Test Report

FCC ID: 2ACVD-1549

Test Report

Download: PDF
FCCID_2826339



                                                                                                        REPORT No.: SZ15090025W04



                                                                 DIRECTORY

 TEST REPORT DECLARATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙4


 1.    TECHNICAL INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5


 1.1 APPLICANT INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
 1.2 EQUIPMENT UNDER TEST (EUT) DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
 1.2.1 IDENTIFICATION OF ALL USED EUTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
 1.3 TEST STANDARDS AND RESULTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6
 1.3.1 TEST ENVIRONMENT CONDITIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6


 2.    47 CFR PART 15C REQUIREMENTS∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7


 2.1     ANTENNA REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 2.1.1     APPLICABLE STANDARD ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 2.1.2     RESULT: COMPLIANT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 2.2     PEAK OUTPUT POWER∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 2.2.1     REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 2.2.2     TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 2.2.3     TEST RESULT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
 2.3     6DB BANDWIDTH ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10
 2.3.1     REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10
 2.3.2     TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10
 2.3.3     TEST RESULT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10
 2.4     CONDUCTED SPURIOUS EMISSIONS AND BAND EDGE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
 2.4.1     REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
 2.4.2     TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
 2.4.3     TEST RESULT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13
 2.5     POWER SPECTRAL DENSITY (PSD) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙17
 2.5.1     REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17
 2.5.2     TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17
 2.5.3     TEST RESULT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17
 2.6     RESTRICTED FREQUENCY BANDS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙20
 2.6.1     REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 20
 2.6.2     TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 20
 2.6.3     TEST RESULT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21


                                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,            Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                                       Page 2 0f 34


                                                                                                         REPORT No.: SZ15090025W04


 2.7 RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙24
 2.7.1 REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 24
 2.7.2 TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 25
 2.7.3 TEST RESULT∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 27
 2.8 RF EXPOSURE EVALUATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙31
 2.8.1 REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 31
 2.8.2 RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 31


 ANNEX A GENERAL INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙32



                                                                     Change History
  Issue                 Date                                                            Reason for change
    1.0            2015-11-17                                                                 First edition




                                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,          Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P                               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                                     Page 3 0f 34




                                                                                        REPORT No.: SZ15090025W04



 1. TECHNICAL INFORMATION
 Note: Provide by applicant.

 1.1    Applicant Information
   Company:               Testo Instruments (Shenzhen) Co., Ltd
   Address:               Block A, B4 Building, China Merchants Guangming Sci&Tech Park,
                          No.3009 Guan Guang Road, Guangming New District, Shenzhen City


 1.2    Equipment under Test (EUT) Description
   Brand Name:            testo
   Trade Name:            testo
   Model Name:            testo 549i
   Serial number          49200291
   Frequency Range:       The frequency range used is 2402MHz - 2480MHz (40 channels, at
                          intervals of 2MHz);
   Modulation Type:       GFSK
   Antenna Type:          PCB Antenna
   Antenna Gain:          4.23dBi
 NOTE:
 The EUT is a testo 549i, it contain Bluetooth 4.0 LE Module operating at 2.4GHz ISM band; the
 frequencies allocated for the Bluetooth 4.0 LE is F(MHz)=2402+2*n (0<=n<=39). The lowest,
 middle, highest channel numbers of the Bluetooth Module used and tested in this report are
 separately 0 (2402MHz), 19 (2440MHz) and 39 (2480MHz).
 For a more detailed description, please refer to Specification or User’s Manual supplied by the
 applicant and/or manufacturer.


 1.2.1 Identification of all used EUTs
 The EUT identity consists of numerical and letter characters, the letter character indicates the test
 sample, and the following two numerical characters indicate the software version of the test
 sample.
   EUT Identity         Hardware Version                                                    Software Version
       A01                      V1.1                                                              V1.0




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                  Page 5 0f 34


                                                                                          REPORT No.: SZ15090025W04


 1.3    Test Standards and Results
 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C (Bluetooth,
 2.4GHz ISM band radiators) for the EUT FCC ID Certification:

               No.      Identity                     Document Title
               1        47 CFR Part 15
                                                     Radio Frequency Devices
                        (10-1-13 Edition)

 Test detailed items/section required by FCC rules and results are as below:

       No.    Section                     Description                                         Test Date                     Result
       1      15.203                      Antenna Requirement                                         N.A                   PASS
       2      15.247(b)                   Peak Output Power                                   Oct 17 2015                   PASS
       3      15.247(a)                   Bandwidth                                           Oct 17, 2015                  PASS
                                          Conducted Spurious Emission
       4      15.247(d)                                               Oct 17, 2015                                          PASS
                                          and Band Edge
       5      15.247(d)                   Restricted Frequency Bands                          Oct 26, 2015                  PASS
       6      15.207                      Conducted Emission                                  Oct 26, 2015                  PASS
       7      15.209 ,15.247(d)           Radiated Emission                                   Oct 26, 2015                  PASS
       8      15.247(e)                   Power spectral density (PSD)                        Oct 17 2015                   PASS
       9      15.247(i),1.1307&
                                          RF exposure evaluation                                      N.A                   PASS
              2.1093

 The tests of Conducted Emission and Radiated Emission were performed according to the method
 of measurements prescribed in ANSI C63.4 2009.

 These RF tests were performed according to the method of measurements prescribed in
 KDB558074 D01 v03r03 (09/06/2015).

 1.3.1 Test Environment Conditions
 During the measurement, the environmental conditions were within the listed ranges:
  Temperature (°C):                                 15 - 35
  Relative Humidity (%):                            30 -60
  Atmospheric Pressure (kPa):                       86-106




                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                     Page 6 0f 34


                                                                                       REPORT No.: SZ15090025W04



 2. 47 CFR PART 15C REQUIREMENTS
 2.1    Antenna requirement
 2.1.1 Applicable Standard
 According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other
 than that furnished by the responsible party shall be used with the device. The use of a
 permanently attached antenna or of an antenna that uses a unique coupling to the intentional
 radiator shall be considered sufficient to comply with the provisions of this section.

 2.1.2 Result: Compliant
 The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal
 photos.


 2.2    Peak Output Power
 2.2.1 Requirement
 According to FCC section 15.247(b)(3), For systems using digital modulation in the 902-928 MHz,
 2400-2483.5 MHz, and 5725-5850 MHz bands: The maximum peak conducted output power of the
 intentional radiator shall not exceed 1 Watt.

 2.2.2 Test Description
 The measured output power was calculated by the reading of the spectrum analyzer and
 calibration.

 A. Test Setup:




 The EUT (Equipment under the test) which is powered by the Battery is coupled to the Spectrum
 analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor
 is calibrated to correct the reading, all test result in Spectrum analyzer.



 B. Equipments List:
 Please reference ANNEX A (1.4).




                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 7 0f 34


                                                                                       REPORT No.: SZ15090025W04


 2.2.3 Test Result
 The lowest, middle and highest channels are selected to perform testing to verify the conducted
 RF output peak power of the Module.

 A. Test Verdict:

             Frequency      Measured Output Peak Power                                Refer to           Limit
  Channel                                                                                                                   Verdict
               (MHz)               dBm                            W                    Plot        dBm           W
     0            2402            -0.733                    0.000845                   Plot A                                PASS
     19           2440            -1.163                    0.000765                   Plot B        30           1          PASS
     39           2480            -1.579                    0.000695                   Plot C                                PASS


 B. Test Plots:




                                      (Plot A: Channel 0: 2402MHz)




                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 8 0f 34


                                                                             REPORT No.: SZ15090025W04




                           (Plot B: Channel 19: 2440MHz)




                           (Plot C: Channel 39: 2480MHz)




                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                       Page 9 0f 34


                                                                                        REPORT No.: SZ15090025W04


 2.3     6dB Bandwidth
 2.3.1 Requirement
 According to FCC section 15.247(a) (2), Systems using digital modulation techniques may operate
 in the 902 - 928 MHz, 2400 - 2483.5 MHz, and 5725 - 5850 MHz bands. The minimum 6 dB
 bandwidth shall be at least 500 kHz.


 2.3.2 Test Description

 A. Test Set:




 The EUT which is powered by the battery, is coupled to the Spectrum Analyzer; the RF load
 attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct
 the reading.

 Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In
 order to make an accurate measurement, set the span greater than RBW.

 B. Equipments List:
 Please reference ANNEX A(1.4).


 2.3.3 Test Result
 The lowest, middle and highest channels are selected to perform testing to record the 6 dB
 bandwidth of the module.

