RF Exporure

FCC ID: 2ACVC-AOWL2

RF Exposure Info

Download: PDF
FCCID_4389039

                                    FCC ID: 2ACVC-AOWL2
Portable device
According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio
frequency energy level in excess of the Commission’s guidelines.
According to KDB447498 D01 General RF Exposure Guidance V06
The 1-g SAR and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)]·[√f(GHZ)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where:
  •     f(GHZ) is the RF channel transmit frequency in GHz
  •     Power and distance are rounded to the nearest mW and mm before calculation
  •     The result is rounded to one decimal place for comparison
When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
determine SAR test exclusion.

Antenna Type: PCB Antenna                          Antenna Gain: 2 dBi
                  Conduct                    Max        Max
          Channel    ed   Conducte Tune-up tune-up    tune-up            Result     1g SAR
                                                                Distance                        SAR test
Modulation Freq.   power d power power power           power             calculatio Exclusion
                                                                 (mm)                           exclusion
           (GHz)   (dBm)   (mW)     (dBm) (dBm)        (mW)              n          threshold
             2.402   -3.76   0.421   5±1     6.0      3.981       <5      1.23400      3.00       YES
  GFSK       2.441   -3.53   0.444   5±1     6.0      3.981       <5      1.24398      3.00       YES
             2.480   -3.97   0.401   5±1     6.0      3.981       <5      1.25388      3.00       YES
             2.402   -2.69   0.538   2.5±1   3.5      2.239       <5      0.69393      3.00       YES
  π/4-
 DQPSK
             2.441   -2.47   0.566   2.5±1   3.5      2.239       <5      0.69954      3.00       YES
             2.480   -2.88   0.515   2.5±1   3.5      2.239       <5      0.70511      3.00       YES




Conclusion:
For the max result: 1.25388≤ 3.0 for 1-g SAR, No SAR is required.




Signature:                                                             Date: 2019-07-10


NAME AND TITLE (Please print or type): Jason Chen /Manager
COMPANY (Please print or type): Shenzhen NTEK Testing Technology Co., Ltd./ 1/F, Building E,
Fenda Science Park, Sanwei Community, Xixiang Street Bao’an District, Shenzhen 518126 P.R.
China



Document Created: 2019-08-22 13:13:04
Document Modified: 2019-08-22 13:13:04

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC