring rate                   0.5 s
               EFTA countries




                                                                                                                                                                                                  ??
                                                                                                    General
               Norway and Switzerland.                                                              Operating temperature            -20 to +50 °C / -4 to +122 °F
               Other countries                                                                      Transportation/                  -30...+70 °C / -22 to +158 °F (without batteries)
                                                                                                    storage temperature
               USA, Canada, Turkey, Australia, New Zealand, South Korea,                            Power supply                     2 x AAA batteries
               India, Russia, Japan                                                                 Battery life                     10 h (typical at 25°C / 77°F)
                                                                                                    Housing                          ABS/TPE/PC and die-cast zinc/stainless steel
               Information from the FCC (Federal Communications                                     Protection class                 IP65
               Commission)                                                                          Dimensions                       281 x 48 x 21 mm / 11.06 x 1.89 x 0.83“ (immersion/
               This device complies with part 15 of the FCC Rules.                                                                   penetration probe folded out)
                                                                                                                                                      178 x 48 x 21 mm / 7.01 x 1.89 x 0.83”
               Commissioning is subject to the two following conditions: (1) This                                                    (immersion/penetration probe folded up)
               instrument must not cause any harmful interference and (2) this                      Weight                           210g / 0.433lbs (incl. batteries)
               instrument must be able to cope with interference, even if this has                  Standards                        EN 13485
                                                                                                    EC Directive                     2004/108/EC
               undesirable effects on operation.                                                    Warranty                         2 years, warranty terms: see www.testo.com/warranty
               Changes
               The FCC demands that the user be informed that any changes or                        Information on standards
                                                                                                                                   This product complies with the EN 13485 standard for
               modifications to the instrument that are not explicitly approved by                                                 penetration measurement.
               Testo AG may void the user’s right to use this instrument.                                                          Suitability: S, T (storage, transportation)
                                                                                                                                   Environment: E (transportable thermometer)
                                                                                                                                   Accuracy class: 0.5
                                                                                                                                   Measuring range: -50...+250 °C
                                                                                                                                   According to EN 13485, the measuring instrument should
                                                                                                                                   be checked and calibrated regularly under the terms of
                                                                                                                                   EN 13486 (recommended frequency: yearly).
                                                                                                                                   Contact us for more information.


              6 7. Operation                                                                                                            8. Settings 7




               5. Product description                                            7. Operation




                                                                                                                                                       de
                                     1 Infrared sensor
                                                                                 7.1 Switching on/off




                                                                                                                                                       en
                                     2 2-point laser
                                     3 Display                                   Switching on via fold-out probe




                                                                                                                                                       fr
                                     4 Control keys:
preliminary


                                                                                   Fold out the probe.
                                       · [ON]: switches the instrument on        - All display segments light up briefly. Contact measurement is




                                                                                                                                                       es
                                       · [OFF]: switches the instrument off        enabled (       lights up).
                                         (hold button down)
                                       · [ ]: switches to IR measurement,        Switching on/off via control keys




                                                                                                                                                       it
                                         carry out IR measurement (hold button     Switch the instrument on: press [ON].
                                         down)                                   - All display segments light up briefly. IR measurement is




                                                                                                                                                       pt
                                       · [ ]: switches to contact measurement      enabled (        lights up).
                                       · [HOLD/MIN/MAX]: holds measuring           Switch off the instrument: press and hold down [OFF] until the




                                                                                                                                                       sv
                                         value, displays minimum/maximum           display goes off.
                                         value, sends data to mobile device
                                                                                   The instrument switches off automatically if no key is pressed:




                                                                                                                                                       nl
                                         (Bluetooth)
                                                                                   for 10 minutes when the probe is folded out, or for 1 minute
                                     5 Fold-out immersion/penetration probe,       when the probe is folded up.




                                                                                                                                                       ??
                                       folding out the probe switches the
                                       instrument on                             7.2 Changing the measuring mode




                                                                                                                                                       ??
                                     6 Battery compartment (at the back)           Contact measurement —> IR measurement: press [ ].
                                                                                   IR measurement —> contact measurement: press [ ].
                                                                                 7.3 Measuring
                                                                                   Observe the information on IR measurement/contact
               6. Commissioning                                                    measurement (see chapter below).
               Inserting batteries                                                  Bluetooth mode Cnl1 (Controlled Mode) is enabled: Display
                                                                                    shows bLE, all buttons are locked, instrument can be
                                     1 Use a slotted screwdriver to undo the
                                                                                    controlled by external mobile device only.
                                       screw on the battery compartment.
                                                                                 IR measurement
                                     2 Open the battery compartment.
                                                                                 - Instrument is on, IR measurement is enabled, Bluetooth mode
                                     3 Insert batteries (2x type AAA). Observe      Cnl2 (Autonomous Mode) is enabled.
                                       the polarity!                             1 Start measurement: press and hold down [ ].
                                     4 Close the battery compartment.            2      Lock in on measurement object using the laser points:
                                                                                        laser points mark the edges of the measuring range.
                                     5 Tighten the screw.
                                                                                 - The current measuring value is displayed.
                                                                                 3 End measurement: release the key.
                                                                                 - Hold lights up. The last measuring value and min./max. value
                                                                                    are saved until the next measurement, or until the instrument is
                                                                                    switched off.
                                                                                 4 Send data to mobile device: press [HOLD / MIN / MAX].
                                                                                    Switch between min., max. and recorded value: press [HOLD /
                                                                                    MIN / MAX].


              8 9. Service and maintenance                                                                  11. Information on infrared (IR) measurement 9




                  The min./max. values can be reset:                                 5 Select Bluetooth mode Cnl1 (Controlled Mode) oder Cnl2




                                                                                                                                                                      de
                                                                                       (Autonomous Mode): press [ ] or [ ].
                 · press [ ] or switch the instrument off.                           - The instrument switches to IR measurement.
                 Restart measurement: press and hold down [ ].




                                                                                                                                                                      en
                 Setting the emission level:                                         9. Service and maintenance
                 · When IR measurement is enabled, press and hold down[ ]




                                                                                                                                                                      fr
preliminary


                   and [ ] at the same time (         lights up).                    9.1 Changing the batteries
                 · Emission level is displayed.
                                                                                                              1 Use a slotted screwdriver to undo the




                                                                                                                                                                      es
                 · Use [ ] or [ ] to change the value and wait for 3 s.
                                                                                                                screw on the battery compartment.
               Contact measurement
                                                                                                              2 Open the battery compartment.




                                                                                                                                                                      it
               - Instrument is on, contact measurement is enabled (         lights
                 up), Bluetooth mode Cnl2 (Autonomous Mode) is enabled.                                       3 Insert batteries (2x type AAA). Observe




                                                                                                                                                                      pt
               1 Position the contact thermometer in the measurement object                                     the polarity!
                 and initiate the measurement: press [ ].                                                     4 Close the battery compartment.
               2 End measurement: press [HOLD / MIN / MAX].




                                                                                                                                                                      sv
                                                                                                              5 Tighten the screw.
               - Hold lights up. The last measuring value and min./max. value
                 are saved until the next measurement, or until the instrument is    9.2 Cleaning the instrument




                                                                                                                                                                      nl
                 switched off.
                                                                                     Only use weak, commercially available neutral/household cleaning
                 AutoHold function: if this function is enabled, the measurement     agents (e.g. washing-up liquid) to clean the instrument. Do not




                                                                                                                                                                      ??
                 is ended automatically as soon as the measuring value is            use aggressive cleaning agents or solvent!
                 stable, AutoHold lights up.