 A.    Test Verdict:

                                               6 dB
                       Frequency                                       Refer to
            Channel                         Bandwidth                                       Limits(kHz)          Result
                         (MHz)                                          Plot
                                              (MHz)
                0         2402                  0.6847                   Plot A                ≥500              PASS
               19         2440                  0.6795                   Plot B                ≥500              PASS
               39         2480                  0.6711                  Plot C                 ≥500              PASS

 B. Test Plots:




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 10 0f 34


                                                                             REPORT No.: SZ15090025W04




                            (Plot A: Channel 0: 2402MHz)




                          (Plot B: Channel 19: 2440 MHz)




                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 11 0f 34


                                                                             REPORT No.: SZ15090025W04




                           (Plot C: Channel 39: 2480MHz)




                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 12 0f 34


                                                                                        REPORT No.: SZ15090025W04


 2.4        Conducted Spurious Emissions and Band Edge
 2.4.1 Requirement
 According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in
 which the spread spectrum or digitally modulated intentional radiator is operating, the radio
 frequency power that is produced by the intentional radiator shall be at least 20dB below that in the
 100kHz bandwidth within the band that contains the highest level of the desired power, based on
 either an RF conducted or a radiated measurement.

 2.4.2 Test Description

 A. Test Set:




 The EUT which is powered by the Battery, is coupled to the Spectrum Analyzer; the RF load
 attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct
 the reading.

 Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In
 order to make an accurate measurement, set the span greater than RBW.

 B. Equipments List:
 Please reference ANNEX A (1.4).
 2.4.3 Test Result
 The measurement frequency range is from 30MHz to the 10th harmonic of the fundamental
 frequency. The lowest, middle and highest channels are tested to verify the spurious emissions.

 A. Test Verdict:

                            Measured Max.                                                     Limit (dBm)
               Frequency                                        Refer to
  Channel                    Out of Band                                                Carrier         Calculated             Verdict
                 (MHz)                                           Plot
                            Emission (dBm)                                              Level          -20dBc Limit
       0         2402              -42.232                      Plot A.1                -1.169             -21.169              PASS
       19        2440              -43.875                      Plot B.1                -1.854             -21.854              PASS
       39        2480              -43.754                      Plot C.1                -1.833             -21.833              PASS

 B. Test Plots:
 Note: the power of the Module transmitting frequency should be ignored.


                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 13 0f 34


                                                                             REPORT No.: SZ15090025W04




                   (Plot A.1: Channel = 0, 30MHz to 25GHz)




                              (Band Edge@ Channel = 0)


                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 14 0f 34


                                                                             REPORT No.: SZ15090025W04




                 (Plot B.1:          Channel = 19, 30MHz to 25GHz)




                 (Plot C.1:          Channel = 39, 30MHz to 25GHz)


                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 15 0f 34


                                                                             REPORT No.: SZ15090025W04




                             (Band Edge@ Channel = 39)




                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 16 0f 34


                                                                                         REPORT No.: SZ15090025W04


 2.5    Power spectral density (PSD)
 2.5.1 Requirement
 For digitally modulated systems, the power spectral density conducted from the intentional radiator
 to the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of
 continuous transmission. This power spectral density shall be determined in accordance with the
 provisions of paragraph (b) of this section. The same method of determining the conducted output
 power shall be used to determine the power spectral density.

 2.5.2 Test Description

 A. Test Set:




 The EUT which is powered by the battery, is coupled to the Spectrum Analyzer; the RF load
 attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct
 the reading.

 B. Equipments List:
 Please reference ANNEX A (1.4).


 2.5.3 Test Result
 The lowest, middle and highest channels are tested.

 A. Test Verdict:

                                  Spectral power density (dBm/3kHz)
                    Frequency         Measured PSD                                                    Limit
       Channel                                                          Refer to Plot                                      Verdict
                      (MHz)            (dBm/3kHz)                                                  (dBm/3kHz)
          0           2402                  -13.688                           Plot A                     8                 PASS
          19          2440                  -14.180                           Plot B                     8                 PASS
          39          2480                  -14.178                           Plot C                     8                 PASS
       Measurement uncertainty: ±1.3dB

 B. Test Plots:




                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                   Page 17 0f 34


