RF Exposure information

FCC ID: 2ACV4-M60G-002

RF Exposure Info

Download: PDF
FCCID_4482159

Human Exposure to Radiofrequency fields –
calculations as defined by OET65




Document: Human Exposure to RF (OET65)
Version: v1.0


Table of Contents
1.   Overview ................................................................................................................................. 3

2.   Device characteristics – Metnet 60GHz CPE........................................................................ 3
     2.1       Calculation of compliance boundary for general public exposure.................................. 3

3.   Installation guidance to ensure general public are outside compliance boundaries........ 4




                                                                                                                                          2


1.     Overview

This document shows the calculation of the compliance boundary for the Metnet 60G CPE product
to meet the basic restrictions as defined in OET65 Edition 97-01.


The limit for occupational exposure according to OET65 is 5mW/cm2 (50W/m2).
The limit for general population exposure according to OET65 is 1mW/cm2 (10W/m2).



2.     Device characteristics – Metnet 60GHz CPE

The Metnet node emits RF energy through Beamforming Phase array antenna, 16x2 element
arrangement with 20dBi gain per antenna (waveguide) port.
The maximum RF power output from a node is 40 dBm (with QPSK modulation).

2.1 Calculation of compliance boundary for general public
    exposure

The far field (spherical) calculation method defined in equation 3 of OET65 has been used to
define the compliance boundary, using the maximum gain noted above.


As mentioned in Section 2 of the OET 65, this gives a conservative result (it overestimates the field
strength) for near field. Therefore the exposure at the distance calculated below will be well within
safe limits.


S= Power Density – basic restriction is 10W/m2
P= Output Power
G= Gain (relative to isotropic)
r= compliance boundary radius
S= (PG)/ (4πr2)
PG=40dBm =10 Watts
Therefore:


r2 =(PG)/(S4π)




                                                                                                3


r2 = 10 /(10 x 4π)


r = 28.2 cm


(For occupational exposure, according to OET65, r=12.6 cm)



3.      Installation guidance to ensure general public are
        outside compliance boundaries

The Metnet 60G CPE is designed to be mounted on street furniture (e.g. lampposts) adjacent to
small cellular base stations.


The equipment is necessarily mounted out of reach of the general public for the following reasons:


     1. To avoid interference with the equipment by the general public
     2. To avoid blocking of the radio signal by passing traffic e.g. double-decker buses – requires
        installation height greater than 5 metres


Therefore the equipment is only accessible to authorised personnel.