                                                                                                                                                                      ??
                                                                                     The housing and probe can be disinfected using an alcohol-
               4 Send data to mobile device: press [HOLD / MIN / MAX].
                                                                                     based spray. In doing so, always follow the manufacturer’s
                 Switch between min., max. and recorded value:                       instructions.
                 press [HOLD / MIN / MAX].
                                                                                        Clean the housing and probe under running water and rub dry
                 The min./max. values can be reset:                                     with a towel.
                  · switch the instrument off, switch to IR measurement or, while       Clean the lens carefully with a cotton bud dipped in water or
                    the held measuring value is displayed (Hold lights up), press       medical alcohol.
                    and hold down [HOLD / MIN / MAX] until Clr lights up.
                  Restart measurement: press [ ].                                    10. Questions and answers
               8. Settings                                                           Question
                                                                                             lights up
                                                                                                              Possible causes
                                                                                                              Low battery
                                                                                                                                                  Possible solution
                                                                                                                                                Change batteries.
               - The instrument is switched off.                                     IR measurement:          Measuring values                  Keep to permissible
                                                                                       - - - lights up.         outside measuring range         measuring range.
                 If no button is pressed for 3 s in settings mode, the instrument    Contact measurement:     Valores de medición               Keep to measuring
                                                                                     - - - lights.            outside permissible range         range.
                 switches to the next view.                                          Instrument cannot        Batteries dead.                   Change batteries.
               1 Press and hold down [ ] and [ ] until AutoHold or Hold              be switched on
                 flashes.                                                            Instrument               Instrument switches off           Switch the
                                                                                     switches itself off.     automatically after 10 min        instrument on again
               2 Switch the AutoHold function on (AutoHold) or off (Hold): press                              in contact measurement mode
                 [ ] or [ ].                                                                                  and after 1 min after switching
                                                                                                              on in IR measurement mode.
               - °C, °F or °R flashes.
               3 Set measurement unit to degrees Celsius (°C), degrees
                 Fahrenheit (°F) or degrees Réaumur (°R): press [ ] or [ ].          If we have not been able to answer your question, please contact
               - flashes.                                                            your local dealer or Testo Customer Service. For contact details,
               4 Switch the laser on (on) or off (oFF): press [ ] or [ ].            please visit www.testo.com/service-contact.


              10 12. Information on contact measurement                                                                                                   11




                11. Information on infrared (IR)                                         11.3 Measuring range, distance




                                                                                                                                                          de
                    measurement                                                          Depending on the distance of the measuring instrument from the
                                                                                         measurement object, a specific measuring range is recorded.




                                                                                                                                                          en
                11.1 Measuring method                                                    Measuring lens (ratio of distance : measuring range)
                                                                                         In italics = laser
                IR measurement is a visual measurement                                   Not in italics = measuring range




                                                                                                                                                          fr
preliminary


                    Keep lens clean.
                    Do not carry out measurement with a foggy lens.




                                                                                                                                                          es
                    Keep the measuring range (the range between the instrument
                    and the measurement object) free of obstacles. There must be
                    no particles of dust or dirt, no humidity (rain, steam) and no




                                                                                                                                                          it
                    gases.
                IR measurement is a surface measurement




                                                                                                                                                          pt
                If there is dirt, dust, frost, etc. on the surface, only the outermost
                layer is measured, i.e. the dirt.




                                                                                                                                                          sv
                    For vacuum-packed food, do not measure at air pockets.
                    Where the values are critical, always measure separately




                                                                                                                                                          nl
                    with a contact thermometer. Particularly in the food sector:
                    measure core temperature with a penetration/immersion                * Optimised measuring distance




                                                                                                                                                          ??
                    thermometer.
                Adjustment time                                                          12. Information on contact




                                                                                                                                                          ??
                    If the ambient temperature changes (change of location,
                    e.g. measurement indoors/outdoors), the instrument must be
                                                                                             measurement
                    allowed to equalise for 15 minutes for infrared measurement.             Observe the minimum penetration depth for immersion/
                                                                                             penetration probes:
                11.2 Emissivity                                                              10x probe diameter
                Materials have different emission levels. This means they emit               Avoid using in aggressive acids or alkalis.
                various amounts of electromagnetic radiation. The emission level
                of the instrument has a default setting of 0.95. This is ideal for
                the measurement of food, non-metals (paper, ceramic, gypsum,
                wood, paints and varnishes) and plastics.


preliminary




                                                          www.testo.com



              testo AG
              Postfach 11 40, 79849 Lenzkirch
              Testo-Straße 1, 79853 Lenzkirch
              Telefon: (0 76 53) 6 81 - 0
              Fax: (0 76 53) 6 81 - 1 00
              E-Mail: info@testo.de
              Internet: http://www.testo.com




                                                0977 1042 en 01a


FCC statements:
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications or changes to this equipment. Such modifications or
changes could void the user’s authority to operate the equipment.




This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Power is so low that no RF exposure calculation is needed.



Document Created: 2015-07-15 09:36:30