                                                                             REPORT No.: SZ15090025W04




                                    (Plot A: Channel = 0)




                                    (Plot B: Channel = 19)


                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 18 0f 34


                                                                             REPORT No.: SZ15090025W04




                                    (Plot C: Channel = 39)




                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 19 0f 34


                                                                                        REPORT No.: SZ15090025W04


 2.6    Restricted Frequency Bands
 2.6.1 Requirement
 According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in
 which the spread spectrum or digitally modulated intentional radiator is operating, the radio
 frequency power that is produced by the intentional radiator shall be at least 20dB below that in the
 100kHz bandwidth within the band that contains the highest level of the desired power, In addition,
 radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply
 with the radiated emission limits specified in 15.209(a).

 2.6.2 Test Description
 A. Test Setup




 The Module is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on
 of the site as factors are calculated to correct the reading.

 For the Test Antenna:

 Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the
 ground to determine the maximum value of the field strength.

 B. Equipments List:

 Please reference ANNEX A(1.4).




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 20 0f 34


                                                                                          REPORT No.: SZ15090025W04


 2.6.3 Test Result
 The lowest and highest channels are tested to verify the Restricted Frequency Bands.

 The measurement results are obtained as below:
 E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
 AT: Total correction Factor except Antenna
 UR: Receiver Reading
 Gpreamp: Preamplifier Gain
 AFactor: Antenna Factor at 3m

 Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal
 polarity, and only the worse test condition (vertical) was recorded in this test report.

 A. Test Verdict:

                                           Receiver                                      Max.
                           Detector
             Frequency                     Reading               AT            AFactor Emission   Limit
 Channel                                                                                                 Verdict
               (MHz)                          UR                (dB)         (dB@3m)      E     (dBµV/m)
                            PK/ AV
                                            (dBuV)                                     (dBµV/m)

     0        2362.99         PK              42.80           -33.63            32.56               41.73              74            Pass

     0        2359.40         AV              35.00           -33.63            32.56               33.93              54            Pass

    39        2485.71         PK              45.86           -33.18             32.5               45.18              74            Pass

    39        2485.87         AV              36.20           -33.18             32.5               35.52              54            Pass



 B. Test Plots:




                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,          Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                    Page 21 0f 34


                                                                             REPORT No.: SZ15090025W04




                             (Plot A1: Channel = 0 PEAK)




                               (Plot A2: Channel = 0 AVG)


                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 22 0f 34


                                                                             REPORT No.: SZ15090025W04




                            (Plot B1: Channel = 39 PEAK)




                              (Plot B2: Channel = 39 AVG)



                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P   Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                      Page 23 0f 34


                                                                                         REPORT No.: SZ15090025W04


 2.7        Radiated Emission
 2.7.1 Requirement
 According to FCC section 15.247(d), radiated emission outside the frequency band attenuation
 below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated
 emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also
 comply with the radiated emission limits specified in FCC section 15.209(a).

 According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions
 from an intentional radiator shall not exceed the field strength levels specified in the following table:

  Frequency (MHz)                       Field Strength (µV/m)                                Measurement Distance (m)
  0.009 - 0.490                         2400/F(kHz)                                          300
  0.490 - 1.705                         24000/F(kHz)                                         30
  1.705 - 30.0                          30                                                   30
  30 - 88                               100                                                  3
  88 - 216                              150                                                  3
  216 - 960                             200                                                  3
  Above 960                             500                                                  3

 Note:

       1.   For Above 1000MHz, the emission limit in this paragraph is based on measurement
            instrumentation employing an average detector, measurement using instrumentation with
            a peak detector function, corresponding to 20dB above the maximum permitted average
            limit.

       2.   For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and
            74dBuV/m@3m (PK)

 In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a),
 also should comply with the radiated emission limits specified in Section 15.209(a)(above table)




                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                  Page 24 0f 34


                                                                                      REPORT No.: SZ15090025W04


 2.7.2 Test Description

 A. Test Setup:
    1)   For radiated emissions from 9kHz to 30MHz




    2)   For radiated emissions from 30MHz to1GHz




                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                               Page 25 0f 34


                                                                                       REPORT No.: SZ15090025W04


     3)   For radiated emissions above 1GHz




 The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to
 the standards: ANSI C63.4 (2009). For radiated emissions below or equal to 1GHz,The EUT was
 set-up on insulator 80cm above the Ground Plane, For radiated emissions above 1GHz, The EUT
 was set-up on insulator 150cm above the Ground Plane. The set-up and test methods were
 according to ANSI C63.4.

 The Module is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on
 of the site as factors are calculated to correct the reading.

 For the Test Antenna:

 (a) In the frequency range of 9kHz to 30MHz, magnetic field is measured with Loop Test Antenna.
 The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of
 the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna
 rotates about its vertical axis for maximum response at each azimuth about the EUT.
 (b) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
 Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
 varied from 1m to 4m above the ground to determine the maximum value of the field strength. The
 emission levels at both horizontal and vertical polarizations should be tested.

 B. Equipments List:
 Please reference ANNEX A(1.4).



                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                Page 26 0f 34


                                                                                         REPORT No.: SZ15090025W04


 2.7.3 Test Result
 According to ANSI C63.4 selection 4.2.2, because of peak detection will yield amplitudes equal to
 or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement
 data from a spectrum analyzer peak detector will represent the worst-case results, if the peak
 measured value complies with the quasi-peak limit, it is unnecessary to perform an quasi-peak
 measurement.

 The measurement results are obtained as below:
     E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
     AT: Total correction Factor except Antenna
     UR: Receiver Reading
     Gpreamp: Preamplifier Gain
     AFactor: Antenna Factor at 3m

 During the test, the total correction Factor AT and AFactor were built in test software.

 Note: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
 test condition was recorded in this test report.

 The low frequency, which started from 9KHz to 30MHz, was pre-scanned and the result which was
 20dB lower than the limit line per 15.31(o) was not reported.




                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                  Page 27 0f 34


                                                                                          REPORT No.: SZ15090025W04


 A. Test Plots for the Whole Measurement Frequency Range:
 Plots for Channel = 0




             Fre.(MHz)      Pk       QP       AV      Limit-PK        Limit-QP        Limit-AV       Antenna         Verdict
               49.424      19.45    N.A      N.A          N.A           40.00            N.A         Horizontal      PASS
              223.029      38.62    N.A      N.A          N.A           46.00            N.A         Horizontal      PASS
              423.342      29.19    N.A      N.A          N.A           46.00            N.A         Horizontal      PASS
              2644.808     44.11    N.A      N.A         74.0            N.A            54.00        Horizontal      PASS
              7048.227     46.53    N.A      N.A         74.0            N.A            54.00        Horizontal      PASS
             15015.930     48.93    N.A      N.A         74.0            N.A            54.00        Horizontal      PASS

                                    (Antenna Horizontal, 30MHz to 25GHz)




              Fre. (MHz)     Pk       QP        AV      Limit-PK        Limit-QP        Limit-AV      Antenna       Verdict
               43.354       22.84     N.A      N.A         N.A            40.00               N.A     Vertical       PASS
               219.387      25.49     N.A      N.A         N.A            46.00               N.A     Vertical       PASS
              1565.986      39.90     N.A      N.A         74.0            N.A                54.0    Vertical       PASS
              3153.992      45.82     N.A      N.A         74.0            N.A                54.0    Vertical       PASS
              9003.492      48.99     N.A      N.A         74.0            N.A                54.0    Vertical       PASS
              15985.416     49.51     N.A      N.A         74.0            N.A                54.0    Vertical       PASS

                                     (Antenna Vertical, 30MHz to 25GHz)




                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,           Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                      Page 28 0f 34


                                                                                         REPORT No.: SZ15090025W04


 Plot for Channel = 19




             Fre.(MHz)     Pk      QP       AV       Limit-PK       Limit-QP         Limit-AV       Antenna         Verdict
               49.424     18.66    N.A      N.A         N.A            40.00            N.A         Horizontal       PASS
              225.457     38.01    N.A      N.A         N.A            46.00            N.A         Horizontal       PASS
              424.556     28.59    N.A      N.A         N.A            46.00            N.A         Horizontal       PASS
              4559.338    45.87    N.A      N.A         74.0            N.A           54.00         Horizontal       PASS
              8408.765    47.29    N.A      N.A         74.0            N.A           54.00         Horizontal       PASS
             17366.321    49.11    N.A      N.A         74.0            N.A           54.00         Horizontal       PASS

                                  (Antenna Horizontal, 30MHz to 25GHz)




              Fre.(MHz)      Pk        QP       AV      Limit-PK        Limit-QP        Limit-AV      Antenna        Verdict
               44.568      22.89      N.A      N.A          N.A           40.00              N.A       Vertical       PASS
               76.133      16.29      N.A      N.A          N.A           40.00              N.A       Vertical       PASS
              226.671      25.28      N.A      N.A          N.A           46.00              N.A       Vertical       PASS
              2277.951     43.21      N.A      N.A         74.0            N.A               54.0      Vertical       PASS
              8991.271     47.93      N.A      N.A         74.0            N.A               54.0      Vertical       PASS
             14294.926     48.75      N.A      N.A         74.0            N.A               54.0      Vertical       PASS

                                    (Antenna Vertical, 30MHz to 25GHz)


                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,            Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                      Page 29 0f 34


                                                                                        REPORT No.: SZ15090025W04




 Plot for Channel = 39




             Fre. (MHz)    Pk       QP        AV      Limit-PK        Limit-QP        Limit-AV     Antenna         Verdict
              44.568      18.59     N.A      N.A         N.A            40.00               N.A    Horizontal       PASS
              233.955     37.22     N.A      N.A         N.A            46.00               N.A    Horizontal       PASS
              429.412     27.58     N.A      N.A         N.A            46.00               N.A    Horizontal       PASS
             2589.116     43.97     N.A      N.A         74.0            N.A                54.0   Horizontal       PASS
             6954.537     46.69     N.A      N.A         74.0            N.A                54.0   Horizontal       PASS
             16099.473    49.41     N.A      N.A         74.0            N.A                54.0   Horizontal       PASS

                                  (Antenna Horizontal, 30MHz to 25GHz)




              Fre.(MHz)     Pk        QP       AV      Limit-PK        Limit-QP        Limit-AV    Antenna        Verdict
               44.568     22.94      N.A      N.A          N.A           40.00               N.A    Vertical       PASS
               84.631     17.64      N.A      N.A          N.A           40.00               N.A    Vertical       PASS
               175.682    24.02      N.A      N.A          N.A           43.50               N.A    Vertical       PASS
               525.319    27.47      N.A      N.A          N.A           46.00               N.A    Vertical       PASS
              2819.967    43.79      N.A      N.A         74.0            N.A               54.0    Vertical       PASS
             10832.479    47.26      N.A      N.A         74.0            N.A               54.0    Vertical       PASS

                                   (Antenna Vertical, 30MHz to 25GHz)


                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,          Tel: 86-755-36698555     Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.com    E-mail: service@morlab.cn

                                                                                                                                   Page 30 0f 34


                                                                                       REPORT No.: SZ15090025W04


 2.8    RF exposure evaluation
 2.8.1 Requirement
 According to § 1.1307(b)(1), systems operating under the provisions of this section shall be
 operated in a manner that ensure that the public is not exposed to radio frequency energy lever in
 excess of Commission’s guideline.


 2.8.2 Result
 Please refer to SAR report.




                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                Page 31 0f 34


                                                                                       REPORT No.: SZ15090025W04



 ANNEX A GENERAL INFORMATION
 1.1    Identification of the Responsible Testing Laboratory
  Company Name:                              Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                                Morlab Laboratory
  Address:                                   FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                             Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                             Province, P. R. China
  Responsible Test Lab Manager:              Mr. Su Feng
  Telephone:                                 +86 755 36698555
  Facsimile:                                 +86 755 36698525


 1.2    Identification of the Responsible Testing Location
  Name:                                      Shenzhen Morlab Communications Technology Co., Ltd.
                                             Morlab Laboratory
  Address:                                   FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                             Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                             Province, P. R. China


 1.3    Facilities and Accreditations

 Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory is a testing
 organization accredited by China National Accreditation Service for Conformity Assessment
 (CNAS) according to ISO/IEC 17025. The accreditation certificate number is L3572.

 All measurement facilities used to collect the measurement data are located at FL.1, Building A,
 FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is
 constructed in conformance with the requirements of ANSI C63.10 2013, ANSI C63.4 2009 and
 CISPR Publication 22; the FCC registration number is 695796.




                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                Page 32 0f 34


                                                                                           REPORT No.: SZ15090025W04


      1.4      Test Equipments Utilized
      1.4.1    Conducted Test Equipments
Conducted Test Equipment
No.    Equipment Name        Serial No.                 Type                 Manufacturer                 Cal. Date                 Cal. Due
 1     Spectrum Analyzer    MY45101810                E4407B                       Agilent               2015.02.26               2016.02.25
 2        Power Splitter      NW521                    1506A                    Weinschel                2015.02.26               2016.02.25
 3        Attenuator 1          (n.a.)                  10dB                       Resnet                2015.02.26               2016.02.25
 4        Attenuator 2          (n.a.)                   3dB                       Resnet                2015.02.26               2016.02.25
 5       USB Wideband       MY52280010              U2021XA                        Agilent               2015.02.26               2016.02.25
         Power Sensor
 6            EXA Signal    MY51440152                N9010A                       Agilent               2015.02.26               2016.02.25
               Analzyer
 7            RF cable         CB01                     RF01                       Morlab                      N/A                       N/A
 8        Coaxial cable        CB02                     RF02                       Morlab                      N/A                       N/A
 9       SMA connector         CN01                     RF03              HUBER-SUHNER                         N/A                       N/A


      1.4.2    Conducted Emission Test Equipments
Conducted Emission Test Equipments
No.    Equipment Name        Serial No.                    Type                 Manufacturer              Cal. Date                 Cal. Due
 1             Receiver     US44210471                   E7405A                       Agilent            2015.02.26               2016.02.25
 2              LISN          812744                  NSLK 8127                 Schwarzbeck              2015.02.26               2016.02.25
 3      Service Supplier      100448                    CMU200                          R&S              2015.02.26               2016.02.25
 4        Pulse Limiter         9391                      VTSD                  Schwarzbeck              2015.02.26               2016.02.25
             (20dB)                                      9561-D
 5     Coaxial cable(BNC)      CB01                      EMC01                        Morlab                   N/A                       N/A




                               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
 M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                    Page 33 0f 34


                                                                                                   REPORT No.: SZ15090025W04


         1.4.3     Radiated Test Equipments
Radiated Test Equipments
No.       Equipment Name              Serial No.                   Type                 Manufacturer              Cal. Date             Cal.Due Date
 1                Receiver           US44210471                  E7405A                       Agilent            2015.02.26                2016.02.25
            Test Antenna -            9163-274                9m*6m*6m                      Albatross            2015.02.26                2016.02.25
 2
                Bi-Log
 3        Test Antenna - Horn        9120D-963                VULB 9163                 Schwarzbeck              2015.02.26                2016.02.25
 4        Test Antenna - Horn          71688                BBHA 9120D                  Schwarzbeck              2015.02.26                2016.02.25
 5       Test Antenna - Loop          1519-022                 HL050S7                          R&S              2015.02.26                2016.02.25
 6               Reject Filter          (n.a.)                BRM50702                  Micro-Tronics            2015.02.26                2016.02.25
             Coaxial cable              CB02                     EMC02                        Morlab                   N/A                       N/A
 7
               (N male)
             Coaxial cable              CB03                     EMC03                        Morlab                   N/A                       N/A
 8
               (N male)


         1.4.4     Climate Chamber
Climate Chamber
No.          Equipment Name            Serial No.               Type             Manufacturer                  Cal.Date                Cal.Due Date
 1           Climate Chamber            2004012              HL4003T                     Yinhe               2015.02.26                  2016.02.25


         1.4.5     Vibration Table
 Vibration Table
 No.         Equipment Name            Serial No.                Type               Manufacturer                Cal.Date               Cal.Due Date
                                                             ACT2000-
  1              Vibration Table            N/A                                        CMI-COM                2015.02.26                 2016.02.25
                                                              S015L


         1.4.6     Anechoic Chamber
 Anechoic Chamber
 No.         Equipment Name            Serial No.                 Type               Manufacturer                Cal.Date             Cal.Due Date
     1      Anechoic Chamber                N/A              9m*6m*6m                     Albatross            2015.02.26               2016.02.25


                                                 ***** END OF REPORT *****




                                       FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
  M ORLAB GROU P                       Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                            Page 34 0f 34



Document Created: 2017-11-14 15:57:29
Document Modified: 2017-11-14 15:57:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC